Search NASA⌕ Search

SEARCH · Search NASA

Results for “Utility regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Transcriptome architecture of the three main lineages of agrobacteria

ABSTRACT Agrobacteria are a diverse, polyphyletic group of prokaryotes with multipartite genomes capable of transferring DNA into the genomes of host plants, making them an essential tool in plant biotechnology. Despite their utility in plant transformation, genome-wide transcriptional regulation is not well understood across the three main lineages of agrobacteria. Transcription start sites (TSSs) are a necessary component of gene expression and regulation. In this study, we used differential RNA-seq and a TSS identification algorithm optimized on manually annotated TSS, then validated with existing TSS to identify thousands of TSS with nucleotide resolution for representatives of each lineage. We extend upon the 356 TSSs previously reported in Agrobacterium fabrum C58 by identifying 1,916 TSSs. In addition, we completed genomes and phenotyping of Rhizobium rhizogenes C16/80 and Allorhizobium vitis T60/94, identifying 2,650 and 2,432 TSSs, respectively. Parameter optimization was crucial for an accurate, high-resolution view of genome and transcriptional dynamics, highlighting the importance of algorithm optimization in genome-wide TSS identification and genomics at large. The optimized algorithm reduced the number of TSSs identified internal and antisense to the coding sequence on average by 90.5% and 91.9%, respectively. Comparison of TSS conservation between orthologs of the three lineages revealed differences in cell cycle regulation of ctrA as well as divergence of transcriptional regulation of chemotaxis-related genes when grown in conditions that simulate the plant environment. These results provide a framework to elucidate the mechanistic basis and evolution of pathology across the three main lineages of agrobacteria. IMPORTANCE Transcription start sites (TSSs) are fundamental for understanding gene expression and regulation. Agrobacteria, a group of prokaryotes with the ability to transfer DNA into the genomes of host plants, are widely used in plant biotechnology. However, the genome-wide transcriptional regulation of agrobacteria is not well understood, especially in less-studied lineages. Differential RNA-seq and an optimized algorithm enabled identification of thousands of TSSs with nucleotide resolution for representatives of each lineage. The results of this study provide a framework for elucidating the mechanistic basis and evolution of pathology across the three main lineages of agrobacteria. The optimized algorithm also highlights the importance of parameter optimization in genome-wide TSS identification and genomics at large.

59 BASIC BIOLOGICAL SCIENCES↗

Elucidating Arsenic and Selenium Speciation in Coal Fly Ashes

Coal fly ash (CFA) is produced during the coal combustion process and contains trace elements (<100 ppm) including selenium (Se) and arsenic (As), both detrimental for environmental and human health. Existing management strategies for CFAs involve disposal in landfills and ash ponds, as well as beneficial usage in other applications such as in concrete. Both the direct disposal and beneficial usage of CFA raise concerns for environmental hazards due to the potential leaching of Se and As. CFAs were classified as reusable material by the U.S. Environmental Protection Agency (EPA) with the first federal regulation (Disposal of Coal Combustion Residuals from Electric Utilities, CCR) for its disposal established six years ago. During coal combustion process, parameters such as furnace firing type, emissions controls, coal rank, use of additives, and particulate matter controls, could contribute to significant variability in As/Se concentrations and their speciation. Although there have been a handful of studies on As/Se speciation on small sets of samples, they do not fully represent the current state of coal-fired electrical generating units. Little information exists on the detailed speciation (e.g. oxidation state, complexation state) of As/Se in large set of fly ash samples. To better investigate the role of the potential contributing parameters, a large-scale survey study with representative samples of typical coal source and combustion conditions is highly desired. The overall goal of this research is to systematically characterize As and Se speciation of representative coal fly ash samples using state-of-the-art synchrotron based spectroscopic and microscopic techniques, in order to develop a correlation between coal source/type, operation condition, As/Se speciation, and As/Se mobility. A detailed survey study was conducted documenting the current state-of-knowledge on fossil power generating units as a function of coal type/source, operating conditions, environmental control systems, additive use, and fly ash handling methods. Based on this survey, a matrix of fly ash samples representing a range of conditions were chosen and collected. The collected ash samples were analyzed for bulk characteristics such as elemental composition, microstructure, chemical and mineralogical composition, surface area, and particle size distribution. State-of-the-art synchrotron X-ray microscopy and spectroscopy techniques were applied to reveal the molecular scale speciation information of As and Se, such as oxidation state, association with other elements/minerals, and complexation states.

01 COAL, LIGNITE, AND PEAT↗

Overview of the Pathways to CO2 Utilization and Storage for the Intermountain West Region

The topic of the webinar focused on findings from the first phase of I-WEST initiative, specifically related to CO2 utilization and storage as one of the many potential deep decarbonization pathway available to the region. Specifically, the seminar presented topics like: an overview of CCUS technology and benefits; a highlight of a variety of CO2 storage and utilization approaches available to the region, relevant governing regulations, and technical and non-technical grand challenges associated with each option; findings from an assessment of opportunities for CCUS deployment at significant scale within the Intermountain West; and context to help listeners better understand the technical aspects of CCUS and how they interface with economic, social, and policy aspects of decarbonization applicable to the I-WEST geographic region.

Vikara, Derek↗

Local structure and ion storage properties of vanadate cathode materials regulated by the pre-alkalization

Aqueous Zn-ion batteries using mild acidic electrolytes utilizing a Zn 2+ /H + dual-ion storage mechanism have shown great potential in achieving high energy density comparable to non-aqueous lithium-ion batteries. Here, this study reveals that hydrated alkali-ions regulate the formation of alkali-intercalated vanadate layered compounds. Among various vanadate materials, lithium-intercalated vanadate has the largest interlayer spacing and most disordered local structure, exhibiting the largest storage capacity of 308 mA h g –1 at 0.05 A g –1 for Zn 2+ /H + dual-ion storage and improved charge transfer and transport kinetics and cycling performance, evidenced by in situ X-ray diffraction and ex situ X-ray total scattering and pair distribution function analysis. Our study provides new insight into designing layered vanadate materials for high-capacity aqueous batteries.

25 ENERGY STORAGE↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services

This paper develops a hierarchical control frame-work to aggregate and to manage behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. In the proposed framework, firstly, each controller in the hierarchy determines the flexibility of the DERs such that the obtained flexibility is feasible with respect to its operational purview. For example, the operational purview of a home energy management system may only consider consumer comfort preferences, while that for an aggregator or a grid controller may consider network voltage management as well. Based on the feasible flexibility, optimal setpoints for the DERs is then determined by the hierarchical controllers to help the distribution power network in voltage regulation, coordination issues with existing transmission-level conventional generators, etc. Therefore, the proposed strategy, which is based on model-predictive control, can be effectively utilized by the distribution network to coordinate several DERs to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

behind-the-meter↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services

This paper develops a hierarchical control frame-work to aggregate and to manage behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. In the proposed framework, firstly, each controller in the hierarchy determines the flexibility of the DERs such that the obtained flexibility is feasible with respect to its operational purview. For example, the operational purview of a home energy management system may only consider consumer comfort preferences, while that for an aggregator or a grid controller may consider network voltage management as well. Based on the feasible flexibility, optimal setpoints for the DERs is then determined by the hierarchical controllers to help the distribution power network in voltage regulation, coordination issues with existing transmission-level conventional generators, etc. Therefore, the proposed strategy, which is based on model-predictive control, can be effectively utilized by the distribution network to coordinate several DERs to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiplex knockout of trichome-regulating MYB duplicates in hybrid poplar using a single gRNA

As the focus for CRISPR/Cas-edited plants moves from proof-of-concept to real-world applications, precise gene manipulation will increasingly require concurrent multiplex editing for polygenic traits. A common approach for editing across multiple sites is to design one guide RNA (gRNA) per target; however, this complicates construct assembly and increases the possibility of off-target mutations. In this study, we utilized one gRNA to target MYB186, a known positive trichome regulator, as well as its paralogs MYB138 and MYB38 at a consensus site for mutagenesis in hybrid poplar (Populus tremula × P. alba INRA 717-1B4). Unexpected duplications of MYB186 and MYB138 resulted in eight alleles for the three targeted genes in the hybrid poplar. Deep sequencing and polymerase chain reaction analyses confirmed editing across all eight targets in nearly all of the resultant glabrous mutants, ranging from small indels to large genomic dropouts, with no off-target activity detected at four potential sites. This highlights the effectiveness of a single gRNA targeting conserved exonic regions for multiplex editing. Additionally, cuticular wax and whole-leaf analyses showed a complete absence of triterpenes in the trichomeless mutants, hinting at a previously undescribed role for the nonglandular trichomes of poplar.

59 BASIC BIOLOGICAL SCIENCES↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-temperature and high-rate-charging lithium metal batteries enabled by an electrochemically active monolayer-regulated interface

Stable operation of rechargeable lithium (Li)-based batteries at low temperatures is vital for cold-climate applications but is plagued with dendritic Li plating and unstable solid-electrolyte interphase (SEI). Here we report high-performance Li-metal batteries under low-temperature and high-rate-charging conditions. This is realized by utilizing a self-assembled monolayer of electrochemically active molecules on current collectors that regulates the nanostructure and composition of SEI and deposition morphology of Li metal anodes. A multilayer SEI containing a LiF-rich inner phase and amorphous outer layer effectively seals the Li surface in contrast to the conventional impassive SEI at low temperatures. As a result, galvanic Li corrosion and self-discharge were suppressed; stable Li deposition was realized from -60º to 45ºC; and a Li|LiCoO 2 cell with a capacity of 2.0 mAh cm -2 displayed a 200-cycle life at -15ºC with a recharge time of 45 minutes.

25 ENERGY STORAGE↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Developing Renewable Energy Applications for Water Treatment Technologies and Transmission

The need for smaller treatment facilities for more isolated or rural municipal entities and industrial water treatment facilities continues to grow. From environmental justice and energy needs in remote communities that have never been serviced by larger scale utilities to smaller onsite treatment requirements to meet discharge regulations, energy efficient treatment systems that can leverage renewable energy sources can be an important asset to owners. Climate change and population dynamics have changed the needs for distributed water treatment systems and the manner in which they function. New treatment technologies that can operate under dynamic conditions and leverage variable energy sources (e.g., renewable energy, RE) can provide substantial efficiencies and cost savings. The National Renewable Energy Laboratory (NREL) is embarking on research projects that will perform multi-scale studies to investigate treatment technologies on varying source water quality that can operate under unsteady state flow conditions (timing) in response to energy availability, supply, and demand. A pilot-scale system will be built to assess modularity and scaling of treatment system operating conditions and performance. Modeling will also be used to determine feasibility and integration into grid emulation platforms to understand the use and value of operation with RE. Optimization will be completed for the treatment and distribution systems to document strengths and weaknesses of using RE power sources. Results of this effort will advance dynamic water treatment understanding under variable conditions and integration of RE sources to power these systems. This will lead to further decarbonization of municipal and private treatment facilities while supporting a paradigm shift in water treatment process operation and system design to achieve net-zero goals and move toward energy-sensitive resilient water treatment systems.

ENERGY PLANNING, POLICY, AND ECONOMY↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

Evaluation of the Performance and Exhaust Emissions of a 4 Cylinder CI Engine Operating With Dimethyl Ether (DME) and Propane Blends

In response to stringent emissions regulations and the need for higher efficiency engines, the utilization of DME and propane fuel blends in compression ignition (CI) engines has gained interest in the automotive industry. In this study, a range of DME-propane blends are explored in a CI combustion strategy at high injection pressures. A GT-Power model of a 2.2 L Hyundai CI engine was developed to facilitate evaluation of the impacts of variations of DME and propane blends at a light and medium engine speed-torque-load operating condition; specifically at 1500 rpm, 50 Nm and 2.84 bar brake mean effective pressure (BMEP); and 2000 rpm, 150 Nm, 8.53 bar BMEP speed-torque-load combination. Here, the GT-Power model was validated using Computational Fluid Dynamics (CFD) simulations. The results indicate that high diesel-like efficiencies can be achieved with a 100% DME mass substitution and up to 50% propane-DME blends could be implemented without a significant penalty on engine performance indicators. Significant brake specific nitrogen oxides (BSNOx) reductions were also observed along with reductions in carbon dioxide (CO2) and soot when leveraging these fuel blends.

computational fluid dynamics↗

Harnessing Heterologous Bacterial Two-Component Systems as Biosensors to Address Challenges in Fermentation Scale-Up

Scaling up bacterial fermentation from bench to industrial scale often results in unpredictable performance losses, possibly in part due to changes in microenvironmental conditions such as pH. To investigate this, we developed a suite of pH-sensitive biosensors from bacterial two-component systems (TCSs) that provide a dynamic, fluorescent readout in response to extracellular pH changes. TCSs consist of a periplasmic sensor histidine kinase (HK) that, in response to an extracellular stimulus, autophosphorylates intracellularly and subsequently transfers the phosphate to a cognate response regulator (RR) that modulates transcription of target genes. We utilized three pH-responsive TCSs (referred to here as CVJ1, CVJ30, and CVJ79) and linked their output to GFP. This was achieved by placing the RR promoter upstream of GFP or by constructing a chimeric RR composed of the native receiver domain and the DNA-binding domain of another well-characterized RR with a defined promoter. All components - HK, RR (native or chimeric), and GFP under its corresponding promoter - were cloned into a broad-host-range plasmid. Sensors were validated in Escherichia coli and Pseudomonas putida, including the muconic acid-producing strain P. putida TL207. All three biosensors successfully reported pH, with fluorescence (normalized to optical density) correlating strongly with media pH. Among the native sensors, CVJ79 showed the most robust performance while CVJ1 also performed best in its native form; CVJ30 exhibited improved functionality as a chimera, suggesting that modular RR design can enhance compatibility in some heterologous hosts. Further, CVJ79 was activated by alkaline conditions, while CVJ30 responded to acidic environments. Notably, CVJ1 was induced by high pH in wild-type E. coli and P. putida, but low pH in TL207. The observed differences in sensor activation between strains - particularly the divergent response of CVJ1 - suggest that host-specific regulatory pathways may influence how cells perceive and adapt to pH stress. Moving forward, these biosensors can be used to guide the rational design of more robust strains, optimize process conditions in real time, and inform strategies to minimize physiological heterogeneity during scale-up. Integrating these tools into high-throughput screening and bioreactors will be a key step toward improving predictability and performance in industrial bioprocesses.

09 BIOMASS FUELS↗

Final Technical Report for DE-SC0022206

This project developed foundational genetic, genomic, and epigenetic tools for anaerobic fungi (Neocallimastigomycota), a group of microorganisms with exceptional natural abilities to deconstruct lignocellulosic biomass. Efficient biomass deconstruction remains a major barrier to economical production of renewable fuels, chemicals, and materials from agricultural and forestry residues. The project sought to enable mechanistic studies and future engineering of anaerobic fungi by improving genomic resources, establishing methods for gene expression, and investigating epigenetic regulation of biomass-degrading pathways. Major accomplishments included generation of the first chromosome-scale genome assemblies for multiple anaerobic fungal species, providing publicly available genomic resources that support both engineering and fundamental biological research. The project established the first reproducible system for heterologous gene expression in anaerobic fungi and identified genomic features and mobile genetic elements that may support future development of stable transformation technologies. In parallel, the project demonstrated direct conversion of untreated lignocellulosic biomass into fuels and specialty chemicals through a fungal-yeast bioprocess and identified anaerobic fungal enzymes with utility for metabolic engineering. The research also revealed that epigenetic regulation plays an important role in controlling fungal gene expression and enzyme production, identifying potential strategies for enhancing biomass degradation. Collectively, this work established anaerobic fungi as a tractable emerging platform for bioenergy and biomanufacturing research, generated valuable public resources, trained the next generation of researchers, and advanced DOE-BER goals related to predictive biology, sustainable bioprocessing, and the circular bioeconomy.

Solomon, Kevin [University of Delaware] (ORCID:000↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Panel discussion: Challenges and improvements in accident dose analysis; Regulatory and industry perspective

Full text of publication follows. Design basis accident (DBA) analyses are one of several ways nuclear power plant licensees demonstrate, and the U.S. Nuclear Regulatory Commission (NRC) staff verifies, that the design and location of a nuclear power plant are appropriate and that the protection of health and safety of the public is maintained. In July 2000, the NRC staff issued Regulatory Guide 1.183, 'Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors' (RG 1.183) [1]. RG 1.183 provides a method acceptable to the NRC staff for complying with the regulatory requirements contained in Title 10 of the Code of Federal Regulation (10 CFR) Section 50.67 (50.67), 'Accident source term' [2]. RG 1.183 also provides assumptions and parameters used to model postulated DBA radiological analyses for light-water reactors (LWR). Since the initial issuance of RG 1.183, the NRC staff and the nuclear power plant licensees have both gained substantial experience with the implementation of 10 CFR 50.67 and RG 1.183. Based on this experience, comments from licensees, the anticipation of licensing advanced LWRs, and new research, the NRC is developing a proposed revision to RG 1.183. This panel discussion will provide a discussion of that proposed revision, its potential impact on existing and future evaluations, and the industry perspective on the revised guidance. References: 1) USNRC, Regulatory Guide 1.183, 'Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors,' Revision 0, U.S. Nuclear Regulatory Commission, Washington, D.C. (2000), Electronic copies are also available in ADAMS (http://www.nrc.gov/reading-rm/adams.html), under Accession No. ML003716792. 2) U.S. Code of Federal Regulations, Title 10 (Energy), Part 50 (Domestic Licensing of Production and Utilization Facilities), Section 67, (Accident source term), Office of the Federal Register, Washington, DC (1999). (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗