Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

POWTEX visits POWGEN

The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

Measuring time of flight of fusion products in an inertial electrostatic confinement fusion device for spatial profiling of fusion reactions

A new diagnostic has been developed that uses the time of flight (TOF) of the products from a nuclear fusion reaction to determine the location where the fusion reaction occurred. The TOF diagnostic uses charged particle detectors on opposing sides of the inertial electrostatic confinement (IEC) device that are coupled to high resolution timing electronics to measure the spatial profile of fusion reactions occurring between the two charged particle detectors. This diagnostic was constructed and tested by the University of Wisconsin-Madison Inertial Electrostatic Confinement Fusion Group in the IEC device, HOMER, which accelerates deuterium ions to fusion relevant energies in a high voltage ({approx}100 kV), spherically symmetric, electrostatic potential well [J. F. Santarius, G. L. Kulcinski, R. P. Ashley, D. R. Boris, B. B. Cipiti, S. K. Murali, G. R. Piefer, R. F. Radel, T. E. Radel, and A. L. Wehmeyer, Fusion Sci. Technol. 47, 1238 (2005)]. The TOF diagnostic detects the products of D(d,p)T reactions and determines where along a chord through the device the fusion event occurred. The diagnostic is also capable of using charged particle spectroscopy to determine the Doppler shift imparted to the fusion products by the center of mass energy of the fusion reactants. The TOF diagnostic is thus able to collect spatial profiles of the fusion reaction density along a chord through the device, coupled with the center of mass energy of the reactions occurring at each location. This provides levels of diagnostic detail never before achieved on an IEC device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SIMS Studies of Allende Projectiles Fired into Stardust-type Aluminum Foils at 6 km/s

We have explored the feasibility of C-, N-, and O-isotopic measurements by NanoSIMS and of elemental abundance determinations by TOF-SIMS on residues of Allende projectiles that impacted Stardust-type aluminum foils in the laboratory at 6 km/s. These investigations are part of a consortium study aimed at providing the foundation for the characterization of matter associated with micro-craters that were produced during the encounter of the Stardust space probe with comet 81P/Wild 2. Eleven experimental impact craters were studied by NanoSIMS and eighteen by TOF-SIMS. Crater sizes were between 3 and 190 microns. The NanoSIMS measurements have shown that the crater morphology has only a minor effect on spatial resolution and on instrumental mass fractionation. The achievable spatial resolution is always better than 200 nm, and C- and O-isotopic ratios can be measured with a precision of several percent at a scale of several 100 nm, the typical size of presolar grains. This clearly demonstrates that presolar matter, provided it survives the impact into the aluminum foil partly intact, is recognizable even if embedded in material of Solar System origin. TOF-SIMS studies are restricted to materials from the crater rim. The element ratios of the major rockforming elements in the Allende projectiles are well characterized by the TOF-SIMS measurements, indicating that fractionation of those elements during impact can be expected to be negligible. This permits information on the type of impactor material to be obtained. For any more detailed assignments to specific chondrite groups, however, information on the abundances of the light elements, especially C, is crucial.

Hoppe, Peter↗

High time-resolution photodetectors for PET applications

This paper describes recent developments aiming at the improvement of the time resolution of photodetectors used in positron emission tomography (PET). Promising photodetector candidates for future PET-time-of-flight (TOF) applications are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The N = 126 factory: A new facility to produce very heavy neutron-rich isotopes

A new facility, the N = 126 factory, is currently under construction at Argonne National Laboratory. It will use multi-nucleon transfer reactions to create neutron-rich isotopes of very heavy elements for studies of interest to the formation of the A similar to 195 abundance peak in the r-process. This region of the nuclear chart is difficult to access by standard fragmentation or spallation reactions and as a result has remained mostly unexplored. The nuclei of interest, very neutron-rich isotopes around Z = 70-95, will be produced by multi-nucleon exchange of a high intensity 10 MeV/u heavy-ion beam on the most neutron-rich stable isotopes of heavy elements such as 198 Pt and 238 U. This reaction mechanism can transfer a large number of neutrons and create very neutron-rich isotopes with larger than mb cross-section. The reaction mechanism is a nuclear surface process and the reaction products come out close to the grazing angle, which makes them very difficult to collect. The N = 126 factory circumvents this difficulty by using a unique large high-intensity RF gas catcher, similar to the one currently in operation at CARIBU, to collect the target-like reaction products and transform them into a low-energy beam that will then be mass separated with a medium resolution electromagnetic separator (Delta M/M similar or equal to 1/1500), followed by an RFQ buncher and an MR-TOF (Delta M/M similar or equal to 1/100,000) system. The extracted radioactive beams will be essentially pure and available at low-energy for mass measurements with the CPT mass spectrometer or decay study with the X-array.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Total Ambient Ion Count using Atmosphere Pressure Interface Time of Flight (APITOF) Mass Spectrometer

These files contain unit mass resolution data for selected masses measured by an atmospheric pressure interface time-of-flight mass spectometer (APi-ToF) during the 2016 Holistic Interactions of Shallow Clouds Aerosols and Land Ecosystems (HI-SCALE) campaign at the Atmospheric Radiation Measurement Southern Great Plains site. Data for selected ambient ions are presented. Measurements were collected between 2016 August 29 and 2016 September 23. The instrument was switched between positive and negative mode approximately every 24 hours. Positive and negative data are contained in separate files. Files are in ICARTT format.

54 ENVIRONMENTAL SCIENCES↗

CoURAGE Stationary ELF PTR-MS Measurements at the Mt. Airy Site

Gas phase measurements of volatile organic compounds (VOC) taken at the DOE ARM S2 site for the CoURAGE campaign using a Vocus ELF PTR-ToF (Tofwerk) mass spectrometer. Measurements of several VOC's (e.g., acetaldehyde, acetone, benzene, etc.) were obtained at 1-minute resolution from 4/08 to 5/19.

acetaldehyde_concentration↗

Rare Higgs Processes at CMS and Precision Timing Detector Studies for HL-LHC CMS Upgrade

This thesis describes the search for two rare Higgs processes. The first analysis describes the CMS Run 2 search for $H$ $\rightarrow$ $\mu$$\mu$ decays, with 137.3 fb$^{-1}$ of data at $\sqrt{s}$ = 13 TeV. The analysis targeted four different Higgs production modes: the gluon fusion (ggH), the vector boson fusion (VBF), the Higgs-strahlung process (VH), and the production in association with a pair of top quarks (ttH). Each category used a dedicated machine learning based classifier to separate the signal from the background processes. A combined fit from all these categories saw a slight excess in the data corresponding to 3.0 standard deviations at $M$$_{H}$ = 125.38 GeV, and gave the first evidence for the Higgs boson decay to second-generation fermions. The best-fit signal strength and the corresponding 68% CL interval was found to be +0.17?????? = 1.19 $_{-0.39}^{+0.41}$ (stat)$_{-0.16}^{+0.17}$(syst) at $M$$_{H}$ = 125.38 GeV. The second analysis describes the CMS Run 2 search for 𝐻𝐻 → 𝑏𝑏𝑏𝑏 with highly boosted Higgs bosons. This analysis used a dedicated jet identification algorithm based on graph neural networks (ParticleNet) to identify boosted H→ bb jets. This search targeted the gluon fusion and the vector boson fusion HH production modes, and put constraints on the allowed values of the various Higgs couplings as: 𝜅𝜆 ∈ [−9.9, 16.9] when 𝜅𝑉 = 1, 𝜅2𝑉 = 1; 𝜅𝑉 ∈ [−1.17, −0.79] ∪ [0.81, 1.18] when 𝜅𝜆 = 1, 𝜅2𝑉 = 1; 𝜅2𝑉 ∈ [0.62, 1.41] when 𝜅𝜆 = 1, 𝜅𝑉 = 1. A scenario with 𝜅2𝑉 = 0 was excluded with a significance of 6.3 standard deviations for the first time, when other H couplings are fixed to their SM values. The combined observed (expected) 95% upper limit on the HH production cross section was found to be 9.9 (5.1) × SM. Finally, this thesis also discusses the planned MIP Timing Detector (MTD) upgrade for CMS at the HL-LHC. The MTD will be a time-of-flight (TOF) detector, designed to provide a precision timing information for charged particles using SiPMs + LYSO scintillating crystals, with a time resolution of ∼30 ps. This thesis describes several R&D tests that have been performed for characterizing the sensor properties (time resolution, light yield, etc.) and optimizing the sensor design geometry. This thesis also contains a description of mock test setups for cooling the sensors, since it is known to be an effective way of mitigating the increased dark current rates in the sensors due to radiation damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the size of experimental channels of the lead slowing-down spectrometer SVZ-100 (Institute for Nuclear Research, Moscow) on the moderation constant

Lead slowing-down (LSD) spectrometers have a low energy resolution (about 30%), but their luminosity is 10{sup 3} to 10{sup 4} times higher than that of time-of-flight (TOF) spectrometers. A high luminosity of LSD spectrometers makes it possible to use them to measure neutron cross section for samples of mass about several micrograms. These features specify a niche for the application of LSD spectrometers in measuring neutron cross sections for elements hardly available in macroscopic amounts-in particular, for actinides. A mathematical simulation of the parameters of SVZ-100 LSD spectrometer of the Institute for Nuclear Research (INR, Moscow) is performed in the present study on the basis of the MCNPX code. It is found that the moderation constant, which is the main parameter of LSD spectrometers, is highly sensitive to the size and shape of detecting volumes in calculations and, hence, to the real size of experimental channels of the LSD spectrometer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

R-MATRIX ANALYSIS of 232Th NEUTRON TRANSMISSIONS and CAPTURE CROSS SECTIONS in the ENERGY RANGE THERMAL to 4 keV

Neutron resonance parameters of 232Th were obtained from the Reich-Moore SAMMY analysis of high-resolution neutron transmission measurements performed at the Oak Ridge Electron Linear Accelerator (ORELA) by Olsen in 1981, along with the high-resolution neutron capture measurements performed in 2005 at the Geel Linear Accelerator (GELINA, Belgium) by Schillebeeckx and at the n-TOF facility (CERN, Switzerland) by Aerts. The ORELA data were analyzed previously by Olsen with the Breit-Wigner multilevel code SIOB, and the results were used in the ENDF/B-VI evaluation. In the new analysis of the Olsen neutron transmissions by the modern computer code SAMMY, better accuracy is obtained for the resonance parameters by including in the experimental data base the recent experimental neutron capture data. The experimental data base and the method of analysis are described in the report. The neutron transmissions and the capture cross sections calculated with the resonance parameters are compared to the experimental values. A description is given of the statistical properties of the resonance parameters. The new evaluation results in a decrease in the capture resonance integral and improves the prediction of integral thermal benchmarks.

232 Th NeutronTransmission↗

Method for improving the angular resolution of a neutron scatter camera

An instrument that will directly image the fast fission neutrons from a special nuclear material source wherein the neutron detection efficiency is increased has been described. Instead of the previous technique that uses a time-of-flight (TOF) between 2 widely spaced fixed planes of neutron detectors to measure scatter neutron kinetic energy, we now use the recoil proton energy deposited in the second of the 2 scatter planes which can now be repositioned either much closer together or further apart. However, by doubling the separation distance between the 2 planes from 20 cm to a distance of 40 cm we improved the angular resolution of the detector from about 12.degree. to about 10.degree.. A further doubling of the separation distance to 80 cm provided an addition improvement in angular resolution of the detector to about 6.degree. without adding additional detectors or ancillary electronics. The distance between planes also may be dynamically changed using a suitable common technique such as a gear- or motor-drive to toggle between the various positions. The angular resolution of this new configuration, therefore, is increased at the expanse of detection sensitivity. However, the diminished sensitivity may be acceptable for those applications where the detector is able to interrogate a particular site for an extended period.

47 OTHER INSTRUMENTATION↗

Understanding Measurement Artifacts Causing Inherent Cation Gradients in Depth Profiles of Perovskite Photovoltaics with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from the hybrid organic-inorganic perovskite solar cells (PSCs) in one dimension (standard depth profiling), two dimensions (high-resolution 100-nm imaging), as well as three dimensions (tomography combining high-resolution imaging with depth profiling). We have very recently developed thermo-mechanical methods to cleave perovskite samples at the back transparent conducting oxide/PSC interface. This allowed for depth-profiling from the back of the device to the front. The resultant profiles answered the lingering question of the apparent A-site cation gradient typically seen in TOF-SIMS depth profiles. In fact, this gradient is a measurement artifact due to beam damage that the community should be informed of as TOF-SIMS data become more commonly employed. Methods of mitigating this artifact by altering the measurement conditions are also presented.

14 SOLAR ENERGY↗

A MRPC prototype for SOLID-TOF in Jlab

A prototype of Multi-gap Resistive Plate Chamber (MRPC) for the future SoLID time of flight system at JLab has been developed. The counter, trapezoidal in shape, is assembled with the newly developed low-resistive Chinese glass. It has 10 × 0.25 mm gas gaps and 11 readout strips of different lengths. The strip width is 2.5 cm with a strip-to-strip interval of 3 mm. Preliminary tests performed with cosmic-rays showed an efficiency higher than 95% and a time resolution around 50 ps. Results under diffuse/uniform irradiation performed at JLab with scattered high energy electrons showed a time resolution of 70–80 ps and over-95% efficiency up to an incoming flux of 15 kHz/cm{sup 2}. These performances meet the requirements of the new time of flight system SoLID-TOF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DSP Algorithms for Fission Fragment and Prompt Fission Neutron Spectroscopy

Digital signal processing (DSP) algorithms are in high demand for modern nuclear fission investigation due to importance of increase the accuracy of fissile nuclear data for new generation of nuclear power stations. DSP algorithms for fission fragment (FF) and prompt fission neutron (PFN) spectroscopy are described in the present work. The twin Frisch-grid ionization chamber (GTIC) is used to measure the kinetic energy-, mass- and angular distributions of the FF in the {sup 252}Cf(SF) reaction. Along with the neutron time-of-flight (TOF) measurement the correlation between neutron emission and FF mass and energy is investigated. The TOF is measured between common cathode of the GTIC and the neutron detector (ND) pulses. Waveform digitizers (WFD) having 12 bit amplitude resolution and 100 MHz sampling frequency are used for the detector pulse sampling. DSP algorithms are developed as recursive procedures to perform the signal processing, similar to those available in various nuclear electronics modules, such as constant fraction discriminator (CFD), pulse shape discriminator (PSD), peak-sensitive analogue-to-digital converter (pADC) and pulse shaping amplifier (PSA). To measure the angle between FF and the cathode plane normal to the GTIC a new algorithm is developed having advantage over the traditional analogue pulse processing schemes. Algorithms are tested by comparing the numerical simulation of the data analysis of the {sup 252}Cf(SF) reaction with data available from literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution Fission Fragment Spectroscopy with Superconducting Microcalorimeters

Sub-1 AMU mass determination is important for determining fission yields and neutron multiplicity, which are necessary inputs for fission models. Fission models can improve spent nuclear waste stream analysis and nuclear fuel burnup determination. Here, to achieve this goal, we have used superconducting microcalorimeter detectors to directly measure the energy of fission fragments from the spontaneous fission of 252 Cf. With a fiber coupled LED pulser setup we demonstrate that we can reach a relative energy resolution of 0.1% and better for photon pulses with energies above 60 MeV. This instrument, in conjunction with time-of-flight (TOF) measurement, would allow for sub-1 atomic mass unit (AMU) mass determination of fission fragments in a future beamline application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Spin on Photoemission Spectroscopy

The electronic spin degree of freedom is of general fundamental importance to all matter. Understanding its complex roles and behavior in the solid state, particularly in highly correlated and magnetic materials, has grown increasingly desirable as technology demands advanced devices and materials based on ever stricter comprehension and control of the electron spin. However, direct and efficient spin dependent probes of electronic structure are currently lacking. Angle Resolved Photoemission Spectroscopy (ARPES) has become one of the most successful experimental tools for elucidating solid state electronic structures, bolstered by-continual breakthroughs in efficient instrumentation. In contrast, spin-resolved photoemission spectroscopy has lagged behind due to a lack of similar instrumental advances. The power of photoemission spectroscopy and the pertinence of electronic spin in the current research climate combine to make breakthroughs in Spin and Angle Resolved Photoemission Spectroscopy (SARPES) a high priority . This thesis details the development of a unique instrument for efficient SARPES and represents a radical departure from conventional methods. A custom designed spin polarimeter based on low energy exchange scattering is developed, with projected efficiency gains of two orders of magnitude over current state-of-the-art polarimeters. For energy analysis, the popular hemispherical analyzer is eschewed for a custom Time-of-Flight (TOF) analyzer offering an additional order of magnitude gain in efficiency. The combined instrument signifies the breakthrough needed to perform the high resolution SARPES experiments necessary for untangling the complex spin-dependent electronic structures central to today's condensed matter physics.

36 MATERIALS SCIENCE↗