Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CASL Annual Report (FY2018)

The Consortium for Advanced Simulation of Light Water Reactors (CASL) was established in July 2010 as the first US Department of Energy (DOE) Energy Innovation Hub. The consortium was initially funded for five years to develop advanced modeling and simulation (M&S) tools that can be used to analyze issues associated with the operation of US commercial light water reactors (LWRs). During this period, the program focused primarily on capabilities to solve challenges related to pressurized water reactor (PWR) operation. In January 2015, the program was extended for an additional five years with the goal of finalizing development and deployment of CASL tools for PWR analysis and extending the program’s tools for use in small modular reactor (SMR) operation and boiling water reactor (BWR) analyses. In February 2018, the CASL program was authorized to receive additional funds to focus on the use of advanced M&S tools in a regulatory environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation and modification of ELM seasonal deciduous phenology against observations in a southern boreal peatland forest

Phenological transitions determine the timing of changes in land surface properties and the seasonality of exchanges of biosphere-atmosphere energy, water, and carbon. Accurate mechanistic modeling of phenological processes is therefore critical to understand and correctly predict terrestrial ecosystem feedbacks with changing atmospheric and climate conditions. However, the phenological components in the land model of the US Department of Energy's (DOE) Energy Exascale Earth System Model (ELM of E3SM) were previously unable to accurately capture the observed phenological responses to environmental conditions in a well-studied boreal peatland forest. In this research, we introduced new seasonal-deciduous phenology schemes into version 1.0 of ELM and evaluated their performance against the PhenoCam observations at the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experiment in northern Minnesota from 2015 to 2018. We found that phenology simulated by the revised ELM (i.e., earlier spring onsets and stronger warming responses of spring onsets and autumn senescence) was closer to observations than simulations from the original algorithms for both the deciduous conifer (Larix laricina) and mixed shrub layers. Moreover, the revised ELM generally produced higher carbon and water fluxes (e.g., photosynthesis and evapotranspiration) during the growing season and stronger flux responses to warming than the default ELM. A parameter sensitivity analysis further indicated the significant contribution of phenology parameters to uncertainty in key carbon and water cycle variables, underscoring the importance of precise phenology parameterization. Furthermore, this phenological modeling effort demonstrates the potential to enhance the E3SM representation of land-climate interactions at broader spatiotemporal scales, especially under anticipated elevated CO 2 and warming conditions.

54 ENVIRONMENTAL SCIENCES↗

PV Fleet Performance Data Initiative Program and Methodology

The US Department of Energy’s PV Fleet Performance Data Initiative has been launched in order to collect and evaluate production data across multiple PV fleet partners. Performance statistics are anonymized, aggregated and shared to represent a snapshot of the US commercial and utility-scale fleet. Production data have been collected from over 1500 systems representing more than 1.3 GWdc capacity. Preliminary analysis indicates median performance loss rates are in line with previous publications of system degradation, on the order of –0.6%/yr to –0.9%/yr (preliminary numbers subject to change). These values are higher than module-only degradation rates which are often used in pro-forma estimates of project performance and economics, potentially exposing owner/operators to increased risk if systems under-perform over time.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Sister Rod Destructive Examinations (FY23) Appendix F: Cyclic Integrated Reversible-Bending Fatigue Tests

Spent nuclear fuel (SNF) assemblies must be shipped to other sites for processing and disposal. During shipment, the fuel is typically oriented horizontally, and the fuel rods are subject to periodic alternating loads related to the movement of the vehicle that results in alternating bending of the SNF fuel rods. The number of bending cycles is related to the length of the shipping route, with longer routes producing more cycles. Because it is well-known that cyclic loads can produce failures, even when the stress and strain imposed are below the material’s yield point, investigation of the SNF’s fatigue behavior is prudent. This report discusses the results of fatigue testing conducted at Oak Ridge National Laboratory (ORNL) using the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) created by the US Department of Energy Office of Nuclear Energy for the High Burnup Spent Fuel Data Project and its sister rods. The results of the tests are compared with results obtained over the last decade using the same CIRFT for the US Nuclear Regulatory Commission (NRC).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

De-Risking Large-Scale PV Systems Through Data Analytics

Large-scale photovoltaic system performance analysis is being conducted within the US Department of Energy's-sponsored PV Fleet Performance Data Initiative. This collaboration with commercial PV system owners collects and evaluates PV field performance data, and provides reports on aggregated results. Drawing on over 2200 sites across the US and over 24,000 separate PV inverters we have collected in excess of 8.3 gigawatts (GW) of performance data, representing 6-7% of the entire US installed PV capacity. A mixture of utility-scale and large commercial systems are represented, averaging 4.1 megawatts (MW) in size and 5 years in age. Initial results show average system degradation rates at -0.75% / year, which is slightly higher than historically reported module-level values of -0.5%/year. We also found that the availability of systems averaged 97.7%, which is lower than the typical 99% uptime assumed by many project economic forecasts. Given these results, we compared monthly performance with expected production values, based on satellite weather data and a simple PVWatts performance model. We found that systems were performing within 10% of monthly expectation over 90% of the time, with a fleet average vs expected monthly value of 0.994. We also evaluated the impact of extreme weather events on system performance, and found a range of short-term and longer-term performance effects ranging from grid outage, system downtime, module damage and accelerated long-term degradation rate.

analysis↗

Sensor Impact Evaluation and Verification Technical Advisory Group Meeting Minutes

This report provides the technical advisory group meeting minutes and summary of detailed discussions for future development of sensor impact evaluations and verifications. Methods for sensor configuration/deployment have critical impacts on energy-efficient building control and thermal comfort. However, traditional sensor techniques for building operation and fault detection and diagnostics (FDD) are not optimal in terms of energy efficiency and thermal comfort, and their global effects are not thoroughly investigated. In an effort to address and overcome this limitation, a 3 year project, Sensor Impact Evaluation and Verification, was proposed. The multi-laboratory team—the US Department of Energy’s Oak Ridge National Laboratory (ORNL), Pacific Northwest National Laboratory (PNNL), and the National Renewable Energy Laboratory (NREL)—is conducting early-stage R&D to provide technical supports and guidelines for sensor design in building/HVAC systems to optimize building energy use, FDD, thermal comfort, and grid efficiency. The overall goal of this project is to develop a framework that enables quantitative evaluation of the impact of sensors on building HVAC control, FDD, and consequently, building energy efficiency and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RePOWERD: Restoration of Power Outage from Wide-area Severe Weather Disruptions

The purpose of the RePOWERD project is to develop a probabilistic and a simulation based power restoration forecasting model for tropical storms based on geographic utility service areas, impacts to energy infrastructures and transportation networks, time-varying customer outage number, crew information (i.e., crew size, crew staging requirements), and utility restoration plans. Energy infrastructure is a critical lifeline essential for the United States’ national and economic security. Like other critical infrastructures, this infrastructure is aging and is at a high risk of damages from extreme weather events. Based on the number of reported outages in EAGLE-I during 2020 and 2021, it is evident that the current energy infrastructure is not equipped to handle extreme event impacts and will contribute to significant outages. From a resilience perspective, it is essential to forecast restoration time in the event of a severe weather induced power outage to assist the US Department of Energy, emergency managers, and first responders with resource planning. This project contributes to this crucial need. This report details the models, that were developed in this pilot study, to determine the rate of restoration and estimated time of restoration (ETR) during tropical storm events within counties and utility service areas based on damage to energy infrastructures and total number of customers experiencing outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surface-based observations of cold-air outbreak clouds during the COMBLE field campaign

Abstract. Cold-air outbreaks (CAOs) are characterized by extreme air–sea energy exchanges and low-level convective clouds over large areas in the high-latitude oceans. As such, CAOs are an important component of the Earth's climate system. The CAOs in the Marine Boundary Layer Experiment (COMBLE) deployment of the US Department of Energy Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF) provided the first comprehensive view of CAOs using a suite of ground-based observations at the northern coast of Norway. Here, cloud and precipitation observations from 13 CAO cases during COMBLE are analyzed. A vertical air motion retrieval technique is applied to the Ka-band ARM Zenith-pointing Radar (KAZR) observations. The CAO cumulus clouds are characterized by strong updrafts with magnitudes between 2–8 m s−1, vertical extents of 1–3 km, and horizontal scales of 0.25–3 km. A strong relationship between our vertical air velocity retrievals and liquid water path (LWP) measurements is found. The LWP measurements exceed 1 kg m−2 in strong updraft areas, and the vertical extent of the updraft correlates well with the LWP values. The CAO cumulus clouds exhibit eddy dissipation rate values between 10−3 and 10−2 m2 s−3 in the lowest 10 km of the atmosphere, and using a radar Doppler spectra technique, evidence of secondary ice production is found during one of the cases.

54 ENVIRONMENTAL SCIENCES↗

Energy innovation in the US buildings sector: Setting the stage and mapping the future

Jared Langevin is a staff scientist at Lawrence Berkeley National Laboratory, where he leads modeling of US buildings sector innovation and its implications for energy demand, consumer costs, and the power grid. Eric Wilson is a senior research engineer in the Building Technologies and Sciences Center at the National Renewable Energy Laboratory (NREL). Much of his 15-year career at NREL has revolved around modeling and analysis of the US building stock. Jared and Eric co-led the development of a National Blueprint for buildings sector innovation while serving as advisors to the US Department of Energy’s Deputy Assistant Secretary for Buildings and Industry.

Langevin, Jared↗

DOE Challenges and Opportunities Associated with Accountable Nuclear Material Needs for Development and Commercialization of Fusion Nuclear Energy

Fusion energy represents a transformative opportunity to deliver a safe, plentiful, and carbon-free source of reliable primary power. In recent years, fusion research and development have accelerated significantly, particularly within the US, driven by decades of foundational public investment. Notably, in 2024 the US Department of Energy (DOE) established a comprehensive Fusion Energy Strategy aimed at collaborating with industry partners to enable the deployment of fusion power plants and grid integration by the 2030s. This strategy is chiefly implemented through the DOE Office of Science (SC) Fusion Energy Sciences program. This project was initiated to identify potential approaches for the Office of Environment, Safety, and Health (NA-ESH-12) within DOE’s National Nuclear Security Administration to begin engagement with the fusion community on future accountable material needs. The goal of the project is to inform and influence the supply of and demand for accountable nuclear materials as fusion energy is developed and commercialized. NA-ESH-12 must proactively engage with the fusion community regarding the production and management of accountable nuclear materials. Given the complexity and scale of materials required for research, pilot projects, and eventual commercial reactors, early coordination is vital. The project’s objective is to provide insights that will shape the supply and demand landscape for critical nuclear materials, ensuring that DOE is prepared to effectively support fusion energy development and commercialization. In FY 2025, an initial limited review was conducted to identify the status of the fusion energy community’s progress toward full-scale energy production and the need for accountable nuclear material. This included communications with SC, NA-ESH-12, Savannah River National Laboratory, and Oak Ridge National Laboratory, and attending the Rutgers University–sponsored Supply Chain Workshop: Scaling the Fusion Industry and the International Atomic Energy Agency’s Ninth DEMO Programme Workshop. The review to date indicates that the amounts of tritium, lithium-6, and deuterium required by the fusion industry will be dependent on fuel type, breeding technology, blankets, and R&D improvements. One concern is that the commercial sector does not have a sufficient supply chain to meet the demand for development and commercialization for fusion energy production. The supply and demand estimates for these materials should be routinely reviewed as fusion technologies mature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VERA neutronics high-fidelity benchmark for a modern PWR core design

Nearly 20 years since the origin of the infamous 'Kord Smith Challenge', and after 10 years and hundreds of millions of dollars invested by the US Department of Energy into the development of the Virtual Environment for Reactor Applications (VERA), the capability to accurately simulate a modern pressurized water reactor (PWR) fuel cycle at the fuel rod level with high-fidelity Monte Carlo (MC) stochastic transport methods still evades us. The deterministic methods in VERA make approximations that allow it to be successfully benchmarked against measured data from hundreds of PWR fuel cycles, but none of these benchmarks provided information at the local fuel rod level or allowed quantification of these approximations' impact for modern PWR reload designs. Using MPACT to establish the estimated isotopic distributions and thermal hydraulic conditions in a recent and challenging reactor design, a 2D quarter-core benchmark problem was established and solved consistently with both MPACT, the 51-energy group deterministic transport solver in VERA, and Shift, the continuous-energy MC transport solver in VERA. Impacts of energy groups, ray spacing, and scattering treatment were evaluated. Though MPACT has been previously shown to perform well compared to MC methods for initial Cycle 1 cores with only fresh fuel, this is the first benchmark of MPACT for a challenging modern reload core with depleted fuel and burnable absorbers. This work establishes additional credibility for the methods in MPACT and highlights the efficiency of these methods relative to those in use by MC-based tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving Hydropower Representation in Power System Models (Summary of Technical Workshop)

In March 2019, Pacific Northwest National Laboratory (PNNL) and National Renewable Energy Laboratory (NREL) held a workshop to discuss the characterization of hydropower resources within electric power system models. The workshop took place at the Western Electricity Coordinating Council in Salt Lake City, Utah, and was sponsored by the Water Power Technologies Office of the US Department of Energy. The intention of the workshop is to support the federal energy research initiative HydroWIRES. The Initiative has a specific technical objective to advance the representation of hydropower resources in relevant water and power models and to address the seams between the two. This report describes the workshop, contributions from attendees, a summary of the findings of the event and proposed next steps. The themes and recommendations from this workshop have provided foundational guidance for future research and program strategy.

13 HYDRO ENERGY↗

Precision Time Protocol Performance Testing Over Optical Transport Network

The US Department of Energy Office of Electricity has partnered with Oak Ridge National Laboratory (ORNL) to find alternative precision timing solutions for the nation’s power grid. This effort is in response to the vulnerabilities identified in the Global Navigation Satellite System (GNSS), of which the US Global Positioning System (GPS) platform is a part. Additionally, Executive Order 139055 has highlighted the need for alternative or backup timing solutions. ORNL has established a Timing Lab and has been testing various technologies and timing devices as part of this effort. Precision Time Protocol (PTP), and the off-the-shelf timing devices and network connections that support it, are among the alternatives being tested. This work reports the accuracy of PTP over an Optical Transport Network (OTN) and is part of a series published by the Center for Alternative Synchronization and Timing (CAST).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Non-Powered Dam Retrofit Exemplary Design for Hydropower Applications

Non-powered dams (NPDs) represent complex systems, situated at the intersection of natural stream environments and the built environment. The presence and operations of NPDs affect stream constituents (e.g., fish, recreational craft, sediment, water) and serve one or more engineered purposes (e.g., recreation, flood control, water supply, irrigation, tailings and debris control, navigation). By definition, NPDs do not provide hydropower generation. However, every NPD contains some untapped hydropower resource potential, represented by the pre-existing hydraulic head created by the dam and presence of flowing water. Adding power generation to an NPD requires retrofitting the NPD, which could involve the addition of any new component or function beyond that currently installed. Because this research is funded by the US Department of Energy Water Power Technologies Office, adding hydropower to NPDs is among the primary objectives for research investment. However, NPD retrofitting extends beyond the purview of hydropower additions. This report provides background information regarding NPD development in the United States, including an overview of the US NPD population, development potential, and recent development. It also summarizes challenges and opportunities facing NPD retrofit development, highlights the importance of maintaining or improving stream and dam functionality, notes key NPD characteristics, describes NPD retrofit methods, and identifies innovation areas for spurring future NPD retrofit development. Section 4 describes retrofit exemplary design principles and concepts that could apply to a wide range of NPD projects. These principles and concepts inform an NPD Retrofit Exemplary Design Specification (REDS), as included in Appendix A. The NPD REDS is heavily influenced by prior work under the standard modular hydropower technology acceleration research initiative, especially the work documented in the Exemplary Design Envelope Specification for Standard Modular Hydropower Technology (Witt et al., 2017). Whereas this prior work focuses on a particular technology class that applies most intentionally for new stream-reach development (i.e., greenfield sites), the NPD REDS contained herein applies more broadly to the NPD resource class and is technology-agnostic (i.e., the specific technologies intended to be described are not explicitly prescribed). This report serves as a part of early-phase research on NPD retrofit development, aimed toward spurring additional, follow-on efforts to specifically address development challenges, capitalize on development opportunities, and inspire innovation. As documented in the landmark “Hydropower Vision” report (DOE 2016), “transformative technical innovations able to meet the co-objectives of environmental sustainability and low-carbon energy will be critical to enabling additional hydropower growth.” This report serves as an important step in steering transformation of US non-powered dam infrastructure.

13 HYDRO ENERGY↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Institute for Catalysis in Energy Processes (ICEP) (Final Report)

The Institute for Catalysis in Energy Processes (ICEP) was a multi-PI program located at the Northwestern University Center for Catalysis and Surface Science from 2006-2024. Over several renewal cycles and several organizing themes, ICEP addressed fundamental questions in catalysis science. In turn, the scientific questions addressed were directly relevant to the efficient use of the nation’s resources to produce fuels and commodity chemicals, harness alternate energy sources for chemical reactions such as light or electricity, reduce emissions and waste, and minimize the impact of our use of plastics. Selective oxidation, (oxidative) dehydrogenation, deNOx, CO 2 reduction, hydrogen release, polymer decomposition / depolymerization, and many other reactions of intense interest to the US Department of Energy were studied in the center. Major ICEP strengths were in catalyst synthesis, in measurements that elucidated catalyst properties, in reaction mechanisms and kinetics, and in predictive theory and modeling. ICEP researchers were often the inventors or developers of materials and methods that were brought to bear on the Institute’s catalytic systems. Key characterization tools advanced through this project included resonance Raman and related techniques, sum frequency generation, and X-ray standing wave spectroscopy. Center members relied extensively on computational tools such as density functional theory and microkinetic modeling to fully investigate catalyst structures and catalytic mechanisms. ICEP researchers were early developers of atomic layer deposition (ALD) for catalyst synthesis and were early pioneers of metal organic frameworks for catalysis. ICEP innovations are found in areas of intense research such as single-atom catalysts, catalytic deconstruction of plastics, and catalytic MOFs, to name a few. Research areas initiated by ICEP indirectly led to DOE EFRCs, startup companies, and other achievements. Over its 18 years of existence, ICEP involved two different PIs (Stair and Notestein) and 24 senior investigators across several academic disciplines at Northwestern University. There were tight collaborations with Argonne National Laboratory, including specialized equipment and experiments permanently located there. The center supported ~400 person-years of effort by graduate students and postdocs, either directly through DOE support or indirectly by leveraging independent support provided to the trainees, e.g. through the NSF GRFP or internal fellowships. The project resulted in 328 manuscripts and numerous conference presentations.

36 MATERIALS SCIENCE↗

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗