Search NASA⌕ Search

SEARCH · Search NASA

Results for “THROUGHPUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

New high-throughput endstation to accelerate the experimental optimization pipeline for synchrotron X-ray footprinting

Synchrotron X-ray footprinting (XF) is a growing structural biology technique that leverages radiation-induced chemical modifications via X-ray radiolysis of water to produce hydroxyl radicals that probe changes in macromolecular structure and dynamics in solution states of interest. The X-ray Footprinting of Biological Materials (XFP) beamline at the National Synchrotron Light Source II provides the structural biology community with access to instrumentation and expert support in the XF method, and is also a platform for development of new technological capabilities in this field. Hee, the design and implementation of a new high-throughput endstation device based around use of a 96-well PCR plate form factor and supporting diagnostic instrumentation for synchrotron XF is described. This development enables a pipeline for rapid comprehensive screening of the influence of sample chemistry on hydroxyl radical dose using a convenient fluorescent assay, illustrated here with a study of 26 organic compounds. The new high-throughput endstation device and sample evaluation pipeline now available at the XFP beamline provide the worldwide structural biology community with a robust resource for carrying out well optimized synchrotron XF studies of challenging biological systems with complex sample compositions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Throughput Estimation of Data Transport Networks From Digital Twin Measurements

Digital twins of networked infrastructures, known as Virtual Infrastructure Twins (VITs), are increasingly used for software development, pre-deployment testing, and design space exploration. While VITs avoid the costs and potential disruptions associated with experiments on operational networks, their throughput measurements are typically not sufficiently accurate for performance profiling of wide-area networks that they emulate. Here, machine learning (ML) methods are developed to transform these inaccurate VIT network throughput measurements to closely match in peak and overall profile of those from a physical testbed or production network. First, a micro kernel network reflecting a physical network is utilized to collect one-time measurements on a host to support this ML transformation. Then, a generic multi-modal ML method is developed to learn a map that transforms measurements from subsequent VITs on the same host to match past, current and follow-on testbed and cloud networks. ML generalization equations are derived to establish its correctness and probabilistically guarantee its generalization accuracy. Experimental results are presented for a variety of VIT hosts with target testbed and cloud networks; they include a case study of a four-site science ecosystem wherein inaccurate convex VIT measurement profiles are transformed into accurate concave profiles of target networks.

97 MATHEMATICS AND COMPUTING↗

An automated workflow to screen alkene reductases using high-throughput thin layer chromatography

Background: Synthetic biology efforts often require high-throughput screening tools for enzyme engineering campaigns. While innovations in chromatographic and mass spectrometry-based techniques provide relevant structural information associated with enzyme activity, these approaches can require cost-intensive instrumentation and technical expertise not broadly available. Moreover, complex workflows and analysis time can significantly impact throughput. To this end, we develop an automated, 96-well screening platform based on thin layer chromatography (TLC) and use it to monitor in vitro activity of a geranylgeranyl reductase isolated from Sulfolobus acidocaldarius (SaGGR). Results: Unreduced SaGGR products are oxidized to their corresponding epoxide and applied to thin layer silica plates by acoustic printing. These derivatives are chromatographically separated based on the extent of epoxidation and are covalently ligated to a chromophore, allowing detection of enzyme variants with unique product distributions or enhanced reductase activity. Herein, we employ this workflow to examine farnesol reduction using a codon-saturation mutagenesis library at the Leu377 site of SaGGR. We show this TLC-based screen can distinguish between fourfold differences in enzyme activity for select mutants and validated those results by GC–MS. Conclusions: With appropriate quantitation methods, this workflow can be used to screen polyprenyl reductase activity and can be readily adapted to analyze broader catalyst libraries whose products are amenable to TLC analysis.

09 BIOMASS FUELS↗

High-Throughput Discovery of Robust Metal-Organic Frameworks for CO 2 Capture (Final Report)

The goal of the project is to develop and utilize high-throughput instrumentation for the discovery of robust, cost-effective metal-organic frameworks for the efficient capture of CO 2 from power plant flue gas. To this end, we have used highly-parallel and automated synthesize methods to accelerate the discovery of new MOF structures and their optimized synthesis and activation routes. To be able to rapidly screen these new materials for their potential CO 2 capture performance, we have developed high-throughput structural characterization instruments and gas adsorption instruments. To guide the materials choice and design, we have also developed computational tools to analyze the life cycle and sorbent performance of existing and hypothetical materials.

36 MATERIALS SCIENCE↗

Micellar Surfactant Association in the Presence of a Glucoside-based Amphiphile Detected via High-Throughput Small Angle X-ray Scattering

The interactions of mixtures of anionic and amphoteric surfactants with sugar amphiphiles were studied via high throughput small angle x-ray scattering (SAXS). The sugar amphiphile was composed of Caprate, Caprylate, and Oleate mixed ester of methyl glucoside, MeGCCO. Optimal surfactant interactions are sought which have desirable physical properties, which must be identified in a cost effective manner that can access the large phase space of possible molecular combinations. X-ray scattering patterns obtained via high throughput SAXS can probe a combinatorial sample space and reveal the incorporation of MeGCCO into the micelles and the molecular associations between surfactant molecules. Such data make it possible to efficiently assess the effects of the new amphiphiles in the formulation. A specific finding of this study is that formulations containing comparatively monodisperse and homogeneous surfactant mixtures can be reliably tuned by addition of NaCl, which swells the surfactant micelles with a monotonic dependence on salt concentration. In contrast, the presence of multiple different surfactants destroys clear correlations with NaCl concentration, even in otherwise similar series of formulations.

36 MATERIALS SCIENCE↗

Accelerated Materials Design for Molten Salt Technologies Using Innovative High-Throughput Methods

The focus of the project is on building an innovative accelerated materials design platform for molten salt technologies using novel high-throughput methods coupled to data analytics. The main objectives is to predict a FeCrMnNi alloy compositional space with better corrosion resistance than stainless steel 316 and identify new molten salt corrosion mechanisms. The project demonstrates the feasibility to use high-throughput methods coupled to data analytics to accelerate alloy design for extreme environments applications. Using a trained and tested machine learning (ML) model, 2000 FeCrMnNi alloy corrosion rate in molten chloride salts were predicted and a compositional field with corrosion rate lower than 316 stainless steel was identified. The ML model interpretability unveiled multiple features of importance in the model prediction. Some features were expected to be of relative significance, such as work function, surface energy and alloy electronegativity, and the ML model interpretability analysis confirmed those. On the other hand, the most important feature is the diffusion coefficient of Ni in the bulk alloy which indicates that a surface diffusion mechanism plays an important role in the overall corrosion mechanism in molten salts.

36 MATERIALS SCIENCE↗

Photonic Curing of Nickel Oxide Transport Layer and Perovskite Active Layer for Flexible Perovskite Solar Cells: A Path Towards High-Throughput Manufacturing

High-throughput roll-to-roll (R2R) manufacturing of perovskite solar cells (PSCs) is currently limited by thermal processes that take tens of minutes each, translating to impractically long annealing tools at high web speeds. In addition, PSCs are usually made with metal oxide transport layer materials that require high temperatures for thermal annealing. Here, we demonstrate the fabrication of PSCs using photonic curing, instead of thermal annealing, to convert NiO x directly from sol-gel precursors for hole transport layers and to crystallize methylammonium lead iodide (MAPbI 3 ) active layers on flexible Willow ® Glass substrates. Photonic curing uses short, intense pulses of light to process materials at a high speed, hence it is compatible with R2R manufacturing. We achieved power conversion efficiencies (PCEs) of 11.7% in forward-scan and 10.9% in reverse-scan for PSCs made with photonic cured NiO x and MAPbI 3 films. Furthermore, both NiO x and MAPbI 3 films could be processed with a single photonic curing pulse, with a web speed of 5.7 m/min, and still produce PCEs comparable to thermally annealed control samples. Based on the single-pulse photonic curing condition for each film, we project a web speed of 26 m/min, laying a pathway to high-throughput production of perovskite solar modules.

14 SOLAR ENERGY↗

HtPIP: High-throughput phage isolation platform increases diversity and reduces isolation time using multiple bacteria

Bacteriophages are ubiquitous in nature, but relatively few have been isolated and characterized compared to the number of bacterial strains. Phage biotechnology applications benefit from a diverse library of isolated phages to kill or transfer genetic material to a bacterium of interest. However, scaling up phage discovery for diverse bacterial hosts can be time-consuming and costly. Here, we developed an approach to capture novel phages for multiple bacterial strains in parallel from an environmental sample using commercially available 0.2-μM filter plates. Using this High-throughput Phage Isolation Platform (HtPIP), 12 novel phages were isolated spanning 9 diverse bacterial host genera. Eleven of the isolated phages define new phage species, with nine also defining new genera. The HtPIP was used to discover both DNA and RNA phages, including a Tectiviridae infecting Pseudomonas putida mt-2 and a Leviviricetes infecting a Microbacterium isolate, which represents the first cultured RNA phage infecting a host outside of Proteobacteria. Using a metagenomic approach, we demonstrate that the HtPIP captures a higher proportion of novel phages compared to traditional low-throughput methods.

High-throughput↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode, also known as multiple reaction monitoring (MRM), is capable of quantitatively measuring hundreds of candidate protein biomarkers from a relevant clinical sample in a single analysis. The specificity, reproducibility and sensitivity could be as good as ELISA. Furthermore, SRM MS can also quantify protein isoforms and post-translational modifications, for which traditional antibody-based immunoassays often don’t exist.

Environmental Molecular Sciences Laboratory↗

Indirect Liftoff Mechanism for High‐Throughput, Single‐Source Laser Scribing for Perovskite Solar Modules

A high‐throughput, single‐source laser scribing method exploiting a transparent conducting oxide (TCO) indirect liftoff mechanism is developed to produce serially interconnected perovskite solar modules. The TCO‐based indirect liftoff mechanism relies solely on laser absorption in the front transparent electrode material reducing thermal damage to the overlying layers and allowing for fast scribing speeds with low‐cost μs‐pulse duration fiber laser systems. Minimal resistive power losses are observed with the method compared to conventional ablative laser scribes, maintaining the power conversion efficiencies of small‐area devices (≈0.2 cm 2 ) across significantly larger deposition areas (≈1 cm 2 ). Finally, demonstrating > 3 m s −1 processing speeds, TCO‐based liftoff provides the highest throughput laser scribing method for thin‐film photovoltaic devices produced on glass/TCO substrates, capable of processing large‐area perovskite solar modules at a manufacturing scale.

14 SOLAR ENERGY↗

Impact of media and antifoam selection on monoclonal antibody production and quality using a high throughput micro-bioreactor system

Monoclonal antibody production in commercial scale cell culture bioprocessing requires a thorough understanding of the engineering process and components used throughout manufacturing. It is important to identify high impact components early on during the lifecycle of a biotechnology-derived product. While cell culture media selection is of obvious importance to the health and productivity of mammalian bioreactor operations, other components such as antifoam selection can also play an important role in bioreactor cell culture. Silicone polymer-based antifoams were known to have negative impacts on cell health, production, and downstream filtration and purification operations. High throughput screening in micro-scale bioreactors provides an efficient strategy to identify initial operating parameters. Here, we utilized a micro-scale parallel bioreactor system to study an IgG1 producing CHO cell line, to screen Dynamis, ProCHO5, PowerCHO2, EX-Cell Advanced, and OptiCHO media, and 204, C, EX-Cell, SE-15, and Y-30 antifoams and their impacts on IgG1 production, cell growth, aggregation, and process control. This study found ProCHO5, EX-Cell Advanced, and PowerCHO2 media supported strong cellular growth profiles, with an IVCD of 25-35 3 106 cells-d/ mL, while maintaining specific antibody production (Qp> 2 pg/cell-d) for our model cell line and a monomer percentage above 94%. Antifoams C, EX-Cell, and SE-15 were capable of providing adequate control of foaming while antifoam 204 and Y-30 noticeably stunted cellular growth. This work highlights the utility of high throughput micro bioreactors and the importance of identifying both positive and negative impacts of media and antifoam selection on a model IgG1 producing CHO cell line.

59 BASIC BIOLOGICAL SCIENCES↗

High-Throughput Mapping of the Electrochemical Properties of (Ni-Fe-Co-Ce)O x Oxygen-Evolution Catalysts

Discovering improved electrocatalysts is critical for many technologically important processes and for the development of new clean-energy technologies. In this paper, high-throughput methods for measuring fundamental electrochemical properties are demonstrated through the investigation of oxygen-evolution catalysis by using 665 oxide compositions containing nickel, iron, cobalt, and cerium. The behavior of each composition is characterized in 1.0 M NaOH(aq) by using a scanning drop three-electrode cell to perform chronopotentiometry (CP) and cyclic voltammetry experiments. CP measurements at different current densities identify different composition–performance trends, owing to underlying variations in fundamental electrochemical behavior. We report systematic, coincident, composition-dependent trends in the Tafel slopes and the reversible redox potentials of the catalysts. Finally, applying high-throughput electrochemical methods provides insight into composition–property–performance relationships and motivates new directions for the study of catalyst mechanisms by using informatics and theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerating virtual high-throughput ligand docking: current technology and case study on a petascale supercomputer

In this paper, we give the current state of high-throughput virtual screening. We describe a case study of using a task-parallel Message Passing Interface version of AutoDock4 to run a virtual high-throughput screen of one million compounds on the Jaguar Cray XK6 Supercomputer at Oak Ridge National Laboratory. We include a description of scripts developed to increase the efficiency of the predocking file preparation and postdocking analysis. A detailed tutorial, scripts, and source code for this Message Passing Interface version of AutoDock4 are available online at http://www.bio.utk.edu/baudrylab/autodockmpi.htm.

97 MATHEMATICS AND COMPUTING↗

High‐throughput profiling and analysis of plant responses over time to abiotic stress

Abstract Sorghum ( Sorghum bicolor (L.) Moench) is a rapidly growing, high‐biomass crop prized for abiotic stress tolerance. However, measuring genotype‐by‐environment (G x E) interactions remains a progress bottleneck. We subjected a panel of 30 genetically diverse sorghum genotypes to a spectrum of nitrogen deprivation and measured responses using high‐throughput phenotyping technology followed by ionomic profiling. Responses were quantified using shape (16 measurable outputs), color (hue and intensity), and ionome (18 elements). We measured the speed at which specific genotypes respond to environmental conditions, in terms of both biomass and color changes, and identified individual genotypes that perform most favorably. With this analysis, we present a novel approach to quantifying color‐based stress indicators over time. Additionally, ionomic profiling was conducted as an independent, low‐cost, and high‐throughput option for characterizing G x E, identifying the elements most affected by either genotype or treatment and suggesting signaling that occurs in response to the environment. This entire dataset and associated scripts are made available through an open‐access, user‐friendly, web‐based interface. In summary, this work provides analysis tools for visualizing and quantifying plant abiotic stress responses over time. These methods can be deployed as a time‐efficient method of dissecting the genetic mechanisms used by sorghum to respond to the environment to accelerate crop improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Quantum-Dot-Based Electrochemical Immunoassay for High-Throughput Screening of the Prostate-Specific Antigen

In this paper, we demonstrate an electrochemical high-throughput sensing platform for simple, sensitive detection of PSA based on QD labels. This sensing platform uses a microplate for immunoreactions and disposable screen-printed electrodes (SPE) for electrochemical stripping analysis of metal ions released from QD labels. With the 96-well microplate, capturing antibodies are conveniently immobilized to the well surface, and the process of immunoreaction is easily controlled. The formed sandwich complexes on the well surface are also easily isolated from reaction solutions. In particular, a microplate-based electrochemical assay can make it feasible to conduct a parallel analysis of several samples or multiple protein markers. This assay offers a number of advantages including (1) simplicity, cost-effectiveness, (2) high sensitivity, (3) capability to sense multiple samples or targets in parallel, and (4) a potentially portable device with an SPE array implanted in the microplate. This PSA assay is sensitive because it uses two amplification processes: (1) QDs as a label for enhancing electrical signal since secondary antibodies are linked to QDs that contain a large number of metal atoms and (2) there is inherent signal amplification for electrochemical stripping analysis—preconcentration of metal ion onto the electrode surface for amplifying electrical signals. Therefore, the high sensitivity of this method, stemming from dual signal amplification via QD labels and pre-concentration, allows low concentration levels to be detected while using small sample volumes. Thus, this QD-based electrochemical detection approach offers a simple, rapid, cost-effective, and high throughput assay of PSA.

59 BASIC BIOLOGICAL SCIENCES↗

Automated High‐Throughput Fatigue Testing of Freestanding Thin Films

Abstract Mechanical testing at small length scales has traditionally been resource‐intensive due to difficulties with meticulous sample preparation, exacting load alignments, and precision measurements. Microscale fatigue testing can be particularly challenging due to the time‐intensive, tedious repetition of single fatigue experiments. To mitigate these challenges, this work presents a new methodology for the high‐throughput fatigue testing of thin films at the microscale. This methodology features a microelectromechanical systems‐based Si carrier that can support the simultaneous and independent fatigue testing of an array of samples. To demonstrate this new technique, the microscale fatigue behavior of nanocrystalline Al is efficiently characterized via this Si carrier and automated fatigue testing with in situ scanning electron microscopy. This methodology reduces the total testing time by an order of magnitude, and the high‐throughput fatigue results highlight the stochastic nature of the microscale fatigue response. This manuscript also discusses how this initial capability can be adapted to accommodate more samples, different materials, new geometries, and other loading modes.

Barrios, Alejandro↗

Analytical Validation of a Portable Mass Spectrometer Featuring Interchangeable, Ambient Ionization Sources for High Throughput Forensic Evidence Screening

Forensic evidentiary backlogs are indicative of the growing need for cost-effective, high-throughput instrumental methods. One such emerging technology that shows high promise in meeting this demand while also allowing on-site forensic investigation is portable mass spectrometric (MS) instrumentation, particularly that which enables the coupling to ambient ionization techniques. While the benefits of rapid, on-site screening of contraband can be anticipated, the inherent legal implications of field-collected data necessitates that the analytical performance of technology employed be commensurate with accepted techniques. To this end, comprehensive analytical validation studies are required before broad incorporation by forensic practitioners can be considered, and are the focus of this work. Pertinent performance characteristics such as throughput, selectivity, accuracy/precision, method robustness, and ruggedness have been investigated. Reliability in the form of false positive/negative response rates is also assessed, examining the effect of variables such as user training and experience level. To provide flexibility toward broad chemical evidence analysis, a suite of rapidly-interchangeable ion sources has been developed and characterized through the analysis of common illicit chemicals and emerging threats like substituted phenethylamines. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗