Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Energy Storage Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Testing and Modeling of Subscale Ice-on-Coil Module as Low Temperature Reservoir for sCO2 based Pumped Thermal Energy Storage Systems

Echogen tested approximately 10 kWthsubscale IOC system in their lab in Akron, OH for studying the feasibility, endurance and performance impact of the technology on PTES system. This paper discusses the test loop setup, testing and results from this sub-scale IOC testing. Along with testing, the project team also developed sub-scale IOC transient model. The paper discusses this transient model development and its validation against the test data.

Avadhanula, Vamshi Krishna [Echogen Power Systems ↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Experimental study on a novel three-phase absorption thermal battery with high energy density applied to buildings

Buildings contribute to 75% of total electricity consumption and 80% of peak electricity demand in the United States. A significant portion of building electricity consumption goes to space conditioning. Therefore, using thermal energy storage (TES) to decouple the building electricity consumption and the fluctuating space-conditioning load has significant potential to shift peak electricity demand and improve the stability of the grid. To provide effective TES within the spatial constraints in buildings, a three-phase absorption thermal battery (TATB) system with very high energy storage density was designed and studied. The TATB stores low-temperature heat in hydrate crystals of salts and supports space conditioning through absorption systems. In this study, a benchtop TATB using lithium chloride (LiCl) hydrate crystals as the storage material was tested under practical operating conditions for its energy storage density and discharge rate. We report the TATB successfully generated LiCl hydrate crystals during charging mode and then dissolved the crystals during discharging mode. A material-based energy storage density of 300 kWh/m 3 (specific energy of 903 kJ/kg) was achieved with a discharge rate of up to 1.3 kW thermal energy. The test results verified the high performance of the TATB and encouraged further development of this technology.

25 ENERGY STORAGE↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP↗

Experimental apparatus and methodology to test and quantify thermal performance of micro and macro-encapsulated phase change materials in building envelope applications

Thermal energy storage (TES) is used as a viable technology to shift peak electricity demand caused by the space cooling requirements in buildings. Passive TES is implemented in building envelope via micro and macroencapsulation methods. This study describes the use of a state-of-the-art laboratory to test different PCM inclusions in simplified building walls. A microencapsulated PCM and two macroencapsulated PCMs are tested in a controlled environment to gather data for validation purposes of PCM modelling algorithms in building energy modelling programs. Data indicates that the chamber environment and the heating and cooling system can conduct full-cycle tests of wall panels with PCM inclusions. This study also generates data from parallel tests on 4 wall panels which can be used in building energy modelling programs to validate the PCM modelling algorithms. The cyclic tests also capture the thermal effects of PCMs and complex PCM behaviors like sub-cooling in PCM hydrate-salts.

25 ENERGY STORAGE↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing geothermal/solar hybridization – Integrating a solar thermal topping cycle into a geothermal bottoming cycle with energy storage

Geothermal and concentrating solar power (CSP) technologies typically use heat at different temperatures in their commercial deployments. This enables a technically viable hybridization of a solar topping cycle and a geothermal bottoming cycle at locations where both resources are available. In this article, an underperforming geothermal power system based at Burley, Idaho is used as a baseline to investigate the technical and economic potential of such a hybrid cycle. A direct thermal energy storage (TES) system is also integrated to overcome the intermittency of the solar resource. Design and off-design behavior of key components are modelled to simulate the annual performance of the hybrid system on an hourly basis. The sizing of the solar field and thermal storage is investigated and is seen to significantly impact the annual electricity generation and efficiency. Various cost scenarios for the solar field and thermal energy storage are investigated. An economic metric - levelized cost of electricity (LCOE) - is used to optimize the solar field sizing and TES capacity. The hybrid plant converts the additional solar heat input into additional work with an efficiency of 32.9%. Retrofitting a geothermal plant with solar and eight hours of energy storage can achieve an LCOE of 0.136 $/kWhe in current cost scenarios and 0.081 $/kWhe in a future cost reduction scenario. Although the hybrid system cannot directly compete with current PV systems without batteries, it has an LCOE 32% lower than that of a PV-battery system. This paper provides insights into the research and development of the future grid with a high renewable energy penetration and encourages further study of energy hybridization for improved efficiencies and economics.

15 GEOTHERMAL ENERGY↗

The Energy Transition: Advanced Nuclear Needed but Address Climate Vulnerabilities Now

The term “Energy Transition” is an attempt to capture an elaborate set of activities related to the modernization and decarbonization of energy grids. Performed concurrently and often in an ad hoc manner across local, state, regional and national boundaries, it is bringing chaos to what should arguably be one of the most conservatively managed of all critical infrastructure sectors. What’s more, with climate change producing an increasing tempo of extreme events, confidence in the intended resilient and redundant structure of the electric grids is likely to ebb. Even without these climate induced stressors, the nation’s electric grid was built for an earlier century. In addition to a drive towards greater efficiency via digitization and a continuing price decline in distributed energy resources (DERs), one could argue that climate change concerns are the primary driver of the energy transition. Non-CO2 emitting generation sources like wind and solar have become an important part of the overall generation fleet, albeit ones that cannot be counted upon to provide dispatchable power. Current projections indicate deployment of even larger percentages of DERs in coming years. Until far better storage capabilities arrive, the variability of wind and solar, inconsistent performance of traditional thermal generation plants, and energy delivery failures associated with natural gas pipelines will reinforce mounting reliability concerns. This pertains to both electric transmission and distribution. The recent shuttering of nuclear power plants in Germany, Japan, the US and elsewhere are also putting more downward pressure on dispatchable generation. Russia’s attack on Ukraine has roiled energy markets worldwide and forced some countries to return to coal as a primary fuel. In view circumstances such as these, it is essential that significant changes be made to policies and planning criteria, and to the standards and code on which they are based. Given the accelerating pace of extreme weather events, this needs to occur as soon as possible.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geological Thermal Energy Storage Using Solar Thermal and Carnot Batteries: Techno-Economic Analysis: Preprint

Energy storage is increasingly necessary as Variable Renewable Energy (VRE) technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal energy storage (GeoTES) is proposed as a solution for long-term energy storage. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. In this article, we describe a techno-economic model that has been developed to evaluate GeoTES systems. The models are developed by combining the output of specialist models which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models are developed so that the performance can be evaluated at each hour of the year. GeoTES can be charged with two different energy sources: (1) concentrating solar thermal and (2) renewable electricity using heat pumps (henceforth known as a "Carnot Battery"). The stored thermal energy can be used to generate electricity and - uniquely - also directly produce heat that can be used by industrial processes. Furthermore, Carnot-Battery-GeoTES can also be used to form a cold storage reservoir. Preliminary results that quantify the technical and economic performance of these two GeoTES systems are presented.

carnot battery↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrochemical energy storage systems for solar thermal applications

Existing and advanced electrochemical storage and inversion/conversion systems that may be used with terrestrial solar-thermal power systems are evaluated. The status, cost and performance of existing storage systems are assessed, and the cost, performance, and availability of advanced systems are projected. A prime consideration is the cost of delivered energy from plants utilizing electrochemical storage. Results indicate that the five most attractive electrochemical storage systems are the: iron-chromium redox (NASA LeRC), zinc-bromine (Exxon), sodium-sulfur (Ford), sodium-sulfur (Dow), and zinc-chlorine (EDA).

Krauthamer, S.↗

Analysis of Solar-Heated Thermal Wadis to Support Extended-Duration Lunar Exploration

The realization of the renewed exploration of the moon presents many technical challenges; among them is the survival of lunar-surface assets during periods of darkness when the lunar environment is very cold. Thermal wadis are engineered sources of stored solar energy using modified lunar regolith as a thermal storage mass that can supply energy to protect lightweight robotic rovers or other assets during the lunar night. This paper describes an analysis of the performance of thermal wadis based on the known solar illumination of the moon and estimates of producible thermal properties of modified lunar regolith. Analysis has been performed for the lunar equatorial region and for a potential outpost location near the lunar south pole. The calculations indicate that thermal wadis can provide the desired thermal energy and temperature control for the survival of rovers or other equipment during periods of darkness.

Balasubramaniam, R.↗

Analysis of Solar-Heated Thermal Wadis to Support Extended-Duration Lunar Exploration

The realization of the renewed exploration of the Moon presents many technical challenges; among them is the survival of lunar-surface assets during periods of darkness when the lunar environment is very cold. Thermal wadis are engineered sources of stored solar energy using modified lunar regolith as a thermal storage mass that can supply energy to protect lightweight robotic rovers or other assets during the lunar night. This paper describes an analysis of the performance of thermal wadis based on the known solar illumination of the Moon and estimates of producible thermal properties of modified lunar regolith. Analysis has been performed for the lunar equatorial region and for a potential outpost location near the Lunar South Pole. The calculations indicate that thermal wadis can provide the desired thermal energy and temperature control for the survival of rovers or other equipment during periods of darkness.

Balasubramaniam, R.↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage (FTES) in Crystalline Rock Formations (DEMO-FTES) (CRADA Final Report)

The DEMO-FTES project sought to demonstrate the thermal efficiency of fracture thermal energy storage (FTES) through numerical simulations, laboratory and meso-scale field tests. A detailed dimensional and scaling analysis was performed to identify key parameters and how they can be most effectively scaled to the laboratory and decameter scale. Numerical models were developed and used for three purposes: 1. Before field experiments, numerical modelling can be used to estimate fracture properties based on previous data from the EGS Collab experiment and then predict thermal hydrological behaviors of the fracture system with hot water injection/withdrawal, therefore, help to design the experiments (e.g., to decide the duration of the cycles based on the flow rate the pump can provide, and the estimated fracture properties); 2. After the field experiment, to estimate the system properties during the experiment (as the size and shape of a fracture could change over time), and understand why system performance is different than what has been predicted, i.e., to help understand the meso-scale test; and, 3. To model the lab experiments and estimate fracture properties and storage efficiency. Ultimately, the experiment and numerical models could shed light on the processes and uncertainty happening during fracture activation and help understand the scaling between lab and field test, and finally, the design and optimization of potential fracture thermal energy storage systems.

25 ENERGY STORAGE↗

Measuring the maximum capacity and thermal resistances in phase-change thermal storage devices

Thermal energy storage can increase the efficiency of the electric grid by adding flexibility to thermal systems. The value of thermal storage is a function of its energy and power density, which are driven by the capacity and thermal resistances in the storage device. Measuring these properties in-situ at the device level is an important step to understanding the performance and improving the design of thermal storage systems. Here, we present methods to measure the total capacity and thermal resistances in heat exchangers with integrated phase change materials. These methods are demonstrated on two thermal storage devices - a 570-kWh ice-based storage tank and a 0.35-kWh graphite-tetradecane composite device. The results show how thermal resistances evolve with the state of charge and discharge rate in these devices and quantify the impact of applied pressure on the contact resistance in composite phase change material heat exchangers. The proposed method allows for easy comparison between different systems and provides information on the thermal bottlenecks limiting performance. Ultimately, these measurements will allow designers to make robust, high-performance thermal storage devices for next-generation thermal systems.

25 ENERGY STORAGE↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Efficient Hydraulic-to-electric Energy Conversion for PCM-based Ocean Thermal Gradient Energy System to Power Uncrewed Underwater Vehicles

Since the 2000, there have been numerous investigations into electrical energy storage types that use ocean thermal-to-electricity conversion techniques. Field tests have demonstrated that this technology is feasible for UUVs with long-term missions of over 3,000 km per deployment. Nonetheless, the energy generated by this method is not sufficient to meet the energy requirements of Unscrewed Underwater Vehicles (UUVs). The objective of this study is to design a highly effective ocean thermal gradient energy system to support long-term missions of a UUV. To enhance the performance of the thermal gradient energy system, we have developed a hybrid type (buoyancy regulation and electrical storage). Phase Change Material (PCM)-based energy harvesting system to facilitate efficient UUV operations. A prototype of the hydraulic-to-electric conversion system was implemented, and experimental findings indicate that the hybrid system successfully delivers hydraulic energy for buoyancy change and improved efficiency of hydraulic-to-electric energy conversion, demonstrating its potential as a promising technology for supporting long-term UUV missions.

Deng, Zhiqun↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗