Search NASA⌕ Search

SEARCH · Search NASA

Results for “TURBINES - BLADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Wind Turbine Main Bearing Rating Lives as Determined by IEC 61400-1 and ISO 281

This presentation studies the rating lives of wind turbine main bearings, as determined by the IEC 61400-1 and ISO 281 standards. A brief review of relevant bearing life theory and turbine design requirements is provided. This includes a discussion on possible shortcomings, including the existence (or not) of the bearing fatigue load limit and the validity of assuming linear damage accumulation. A detailed study is then undertaken to determine rating lives for two models of main bearing in a 1.5 MW wind turbine. Rating life assessment is carried out under different conditions, including various combinations of main bearing temperature, wind field characteristics, lubricant viscosity and contamination levels. Rating lives are found to be sufficiently above the desired 20 year design life for both bearing models under expected operating conditions. For the larger bearing, operational loads are shown to be below or close to the bearing fatigue load limit a vast majority of the time. Key sensitivities for rating life values are shown to be the temperature and contamination. Overall, the results of this study suggest that rating life assessment does not account for reported rates of main bearing failures in 1 to 3 MW wind turbines. In future work, it is recommended that efforts be undertaken to identify principal root causes of main bearing failures, possibly leading to a new application standard specific to this component. It is also recommended that impacts of partial wake impingement on main bearing rating lives are investigated.

ENGINEERING,WIND ENERGY↗

Wind Turbine Maintenance Costs: Assessing the Potential of Gear Oil Improvements

Wind turbine operations & maintenance (O&M) costs constitute a sizable portion of total energy cost for wind power. There are many components in a utility-scale wind turbine that need to be lubricated with either oil or grease. This study uses gearbox oil as an example and assesses how lubricant technology improvements may impact wind turbine power production and levelized cost of energy. Using the modeling tools (i.e., WOMBAT, reV, and SAM) developed at National Renewable Energy Laboratory and lubrication oil technology scenarios defined based on inputs provided by ExxonMobil and industry stakeholders, we quantify the potential for increasing energy production and reducing maintenance costs across the current and future U.S. fleet of wind turbines as a result of improvements in lubrication technologies. The modeled improvements reduce the median levelized cost of energy by 1-2% across the U.S. fleet. Cumulative saving from gear oil technology improvements in 2050 for U.S. fleet is estimated to be approximately $6 billion. Extending the lubricant replacement interval has a larger impact on total cost and energy production than reducing lubricant cost.

costs↗

Design of high-deflection foils MHK applications - CFD models - Helical turbines

The Ocean Renewable Power Company's (ORPC's) goal is to design, develop, and test hydrofoils with large deflections. The effects of the deflections on cross-flow turbine performance would be evaluated in order to inform design considerations for full-scale water turbines and other marine hydrokinetic devices. CFD models of helical model scale turbines tested at UNH OpenFOAM v1912 Tip Speed Ratio (TSR) = 3.00 Different strut configurations

16 TIDAL AND WAVE POWER↗

Design of high-deflection foils MHK applications - FEA models - Helical turbines

The Ocean Renewable Power Company's (ORPC's) goal is to design, develop, and test hydrofoils with large deflections. The effects of the deflections on cross-flow turbine performance would be evaluated in order to inform design considerations for full-scale water turbines and other marine hydrokinetic devices. FEA models - NASTRAN Helical foil turbines tested at UNH tow tank Glass and carbon composite material properties Loads derived from CFD models

16 TIDAL AND WAVE POWER↗

Hydrodynamic Analysis and Optimization of Aquantis Marine Turbine: Cooperative Research and Development (Final Report)

The primary aim of this proposal is to improve the accurate prediction of hydrodynamic performance and dynamic load responses of the AQ10 floating axial-flow tidal turbine with a tri-cat mooring configuration. The validation of reduced-order modeling approaches with high-fidelity model will be implemented. Additionally, the frequency response domain, Response Amplitude Floating Wind (RAFT) toolbox plus an optimizer expanded for marine hydrokinetic turbines under the Submarine Hydrokinetic And Riverine Kilo-megawatt. Systems (SHARKS) program will be used for designing and exploring different key design parameters (platform dimension, mooring layout and its parameters) of next marine hydrokinetic (MHK) turbine generation.

16 TIDAL AND WAVE POWER↗

2020 Awardee of Two Small Wind Turbine Certification and Listing Awards: QED

With support from the Competitiveness Improvement Project's Small Wind Turbine Certification and Listing awards, QED Wind Power LLC will expand their ability to manufacture and distribute their 20-kilowatt, small wind turbine model to larger national markets. QED Wind Power aims to achieve this by conducting and completing testing of their small wind turbine and achieve safety and performance certification and listing with support from the National Renewable Energy Laboratory. This fact sheet provides an overview of QEDWind Power's project, how the company will achieve the goals of the two awards, and how the project fits within the overall Competitiveness Improvement Project.

CIP↗

2021 Small Turbine Certification Awardee: Intergrid LLC

Currently, there are no U.S., fully certified inverters for wind turbines in the 10-15-kilowatt (kW) range. The federal government's Competitiveness Improvement Project (CIP) and Small Business Innovation Research programs present the most viable paths for manufacturers in the distributed wind energy industry to conduct research, develop their products, and, ultimately, commercialize them. Through CIP, Intergrid LLC is reducing the cost, size, and weight of its legacy inverter for distributed wind turbines while increasing efficiency, reliability, and serviceability. To accomplish this, Intergrid will address three areas related to power electronics for distributed wind turbines: (1) Software verification and functional safety certification; (2) Simulation for grid-interconnecting testing; (3) Component alternatives that reduce cost and improve reliability and serviceability. The first two areas relate to long-term management of inverter software, which, for grid-connected inverters, must comply with three standards - one issued by Underwriters Laboratories (UL) and two issued by the Institute of Electrical and Electronics Engineers.

CIP↗

How many offshore wind turbines does New England need?

The proliferation of countries and regions with 100% clean or renewable energy targets necessitates an analysis to determine the number of generating units and storage needed to meet real-time electricity demand on the electric grid. The coastal areas of New England have the capacity to produce a large percentage of the region's energy needs with offshore wind turbines. Here we model offshore wind turbine power production data using MERRA-2 reanalysis and lidar wind speed data sets. We compare this power production to the New England hourly grid demand over the course of one year. 2,000 10 MW offshore wind turbines could satisfy New England's grid demand for about 37% of the year. When combined with 55 GWh of storage, 2,000 turbines could satisfy grid demand for about 72% of the year.

17 WIND ENERGY↗

Design space exploration and decision‐making for a segmented ultralight morphing 50‐MW wind turbine

Abstract Wind turbine design encompasses many different aspects including aerodynamic, structural, electrical, and control system design. To achieve optimal plant performance, a system design approach is utilized in which the performance of the whole wind turbine is evaluated and quantified during operational scenarios with subsystem interactions. In this paper, the design for a Segmented Ultralight Morphing Rotor (SUMR) 50‐MW wind turbine is presented utilizing levelized cost of energy (LCOE) for design choices, with additional quantification of simulated performance shortcomings at the 50‐MW scale. The multi‐disciplinary design process results in a final ultra‐scale turbine configuration that outperforms other existing offshore wind farms regarding the LCOE.

Kianbakht, Sepideh↗

Beyond 15 MW: A cost of energy perspective on the next generation of drivetrain technologies for offshore wind turbines

Leading wind turbine manufacturers are racing to build larger and more powerful offshore machines. Drivetrain configurations often use a permanent-magnet synchronous generator (PMSG), in either a direct-drive configuration or coupled to a gearbox. With increasing demand for critical rare-earth magnets, new generator technologies are emerging to ensure a stable and secure supply chain. We evaluate three different topologies of radial flux synchronous generators employing high field magnets with reduced or no rare-earth content: a direct-drive interior PMSG (DD-IPMSG), a geared drivetrain combining a medium speed gearbox with a PMSG (MS-PMSG), and a direct-drive low-temperature superconducting generator (DD-LTSG). We develop a conceptual design module for each of these technologies within a larger framework for full turbine design. This provides the fairest comparison between technologies at nominal power ratings from 15-25 MW, which represent the next generation of offshore wind turbines. The analyses show that if operational expenditures (OpEx) are constant across the technologies, MS-PMSG results in the lowest LCOE with reductions of up to 7% relative to DD-IPMSG. DD-LTSG also yields lower LCOE values by 2%-3% for fixed-bottom turbines and 3%-5% with a floating platform. However, results are sensitive to OpEx assumptions, with a mere 10% increase causing the conclusions to shift.

17 WIND ENERGY↗

Modification of wind turbine wakes by large-scale, convective atmospheric boundary layer structures

In this study, we consider the impact of large-scale, convective structures in an unstable atmospheric boundary layer on wind turbine wakes. Simulation data from a high-fidelity large-eddy simulation (LES) of the AWAKEN wind farm site matching unstable atmospheric conditions were analyzed, and both turbine performance and wake behavior were affected based on their location relative to the convective structures. Turbines located in updraft regions of the flow experienced lower inflow velocity and generated less power, but their wakes were observed to recover faster and saw greater turbulent kinetic energy mixing higher in the boundary layer. The opposite effect was found for turbines in the downdraft regions of the convective structures. A simplified model of this wake behavior was also developed based on a two-dimensional k–ε Reynolds-Averaged Navier–Stokes formulation. This simplified model included the effects of vertical transport, but could be efficiently solved as a parabolic system, and was found to capture similar wake modifications observed in the high-fidelity LES computations.

16 TIDAL AND WAVE POWER↗

Design Guidelines for Deployable Wind Turbines for Defense and Disaster Response Missions

Access to on-site electrical energy is critical to ensuring a successful military or humanitarian response to conflicts and disasters. These missions typically rely on access to liquid fuel that could be vulnerable to disruption or attack during transport. Generating power on location with wind technology—whether at a contingency base or disaster response coordination point—can reduce this risk and enhance mission reach by diversifying energy sources. Common characteristics of these missions are short planning and execution time horizons and a global scope of potential locations. Compared to conventional wind turbine applications, defense and disaster response applications place a premium on rapid shipping and installation, short-duration operation (days to months), and quick teardown upon mission completion. These design drivers depart from features found in conventional distributed wind turbines, thus necessitating unique design guidance. The supporting information for this guidance comes from available relevant references, technical analyses, and input from industry and military stakeholders. This paper serves as a summary of the full report, Design Guidelines for Deployable Wind Turbines for Military Operational Energy Applications (Sandia report SAND2021-14581 R [1]), which presents the best currently available design guidance for deployable wind turbines to facilitate the effective development and acquisition of technology solutions to support mission success.

17 WIND ENERGY↗

Using intrusive approaches as a step towards accounting for stochasticity in wind turbine design

Current wind turbine design methods require tens of thousands of time-domain simulations and use different random seeds to account for the stochasticity of the environmental conditions. The account of stochasticity is nonintrusive because the sampling method calls a deterministic model multiple times without changing its underlying equations. In this work, we investigate and demonstrate using simple proof of concepts how intrusive approaches can be used to directly account for stochasticity in the equations representing a mechanical system. Our long term goal is to apply such methodology to the design of wind turbines without requiring an excessive number of simulations. Intrusive methods manipulate stochastic variables directly to provide the probability density functions (PDFs) of the states and outputs at any time as functions of the PDFs of the inputs. We illustrate how different methods can be used with a reduced-order model of a wind turbine with one degree of freedom and for linear and nonlinear models. We discuss how the methods can be extended and what it will take to apply them to a level of fidelity similar to current state-of-the-art wind turbine design tools.

17 WIND ENERGY↗

Digital Twin-Enabled Adaptive Control for Hydroelectric Systems: Turbine Governor and Voltage Regulation

This paper presents a comprehensive digital twin (DT) framework for hydroelectric systems that enables adaptive control of turbine governors and excitation systems without requiring detailed manufacturer specifications. The proposed framework integrates neural network-based system identification with stabilizing adaptive control laws for the installed turbine controller and middle-branch adaptive tuning for the installed voltage regulator. Using real operational data from Unit C-8 at Rocky Reach Dam (1,349 MW capacity), highfidelity neural network models are developed to capture turbine and generator dynamics without requiring detailed manufacturer specifications. The DT enables safe controller synthesis and validation in simulation before deployment. For turbine control, the proposed method achieves a 79.9% mean square error (MSE) reduction compared with that of an optimal controller. For voltage regulation, the adaptive excitation controller achieves approximately 42.6% MSE reduction while preserving installed protection logic. The results demonstrate that DT technology provides a practical pathway for modernizing hydropower control systems with minimal operational disruption.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)↗

Valuation of Distributed Wind Turbines Providing Multiple Market Services

The role of wind turbines has traditionally been limited to providing energy capacity to the grid, but the availability of smart inverters and recent regulatory changes provide the technical and policy capability for wind turbines to also provide ancillary services. However, in contrast to the technical and policy aspects, the valuation of distributed wind turbines providing such services has not been thoroughly studied. This paper presents an optimal market-participation method for distributed wind turbines and valuates different strategies in California Independent System Operator’s balancing area. The services include energy capacity, regulation up and down, and reserves. An optimization problem is formulated to determine optimal power output for each service and demonstrated using historical data for one complete year. The revenues from multiple services are quantified, and a sensitivity analysis is performed to relate market prices with revenues. It is found that the optimal strategy generates 6% more revenue compared to the revenue from participating in the energy market only. Also, the reduced energy prices in future scenarios increase the relative importance of market participation in ancillary services.

Bhatti, Bilal Ahmad↗

Blackstart Capability and Survivability of Wind Turbines with Fully Rated Converters

We report the blackstart capability of wind turbines is critical for the recovery of wind-dominant power systems from blackouts. If wind power plants are not able to restore a power system, the incorporation of wind resources into electric grids could be limited by blackstart capability. This paper tackles this problem by setting forth a grid-forming controller for Type 4 wind turbines which employ fully rated power converters. To this end, we engineer two-axis anti-windup proportional-integral regulators that serve to ride through restoration disturbances. We also design an active protection system to prevent wind turbines from stalling during recovery from blackouts. We demonstrate in a high-fidelity simulation environment that Type 4 wind turbines with the developed controllers and protection subsystem can: (i) re-energize a notional wind-dominant grid; (ii) ride through asymmetrical faults; and (iii) survive low wind speed events.

17 WIND ENERGY↗

Loads on a Jacket-Supported Wind Turbine During Hurricane Sandy Simulation

Abstract The dynamic response of a jacket-supported offshore wind turbine under coupled wind, wave, and current fields during Hurricane Sandy is the subject of this study. To illustrate the detailed procedure related to the response evaluation of a 5-MW offshore wind turbine with a jacket support structure, we consider a single site where the water depth is 50 m. Loads are computed using two simulation tools, fast and abaqus, with partial coupling. Aerodynamic loads on the turbine rotor are first evaluated using a wind turbine model in fast with a fixed base; then, these rotor aerodynamic loads are applied as point loads at the top of a model of a tower that is supported by a jacket structure in abaqus. On the basis of stochastic simulations, we discuss the applicability of the abaqus jacket modeling and describe the characteristics and comparisons of the aerodynamic and hydrodynamic effects on loads on the jacket members. Details related to the structural model and soil–pile interaction model employed in the analyses are also discussed.

Engineering↗

Characterizing Flow Instabilities During Transient Events in the Turbine Rim Seal Cavity

Abstract Gas turbine engine design requires considerations not only for long-term steady operation but also for critical transient events. Aircraft engines undergo significant stress during takeoff and landing, while power generation turbines must be flexible for hot restarts as renewable energy sources come online and offline. During these transient cycles, engines sustain wear and degradation that can lead to a reduction in the lifespan of their components and more frequent, costly maintenance. Cooling flows are often used to mitigate these effects, but can lead to complex and problematic flow interactions. This study uses high-frequency response pressure probes and heat flux gauges in the rim seal cavity of a one-stage research turbine to characterize the properties of large-scale flow structures during transient operation. A continuous-duration turbine testing facility provides the ability to assess the importance of these transients by first reaching steady-state operation before imposing transient behaviors. Although previous studies have conducted similar measurements for steady purge flows and wheel speeds, varying these parameters to simulate transient effects revealed several unique phenomena not identifiable with discrete steady measurements. The measurement approach connects the varied transient parameter to the behavior of the flow structures to enable a better understanding of the type of instability observed and the root cause of its formation. In particular, a relationship between instability cell formation and rim sealing effectiveness was identified using experimental data and was supported through computational simulations.

Engineering↗