Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transformation Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Studies of erosion of solar max samples of Kapton and Teflon

Several samples of Kapton and Teflon which was exposed to solar radiation were examined. The samples represent material behavior in near Earth space. Clues to the identity of erosive processes and the responsible species were searched for. Interest centered around oxygen atoms which are ubiquitous at these altitudes and are known to erode some metal surfaces. Three diagnostic methods were employed: optical microscopy, scanning electron microscopy, and fourier transform infrared spectroscopy. Two types of simulation were used: a flow containing low energy oxygen atoms and bombardment with 3000 volt Ar ions. Results and conclusions are presented.

Fristrom, R. M.↗

Research In Optical Processing Of Data

Report describes current research in optical processing of data at NASA's Ames Research Center. Describes advanced optical feature extractor performing Fourier-Mellin transform to generate feature vector invariant under changes of scale and position and responds to rotation with simple translation. Potential advantages include high speed and low cost.

Ennis, David↗

A 850 GHz SIS receiver employing silicon micro-machining technology

A 850 GHz superconductor-insulator-superconductor (SIS) heterodyne receiver which uses a radiofrequency tuned niobium tunnel junction fabricated on a 1 micron thick silicon nitrate membrane, is reported. From video and heterodyne measurements, it was calculated that the niobium film loss in the radiofrequency matching network is about 6.8 dB at 822 GHz. These results are approximately a factor of two higher than the theoretical loss predicted by the Mattis-Bardeen theory in the extreme anomalous limit. The junction design and the receiver configuration are described, including the mixer block, the membrane construction and the cooled optics. The performance tests using a Fourier transform spectrometer to measure the response of the radiofrequency matching network, and the SIS simulations of the receiver response to cold and hot loads, the infrared noise contribution and the overall mixer conversion efficiency, are reported. It is concluded that the receiver response is limited by the absorption loss in the radiofrequency matching network.

Kooi, J. W.↗

Diffuse Reflectance Mid-Infrared Spectroscopy as a Tool for the Identification of Surface Contamination on Sandblasted Metals

The SOC 400 Surface Inspection Machine/Infrared (SIMIR) is a small, ruggedized Fourier transform infrared spectrometer having dedicated diffuse reflectance optics. The SOC 400 was designed for the purpose of detecting (qualitatively and quantitatively) oil stains on the inside surface of solid rocket motor casings in the as-sandblasted and cleaned condition at levels approaching 1 mg. sq ft. The performance of this instrument is described using spectral mapping techniques.

G. Louis Powell↗

The NASA MSFC Electrostatic Levitation (ESL) Laboratory: Summary of Capabilities, Recent Upgrades, and Future Work

The NASA Marshall Space Flight Center (MSFC) electrostatic levitation (ESL) laboratory has a long history of providing materials research and thermophysical property data. A summary of the labs capabilities, recent upgrades, and ongoing and future work will be provided. The laboratory has recently added two new capabilities to its main levitation chamber: a rapid quench system and an oxygen control system. The rapid quench system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy. Thereby allowing rapid quenching of undercooled liquid metals. The oxygen control system consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity between two gas compartments separated by an electrolyte, which is yttria-stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10-36 to 100 bar. The ESL laboratory also has an emissometer, called the High-Temperature Emissivity Measurement System (HiTEMS). This system measures the spectral emissivity of materials from 600degC to 3,000degC. The system consists of a vacuum chamber, a black body source, and a Fourier Transform Infrared Spectrometer (FTIR). The system utilizes optics to swap the signal between the sample and the black body. The system was originally designed to measure the hemispherical spectral emissivity of levitated samples, which are typically 2.5mm spheres. Levitation allows emissivity measurements of molten samples, but more work is required to develop this capability. The system is currently setup measure the near-normal spectral emissivity of stationary samples, which has been used to take measurements of ablative materials, rocket nozzle coating materials, and materials for spacecraft instruments.

SanSoucie, Michael P.↗

The Network for the Detection of Atmospheric Composition Change (NDACC): History, Status and Perspectives

The Network for the Detection of Atmospheric Composition Change (NDACC) is an international global network of more than 90 stations making high-quality measurements of atmospheric composition that began official operations in 1991 after 5 years of planning. Apart from sonde measurements, all measurements in the network are performed by ground-based remote-sensing techniques. Originally named the Network for the Detection of Stratospheric Change (NDSC), the name of the network was changed to NDACC in 2005 to better reflect the expanded scope of its measurements. The primary goal of NDACC is to establish long-term databases for detecting changes and trends in the chemical and physical state of the atmosphere (mesosphere, stratosphere, and troposphere) and to assess the coupling of such changes with climate and air quality. NDACC's origins, station locations, organizational structure, and data archiving are described. NDACC is structured around categories of ground-based observational techniques (sonde, lidar, microwave radiometers, Fourier-transform infrared, UV-visible DOAS (differential optical absorption spectroscopy)-type, and Dobson-Brewer spectrometers, as well as spectral UV radiometers), timely cross-cutting themes (ozone, water vapour, measurement strategies, cross-network data integration), satellite measurement systems, and theory and analyses. Participation in NDACC requires compliance with strict measurement and data protocols to ensure that the network data are of high and consistent quality. To widen its scope, NDACC has established formal collaborative agreements with eight other cooperating networks and Global Atmosphere Watch (GAW). A brief history is provided, major accomplishments of NDACC during its first 25 years of operation are reviewed, and a forward-looking perspective is presented.

lidar↗

Validation of Ozone Profile Retrievals Derived from the OMPS LP Version 2.5 Algorithm Against Correlative Satellite Measurements

The Limb Profiler (LP) is a part of the Ozone Mapping and Profiler Suite launched on board of the Suomi NPP satellite in October 2011. The LP measures solar radiation scattered from the atmospheric limb in ultraviolet and visible spectral ranges between the surface and 80 km. These measurements of scattered solar radiances allow for the retrieval of ozone profiles from cloud tops up to 55 km. The LP started operational observations in April 2012. In this study we evaluate more than 5.5 years of ozone profile measurements from the OMPS LP processed with the new NASA GSFC version 2.5 retrieval algorithm. We provide a brief description of the key changes that had been implemented in this new algorithm, including a pointing correction, new cloud height detection, explicit aerosol correction and a reduction of the number of wavelengths used in the retrievals. The OMPS LP ozone retrievals have been compared with independent satellite profile measurements obtained from the Aura Microwave Limb Sounder (MLS), Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) and Odin Optical Spectrograph and InfraRed Imaging System (OSIRIS). We document observed biases and seasonal differences and evaluate the stability of the version 2.5 ozone record over 5.5 years. Our analysis indicates that the mean differences between LP and correlative measurements are well within required +/- 10% between 18 and 42 km. In the upper stratosphere and lower mesosphere (>43 km) LP tends to have a negative bias. We find larger biases in the lower stratosphere and upper troposphere, but LP ozone retrievals have significantly improved in version 2.5 compared to version 2 due to the implemented aerosol correction. In the northern high latitudes we observe larger biases between 20 and 32 km due to the remaining thermal sensitivity issue. Our analysis shows that LP ozone retrievals agree well with the correlative satellite observations in characterizing vertical, spatial and temporal ozone distribution associated with natural processes, like the seasonal cycle and quasi-biennial oscillations. We found a small positive drift approx. 0.5%/yr in the LP ozone record against MLS and OSIRIS that is more pronounced at altitudes above 35 km. This pattern in the relative drift is consistent with a possible 100m drift in the LP sensor pointing detected by one of our altitude-resolving methods.

Ozone Mapping↗

Optical pulse-induced ultrafast antiferrodistortive transition in SrTiO 3

The ultrafast dynamics of the antiferrodistortive phase transition in perovskite SrTiO 3 is monitored via time-domain Brillouin scattering. Using femtosecond optical pulses, we initiate a thermally driven tetragonal-to-cubic structural transformation and detect the crystal phase through changes in the frequency of Brillouin oscillations (BO) induced by propagating acoustic phonons. Coupling the measured BO frequency with a spatiotemporal heat diffusion model, we demonstrate that, for a sample kept in the tetragonal phase, deposition of sufficient thermal energy induces a rapid transformation of the heat-affected region to the cubic phase. The initial phase change is followed by a slower reverse cubic-to-tetragonal phase transformation occurring on a timescale of hundreds of picoseconds. Here, we attribute this ultrafast phase transformation in the perovskite to a structural resemblance between atomic displacements of the R-point soft optic mode of the cubic phase and the tetragonal phase, both characterized by anti-phase rotation of oxygen octahedra. The structural relaxation time exhibits a strong temperature dependence consistent with the prediction of the equation of motion describing collective oxygen octahedra rotation based on the energy landscape of the phenomenological Landau theory of phase transitions. Evidence of such a fast structural transition in perovskites can open up new avenues in information processing and energy storage sectors.

36 MATERIALS SCIENCE↗

Highly automated optical characterization with FTIR spectrometry

The procedure for evaluating the characteristics of II-VI semiconducting infrared sensor materials with a Fourier Transform Infrared (FTIR) spectrometer system will be discussed. While the method of mapping optical characteristics with a spectrometer has been employed previously, this system is highly automated compared to other systems where the optical transmission data are obtained using a FTIR system with a small stationary aperture in the optical path and moving the specimen behind the aperture. The hardware and software, including an algorithm developed for extracting cut-on wavelengths of spectra, as well as several example results, are described to illustrate the advanced level of the system. Additionally, data from transverse slices and longitudinal wafers of the aforementioned semiconductors will be used to show the accuracy of the system in predicting trends in materials such as shapes of growth interfaces and compositional uniformity.

Perry, G. L. E.↗

The Nagoya cosmic-ray muon spectrometer 3, part 4: Track reconstruction method

One of the greatest problems in measuring particle trajectories with an optical or visual detector system, is the reconstruction of trajectories in real space from their recorded images. In the Nagoya cosmic-ray muon spectrometer, muon tracks are detected by wide gap spark chambers and their images are recorded on the photographic film through an optical system of 10 mirrors and two cameras. For the spatial reconstruction, 42 parameters of the optical system should be known to determine the configuration of this system. It is almost impossible to measure this many parameters directly with usual techniques. In order to solve this problem, the inverse transformation method was applied. In this method, all the optical parameters are determined from the locations of fiducial marks in real space and the locations of their images on the photographic film by the non-linear least square fitting.

Shibata, S.↗

Rare Earth Optical Temperature Sensor

A rare earth optical temperature sensor is disclosed for measuring high temperatures. Optical temperature sensors exist that channel emissions from a sensor to a detector using a light pipe. The invention uses a rare earth emitter to transform the sensed thermal energy into a narrow band width optical signal that travels to a detector using a light pipe. An optical bandpass filter at the detector removes any noise signal outside of the band width of the signal from the emitter.

Donald L Chubb↗

Optical Correlator With Complex Holographic Filter

Experimental real-time optical correlator includes complex-valued holographic filter computed from one of two input scenes. Made more tolerant of errors in patterns to be recognized. Filter function essentially coded hologram computed by Burchhardt's method, in which complex value of each pixel of fast Fourier transform of image represented by three real, nonnegative numbers. In generating optical correlator according to method, phasor of each pixel in Fourier transform represented by intensities in three adjacent pixels.

Chao, Tien-Hsin↗

Use of a Multiwavelength Pyrometer in Several Elevated Temperature Aerospace Applications

A multiwavelength pyrometer was developed for applications unique to aerospace environments. It was shown to be a useful and versatile technique for measuring temperature, even when the emissivity is unknown. It has also been used to measure the surface temperatures of ceramic zircomia thermal barrier coatings and alumina. The close agreement between pyrometer and thin film thermocouple temperatures provided an independent check. Other applications of the multiwavelength pyrometer are simultaneous surface and bulk temperature measurements of a transparent material, and combustion gas temperature measurement using a special probe interfaced to the multiwavelength pyrometer via an optical fiber. The multiwavelength pyrometer determined temperature by transforming the radiation spectrum in a broad wavelength region to produce a straight line (in a certain spectral region), whose intercept in the vertical axis gives the temperature. Implicit in a two-color pyrometer is the assumption of wavelength independent emissivity. Though the two data points of a two-color pyrometer similarly processed would result immediately in a similar straight line to give the unknown temperature, the two-color pyrometer lacks the greater data redundancy of the multiwavelength pyrometer, which enables it to do so with improved accuracy. It also confirms that emissivity is indeed wavelength independent, as evidenced by a multitude of the data lying on a simple straight line. The multiwavelength pyrometer was also used to study the optical transmission properties of a nanostructured material from which a quadratic exponential functional frequency dependence of its spectral transmission was determined. Finally, by operating the multiwavelength pyrometer in a very wide field of view mode, the surface temperature distribution of a large hot surface was obtained through measurement of just a single radiation spectrum.

Ng, Daniel↗

UNLOQ: UNderstanding coherence in Light-matter interfaces for Quantum Science (Final Technical Report)

The general goal of this project is to prepare next-generation quantum systems for novel quantum information science applications. Decades of research on quantum optics have provided revolutionary systems for manipulating atomic and photonic quantum coherence in transformative ways. Our hypothesis is that the next-generation quantum systems will come from nano-molecular quantum optics. Specifically, we are interested in coupling the electronic states of molecules or nanoparticles to the quantized radiation field inside an optical cavity to create a set of new photon-matter hybrid excitations, called polaritons. As opposed to atoms, the vibrational modes of molecules and nanoparticles provide new degrees of freedom to mediate the quantum transduction between electronic and photonic states, offering new ways to tune and ultimately control the quantum coherence of the integrated system. In this project we are interested in designing, fabricating, and characterizing the polaritons that arise from coupling CdSe nanoplatelets (NPLs) to a Fabry-Pérot optical cavity. Specific attention was paid to parameters of the system (cavity mode volume, quality factor, etc.) that would maximize the collective coupling strength. Through a combined theoretical and experimental approach, we were able to make important contributions to understanding NPL exciton-polariton photophysics including how to use cavity loss as a tunable parameter in order to manipulate the populations of the upper and lower polariton states. Finally, using state-of-the-art theoretical methods, we were able to show how the collective coupling of many molecular excitons in a cavity can protect polariton coherence from vibrationally-induced decoherence. In particular, for NPL-cavity polaritonic systems, the quantum coherence can be extended by over an order of magnitude at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fourier Transform Fabry-Perot Interferometer

We are developing a compact, rugged, high-resolution remote sensing instrument with wide spectral scanning capabilities. This relatively new type of instrument, which we have chosen to call the Fourier-Transform Fabry-Perot Interferometer (FT-FPI), is accomplished by mechanically scanning the etalon plates of a Fabry-Perot interferometer (FPI) through a large optical distance while examining the concomitant signal with a Fourier-transform analysis technique similar to that employed by the Michelson interferometer. The FT-FPI will be used initially as a ground-based instrument to study near-infrared atmospheric absorption lines of trace gases using the techniques of solar absorption spectroscopy. Future plans include modifications to allow for measurements of trace gases in the stratosphere using spectral lines at terahertz frequencies.

Snell, Hilary E.↗

Extracting heading and temporal range from optic flow: Human performance issues

Pilots are able to extract information about their vehicle motion and environmental structure from dynamic transformations in the out-the-window scene. In this presentation, we focus on the information in the optic flow which specifies vehicle heading and distance to objects in the environment, scaled to a temporal metric. In particular, we are concerned with modeling how the human operators extract the necessary information, and what factors impact their ability to utilize the critical information. In general, the psychophysical data suggest that the human visual system is fairly robust to degradations in the visual display, e.g., reduced contrast and resolution or restricted field of view. However, extraneous motion flow, i.e., introduced by sensor rotation, greatly compromises human performance. The implications of these models and data for enhanced/synthetic vision systems are discussed.

Kaiser, Mary K.↗

Optical remote sensing for measurement of toxic gases

There is renewed interest in using optical remote sensing techniques for measuring and monitoring airborne toxins. Many instruments have been used to measure traces of atmospheric molecular species. Some optical remote sensing technology is in use for measuring or monitoring toxic or pollutant gases. The examples in this article provide a number of lessons that may be of use in the new field of optical remote sensing of toxic gases. Topics covered include the following: atmospheric properties, Fourier transform spectrometry, gas-filter correlation, differential absorption laser systems, aircraft missions, laser long-path instruments, differential optical absorption spectrometry, and ozone measurement.

Grant, William B.↗