Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Proton Exchange Membrane Fuel Cell Transient Load Response

Spaceflight mission profiles may not be limited to constant power loads. It is necessary for the associated power system to support changes in load in addition to being energy dense. H2-O2 proton exchange membrane (PEM) fuel cells can accommodate such requirements without significant current smoothing or additional devices to provide transient power. This testing involved current load step changes to characterize non-flow-through PEM fuel cell response to increasing and decreasing load step changes over a range of 0 to 0.5 A/sq. cm. It was determined that fuel cell output voltage stabilizes within 4 ms with no noticeable steady-state performance degradation, following exposure of the fuel cell to transient loads of up to ~1.5 A/sq. cm. Faster stabilization generally occurred following larger step changes.

fuel cell↗

Transient liquid-crystal technique used to produce high-resolution convective heat-transfer-coefficient maps

In this transient technique the preheated isothermal model wall simulates the classic one-dimensional, semi-infinite wall heat transfer conduction problem. By knowing the temperature of the air flowing through the model, the initial temperature of the model wall, and the surface cooling rate measured at any location with time (using the fast-response liquid-crystal patterns recorded on video tape), the heat transfer coefficient can be calculated for the color isothermal pattern produced. Although the test was run transiently, the heat transfer coefficients are for the steady-state case. The upstream thermal boundary condition was considered to be isothermal. This transient liquid-crystal heat-transfer technique was used in a transient air tunnel in which a square-inlet, 3-to-1 exit transition duct was placed. The duct was preheated prior to allowing room temperature air to be suddenly drawn through it. The resulting isothermal contours on the duct surfaces were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the temperature and time data for all points on the duct surfaces during each test. The duct surfaces were uniformly heated using two heating systems: the first was an automatic temperature-controlled heater blanket completely surrounding the test duct like an oven, and the second was an internal hot-air loop through the inside of the test duct. The hot-air loop path was confined inside the test duct by insulated heat dams located at the inlet and exit ends of the test duct. A recirculating fan moved hot air into the duct inlet, through the duct, out of the duct exit, through the oven, and back to the duct inlet. The temperature nonuniformity of the test duct model wall was held very small. Test results are reported for two inlet Reynolds numbers of 200,000 and 1,150,000 (based on the square-inlet hydraulic diameter) and two free-stream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 20 percent (using a grid), which is typical of real engine conditions.

Hippensteele, Steven A.↗

Implementation and Testing of the First Prompt Search for Gravitational Wave Transients with Electromagnetic Counterparts

Aims. A transient astrophysical event observed in both gravitational wave (GW) and electromagnetic (EM) channels would yield rich scientific rewards. A first program initiating EM follow-ups to possible transient GW events has been developed and exercised by the LIGO and Virgo community in association with several partners. In this paper, we describe and evaluate the methods used to promptly identify and localize GW event candidates and to request images of targeted sky locations. Methods. During two observing periods (Dec. 17, 2009 to Jan. 8, 2010 and Sep. 2 to Oct. 20, 2010), a low-latency analysis pipeline was used to identify GW event candidates and to reconstruct maps of possible sky locations. A catalog of nearby galaxies and MilkyWay globular clusters was used to select the most promising sky positions to be imaged, and this directional information was delivered to EM observatories with time lags of about thirty minutes. A Monte Carlo simulation has been used to evaluate the low-latency GW pipeline's ability to reconstruct source positions correctly. Results. For signals near the detection threshold, our low-latency algorithms often localized simulated GW burst signals to tens of square degrees, while neutron star/neutron star inspirals and neutron star/black hole inspirals were localized to a few hundred square degrees. Localization precision improves for moderately stronger signals. The correct sky location of signals well above threshold and originating from nearby galaxies may be observed with ∼50% or better probability with a few pointings of wide-field telescopes.

testing↗

Long-duration firings of a Mariner Mars 1969 catalytic reactor

Two long-duration tests were conducted with a surplus Mariner Mars 1969 monopropellant hydrazine reactor in an attempt to induce the washout phenomenon. The Mariner Mars 1969 reactor was chosen because it has a long development history and thus is well characterized. No washout occurred during either of the two 1000-s tests, although slow transients were observed in the reactor operation during what were nominally steady-state conditions. The 2000-s of operating time represents nearly an order of magnitude increase over the rated life of the engine.

Price, T. W.↗

Time-dependent, non-Newtonian behavior of viscoelastic materials

A kinetic model for characterizing the shear stress or shear strain rate of thixotropic materials is developed and combined with Oldroyd's viscoelastic model (1953) modified in this paper in order to predict the first normal stress difference. In order to test the method, transient and steady state data have been obtained with a Weissenberg rheogoniometer used to measure the constant stress and constant shear rate of a solution of polymethyl methacrylate in diethylphthalate. A computer was used to facilitate data acquisition.

Jachimiak, P. D.↗

F100 multivariable control synthesis program: A review of full scale engine altitude tests

The benefits of linear quadratic regulator synthesis methods in designing a multivariable engine control capable of operating an engine throughout its flight envelope were demonstrated. The entire multivariable control synthesis program is reviewed with particular emphasis on engine tests conducted in the NASA Lewis propulsion systems laboratory altitude facility. The multivariable control has basically a proportional plus integral, model following structure with gains scheduled as functions of flight condition. The multivariable control logic design is described, along with control computer implementation aspects. Altitude tests demonstrated that the multivariable control logic could control an engine over a wide range of test conditions. Representative transient responses are presented to demonstrate engine behavior and the functioning of the control logic.

Lehtinen, B.↗

Space Shuttle main engine nozzle-steerhorn dynamics

On two occasions during the Space Shuttle main engine development, the LH2 feedline (called the steerhorn, because of its shape) failed during the cutoff transient. A dynamic test was undertaken, and an analytical model was developed and correlated to the dynamic test. Detailed models of the tube bundle were required to obtain the equivalent shell coefficients. All-shell models of the nozzle wall were found better than beam-shell models. The most difficult part of the structure to simulate was the felt-metal pad between the feedline and its mount, which introduced nonlinear stiffness and damping and led to the use of separate low amplitude and high amplitude models. The total structure was found to have 400 modes in the frequency range of interest, 0 to 500 Hz. Good test analysis correlation was obtained and a modified feedline configuration was found to demonstrate a 40% reduction of response stress from the original configuration.

Kiefling, L.↗

In-situ analysis of hydrazine decomposition products

A gas analyzer utilizing a nondispersive infrared (NDIR) detection system was used to monitor the ammonia and water vapor content of the products of a previously unused hydrazine gas generator. This provided an in-situ measurement of the generator's efficiency difficult to obtain by other means. The analyzer was easily installed in both the calibration and hydrazine systems, required no maintenance other than periodic zero adjustments, and performed well for extended periods in the operating range tested. The catalyst bed operated smoothly and repeatably during the 28 hr of testing. No major transients were observed on startup or during steady state operation. The amount of ammonia in the output stream of the gas generator was found to be a strong function of temperature at catalyst bed temperatures below 450 C. At temperatures above this, the efficiency remained nearly constant. On startup the gas generator efficiency was found to decrease with time until a steady state value was attained. Elevated catalyst bed temperatures in the periods before steady state operation was found to be responsible for this phenomenon.

Curran, Francis M.↗

In-situ analysis of hydrazine decomposition products

A gas analyzer utilizing a nondispersive infrared (NDIR) detection system was used to monitor the ammonia and water vapor content of the products of a previously unused hydrazine gas generator. This provided an in-situ measurement of the generator's efficiency difficult to obtain by other means. The analyzer was easily installed in both the calibration and hydrazine systems, required no maintenance other than periodic zero adjustments, and performed well for extended periods in the operating range tested. The catalyst bed operated smoothly and repeatably during the 28 hr of testing. No major transients were observed on startup or during steady state operation. The amount of ammonia in the output stream of the gas generator was found to be a strong function of temperature at catalyst bed temperatures below 450 C. At temperatures above this, the efficiency remained nearly constant. On startup the gas generator efficiency was found to decrease with time until a steady state value was attained. Elevated catalyst bed temperatures in the periods before steady state operation was found to be responsible for this phenomenon.

Curran, Francis M.↗

Pulse Coil Tester

Set of relays tested easily and repeatedly. Pulse coil tester causes coil under test to generate transient voltage; waveform indicates condition of coil. Tester accommodates assembly of up to four coils at a time.

Simon, Richard A.↗

Experimental studies on the tripping behavior of narrow T-stiffened flat plates subjected to hydrostatic pressure and underwater shock

An experimental investigation was conducted to determine the static and dynamic responses of a specific stiffened flat plate design. The air-backed rectangular flat plates of 6061-T6 aluminum with an externally machined longitudinal narrow-flanged T-stiffener and clamped boundary conditions were subjected to static loading by water hydropump pressure and shock loading from an eight pound TNT charge detonated underwater. The dynamic test plate was instrumented to measure transient strains and free field pressure. The static test plate was instrumented to measure transient strains, plate deflection, and pressure. Emphasis was placed upon forcing static and dynamic stiffener tripping, obtaining relevant strain and pressure data, and studying the associated plate-stiffener behavior.

Budweg, H. L.↗

Experimental and computational study of the viscoplastic response of high temperature structures

The first nine months of experimental and computational studies of the thermal-structural behavior of thin panels subjected to localized heating are described. Initial experimental studies have focused on developing an experimental set-up with well-defined thermal-structure boundary conditions. Preliminary tests with a Heldenfels panel have demonstrated out of plane bending (thermal buckling) due to panel initial imperfections. Initial computational studies have focused on: (1) validation of a thermoviscoplastic code to predict thermal stresses in the unbuckled panel, and (2) investigating in-plane stresses for test panels under transient thermal loading. Plans for future research are described.

Thornton, Earl A.↗

Application of multirate digital filter banks to wideband all-digital phase-locked loops design

A new class of architecture for all-digital phase-locked loops (DPLL's) is presented in this article. These architectures, referred to as parallel DPLL (PDPLL), employ multirate digital filter banks (DFB's) to track signals with a lower processing rate than the Nyquist rate, without reducing the input (Nyquist) bandwidth. The PDPLL basically trades complexity for hardware-processing speed by introducing parallel processing in the receiver. It is demonstrated here that the DPLL performance is identical to that of a PDPLL for both steady-state and transient behavior. A test signal with a time-varying Doppler characteristic is used to compare the performance of both the DPLL and the PDPLL.

Sadr, R.↗

Application of multirate digital filter banks to wideband all-digital phase-locked loops design

A new class of architecture for all-digital phase-locked loops (DPLL's) is presented in this article. These architectures, referred to as parallel DPLL (PDPLL), employ multirate digital filter banks (DFB's) to track signals with a lower processing rate than the Nyquist rate, without reducing the input (Nyquist) bandwidth. The PDPLL basically trades complexity for hardware-processing speed by introducing parallel processing in the receiver. It is demonstrated here that the DPLL performance is identical to that of a PDPLL for both steady-state and transient behavior. A test signal with a time-varying Doppler characteristic is used to compare the performance of both the DPLL and the PDPLL.

Sadr, Ramin↗

Transient Mathematical Modeling for Liquid Rocket Engine Systems: Methods, Capabilities, and Experience

The subject of mathematical modeling of the transient operation of liquid rocket engines is presented in overview form from the perspective of engineers working at the NASA Marshall Space Flight Center. The necessity of creating and utilizing accurate mathematical models as part of liquid rocket engine development process has become well established and is likely to increase in importance in the future. The issues of design considerations for transient operation, development testing, and failure scenario simulation are discussed. An overview of the derivation of the basic governing equations is presented along with a discussion of computational and numerical issues associated with the implementation of these equations in computer codes. Also, work in the field of generating usable fluid property tables is presented along with an overview of efforts to be undertaken in the future to improve the tools use for the mathematical modeling process.

Martin, Michael A.↗

Transient Mathematical Modeling for Liquid Rocket Engine Systems: Methods, Capabilities, and Experience

The subject of mathematical modeling of the transient operation of liquid rocket engines is presented in overview form from the perspective of engineers working at the NASA Marshall Space Flight Center. The necessity of creating and utilizing accurate mathematical models as part of liquid rocket engine development process has become well established and is likely to increase in importance in the future. The issues of design considerations for transient operation, development testing, and failure scenario simulation are discussed. An overview of the derivation of the basic governing equations is presented along with a discussion of computational and numerical issues associated with the implementation of these equations in computer codes. Also, work in the field of generating usable fluid property tables is presented along with an overview of efforts to be undertaken in the future to improve the tools use for the mathematical modeling process.

Seymour, David C.↗