Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vacuum Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Growth of Well-Defined Model Catalysts for Electrochemistry: From Surface Science Studies to Electrocatalytic CO2 Conversion

We combined ultrahigh vacuum (UHV) surface science techniques, electrochemical measurements, and computational modeling to investigate electrocatalytic systems that are crucial components of the carbon management effort, including oxygen evolution reactions (OER) and CO2 reduction reactions (CO2RR). Well-defined Model catalysts were grown on substrates in the UHV chamber and characterized with X-ray photoelectron spectroscopy (XPS) and scanning tunneling microscopy (STM). Selected model electrocatalysts were then tested in electrochemical cells to establish the structure-property relationships in OER and CO2RR. Our results showed that the edge sites of Fe2O3 grown on Au(111) were the most active toward OER and incorporation of Ni at the edge sites (NiFeOx) further boosted their OER activity. We also resolved the size-dependent electrocatalytic CO2-to-CO conversion of the Ag nanoparticle electrocatalysts with average particle diameter between 2 to 6 nm: smaller diameter (< 3 nm) particles favored H2 evolution reaction (HER) due to a high population of Ag edge sites, whereas larger diameter particles favored CO2RR as the population of Ag(100) surface sites grew. We further discovered that electronic interactions between small diameter Ag particles and highly defective carbon supports could break the size-dependent CO2RR selectivity, resulting in highly selective (CO Faradaic Efficiency > 90%) and active Ag nanoparticle electrocatalysts with sizes < 2 nm diameter.

Deng, Xingyi↗

Ion Manipulation from Liquid Xe to Vacuum: Ba-Tagging for a nEXO Upgrade and Future 0 νββ Experiments

Neutrinoless double beta decay (0𝜈𝛽𝛽) provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for 0𝜈𝛽𝛽 decay in 136 Xe with a projected half-life sensitivity exceeding 10 28 years at the 90% confidence level using a liquid xenon (LXe) Time Projection Chamber (TPC) filled with 5 tonnes of Xe enriched to ∼90% in the 𝛽𝛽-decaying isotope 136 Xe. In parallel, a potential future upgrade to nEXO is being investigated with the aim to further suppress radioactive backgrounds and to confirm 𝛽𝛽-decay events. This technique, known as Ba-tagging, comprises extracting and identifying the 𝛽𝛽-decay daughter 136 Ba ion. One tagging approach being pursued involves extracting a small volume of LXe in the vicinity of a potential 𝛽𝛽-decay using a capillary tube and facilitating a liquid-to-gas phase transition by heating the capillary exit. The Ba ion is then separated from the accompanying Xe gas using a radio-frequency (RF) carpet and RF funnel, conclusively identifying the ion as 136 Ba via laser-fluorescence spectroscopy and mass spectrometry. Simultaneously, an accelerator-driven Ba ion source is being developed to validate and optimize this technique. The motivation for the project, the development of the different aspects, along with the current status and results, are discussed here.

a-tagging↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Understanding of Ag Nanocatalysts for Electrocatalytic CO2 Conversion: Effects of Particle Size and Carbon Support

In this talk, we combined ultrahigh vacuum (UHV) surface science techniques, electrochemical measurements, and computational modeling to investigate Ag based electrocatalysts for CO2 reduction reaction (CO2RR). Our goal is to understand the critical characteristics governing the activity and selectivity of Ag electrocatalysts. Ag electrocatalysts were grown on highly oriented pyrolytic graphite (HOPG) in the UHV chamber, characterized with X-ray photoelectron spectroscopy (XPS) and scanning tunneling microscopy (STM), and then tested in a custom-built gastight H-cell. Supported by computational modeling based on density functional theory (DFT) calculations and microkinetic modeling (MKM), our studies revealed a strong size-dependent electrocatalytic CO2-to-CO conversion of the Ag nanoparticle electrocatalysts with average particle diameter between 2 to 6 nm. Smaller diameter (< 3 nm) particles favored H2 evolution reaction (HER) due to a high population of Ag edge sites, whereas larger diameter particles favored CO2RR as the population of Ag(100) surface sites grew. We further discovered that electronic interactions between small diameter Ag particles and highly defective carbon supports could break the size-dependent CO2RR reactivity, resulting in highly selective (CO Faradaic Efficiency > 90%) and active Ag nanoparticle electrocatalysts with sizes < 2 nm diameter. This knowledge is key to understand electrocatalysts performance and to ultimately guide electrocatalyst design

Ag nanoparticles↗

Toward the implementation of self-powered, wireless, real-time reactor power sensing

The successful development of real-time, self-powered, wireless reactor power sensing technology would enable key operating parameters of every fuel assembly in a commercial reactor core to be continuously monitored, and potentially be utilized for applications such as closed-loop reactor control. This paper discusses the expansion of successful work on the application of Self Powered Neutron Detectors (SPND) for reactor power monitoring and the wireless transmission of these detector signals using advanced vacuum micro-electronic (VME) transmitter technology developed by Westinghouse in collaboration with the Penn State University Radiation Science and Engineering Center. Results demonstrate that this technology may be successfully applied via long-term testing in the Penn State TRIGA reactor. SPND are inherently slower than, for example, ion chambers due to their dependence on radioactive decay to generate a signal. Additional research developed delay compensation algorithms to accelerate the response of these detectors for use in near-real-time closed-loop reactor control. Initial results indicate that practical signal acceleration can be obtained digitally or with an equivalent analog circuit. Future research will apply an inverse model of the sensor’s balance differential equations to more-effectively accelerate the SPND signal. Use of inverse models will also prove to be adaptive in the sense that time-dependent burn-up of these detectors, due to neutron activation of the detector material, can be modeled and applied in the acceleration algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing and Processing of Pre-production 325 MHz Single Spoke Resonator Power Couplers for PIP-II Project

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

43 PARTICLE ACCELERATORS↗

PDRD Project 19039 - All metal vacuum scroll pump development for tritium

Currently the United States relies on a single source, foreign company, Eumeca (formerly Normetex) for the supply of an all metal vacuum scroll pump to process tritium. This “one of a kind”, all metal, vacuum scroll pump utilizes no “wetted”, polymeric materials that degrade prematurely when exposed to tritium. U.S. based vacuum scroll pump suppliers typically utilize a polymer, Teflon®, as a tip seal material at the edge of the scroll impellers for proper pump function. Teflon® is known to degrade within a relatively short time frame (approximately 1 year) when continually exposed to tritium gas. This degradation results in “flaking” of the Teflon® material which results in particulate contamination of the process gas stream. While filtration of the particulate is possible, doing so requires additional maintenance which is costly in a glovebox environment. In addition, filtration can degrade pumping system performance as particulate collects in the filter media over time. To date, all of the well established U.S and European based vacuum scroll pump manufacturers have been uninterested in developing an all metal vacuum scroll pump that does not use a polymeric scroll tip seal. This position is taken as the vacuum scroll pump manufacturers do not see a large enough market to make it profitable for them to develop and market an all metal vacuum scroll pump. In the mid 2000s, one company, Air Squared, Inc., a small Original Equipment Manufacturer (OEM) specializing in design and fabrication of custom scroll vacuum pumps and compressors, was willing to pursue the effort. The first design effort incorporated Vespel® as a polymeric tip seal material. Results of this effort led to realizing the affect that the Met-Bel MB-601 metal bellows pump has on performance when used as a backing pump for an all metal vacuum scroll pump without a scroll tip seal. As a result, Air Squared subsequently designed an all metal vacuum scroll pump without a tip seal material for evaluation. Although the initial, all metal version of the Air Squared pump was found deficient in regard to scroll impeller stiffness, which resulted in scroll contact, general design and pump performance was verified to be adequate. SRS PDRD Project 19039 was launched in 2019 as a 3rd attempt with Air Squared, Inc. in regard to development of an all metal vacuum scroll pump for consideration as an equivalent to the Eumeca/ Normetex pump. The effort specified 300 series stainless steel for the scroll impellers, all metal sealing, and design to meet tritium throughput and ultimate vacuum requirements. In addition, a 60 psig design pressure rating requirement was specified for the pump containment boundary. The 3rd generation Air Squared pump has been designed, fabricated, and has received preliminary testing. Preliminary testing has indicated proper leak tightness and pump performance. However, work continues regarding development of a pumping chamber containment bellows that can be subjected to 66 psig without damage to the bellows. Work will continue in 2020 and 2021 to pursue a pumping chamber containment bellows that meets the pressure rating requirement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TESTING AND PROCESSING OF PRE-PRODUCTION 325 MHZ SINGLE SPOKE RESONATOR POWER COUPLERS FOR PIP-II PROJECT

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project [1]. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance study of charcoal-based radon reduction systems for ultraclean rare event detectors

The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. 222 Rn produces a particularly problematic background in the physics region of interest by the "naked" beta decay of its 214 Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current ton-scale detectors at slow flow rates (0.5-2 SLPM), radon reduction in the entire circulation loop at high flow rates $\mathcal{O}$(100s SLPM) is necessary to reach high sensitivity in future generation experiments. In this article we explore radon dynamics with a charcoal-based radon reduction system in the main circulation loop of time projection chamber detectors. Here, we find that even for perfect radon traps, circulation speeds of 2,000 SLPM are needed to reduce radon concentration in a 10 ton detector by 90%. This is faster by a factor of four than the highest circulation speeds currently achieved in dark matter detectors. We further find that the effectiveness of vacuum swing adsorption systems, which have been employed very successfully at reducing atmospheric radon levels in clean-rooms, is limited by the intrinsic radon activity of the charcoal adsorbent in ultra-low radon environments. Adsorbents with significantly lower intrinsic radon activity than in currently available activated charcoals would be necessary to build effective vacuum swing adsorption systems operated at room temperature for rare event search experiments. If such VSA systems are cooled to about 190 K, this requirement relaxes drastically.

47 OTHER INSTRUMENTATION↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative Measurement of Positive and Negative Ion Species Ejected from a Li–O–H Surface by Hydrogen and Noble Gas Ion Irradiation

We report sputtering yields of Li + , H - , O - , and OH x - ion species from an Li–O–H surface for H, D, He, Ne, and Ar ion irradiation at 45° incidence in the energy range of 30–2000 eV. A Li film was deposited on a stainless steel target using Li evaporators in the LTX-β vessel, using the LTX-β Sample Exposure Probe (SEP), which includes an ultrahigh vacuum suitcase for transferring targets without significant contamination from air exposure. The SEP was used to transfer the Li-coated target from LTX-β to a separate Sample Exposure Station (SES) to perform ion exposure measurements. The SEP was also used for characterization of the Li-coated target utilizing X-ray photoelectron spectroscopy in a different chamber, showing that the lithium film surface was oxidized. Ion exposures were performed using an electron cyclotron resonance plasma source in the SES. Sputtered/ejected species were sampled by a quadrupole mass spectrometer with capabilities for detecting positive and negative ions, and an energy filter for determining the mean kinetic energy of the ejected ion species. All ion irradiations caused Li + ions to be ejected, while causing impurity ions such as H + , H - , O - and OH - to be ejected. Measured ion energies of Li + ions from a Li–O–H surface suggested that the typical sheath potential on the divertor surface can trap sputtered Li + ions, which were previously reported as ~ 60% of total sputtered Li species from Li targets (Allain and Ruzic in Nucl Fusion 42:202, 2002). Hence, our results for the sputtering yields of ejected ion species and their associated ion energies from a Li–O–H surface indicates that lithium sputtering is suppressed and impurity removal is enhanced due to the sheath potential at the divertor surface for fusion reactor applications.

Plasma-material interaction↗

Comparison of δ 13 C analyses of individual foraminifer ( Orbulina universa ) shells by secondary ion mass spectrometry and gas source mass spectrometry

Rationale: The use of secondary ion mass spectrometry (SIMS) to perform micrometer-scale in situ carbon isotope (δ 13 C) analyses of shells of marine microfossils called planktic foraminifers holds promise to explore calcification and ecological processes. The potential of this technique, however, cannot be realized without comparison to traditional whole-shell δ 13 C values measured by gas source mass spectrometry (GSMS). Methods: Paired SIMS and GSMS δ 13 C values measured from final chamber fragments of the same shell of the planktic foraminifer Orbulina universa are compared. The SIMS–GSMS δ 13 C differences (Δ 13 C SIMS-GSMS ) were determined via paired analysis of hydrogen peroxide-cleaned fragments of modern cultured specimens and of fossil specimens from deep-sea sediments that were either untreated, sonicated, and cleaned with hydrogen peroxide or vacuum roasted. After treatment, fragments were analyzed by a CAMECA IMS 1280 SIMS instrument and either a ThermoScientific MAT-253 or a Fisons Optima isotope ratio mass spectrometer (GSMS). Results: Paired analyses of cleaned fragments of cultured specimens (n = 7) yield no SIMS–GSMS δ 13 C difference. However, paired analyses of untreated (n = 18) and cleaned (n = 12) fragments of fossil shells yield average Δ 13 C SIMS-GSMS values of 0.8‰ and 0.6‰ (±0.2‰, 2 SE), respectively, while vacuum roasting of fossil shell fragments (n = 11) removes the SIMS–GSMS δ 13 C difference. Conclusions: The noted Δ 13 C SIMS-GSMS values are most likely due to matrix effects causing sample–standard mismatch for SIMS analyses but may also be a combination of other factors such as SIMS measurement of chemically bound water. The volume of material analyzed via SIMS is ~10 5 times smaller than that analyzed by GSMS; hence, the extent to which these Δ 13 C SIMS-GSMS values represent differences in analyte or instrument factors remains unclear.

58 GEOSCIENCES↗

Engineering Scale Drying of Aluminum-Clad Spent Nuclear Fuel: Experiment Report

Engineering-scale tests were performed to evaluate the relative effectiveness of forced gas and vacuum-drying processes on aluminum-clad spent nuclear fuel (ASNF) in preparation for extended dry storage. Drying models were developed to improve confidence in the likely range of conditions at the start of dry storage and to understand the factors most significant to each process. Testing was performed at the Holtec International Forced Helium Dehydration training facility in Camden, New Jersey, by students from the University of South Carolina in collaboration with Idaho National Laboratory. A full-size Type 1a basket, with a full-diameter vessel configuration (based on the Department of Energy standardized canister design), was used in combination with a 10 assembly surrogate ASNF arrangement to provide a proxy for geometry. A resistance heater incorporated in one assembly simulated the influence of 100 W decay heat. This instrumented chamber allowed testing of the removal of bulk water, physisorbed water, and chemisorbed water over a range of operating parameters with either drying process. Thick oxide films were grown on aluminum test plates to mimic the ASNF surface chemistry. These one-use test plates were housed within select assemblies during drying. Post-test analysis of these plates gave a measure of the moisture removed during each test, which was compared to a control. Instrumentation provided detailed thermal, humidity, and gas or pressure data relevant to each test. Model simulations generally compared favorably to instrument data for the tests. While both processes were able to remove bulk water, removal of chemisorbed water was shown to depend heavily on local temperature. To the disadvantage of vacuum drying, operations approaching or exceeding 220°C achieved consistently more dehydroxylation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative Morphological Characterization of Carbide Inclusions in Uranium Metal

Uranium carbides (UCs) are prevalent inclusions in U metal that form during melting operations from interactions with crucible walls and the casting chamber atmosphere. Although UCs have been studied extensively since the beginning of U metal foundry operations, there are still unknowns regarding the effects of thermomechanical processing on their sizes and morphology. Here, we present the results of a series of controlled cooling experiments with molten uranium to elucidate the effect of cooling rate on inclusion morphology in a-U. Samples were melted using a vacuum induction melter and manually cooled at rates of 2.5, 1.7, 1.1, 0.8, 0.3 (± 1%) K/s from ~1600 K to <700 K in under 1 hour. Subsequent scanning electron microscopy (SEM) was performed on cross-sections of the samples, revealing a complex mixture of UC morphologies that are indicative of diffusion and growth influenced by the thermal processing of the U matrix. Image analysis using the Morphological Analysis of Materials (MAMA) software showed that UC sizes generally grew larger with slower cooling rates, and the two slowest cooling rates noticeably impacted the inclusion circularity and ellipse aspect ratio. These results indicate that UC morphology is sensitive to short cooling rates (<1 hour) and could therefore be controlled in the production of metallic nuclear fuels. Additionally, inclusion speciation and morphologies could potentially provide forensic clues about processing history of unknown metal samples. Understanding the driving forces involved in UC morphology evolution is beneficial for evaluating metal fuels for next generation nuclear reactors and for identifying signatures for nuclear forensics.

Athon, Matthew T.↗

Extending light WIMP searches to single scintillation photons in LUX

© 2020 American Physical Society. We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a twofold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c2 WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement report: The Fifth International Workshop on Ice Nucleation phase 1 (FIN-01): intercomparison of single-particle mass spectrometers

Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.

54 ENVIRONMENTAL SCIENCES↗

Quasi-steady testing approach for high-power Hall thrusters

Hall effect thrusters operating at power levels in excess of several hundreds of kilowatts have been identified as enabling technologies for applications such as lunar tugs, large satellite orbital transfer vehicles, and solar system exploration. These large thrusters introduce significant testing challenges due to the propellant flow rate exceeding the pumping speed available in most laboratories. Even with proposed upgrades in mind, the likelihood that multiple vacuum facilities will exist in the near future to allow long duration testing of high-power Hall thrusters operating at power levels in excess of 100 kW remains extremely low. In this article, we numerically explore the feasibility of testing Hall thrusters in a quasi-steady mode defined by pulsing the mass flow rate between a nominal and a low value. Here, our simulations indicate that sub-second durations available before the chamber reaches critical pressure are sufficiently long to achieve the steady-state current and flow field distributions, allowing us to characterize thruster performance and the near plume region.

42 ENGINEERING↗