At least 217 records · Page 12

Fluorescence imaging to quantify crop residue cover

Crop residues, the portion of the crop left in the field after harvest, can be an important management factor in controlling soil erosion. Methods to quantify residue cover are needed that are rapid, accurate, and objective. Scenes with known amounts of crop residue were illuminated with long wave ultraviolet (UV) radiation and fluorescence images were recorded with an intensified video camera fitted with a 453 to 488 nm band pass filter. A light colored soil and a dark colored soil were used as background for the weathered soybean stems. Residue cover was determined by counting the proportion of the pixels in the image with fluorescence values greater than a threshold. Soil pixels had the lowest gray levels in the images. The values of the soybean residue pixels spanned nearly the full range of the 8-bit video data. Classification accuracies typically were within 3(absolute units) of measured cover values. Video imaging can provide an intuitive understanding of the fraction of the soil covered by residue.

Daughtry, C. S. T.↗

The Preflight Photometric Calibration of the Extreme-Ultraviolet Imaging Telescope EIT

This paper presents the preflight photometric calibration of the Extreme-ultraviolet Imaging Telescope (EIT) aboard the Solar and Heliospheric Observatory (SOHO). The EIT consists of a Ritchey-Chretien telescope with multilayer coatings applied to four quadrants of the primary and secondary mirrors, several filters and a backside-thinned CCD detector. The quadrants of the EIT optics were used to observe the Sun in 4 wavelength bands that peak near 171, 195, 284, and 304 . Before the launch of SOHO, the EIT mirror reflectivities, the filter transmissivities and the CCD quantum efficiency were measured and these values are described here. The instrumental throughput in terms of an effective area is presented for each of the various mirror quadrant and filter wheel combinations. The response to a coronal plasma as a function of temperature is also determined and the expected count rates are compared to the count rates observed in a coronal hole, the quiet Sun and an active region.

EIT (EXTREME-ULTRAVIOLET IMAGING TELESCOPE)↗

Investigating the effect of B T direction on W source-to-core pathways during the SAS-VW campaign on DIII-D

Experiments using the V-shaped closed slot tungsten (W) coated SAS-VW divertor in DIII-D studied the effects of the BT direction on core contamination of eroded tungsten from a closed slot divertor configuration. Core W content is inferred using soft-X ray tomography (SXR) and vacuum ultraviolet spectroscopy (SPRED), while W divertor erosion is inferred from visible spectroscopy of W emission (400.9 nm) measured by in-slot filterscopes (filtered photo-multipliers). Post-mortem analysis from the campaign discovered tile misalignment leading to suspected pronounced leading-edge erosion in the unfavorable BT direction (ion B ⃗×∇B ⃗ drift away from divertor) likely not captured by diagnostics. However, empirical findings show up to ~2-3x larger core contamination in the favorable BT direction even considering no additional W erosion from leading edges. A “source-to-core efficiency factor” is derived to estimate the effects of leading-edge erosion and compare W contamination for two pairs of H-mode discharges in opposite BT directions. While having differing absolute parameters, similar core impurity density gradients suggest comparable core impurity transport. These results show that favorable BT may have stronger source-to-core pathways for W impurities sourced from the outer divertor region. Possible explanations could include the effects of E ⃗×B ⃗ drifts on W transport in the scrape-off-layer (SOL) as well as previously determined fast SOL inner target directed flows in favorable BT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra high resolution images of the solar chromosphere and corona using coordinated rocket and balloon observations

A discussion is presented of the scientific objectives that can be pursued by simultaneous coronal/chromospheric observation with the Multi-Spectral Solar Telescope Array (MSSTA), and a new balloon-borne observatory called the Ultra-High Resolution Vacuum Ultraviolet Spectroheliograph (UHRVS). Attention is given to the proposed UHRVS observatory, which will incorporate two instruments, a 65-cm aperture telescope with narrowband filters for high resolution photographic and photoelectric spectroheliograms, and a very high resolution spectrograph which uses a 40-cm aperture telescope. The capabilities of the MSSTA, and the joint UHRVS/MSSTA observing program that is envisioned are reviewed.

Walker, Arthur B. C., Jr.↗

The Fundamental Structure of Coronal Loops

During the past ten years, solar physicists have attempted to infer the coronal heating mechanism by comparing observations of coronal loops with hydrodynamic model predictions. These comparisons often used the addition of sub ]resolution strands to explain the observed loop properties. On July 11, 2012, the High Resolution Coronal Imager (Hi ]C) was launched on a sounding rocket. This instrument obtained images of the solar corona was 0.2 ]0.3'' resolution in a narrowband EUV filter centered around 193 Angstroms. In this talk, we will compare these high resolution images to simultaneous density measurements obtained with the Extreme Ultraviolet Imaging Spectrograph (EIS) on Hinode to determine whether the structures observed with Hi ]C are resolved.

Winebarger, Amy↗

An extreme ultraviolet telescope with no soft X-ray response

While EUV grazing incidence telescopes of conventional design exhibit a substantial X-ray response as well as an extreme UV response, and existing bandpass filters for the transmission of radiation longward of 400 A also transmit soft X-rays, the grazing incidence telescope presented suppresses this soft X-ray throughput through the incorporation of a Wolter Schwarzschild Type II mirror with large graze angles. The desirable features of an EUV photometric survey telescope are retained. An instrument of this design will be flown on the EUE mission, in order to make a survey of the sky at wavelengths longer than 400 A.

Finley, David S.↗

Keeping the Air Clean and Safe: An Anthrax Smoke Detector

Scientists at work in the Planetary Protection division at NASA s Jet Propulsion Laboratory (JPL) sterilize everything before blasting it to the Red Planet. They take great pains to ensure that all spacecraft are void of bacterial life, especially the microscopic bacteria that can live hundreds of years in their spore states. No one is quite sure what Earthly germs would do on Mars, but scientists agree that it is safest to keep the Martian terrain as undisturbed as possible. Errant Earth germs would also render useless the instruments placed on exploration rovers to look for signs of life, as the life that they registered would be life that came with them from Earth. A team at JPL, headed by Dr. Adrian Ponce, developed a bacterial spore-detection system that uses a simple and robust chemical reaction that visually alerts Planetary Protection crews. It is a simple air filter that traps micron-sized bacterial spores and then submits them to the chemical reaction. When the solution is then viewed under an ultraviolet light, the mixture will glow green if it is contaminated by bacteria. Scientists can then return to the scrubbing and cleaning stages of the sterilization process to remove these harmful bacteria. The detection system is the space-bound equivalent of having your hands checked for cleanliness before being allowed to the table; and although intended to keep terrestrial germs from space, this technology has awesome applications here on Mother Earth. The bacterial spore-detection unit can recognize anthrax and other harmful, spore-forming bacteria and alert people of the impending danger. As evidenced in the anthrax mailings of fall 2001 in the United States, the first sign of anthrax exposure was when people experienced flu-like symptoms, which unfortunately, can take as much as a week to develop after contamination. Anthrax cost 5 people their lives and infected 19 others; and the threat of bioterrorism became a routine concern, with new threats popping up nearly everyday. The attacks threatened the safety that so many Americans took for granted, as the very air that people breathed became suspect. Any building with a circulation system, where large groups congregate, was now a potential target.

Source record↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. XI - The 1971 eclipse of 32 Cygni

We observed the 1971 eclipse of 32 Cyg at regular intervals from November 1 to 15 with the wide-band filter photometers aboard OAO-2. Data have been reduced for seven filter bands with effective wavelengths between 4250 and 1430 A. Both the constancy of the light near mid-eclipse for the shorter wavelengths, and the derived energy distribution of the B component over all of these wavelengths indicate that the eclipse was total. The spectral types determined from the photometry of the two components are B5 and K4 Ib, after correction for interstellar reddening of 0.10 mag in B-V.

Doherty, L. R.↗

A Change in the Solar He II EUV Global Network Structure as an Indicator of the Geo-Effectiveness of Solar Minima

Solar activity during 2007 - 2009 was very low, causing anomalously low thermospheric density. A comparison of solar extreme ultraviolet (EUV) irradiance in the He II spectral band (26 to 34 nm) from the Solar Extreme ultraviolet Monitor (SEM), one of instruments on the Charge Element and Isotope Analysis System (CELIAS) on board the Solar and Heliospheric Observatory (SOHO) for the two latest solar minima showed a decrease of the absolute irradiance of about 15 +/- 6 % during the solar minimum between Cycles 23 and 24 compared with the Cycle 22/23 minimum when a yearly running-mean filter was used. We found that some local, shorter-term minima including those with the same absolute EUV flux in the SEM spectral band show a higher concentration of spatial power in the global network structure from the 30.4 nm SOHO/Extreme ultraviolet Imaging Telescope (EIT) images for the local minimum of 1996 compared with the minima of 2008 - 2011.We interpret this higher concentration of spatial power in the transition region's global network structure as a larger number of larger-area features on the solar disk. These changes in the global network structure during solar minima may characterize, in part, the geo-effectiveness of the solar He II EUV irradiance in addition to the estimations based on its absolute levels.

Solar extreme ultraviolet irradiance↗

Ultra Narrowband Optical Filters for Water Vapor Differential Absorption Lidar (DIAL) Atmospheric Measurements

Differential absorption lidar (DIAL) systems are being deployed to make vertical profile measurements of atmospheric water vapor from ground and airborne platforms. One goal of this work is to improve the technology of such DIAL systems that they could be deployed on space-based platforms. Since background radiation reduces system performance, it is important to reduce it. One way to reduce it is to narrow the bandwidth of the optical receiver system. However, since the DIAL technique uses two or more wavelengths, in this case separated by 0.1 nm, a fixed-wavelength narrowband filter that would encompass both wavelengths would be broader than required for each line, approximately 0.02 nm. The approach employed in this project is to use a pair of tunable narrowband reflective fiber Bragg gratings. The Bragg gratings are germanium-doped silica core fiber that is exposed to ultraviolet radiation to produce index-of-refraction changes along the length of the fiber. The gratings can be tuned by stretching. The backscattered laser radiation is transmitted through an optical circulator to the gratings, reflected back to the optical circulator by one of the gratings, and then sent to a photodiode. The filter reflectivities were >90 percent, and the overall system efficiency was 30 percent.

Stenholm, Ingrid↗

Theoretical simulation of solar spectra in the middle ultraviolet and visible for atmospheric trace constituent measurements

The data compiled during the study allowed a detailed examination of the attenuation of the solar radiance by the combined effect of the atmospheric trace gases and the SAGE filters. The case of the 0.44 microns channel is presented. The amounts of NO2, NO2, O3 and the airmass were chosen to closely simulate a low sun spectral scan from a 9 February 1977 balloon flight. The solar radiance outside the earth's atmosphere was determined from the AFGL Sacramento Peak Observatory spectral data tape degraded to 2.0A resolution and normalized to Thekaekara's absolute intensities. The spectral absorption coefficients used for NO2 and O3 were tabulated previously.

Goldman, A.↗

UV photography of the earth and moon

This experiment obtained imagery of the earth and the moon at a series of wavelength intervals in the near ultraviolet. These photographs were used to aid in the interpretation of the UV appearance of other planets in the solar system, especially mars and venus. The filter and film characteristics are described, as well as the ozone absorption coefficient curve.

Owen, T. C.↗

Analysis of UV protection requirements and testing of candidate attenuators for the Haloe optical instrument

Results of calculations are presented which simulate photolytic processes occurring in HALOE gas calibration cells exposed to extra-terrestrial solar ultraviolet photons. These calculations indicate that significant photolysis takes place in two of the sapphire-enclosed cells over the exposure periods of the proposed mission. A subsequent laboratory investigation is also described in which a high-voltage discharge hydrogen light source is used in conjunction with a vacuum ultraviolet spectrograph. The UV emission from this lamp was used to expose two candidate UV attenuators (ZnSe and coated Ge) to ascertain their suitability as UV filters while maintaining original infrared optical properties. Both materials were found to be effectively opaque to vacuum UV radiaton and suffered no adverse effects regarding their infrared transmissivity.

Nealy, J. E.↗

Preliminary results on interstellar reddening as deduced from filter photometry

Filter photometry has been used to derive the interstellar reddening law from stars through the study of a single spectral type, B0. The deficiency in the far ultraviolet flux of a supergiant relative to a main sequence star is compared with the difference in the flux distribution due to a change of one spectral class. Individual interstellar reddening curves show the general feature reported by Stecher (1969) and by Bless and Savage (1970). There is a large amount of scatter in the far ultraviolet which may be partially due to a real difference in interstellar extinction and partially due to observational inaccuracy.

Laget, M.↗

Ultraviolet-Blocking Lenses Protect, Enhance Vision

To combat the harmful properties of light in space, as well as that of artificial radiation produced during laser and welding work, Jet Propulsion Laboratory (JPL) scientists developed a lens capable of absorbing, filtering, and scattering the dangerous light while not obstructing vision. SunTiger Inc. now Eagle Eyes Optics, of Calabasas, California was formed to market a full line of sunglasses based on the JPL discovery that promised 100-percent elimination of harmful wavelengths and enhanced visual clarity. The technology was recently inducted into the Space Technology Hall of Fame.

Source record↗

Design of the Extreme Ultraviolet Explorer long-wavelength grazing incidence telescope optics

Designing optics for photometry in the long-wavelength portion of the EUV spectrum (400-900) A) poses different problems from those arising for optics, operating shortward of 400 A. The available filter materials which transmit radiation longward of 400 A are also highly transparent at wavelengths shortward of 100 A. Conventional EUV optics, with grazing engles of less than about 10 deg, have very high throughput in the EUV, which persists to wavelengths shortward of 100 A. Use of such optics with the longer-wavelength EUV filters thus results in an unacceptably large soft X-ray leak. This problem is overcome by developing a mirror design with larger graze angles of not less than 20 deg, which has high throughput at wavelengths longer than 400 A but at the same time very little throughput shortward of 100 A.

Finley, David S.↗

The ultraviolet imager (UVI) for ISTP

We report the design of an imager with 0.6-millirad angular resolution over an 8-deg field of view sampled with 39,500 pixels, yielding global auroral coherent imaging from above 6 R(E). High performance filters provide spectrally pure measurements of four key FUV features, with 10 exp -4 out-of-band rejection. Together with the solar blind intensified CCD detector, a net rejection of 10 exp -9 of all out-of-band emissions is achieved. The optical design comprises a three-mirror f/3 system which yields a noise equivalent sensitivity of 10 Rayleighs for a 37-sec frame rate. The instantaneous dynamic range is 1000 which can be windowed over a range of 10 exp 4.

Torr, D. G.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗