Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology Transfer commercialization of technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

206 records · Page 12

NPP Simulators for Coupled Thermal and Electric Power Dispatch

The Light Water Reactor Sustainability (LWRS) program within the United States Department of Energy supports extending the operation of the U.S. commercial nuclear power plant (NPP) fleet. Within the LWRS program, the Flexible Plant Operation and Generation (FPOG) Pathway works to diversify the revenue streams of light water reactors (LWRs) by opening opportunities for the co-generation of non-electric products in addition to supplying electrical power to the grid. Recent events have added greater motivation to these efforts. For example, the recent Inflation Reduction Act (IRA) passed by the U.S. federal government offers substantial tax incentives for producing clean hydrogen, the technology readiness level of dispatchable and high-efficiency hydrogen production has dramatically increased in a short time, and societal response to world climate change is driving a transition away from fossil fuels. Producing hydrogen with maximum efficiency using nuclear power requires dispatching both electrical and thermal power from the nuclear plant to the hydrogen plant, so testing concepts of operations for combined electrical and thermal power dispatch (TPD) from an NNP to a hydrogen plant is of interest. This report documents achievement of the Light Water Reactor Sustainability (LWRS) program milestone “Install and demonstrate a vendor-developed simulator on the Human Systems Simulation Laboratory (HSS) for dispatch of LWR electrical power to a close-coupled electrolysis plant” with a due date of Dec. 22, 2022. Several factors provide motivation for this effort. Coupling the power generation deck of a nuclear power plant to a hydrogen production facility introduces new possibilities for operational transients that must be addressed. In particular, the performance of the integrated system during startup and shutdown of the hydrogen production facility, as well as offnormal conditions, need to be evaluated to ensure there are no adverse effects on the operation of the existing NPP. The concept of operations involving the NPP, the hydrogen plant, and the electric power grid must be tested using NPP simulators and operating procedures that have been modified for TPD operations. These tests must also include dynamic simulations of the coupled tertiary thermal and electric loads as well as coordinated activities with NPP operators, tertiary load operators and grid power coordinators. The report summarizes progress in developing and testing full-scope NPP simulators at the HSSL, including a generic BWR simulator from GSE Systems, Inc. and generic PWR simulator from Westinghouse. In the case of the TPD-GBWR Simulator from GSE Systems, Inc., a BWR is thermally coupled to a high temperature electrolysis (HTE) plant that produces hydrogen and oxygen from de-ionized water. The hydrogen plant is not explicitly simulated but only included as a transient heat sink. A thermal power dispatch (TPD) system transfers heat between the steam systems at the BWR and the hydrogen plant. Operational results from two versions of the modified simulator are presented. The first version uses synthetic oil as a heat transfer fluid in a closed delivery heat loop (DHL) that generates steam at the hydrogen plant. The second version uses steam as the heat transfer fluid in a delivery steam line (DSL) to provide steam to the hydrogen plant. For both versions, the estimated thermal power delivery distance is approximately one kilometer. The amount of thermal power dispatched in the simulators is 15% of the total reactor thermal power such that the simulators provide a tool to study the feasibility of coupling a BWR to industrial processes that benefit from a combination electrical and thermal power dispatch. Ongoing work within a CRADA is also developing a full-scope PWR simulator provided by Westinghouse for both thermal and electric power coupling. This simulator is based on a PWR plant with two three-loop Westinghouse reactors. Westinghouse PWRs are sufficiently similar that a simulator of a three-loop reactor is an appropriate representation for two-loop and four-loop PWR reactors. The three-loop simulator will initially be modified for close-coupling to a 100 MW HTE hydrogen production plant that will require approximately 25 MW of thermal power while operating at its maximum rated capacity. The simulator testing will include full coupling to dynamic simulations of a hydrogen production plant and a representative bulk electric grid. The simulator provided by Westinghouse is similar to the GPWR simulator that INL has already obtained from GSE Systems but has a few important added benefits. First, the Westinghouse simulator is based on digital controls and has additional screens that can be called up to show parameter trends to assist operators in decision-making. The Westinghouse simulator also has upgrades to the controls and hardware representations, such as valve actuators, that make it more realistic and flexible in terms of accurately sim

99 GENERAL AND MISCELLANEOUS↗

Challenging Common Assumptions of Thick-Wall Chamber Dynamics in Inertial Fusion Systems Using MOOSE-based Multiphysics Simulations

As an increasing number of companies look toward commercial Inertial Fusion Energy (IFE) designs, there is a pressing need to understand the physics of thick-wall chamber gas dynamics. The thick liquid wall approach implements a renewable wall to mitigate the fusion target emissions, thereby reducing the radiation damage rate and significantly extending the lifetime of chamber structures, leading to increased plant availability and reduced waste streams in comparison to dry wall chamber designs. It is necessary, however, to assess the critical performance and safety aspects of these systems. For example, it is crucial to predict (1) where the mass ablated from the liquid walls will vent, which determines the placement of condensing surfaces; (2) debris propagation up the beam lines, which provides essential information for design and protection requirements; (3) peak pressures and impulse on chamber walls, which affect chamber structural design; and (4) momentum transfer to the liquid jets, which constrains the shape and positioning of the jets. In turn, the chamber design and its liquid walls affect shielding requirements, material activation, and tritium fuel cycle. Currently available simulation tools, however, are unable to accurately capture key thick-wall chamber dynamics. Significant assumptions are often made to simplify the system and reduce computational cost and modeling capability needs, but the impact of these assumptions on simulation predictions has not been evaluated. For example, no three-dimensional simulations can be found in the open literature to evaluate gas venting and momentum transfer to the jets with simulations using two-dimensional domains to represent complex three-dimensional geometries. Moreover, limited studies have been dedicated to jet breakup due to both turbulence and neutron heating, and no studies have been found that evaluate how jet breakup can impact shock-jet interaction. Furthermore, effects of radiative heat transfer have rarely been included for the hydrodynamic phase of shock propagation, and integration of proper equations of state in shock dynamics codes has been mostly exploratory. In this study, we use the flexible, high-fidelity Multiphysics Object-Oriented Simulation Environment (MOOSE) to model these complex phenomena and inform design and safety studies. Capabilities to model thick-wall chamber gas dynamics are being developed, and the impact of the assumptions listed above (i.e., two-dimensional vs three-dimensional, absence of jet breakout, no radiative heat transfer, and ideal gas behavior) are being quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Challenging Common Assumptions of Thick-Wall Chamber Dynamics in Inertial Fusion Systems using MOOSE

As an increasing number of companies look toward commercial Inertial Fusion Energy (IFE) designs, there is a pressing need to understand the physics of thick-wall chamber gas dynamics. The thick liquid wall approach implements a renewable wall to mitigate the fusion target emissions, thereby reducing the radiation damage rate and significantly extending the lifetime of chamber structures, leading to increased plant availability and reduced waste streams in comparison to dry wall chamber designs. It is necessary, however, to assess the critical performance and safety aspects of these systems. For example, it is crucial to predict (1) where the mass ablated from the liquid walls will vent, which determines the placement of condensing surfaces; (2) debris propagation up the beam lines, which provides essential information for design and protection requirements; (3) peak pressures and impulse on chamber walls, which affect chamber structural design; and (4) momentum transfer to the liquid jets, which constrains the shape and positioning of the jets. In turn, the chamber design and its liquid walls affect shielding requirements, material activation, and tritium fuel cycle. Currently available simulation tools, however, are unable to accurately capture key thick-wall chamber dynamics. Significant assumptions are often made to simplify the system and reduce computational cost and modeling capability needs, but the impact of these assumptions on simulation predictions has not been evaluated. For example, no three-dimensional simulations can be found in the open literature to evaluate gas venting and momentum transfer to the jets with simulations using two-dimensional domains to represent complex three-dimensional geometries. Moreover, limited studies have been dedicated to jet breakup due to both turbulence and neutron heating, and no studies have been found that evaluate how jet breakup can impact shock-jet interaction. Furthermore, effects of radiative heat transfer have rarely been included for the hydrodynamic phase of shock propagation, and integration of proper equations of state in shock dynamics codes has been mostly exploratory. In this study, we use the flexible, high-fidelity Multiphysics Object-Oriented Simulation Environment (MOOSE) to model these complex phenomena and inform design and safety studies. Capabilities to model thick-wall chamber gas dynamics are being developed, and the impact of the assumptions listed above (i.e., two-dimensional vs three-dimensional, absence of jet breakout, no radiative heat transfer, and ideal gas behavior) are being quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

Using Digital and Web-Based Platforms to Enhance Nuclear Power Plant Knowledge Transfer - 20203

As the workforce ages, the loss of experienced personnel can result in a loss of important knowledge. Updating Electric Power Research Institute (EPRI) research and guidance with the latest technology developments and operating experience is an important method to transfer knowledge between the retiring and incoming workforce. Studies suggest that the incoming workforce is accustomed to using digital and/or internet-based platforms to find information and may have a higher comfort with these types of platforms than they have with static, written reports. Additionally, the ease and speed of updating and delivering content through digital formats may offer an effective method for knowledge transfer and combining information from multiple reports into a single access point. EPRI has recently produced an online Decommissioning Hub available to members and is working on replicating the effort in the area of radioactive waste management called the Radwaste Web References. EPRI has extensive guidance in both disciplines. The Decommissioning Hub uses a wiki format to provide a platform that allows for both the updating of that guidance resulting from new research and new operating experiences, and combining related topical information from multiple reports. It also allows users to access the information based on key words and topical searches, and can be a tool for users to input experience to share with others. The Decommissioning Hub is accessed via a web-based portal and includes topical pages; experience summaries; a question and answer capability; and a smart search function of all EPRI decommissioning reports. Use of a wiki format allows users to input new experiences or modify existing experience summaries to add additional detail. EPRI moderates all content. The experience data base has been initially populated with information available in published EPRI reports and unpublished information currently available within EPRI. Moving forward, population of the database will continue with information available within the open literature, new information developed from current decommissioning projects, and user inputs. The web site became active in late 2017, and a major update will be issued in early 2020. Larger scale updates are planned biannually, and smaller-scale updates will occur continuously. Capturing and applying lessons learned from industry experiences is a hallmark of the global nuclear industry. This is even more important in the decommissioning technology area since very few plant staff have relevant experience and thus there is a steep learning curve. Moreover, decommissioning involves a number of complex, non-routine and specialized tasks. The web-accessible and searchable experience database provides an easy-to-use resource for capturing and disseminating practical experiences from completed and ongoing decommissioning projects. The EPRI Radwaste Web References will build upon the philosophy and objectives of the Radwaste Desk References that were published in the 1990's. The purpose of the original Radwaste Desk References was to provide nuclear power plant professionals with a how-to manual for managing radioactive waste. The Radwaste Web References will adopt this original purpose and will be a wiki type web site that provide fundamental practical and theoretical information, operating experience (OE), and information about advanced technologies and methods. As much as practicable, features that allow for interaction between users to share OE, best practices, and benchmarking will be added. Where they exist and are appropriate, the various EPRI Guidelines documents on radwaste topics will be updated and incorporated into the Radwaste Web References. The first Radwaste Web Reference will be on Low Level Waste Characterization and will build upon the EPRI Low Level Waste Characterization Guidelines (EPRI Report TR-107201, 1996) and will be available in 2020. The next Radwaste Web Reference will be on the topic of liquid radioactive waste processing and management, tentatively set for unveiling in 2021. This paper summarizes the EPRI's previous experiences with web-based platforms and future plans in this area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Novel Framework for Performance Evaluation and Design Optimization of PCM Embedded Heat Exchangers for the Built Environment

This research sheds light on the performance evaluation and design optimization of PCM-HXs for the built environment, addressing several barriers to practical issues to PCM-HX commercialization such as modeling aspects (i.e., modeling expertise and computational / time investment, etc.), manufacturing aspects (i.e., at-scale manufacturing, cost assessments, etc.) and experimental performance assessment (i.e., reliable experimental data, assessment of multiple PCM-working fluid combinations, etc.). We present a novel, comprehensive, and experimentally-validated design optimization framework for PCM-HXs capable of simulating any PCM-HX geometry with reasonable accuracy and significant computational time savings when compared to traditional CFD-based design practices. The framework was validated for a wide range of PCM-HX configurations, including a design optimization for a domestic hot water heater application where TES partially replaces electrical heating input. The resulting PCM-HXs were found to deliver 34-68% of the total daily hot water supply with only 5-10% package volume increase from the water heater, thus within U.S. DOE targets for TES systems. To identify the most promising HXs for PCM applications, first-order geometry and cost analyses were conducted based on off-the-shelf HX products. As part of this work, 9 PCM-HX prototypes were manufactured using additive and conventional manufacturing methods. Detailed economy-of-scale assessments were conducted for the most promising PCM-HXs and were found to have a good outlook for the next 5-10 years. The PCM-HX design optimization framework was validated through comprehensive in-house experimental testing using newly-developed PCM-to-fluid test facilities. In total,10 total in-house component-level experiments were conducted using these prototypes, including 9 with water and 1 with refrigerant (R410A) as the working fluid. It was found that the framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time without manual design changes, eliminating the need for time-consuming and expensive prototyping efforts as part of the design process. As part of this work, a publicly-available PCM web tool was released which includes a PCM property database (531 PCMs) and PCM-HX modeling tool to assist the design community on common PCM-HX use-cases, e.g., single/multiple flow path(s) fluid-to-PCM and air-to-fluid-to-PCM configurations (https://ceeeweb.umd.edu/pcmapp/). This work will accelerate the design and time to market for next generation PCM-HXs.

25 ENERGY STORAGE↗