Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A target for production of radioxenons

A liquid cesium target has been developed which permits the production and identification of the neutron deficient isotopes of xenon. The thick target yields of Xe-127 and Xe-129 m were measured for proton energies between 28 and 40 MeV. Production of Xe-129 m, as indicated by the presence of a 196 keV line in the gamma ray spectra, occurred at all proton energies; Xe-127 was produced at proton energies above 33 MeV. Both accumulated on the target with the same time constant, and the cross sections were comparable in magnitude. The radioxenons were removed from the target by a stream of carrier gas so that chemical separation was unnecessary.

Blue, J. W.↗

Rotor Re-Design for the SSME Fuel Flowmeter

The present report describes the process of redesigning a new rotor for the SSME Fuel Flowmeter. The new design addresses the specific requirement of a lower rotor speed which would allow the SSME operation at 1 15% rated power level without reaching a blade excitation by the wakes behind the hexagonal flow straightener upstream at frequencies close to the blade natural frequency. A series of calculations combining fleet flowmeters test data, airfoil fluid dynamics and CFD simulations of flow patterns behind the flowmeter's hexagonal straightener has led to a blade twist design alpha = alpha (radius) targeting a kf constant of 0.8256. The kf constant relates the fuel volume flow to the flowmeter rotor speed, for this particular value 17685 GPM at 3650 RPM. Based on this angle distribution, two actual blade designs were developed. A first design using the same blade airfoil as the original design targeted the new kf value only. A second design using a variable blade chord length and airfoil relative thickness targeted simultaneously the new kf value and an optimum blade design destined to provide smooth and stable operation and a significant increase in the blade natural frequency associated with the first bending mode, such that a comfortable margin could be obtained at 115% RPL. The second design is a result of a concurrent engineering process, during which several iterations were made in order to achieve a targeted blade natural frequency associated with the first bending mode of 1300 Hz. Water flow tests preliminary results indicate a kf value of 0.8179 for the f-irst design, which is within 1% of the target value. The second design rotor shows a natural frequency associated with the first bending mode of 1308 Hz, and a water-flow calibration constant of kf 0.8169.

Marcu, Bogdan↗

Craters formed in mineral dust by hypervelocity microparticles.

As a simulation of erosion processes on the lunar surface, impact craters were formed in dust targets by 2- to 5-micron-diameter polystyrene spheres with velocities between 2.5 and 12 km/sec. For weakly cohesive, thick targets of basalt dust with a maximum grain size comparable to the projectile diameter, the craters had an average projectile-to-diameter diameter ratio of 25, and the displaced mass was 3 orders of magnitude greater than the projectile mass. In a simulation of the effect of a dust covering on lunar rocks, a layer of cohesive, fine-grained basalt dust with a thickness nearly twice the projectile diameter protected a glass substrate from damage, but an area about 50 times the cross-sectional area of the projectile was cleared of all but a few grains. Impact damage was produced in glass under a thinner dust layer.

Vedder, J. F.↗

An experimental study of energy dependence of saturation thickness of multiply scattered gamma rays in binary alloys

The present measurements are carried out to investigate the multiple scattering of 662 keV gamma photons emerging from targets of binary alloys (brass and soldering material). The scattered photons are detected by 51 mm × 51 mm NaI(Tl) scintillation detector whose response unscrambling converting the observed pulse–height distribution to a true photon energy spectrum, is obtained with the help of 10 × 10 inverse response matrix. The numbers of multiply scattered events, having same energy as in the singly scattered distribution, first increases with target thickness and then saturate. The application of response function of scintillation detector does not result in any change of measured saturation thickness. Monte Carlo calculation supports the present experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross-sections for 43 Sc, 44 m Sc, and 44 g Sc from two heavy ion reactions

Two different heavy ion reactions were used to produce 43 Sc (t$_{\frac12}$ = 3.891 h), 44g Sc (t$_{\frac12}$ = 4.042 h), and 44m Sc (t$_{\frac12}$ = 58.61 h) among other stable or long-lived chemically separable products. Production cross sections for 19 F + 27 Al and the reverse kinematic reaction 35 Cl + nat B were measured using an MC-SNICS ion source and the Notre Dame FN Tandem Accelerator. 19 F beams from 35 to 60 MeV were produced with beam currents between 40–80 pnA and 35 Cl beams were produced at six entrance energies with comparable beam currents. This work reports nuclear reaction cross sections 27 Al ( 19 F, x) 43 Sc, 27 Al ( 19 F, pn) 44g Sc, and 27 Al ( 19 F, pn) 44m Sc at six energies between 35 and 60 MeV lab energy. Cross sections within the same energy range were measured for 27 Al ( 19 F, 3pn) 42 K and 27 Al ( 19 F, 3p) 43 K. Comparative measurements were performed for the same compound nucleus produced from nat B( 35 Cl, x) 43 Sc, nat B( 35 Cl, pn) 44g Sc, and nat B( 35 Cl, pn) 44m Sc. The measured thin target cross sections show an overestimation by several statistical models for the scandium radioisotopes. This is corroborated by the measured thick target production rates for both entrance channels. This may be due to angular momentum effects of a heavy ion entrance channel compared to light-ion production, but additional work is required to understand this discrepancy. Finally, these measurements demonstrate that the medically useful 43 Sc, 44g Sc, and 44m Sc radioisotopes can be free of the long-lived contaminant 46 Sc without the use of enriched targets, using heavy ion beams and robust target materials.

07 ISOTOPE AND RADIATION SOURCES↗

Enhanced laser absorption from radiation pressure in intense laser plasma interactions

The reflectivity of a short-pulse laser at intensities of 2 x 10 21 Wcm -2 with ultra-high contrast (10 -15 ) on sub-micrometer silicon nitride foilswas studied experimentally using varying polarizations and target thicknesses. Furthermore, the reflected intensity and beam quality were found to be relatively constant with respect to intensity for bulk targets. For submicron targets, the measured reflectivity drops substantially without a corresponding increase in transmission, indicating increased conversion of fundamental to other wavelengths and particle heating. The experimental results and trends we observed in 3D particle-in-cell simulations emphasize the critical role of ion motion due to radiation pressure on the absorption process. Ion motion during ultra-short pulses enhances the electron heating, which subsequently transfers more energy to the ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A simple solution to the problem of effective utilisation of the target material for pulsed laser deposition of thin films

The factors determining the efficiency of the target material utilisation for pulsed laser deposition of films are considered. The target volume is calculated, which is evaporated in the ablation process by the focused laser radiation having a rectangular form. The new device is suggested and developed for obtaining thin films by the method of laser deposition, which is specific in the employment of a simple optical system mounted outside a deposition chamber that comprises two lenses and the diaphragm and focuses the laser beam onto a target in the form of a sector-like spot. Thin films of CuO and YBaCuO were deposited with this device. Several deposition cycles revealed that the target material is consumed uniformly from the entire surface of the target. A maximal spread of the target thickness was not greater than ±2% both prior to deposition and after it. The device designed provides a high coefficient of the target material utilisation efficiency. (laser deposition of thin films)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of nuclear interaction cross sections towards neutron-skin thickness determination

The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of 12 C on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R 3 B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.

Astronomy & Astrophysics↗

Accelerator-Based Studies of Heavy Ion Interactions Relevant to Space Biomedicine

Evaluation of the effects of space radiation on the crews of long duration space missions must take into account the interactions of high energy atomic nuclei in spacecraft and planetary habitat shielding and in the bodies of the astronauts. These heavy ions (i.e. heavier than hydrogen), while relatively small in number compared to the total galactic cosmic ray (GCR) charged particle flux, can produce disproportionately large effects by virtue of their high local energy deposition: a single traversal by a heavy charged particle can kill or, what may be worse, severely damage a cell. Research into the pertinent physics and biology of heavy ion interactions has consequently been assigned a high priority in a recent report by a task group of the National Research Council. Fragmentation of the incident heavy ions in shielding or in the human body will modify an initially well known radiation field and thereby complicate both spacecraft shielding design and the evaluation of potential radiation hazards. Since it is impractical to empirically test the radiation transport properties of each possible shielding material and configuration, a great deal of effort is going into the development of models of charged particle fragmentation and transport. Accurate nuclear fragmentation cross sections (probabilities), either in the form of measurements with thin targets or theoretical calculations, are needed for input to the transport models, and fluence measurements (numbers of fragments produced by interactions in thick targets) are needed both to validate the models and to test specific shielding materials and designs. Fluence data are also needed to characterize the incident radiation field in accelerator radiobiology experiments. For a number of years, nuclear fragmentation measurements at GCR-like energies have been carried out at heavy ion accelerators including the LBL Bevalac, Saturne (France), the Synchrophasotron and Nuklotron (Dubna, Russia), SIS-18 (GSI, Germany), the Alternating Gradient Synchrotron at Brookhaven National Laboratory (BNL AGS) and the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan. Until fairly recently most of these experiments were done to investigate fundamental problems in nuclear physics, but with the increasing interest in heavy charged particles on the part of the space flight, radiobiology and radiotherapy communities, an increasing number of experiments are being directed at these areas. Some of these measurements are discussed in references therein. Over the past several years, our group has taken cross section and fluence data at the AGS and HIMAC for several incident beams with nuclear charge, Z, between 6 and 26 at energies between 290 and 1050 MeV/nucleon. Iron (Z = 26) has been studied most extensively, since it is the heaviest ion present in significant numbers in the GCR. Targets have included tissue-equivalent and proposed shielding materials, as well as a variety of elemental targets for cross section measurements. Most of the data were taken along the beam axis, but measurements have been made off-axis, as well. Here we present selected data and briefly discuss some implications for spacecraft and planetary habitat design.

Miller, J.↗

Quantifying resonance behavior in the fusion of O 17 with C 12 at above-barrier energies

Recent measurement of the fusion excitation function for 17 O + 12 C reported the significant suppression of the fusion cross section at E c.m. ≈ 14 MeV. This suppression was hypothesized to signal the existence of a 16 O + n + 12 C molecular configuration. Using the active-target detector MuSIC@Indiana provided an effective means of reexamining the fusion excitation function for 17 O + 12 C.The accuracy of this thick-target measurement is strengthened through comparison with the thin-target measurement of the excitation function for 17 F + 12 C. Furthermore, the result provides important information about the dependence of the average fusion cross section for the oxygen isotopic chain on neutron excess.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The analytic model of a laser-accelerated plasma target and its stability

A self-consistent kinetic theory of a laser-accelerated plasma target with distributed electron/ion densities is developed. The simplified model assumes that after an initial transition period the bulk of cold ions are uniformly accelerated by the self-consistent electric field generated by hot electrons trapped in combined ponderomotive and electrostatic potentials. Several distinct target regions (non-neutral ion tail, non-neutral electron sheath, and neutral plasma bulk) are identified and analytically described. It is shown analytically that such laser-accelerated finite-thickness target is susceptible to Rayleigh-Taylor (RT) instability. Particle-in-cell simulations of the seeded perturbations of the plasma target reveal that, for ultra-relativistic laser intensities, the growth rate of the RT instability is depressed from the analytic estimates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-Energy Nuclear Reactions In Low-Temperature Dense Plasmas

We report the Li+d reaction with liquid Li target and the D+D reaction in liquid Li with ultrasonic cavitation. The screening potential of the Li+d reaction has been deduce from the thick target yields of alpha particles emitted in the {sup 6}Li(d,alpha){sup 4} He reaction in the solid and liquid phase. The deduced screening potential for the liquid Li is about 180 eV larger than for the solid. This difference is considered to attributed to the effect of liquefied Li{sup +} ions. It is found out that the D+D reaction in liquid Li with ultrasonic cavitation is enhanced very much; the enhancement corresponds to effective energy increase of about 2000 eV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of charged pion cross section in proton carbon interaction at 30 GeV with the NA61/SHINE apparatus

Among other goals, the NA61/SHINE (SHINE {identical_to} SPS Heavy Ion and Neutrino Experiment) detector at CERN SPS aims at precision hadro-production measurements to characterise the neutrino beam of the T2K experiment at J-PARC. These measurements are performed using a 30 GeV proton beam produced at the SPS with a thin carbon target and a full T2K replica target. Preliminary spectra of {pi}{sup -} and {pi}{sup +} inclusive inelastic cross section were obtained from pilot data collected in 2007 with a 2 cm thick target (4% of the interaction length). After a description of the SHINE detector and its particle identification capabilities, results from three different analysis are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics of jet structures formed in the plasma corona during the irradiation of porous targets by intense laser pulses

Jet structures formed during laser irradiation of porous targets with an average density of {rho} = 1-30 mg/cm{sup 3} were studied experimentally by using the diagnostic complex of the Mishen facility. To study complicated plasma structures, the experimental data were processed using specially elaborated mathematical methods. The probability of the emergence of jet plasma structures in plane open-pore triacetate cellulose targets was studied as a function of the parameter {rho}d, where {rho} is the average mass density and d is the target thickness. Analysis of the experimental results and their comparison with the existing data on the jet structures formed during laser irradiation of solid-density targets allowed the authors to reveal the characteristic features and mechanisms of the development of large-scale plasma jets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Propagation of a short-pulse laser-driven electron beam in matter

We studied the transport of an intense electron beam produced by high intensity laser pulses through metals and insulators. Targets were irradiated at two different intensities, 10{sup 17} W/cm{sup 2} and 10{sup 19} W/cm{sup 2}, at the laser facility Xtreme Light XL-III in Beijing, a Ti:Sa laser source emitting 40 fs pulses at 800 nm. The main diagnostic was Cu-K{sub {alpha}} fluorescence imaging. Images of K{sub {alpha}} spots have been collected for those two laser intensities, for different target thickness, and for different materials. Experimental results are analyzed taking into account both collisional and collective effects as well as refluxing at the edge of the target. The target temperature is evaluated to be T{sub c} {approx} 6 eV for intensity I = 10{sup 17} W/cm{sup 2} (for all the tested materials: plastic, aluminium, and copper), and T{sub c} {approx} 60 eV in aluminium and 120 eV in titanium for intensity I = 10{sup 19} W/cm{sup 2}.

36 MATERIALS SCIENCE↗

Comparison of GEANT4 Simulations with Experimental Data for Thick Al Absorbers

Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Therefore, relatively small differences in the total proton stopping power given, for example, by the different models provided by GEANT4 can lead to significant disagreements in the final proton energy spectra when integrated along lengthy proton trajectories. This work presents proton energy spectra obtained by GEANT4.8.2 simulations using ICRU49, Ziegler1985 and Ziegler2000 models for 19.68 MeV protons passing through a number of Al absorbers with various thicknesses. The spectra were compared with the experimental data, with TRIM/SRIM2008 and MCNPX2.4.0 simulations, and with the Payne analytical solution for the transport equation in the Fokker-Plank approximation. It is shown that the MCNPX simulations reasonably reproduce well all experimental spectra. For the relatively thin targets all the methods give practically identical results but this is not the same for the thick absorbers. It should be noted that all the spectra were measured at the proton energies significantly above 2 MeV, i.e., in the so-called 'Bethe-Bloch region'. Therefore the observed disagreements in GEANT4 results, simulated with different models, are somewhat unexpected. Further studies are necessary for better understanding and definitive conclusions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast model of electron transport for radiographic spectrum simulation

Correctly modeling the continuous photon spectrum of X-ray tubes requires detailed knowledge of the probability distribution of electron properties at the time of X-ray photon creation, in particular electron energy, depth within the target, and direction of movement. Semi-analytical X-ray spectrum models frequently assume a very simplified or even uniform distribution of electron direction. In the case of thick targets and small deviations from normal incidence this is a useful approximation. For thin targets or large deviations from normal incidence the correct distribution of electron directions becomes more important. As calculation speed is an important aspect of semi-analytical models compared to Monte Carlo simulations, fast evaluation of the distribution of electron properties is highly desirable. The approach presented here numerically evaluates the evolution of a discrete probability distribution of electron properties due to single electron scatter interactions within a plane target. This allows capturing the important aspects of the electron distribution while achieving runtimes of a few seconds up to a minute on a standard office PC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduced Calibration Curve for Proton Computed Tomography

The pCT deals with relatively thick targets like the human head or trunk. Thus, the fidelity of pCT as a tool for proton therapy planning depends on the accuracy of physical formulas used for proton interaction with thick absorbers. Although the actual overall accuracy of the proton stopping power in the Bethe-Bloch domain is about 1%, the analytical calculations and the Monte Carlo simulations with codes like TRIM/SRIM, MCNPX and GEANT4 do not agreed with each other. A tentative to validate the codes against experimental data for thick absorbers bring some difficulties: only a few data is available and the existing data sets have been acquired at different initial proton energies, and for different absorber materials. In this work we compare the results of our Monte Carlo simulations with existing experimental data in terms of reduced calibration curve, i.e. the range - energy dependence normalized on the range scale by the full projected CSDA range for given initial proton energy in a given material, taken from the NIST PSTAR database, and on the final proton energy scale - by the given initial energy of protons. This approach is almost energy and material independent. The results of our analysis are important for pCT development because the contradictions observed at arbitrary low initial proton energies could be easily scaled now to typical pCT energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗