Search NASA⌕ Search

SEARCH · Search NASA

Results for “Uniformity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cloud Uniformity Measurement from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)

This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.

Ice-Crystal Icing↗

Cloud Uniformity Measurements from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)

This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.

Ice-Crystal Icing↗

Uniform Dust Deposition System for Dust Tolerance Studies

Future missions to the Moon will require mechanisms and materials to effectively and reliably operate in the presences of lunar regolith. One of the challenges of developing such technologies is terrestrial testing with lunar dust simulants. Dust has a stochastic nature of depositing and it can be difficult to accurately apply it to surfaces of interest. Deposition density, particles size distribution, and percent coverage are all factors that affect the quality of dust mitigation testing. Therefore, to enable such testing the dust mitigation and seals teams at NASA Glenn Research Center (GRC) have developed a system that can uniformly and repeatably deposit lunar simulants on a range of surfaces. Testing of the Dust Deposition System (DDS) and an associatedsimulant preparation methodology have quantified the levels of uniformity and precision for this system. Furthermore, the deposition system has been paired with automated micrograph capturing and machine learning image analysis to correlate the images of dust on a surface to deposition density (in g/cm2). This correlation alleviates the need for tested samples to be accurately weighed with milligram precision and may be a useful tool for in-situ contamination evaluation on the Moon. This paper covers the design and validation testing for the DDS.

Stephen Gerdts↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S. McCabe↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S McCabe↗

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc in conjunction with NASA GSFC and Genesis Engineering Solutions inc. has developed an innovative, fully T-VAC compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This source leverages a new shaped integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. This new illuminator also leverages a set of selectable LED arrays as well as broadband tungsten-halogen sources to provide multi-level, wide spectrum reference illumination to the VIIRS instrument over all optical sensor bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing for T-VAC campaigns. This technology is both flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.

Jeff Holt↗

A Uniform Analysis of Debris Discs with the Gemini Planet Imager II: Constraints on Dust Density Distribution Using Empirically Informed Scattering Phase Functions

Spatially resolved images of debris discs are necessary to determine disc morphological properties and the scattering phase function (SPF) thatantifies the brightness of scattered light as a function of phase angle. Current high-contrast imaging instruments have successfully resolved several dozens of debris discs around other stars, but few studies have investigated trends in the scattered-light, resolved population of debris discs in a uniform and consistent manner. We have combined Karhunen-Loeve Image Projection (KLIP) with radiative-transfer disc forward modelling in order to obtain the highest-quality image reductions and constrain disc morphological properties of eight debris discs imaged by the Gemini Planet Imager at H -band with a consistent and uniformly applied approach. In describing the scattering properties of our models, we assume a common SPF informed from solar system dust scattering measurements and apply it to all systems. We identify a diverse range of dust density properties among the sample, including critical radius, radial width, and vertical width. We also identify radially narrow and vertically extended discs that may have resulted from substellar companion perturbations, along with a tentative positive trend in disc eccentricity with relative disc width. We also find that using a common SPF can achieve reasonable model fits for discs that are axisymmetric and asymmetric when fitting models to each side of the disc independently, suggesting that scattering behaviour from debris discs may be similar to Solar system dust.

scattering↗

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc. in conjunction with NASA GSFC and Genesis Engineering Solutions Inc., has developed an innovative, vacuum compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This device features a uniquely shaped diffuse integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. A new liquid-cooled hybrid quartz-tungsten (QT) and light emitting diode (LED) source module has been engineered to provide direct-in-vacuum reference illumination over the full dynamic range and spectrum of the VIIRS instrument’s optical bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing in thermal vacuum (TVAC) campaigns. This technology is flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.

Jeffrey Holt↗

Uniformly Ordered Binary Decision Algorithm for Benchmark Experiment Correlations in Whisper Validation

When performing a validation exercise for determining the upper subcritical limit of a nuclear criticality safety application, an analyst should select and perform a statistical analysis on a population of benchmark experiments that are neutronically similar to the application. The size of this population should be sufficiently large such that the statistical analysis has a high degree of confidence that the bias plus bias uncertainty (calculational margin) has been accurately quantified. A complication arises because many benchmark experiments share common components, leading to correlations in their measured effective multiplication factors. Correlations between benchmark experiments within the population reduces its predictive power. This motivates the need for methods that consider benchmark experiment correlations and ensure adequate statistical significance of results. The Whisper code is a statistical analysis pack- age that incorporates nuclear data sensitivity coefficients from MCNP to assess benchmark experiment similarity and then performs an extreme-value analysis to estimate the bias plus bias uncertainty. The original methodology in Whisper does not consider the effect of benchmark experiment correlations when making this estimation, and this summary proposes the uniformly ordered binary decision algorithm to address this shortcoming. The original methodology in Whisper computes similarity coefficients ck for an application compared to all benchmark experiments in its library and develops weighting factors for a selected population proportional to the ck values. The methodology can be interpreted as statistically emulating a validation exercise for a particular application where the weighting factors may be viewed as the likelihood that an analyst would include a particular benchmark experiment within the population. The effective sample size of the population is the expected or mean number of benchmark experiments in the population. The uniformly ordered binary decision algorithm identifies clusters of correlated benchmark experiments within the population and then computes adjusted weighting factors based on the magnitude of the correlation coefficients within the cluster to compute a reduced effective sample size accounting for the lower information content because of correlations. Benchmark experiments within the cluster are ordered randomly with equal probability and probabilistic decisions are made as to whether a benchmark. experiment within the cluster should treated as redundant with a previous one; if two redundant benchmark experiments are included, then the conservative worst case bias plus bias uncertainty is used and the pair is counted as a single benchmark experiment in the population. Results are provided for HEU solutions in a research version of the Whisper software using benchmark experiment correlations provided by DICE, the Database for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). These show that there can be a significant increase in the bias plus bias uncertainty because the effective sample size is reduced, and therefore the algorithm, needing to meet sample size requirements, expands the benchmark experiment population by accepting less similar benchmark experiments that would have otherwise not been included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carboxyl-functionalized perovskite enables ALD growth of a compact and uniform ion migration barrier

Mixed-halide wide-band-gap perovskites are critical components of highly efficient tandem cells, but their operating stability is limited by halide migration. Metal oxides deposited via atomic layer deposition (ALD) have been shown to block halide migration; however, previously pursued methods result in inhomogeneous nucleation and growth. We hypothesized that functionalizing the perovskite surface with ALD-active carboxyl groups could promote nucleation and enable higher-temperature metal oxide growth. We find that 5-ammonium valeric acid iodide (5-AVAI) facilitates the formation of a compact and uniform aluminum oxide (Al 2 O 3 ) layer and allows growth at 100°C compared with the previous limit of 75°C. We demonstrate that halide migration into the C 60 electron transport layer is reduced by a factor of 10 compared with the reference case. Finally, Al 2 O 3 -capped perovskite solar cells with a band gap of 1.78 eV retain 90% of their initial power conversion efficiency after 1,000 h of continuous operation under 1-sun illumination at 55°C.

Al2O3↗

Thickness and uniformity mapping of thin foils using resistive silicon detectors

Alpha energy loss is a common tool used for measuring target thicknesses. However, these measurements are often made without position information, which either forfeits knowledge of material uniformity and local thickness or requires a prohibitive number of measurements per target to partially recover this information. In consideration of this, a method for measuring position-dependent thicknesses is described in this work; by using the position-sensitivity of the dual-axis duo-lateral (DADL) silicon detector, thicknesses across the entire face of the material can be measured to sub-mm precision with a single measurement. Several examples are presented using a number of targets with varying characteristics, which altogether demonstrate the precision, accuracy, and versatility of this technique.

Foil uniformity↗

Synthesis and Self-Assembly of Monodisperse Graphene Nanoribbons: Access to Submicron Architectures with Long-Range Order and Uniform Orientation

Fabricating organic semiconducting materials into large-scale well-organized architectures is critical for building high performance molecular electronics. While graphene nanoribbons (GNRs) hold enormous promise for various device applications, their assembly into a well-structured monolayer or multilayer architecture poses a substantial challenge. Here we report the preparation of length-defined monodisperse GNRs via the integrated iterative binomial synthesis (IIBS) strategy and their self-assembly into submicron-architectures with long-range order, uniform orientation as well as regular layers. Further, the use of short alkyl side chains benefits forming stable multi-layers through interlocking structures. By changing the length and backbone shapes of these monodisperse GNRs, various three-dimensional assemblies including multilayer stripes, monolayer stripes, and nanowires, can be achieved, leading to different photophysical properties and band gaps. The discovery of these intriguing self-assembly behaviors of length-defined GNRs is expected to open the door for various future applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of discharge polarity on streamer breakdown criterion of ambient air in a non-uniform electric field

Streamer breakdown of atmospheric air with non-uniform dc electric field in a needle-to-plate electrode configuration is studied using a semi-analytic model and experimental measurements. A high voltage (either positive or negative) is applied to a hollow needle with 0.51 mm outer diameter and 0.25 mm inner diameter separated from a planar ground electrode by a gap distance of 0.1–1.4 cm. Breakdown voltages are recorded for both positive and negative discharge polarities. Empirical relations between the critical avalanche size for streamer breakdown and the gap distance are proposed. Using these empirical relations, a semi-analytic model based on Meek's criterion for streamer breakdown is developed to accurately predict the measured breakdown voltages. It is found that for pd > 380 Torr cm (or d > 0.5 cm at one atmosphere) streamer breakdown of ambient air occurs at a lower applied voltage for a positively biased needle compared to that with a negatively biased needle, referred as the polarity effect. For pd < 380 Torr cm breakdown is attained at a lower applied voltage with a negatively biased needle compared to that with a positively biased needle, and breakdown mode transits from the polarity effect to the so called inverted polarity effect.

42 ENGINEERING↗

Chapter 17: Residential Behavior Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures, September 2011 - August 2020

This document has been updated in August 2020. This document was developed for the U.S. Department of Energy Uniform Methods Project (UMP). The UMP provides model protocols for determining energy and demand savings that result from specific energy-efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The protocols are updated on an as-needed basis. The UMP protocols can be used by utilities, program administrators, public utility commissions,evaluators, and other stakeholders for both program planning and evaluation. To learn more about the UMP, visit the website, https://energy.gov/eere/about-us/ump-home, or download the UMP introduction document at http://www.nrel.gov/docs/fy17osti/68557.pdf.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uniform Methods Project: History and Updates [Slides]

This presentation provides an overview of the 2026 update effort and summarizes the drivers and history of the Uniform Methods Project (UMP). The presentation will be used in a public webinar to facilitate stakeholder participation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗