Search NASA⌕ Search

SEARCH · Search NASA

Results for “WATER VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Water and vapor transport in algal‐fungal lichen: Modeling constrained by laboratory experiments, an application for Flavoparmelia caperata

ABSTRACT Algal‐fungal symbionts share water, nutrients, and gases via an architecture unique to lichens. Because lichen activity is controlled by moisture dynamics, understanding water transport is prerequisite to understand their fundamental biology. We propose a model of water distributions within foliose lichens governed by laws of fluid motion. Our model differentiates between water stored in symbionts, on extracellular surfaces, and in distinct morphological layers. We parameterize our model with hydraulic properties inverted from laboratory measurements of Flavoparmelia caperata and validate for wetting and drying. We ask: (1) Where is the bottleneck to water transport? (2) How do hydration and dehydration dynamics differ? and (3) What causes these differences? Resistance to vapor flow is concentrated at thallus surfaces and acts as the bottleneck for equilibrium, while internal resistances are small. The model captures hysteresis in hydration and desiccation, which are shown to be controlled by nonlinearities in hydraulic capacitance. Muting existing nonlinearities slowed drying and accelerated wetting, while exaggerating nonlinearities accelerated drying and slowed wetting. The hydraulic nonlinearity of F. caperata is considerable, which may reflect its preference for humid and stable environments. The model establishes the physical foundation for future investigations of transport of water, gas, and sugar between symbionts.

Potkay, Aaron↗

Oxidation and Reduction of Polycrystalline Cerium Oxide Thin Films in Hydrogen

This study investigates the oxidation state of ceria thin films' surface and subsurface under 100 mTorr hydrogen using ambient pressure X-ray photoelectron spectroscopy. We examine the influence of the initial oxidation state and sample temperature (25-450 °C) on the interaction with hydrogen. Our findings reveal that the oxidation state during hydrogen interaction involves a complex interplay between oxidizing hydride formation, reducing thermal reduction, and reducing formation of hydroxyls followed by water desorption. In all studied conditions, the subsurface exhibits a higher degree of oxidation compared to the surface, with a more subtle difference for the reduced sample. The reduced samples are significantly hydroxylated and covered with molecular water at 25 °C. We also investigate the impact of water vapor impurities in hydrogen. We find that although 1 × 10 -6 Torr water vapor oxidizes ceria, it is probably not the primary driver behind the oxidation of reduced ceria in the presence of hydrogen.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Safety Compliance Verification of Fuel Cell Electric Vehicle Exhaust

NREL has been developing compliance verification tools for allowable hydrogen levels prescribed by the Global Technical Regulation Number 13 (GTR-13) for hydrogen fuel cell electric vehicles (FCEVs). As per GTR-13, FCEV exhaust is to remain below 4 vol% H2 over a 3-second moving average and shall not at any time exceed 8 vol% H2 and that this requirement is to be verified with an analyzer that has a response time of less than 300 ms. To be enforceable, a means to verify regulatory requirements must exist. In response to this need, NREL developed a prototype analyzer that meets the GTR metrological requirements for FCEV exhaust analysis. The analyzer was tested on a commercial fuel cell electric vehicle (FCEV) under simulated driving conditions using a chassis dynamometer at the Emissions Research and Measurement Section of Environment and Climate Change Canada and FCEV exhaust was successfully profiled. Although the prototype FCEV Exhaust Analyzer met the metrological requirements of GTR-13, the stability of the hydrogen sensor was adversely impacted by condensed water in the sample gas. FCEV exhaust is at an elevated temperature and nearly saturated with water vapor. Furthermore, condensed water is present in the form of droplets. Condensed water in the sample gas can collect on the hydrogen sensing element, which would not only block access of hydrogen to the sensor but can also permanently damage the sensor. In the past year, the design of the gas sampling system was modified to mitigate against the transport of liquid water to the sensing element. Laboratory testing confirmed the effectiveness of the modified sampling system water removal strategy while maintaining the measurement range and response time required by GTR-13. Testing of the upgraded analyzer design on an FCEV operating on a chassis dynamometer is scheduled for the summer of 2021.

DIRECT ENERGY CONVERSION,HYDROGEN↗

Stereochemically‐Controlled Fluorinated Copolymers for Selectively Permeable Barrier Applications

Selective oxygen permeability coupled with low water vapor transmission is essential for biomedical and packaging applications requiring controlled oxygen flux under humid conditions. However, most high‐performance barrier polymers depend on perfluoroalkyl substances (PFAS), whose persistence and regulatory restrictions limit their long‐term applicability. We designed a series of stereocontrolled thiol‐yne‐based polyesters, including both fluorinated and non‐fluorinated variants, for selective oxygen permeability with considerable water barrier performance. Tailoring polymer crystallinity and morphology tuned both oxygen transport and mechanical properties. Fluorinated polymers demonstrated enhanced hydrophobicity and water resistance while maintaining oxygen diffusivity within a range relevant to oxygen‐sensing applications. Structure–property relationships were elucidated through small‐ and wide‐angle X‐ray scattering, revealing semi‐crystalline domains influenced by fluorine content and dithiol chain length. Barrier performance was rigorously evaluated via water vapor transmission rate and dynamic vapor sorption, showing reduced water uptake with increasing dithiol monomer length and crystallinity. In conclusion, this work introduces a PFAS‐free alternative to conventional barrier materials and establishes a tunable materials platform with potential relevance for biomedical devices and packaging systems requiring controlled oxygen permeability.

36 MATERIALS SCIENCE↗

ARM SGP PBLH and MLH datasets from Raman lidar and Doppler lidar

The planetary boundary layer (PBL) plays a critical role in the atmosphere by transferring heat, moisture, and momentum. The warm PBL has a distinct diurnal cycle including the daytime convective mixing layer (ML) and nighttime residual layer developments. Thus, simultaneous determinations of PBL height (PBLH) and ML height (MLH) are necessary for studying PBL characterization and processes. Here, new approaches are developed to provide reliable PBLH and MLH estimates to characterize warm PBL evolution. The approaches use Raman lidar (RL) water vapor mixing ratio (WVMR) and Doppler lidar (DL) vertical velocity measurements at the Southern Great Plains (SGP) atmospheric observatory, which was established by the Atmospheric Radiation Measurement (ARM) User Facility. Compared to widely used lidar aerosol measurements for PBLH, WVMR is a better tracer for PBL vertical mixing. For PBLH, the approach classifies PBL water vapor structures into a few general patterns, then uses a slope method and dynamic threshold method to determine PBLH. For MLH, wavelet analysis is used to reconstruct 2D variance from DL vertical wind velocity measurements according to the turbulence eddy size to minimize the impacts of gravity wave and eddy size on variance calculations; then, a dynamic threshold method is used to determine MLH. Remotely-sensed PBLHs and MLHs are compared with radiosonde measurements based on the Richardson number method. Good agreements between them confirm that the proposed new algorithms are reliable for PBLH and MLH characterization. The algorithms are applied to warm-season RL and ML measurements at the SGP site for five years to study warm-season PBL structure and processes. The weekly composited diurnal evolutions of PBLHs and MLHs in a warm climate were provided to illustrate diurnal and seasonal PBL evolutions. This reliable data set of PBLH and MLH values will be valuable for studying PBL processes, model evolution, and PBL parameterization improvements. The MLH dataset includes the MLH in values of km above ground level. The PBLH dataset includes the PBLH in values of km above ground level, along with a flag ("situation_PBLH") to determine the state of the PBL (1 = Cloudy Condition, 2 = Stable Layer, 3 = Multi-layer WVMR structure, 4 = Well-Mixed PBL, 5 = A de-coupled layer, 6 = Other).

mixing layer height↗

Cyclic oxidation behavior of selected commercial NiCr-alloys for engine exhaust valves in wet air environment between 800 and 950 °C

In this work, the impact of water vapor on the cyclic oxidation behavior of four commercial Ni-based superalloys (N80A, N90, R41 and H282) was investigated between 800 and 950°C. Oxidation- and volatilization-induced Cr loss accelerated the transition from protective and adherent oxide formation (Cr 2 O 3 ) to mixed oxides that significantly spalled at 950°C for H282 and R41. The accelerated oxidation, Cr depletion, and spallation susceptibility for R41 and to a lesser extent for H282 compared to N80A and N90 was related to the higher fraction of γ’, which led to increased Ti incorporation into the Cr 2 O 3 scale in the presence of water vapor.

36 MATERIALS SCIENCE↗

Raman Lidar (RL) Instrument Handbook

The Raman lidar at the ARM Climate Research Facility (ACRF) Southern Great Plains (SGP) Central Facility (SGPRL) is an active, ground-based laser remote sensing instrument that measures height and time resolved profiles of water vapor mixing ratio and several cloud- and aerosol-related quantities. The system is a non-commercial custom-built instrument developed by Sandia National Laboratories specifically for the ARM Program. It is fully computer automated, and will run unattended for many days following a brief (~5-minute) startup period. The self-contained system (requiring only external electrical power) is housed in a climate-controlled 8’x8’x20’ standard shipping container.

54 ENVIRONMENTAL SCIENCES↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ice Dusty Plasma (Final Report)

The NSF/DOE funding described in this final report was for constructing a substantial upgrade that would enable operation at variable and much lower cryogenic temperatures than was available in a previous experiment that operated from 2013 to 2019. Components for the upgraded experiment were designed and ordered from August to December 2019 and assembly began in early 2020. However, COVID-19 halted all lab work for much of 2020 and then when lab work resumed, numerous restrictions on lab access and in-lab time further impeded progress. Because of these delays, first plasma was obtained in late 2021 and a normal work pace resumed only in mid-2022. A no-cost extension was requested because the COVID-19 delays prevented work from being done at the anticipated rate. Constructing a water-ice experiment was a significant gamble because the parameter regime differs substantially from conventional laboratory plasmas and injecting water vapor into a plasma goes very much against convention as one normally goes to great lengths to avoid water vapor. This experiment opens a new frontier, namely the study of how charged ice grains form, grow, and interact with a plasma environment. The just-completed upgrade was a further gamble because it combines technology never previously used together (cryocoolers, plasma, and ice).

36 MATERIALS SCIENCE↗

Open-cycle thermochemical energy storage for building space heating: Practical system configurations and effective energy density

Salt-hydrate thermochemical materials (TCM) are promising candidates for energy storage systems for building space heating due to their high theoretical energy density and the need for low regeneration temperature. However, water vapor is required to drive the hydration process of the TCM reactor, which poses a challenge during winter when water vapor is typically scarce. Using indoor air directly lowers the building's humidity to an unconformable level in practice, while the cold outdoor air contains limited moisture. Here we consider different integration strategies for open-cycle TCM reactors in buildings and develop a model to simulate their thermal performance across diverse buildings and climates, specifically for building space heating. The potential energy densities and the levelized cost of storage of the TCM reactor are evaluated in practical scenarios to demonstrate the load-shifting potential of TCM systems for heating applications. We use a strontium chloride (SrCl 2 )-based composite as the baseline and explore the impact of various reactor and material changes to the energy density and levelized cost of storage.

25 ENERGY STORAGE↗

Influence of Proton Activity Gaps between Electrodes on Open-Circuit Potential of H 2 /H 2 and H 2 /Air Cells

Polymer -electrolyte-fuel-cell open-circuit voltages (OCVs) are exactly defined by equation (1), where cathode and anode proton activities [(aH+)cathode and (aH+)anode, respectively] usually are identical, so the third term in the right-hand side of equation (2) is ignored. OCV=E0+RT/2F*ln(a1/2 O2*(a2 H+)cathode/aH2O)-RT/2F*ln((a2 H+)anode/aH2) (1) =E0+RT/2F*ln(a1/2 O2*aH2/aH2O)+RT/2F*ln((a2 H+)cathode/(a2 H+)anode) (2) Water vapor pressure is a colligative property that fundamentally correlates to electrolyte concentrations in aqueous solutions. Proton activity is a function of acid concentration, such as pH, when electrolytes are acids. In polymer-electrolyte membranes, water vapor pressure and acid concentration are understood as relative humidity (RH) and water uptake (λ), respectively, where λ represents number of water molecules per sulfonic acid molecule. Several investigations have reported the relationship between RH and λ, meaning that proton activities and associated water uptakes are intimately related to RH. In actual fuel cell operation, cathode RH is determined by ambient-atmosphere and/or humidifier RH(s), and anode RH depends on hydrogen-circulator RH. Therefore, RH is not always identical at both electrodes, and the difference between electrode RHs is considerable during dry operation of polymer electrolyte fuel cells. Therefore, the third term in the right-hand side of equation (2) may be significant for dry operation. We measured OCVs when hydrogen was supplied to both electrodes at 80°C. One electrode (A) was fixed at 30% RH, while RH at the other electrode (B) was varied (0, 5, 10, 20, and 30%). Measured OCVs varied from 0 to 75 mV. For fuel cell tests, electrode A was supplied with hydrogen at 30% RH; electrode B, oxygen at 0, 5, 10, 20, and 30% RH. OCVs deviated from that measured when RH at electrode B was 30%, increasing from 0 to 60 mV with decreasing RH at electrode B. Results are also shown in Figure 1. Proton activities of both electrodes were thermodynamically calculated. The Gibbs–Duhem relation was applied to obtain molar Gibbs free energies of water and sulfonic acid, and proton activity coefficient was calculated using the Gibbs free energy of sulfonic acid and the relationship between RH and λ1–4, assuming that protons and sulfonic anions show identical ionic-activity coefficients. OCVs were estimated using the third term in the right-hand side of equation (2). Results are shown in Figure 1. Fuel-cell current–voltage performance was poor when RHs at the anode and cathode were 30 and 20%, respectively. To determine kinetic current, we measured the oxygen-reduction reaction (ORR) using a rotating-disk electrode (RDE) in concentrated-acid aqueous solutions, which modeled catalyst-layer ionomers. Kinetic currents decreased with acid concentrations. References T. A. Zawodzinski, Jr., C. Derouin, S. Radzinski, R. J. Sherman, V. T. Smith, T. E. Springer and S. Gottesfeld , J. Electrochem. Soc., 140,1041 (1993) P. K. Das and A. Z. Weber, Proceedings of the ASME 2013 11th Fuel Cell Science, Engineering and Technology Conference, Fuel Cell 18010 (2013) V. A. Sethuraman, J. W. Weidner, A. T. Haug, S. Motupally,b and L. V. Protsailo, J. Electrochem. Soc., 155, B50 (2008) A. Kusoglu and A. Z. Weber, Chem. Rev., 117, 987 (2017) Figure 1

Yoshida, Toshihiko↗

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS↗

Air Pollution Unable to Intensify Storms via Warm‐Phase Invigoration

Abstract According to the hypothesis of aerosol invigoration, the higher concentration of aerosols in polluted air intensifies storms. A leading theory for explaining such a relationship is warm‐phase invigoration, in which cloudy updrafts that are more polluted more readily condense water vapor onto liquid drops, thereby releasing latent heat faster, leading to higher buoyancies and higher updraft speeds. For this mechanism to work, water‐vapor supersaturations well in excess of 1% must be typical of relatively unpolluted cloudy updrafts. Here, the supersaturation is calculated from in situ observations of warm‐phase cloudy updrafts over the Amazon. Instead of values well in excess of 1%, the typical values are found to be around 0.2%. These observations imply that cleaner preindustrial air might have generated supersaturations around 1%, but those are still too low for warm‐phase invigoration to have any practically significant impact on cloud buoyancy and updraft speeds.

54 ENVIRONMENTAL SCIENCES↗

Planetary Boundary-Layer Height (PBLHT) Value-Added Product: Remote-Sensing Retrievals

The planetary boundary layer (PBL) is fundamental to numerous atmospheric processes, including aerosol mixing and transport, cloud evolution, and precipitation formation. A critical parameter in these studies is the PBL height (PBLHT). This vertical depth is essential for characterizing PBL structures in numerical simulations and serves as a primary metric for estimating flux exchanges between the Earth’s surface and the atmosphere. Radiosonde (SONDE) observations provide high-vertical-resolution measurements of temperature and moisture profiles and are widely used to estimate PBLHT (Liu and Liang 2010, Seidel et al. 2010). The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s PBLHT value-added product (VAP) for radiosonde measurements, known as PBLHTSONDE, applies three commonly used methods—the Heffter (1980) method, the Liu and Liang (2010) method, and the bulk Richardson number approach (Seibert et al. 2000)—to derive PBLHT. The PBLHTSONDE VAP operates routinely at ARM observatories and mobile facilities, with data available from the ARM Data Center shortly after sounding observations are collected (Sivaraman et al. 2013). However, radiosonde observations are limited by their low temporal resolution. Most stations launch soundings only twice daily, which constrains the ability to investigate and characterize the temporal evolution of the PBL using radiosonde data alone. The use of continuous remote-sensing observations provides high temporal resolution of PBLHT estimates. These observations include aerosol lidars (Dang et al. 2019, Su et al. 2020), Doppler lidar (DL; Tucker et al. 2009, Krishnamurthy et al. 2021), and water vapor and/or temperature lidars and radiometers (Turner et al. 2014). These observations provide valuable data on the PBL’s thermodynamic properties (e.g., water vapor and/or temperature lidars and radiometers), dynamic properties (e.g., DL), and distribution of tracer substances (e.g., aerosol lidars), all of which can be used to estimate PBLHT. ARM developed PBLHT estimates from the micropulse lidar (MPL; PBLHTMPL), Doppler lidar (PBLHTDL), and combined Raman lidar (RL)/atmospheric emitted radiance interferometer (AERI) thermodynamic profiles (PBLHTTHERMO). Each estimate captures different physical characteristics of the boundary layer—aerosol tracers, vertical velocity turbulence, and thermodynamic structure—and exhibits distinct strengths and limitations depending on the PBL regime and time of day. In addition, the ARM ceilometer (CEIL) provides three potential PBLHT candidates derived from the vendor's built-in algorithm. Building on these individual retrievals, ARM developed the PBLHTBEML VAP, which combines the four remote-sensing-based estimates with ancillary meteorological variables using the machine learning approach of Zhang et al. (2025) to produce a best-estimate PBLHT at 10-minute resolution.

54 ENVIRONMENTAL SCIENCES↗

Small molecule crystals with 1D water wires modulate electronic properties of surface water networks

This work evaluates the effect of water vapor pressure on the surface conductivity of a hydrated small molecule crystal under dry and wet conditions. The crystal contains a discrete metal complex with waters of hydration in structural positions and in 1D water wires. Under dry conditions, the surface of the hydrated crystal behaves as a near ideal capacitor. Under wet conditions, the waters of hydration serve as a template to assemble surface water networks by organization of water from the environment. The surface water provides pathways for charge transfer attributed to proton mobility that increases conductivity by > 3 orders in magnitude. Modulation between wet and dry conditions tunes the conductivity of the crystal surface via a two-step process, which has been evaluated kinetically as a function of the water vapor pressure.

36 MATERIALS SCIENCE↗

Numerical Water Tracers in the Atmospheric Component of the Energy Exascale Earth System Model: Implementation and Changes in Moisture Origin

Numerical water tracers are implemented in the Energy Exascale Earth System Model version 2. Simulations performed with the water‐tag‐enabled model for both pre‐industrial and future greenhouse gas concentrations reveal a marked increase in the role of mid‐latitude and southern subtropical regions as exporters of atmospheric moisture—to the extratropical upper troposphere and the tropical free troposphere. For the latter, the northward shift of the Intertropical Convergence Zone increases cross‐hemispheric transport of subtropical water vapor to the Northern Hemisphere. In the polar regions, most of the lower tropospheric moistening instead arises from increases in local evaporation. These findings illustrate the utility of the water tags, underscore critical changes in global hydrologic cycle, and provide insight into atmospheric dynamics under future climate scenarios. For applications when a global grid is desired, we additionally propose a novel statistical reconstruction, based on copula modeling, of the joint distribution of origin of water vapor, which reduces the number of tracers from order $\mathcal{O}\left({n}^{2}\right)$to order $\mathcal{O}(n)$, substantially ameliorating the considerable computational cost of water tracers. This statistical reconstruction is particularly beneficial to the interpretation of the relationship between latitude and longitude of origin of moisture over the tropical oceans and in the lower troposphere over land.

copula modeling↗

Trends in Warm Season Mesoscale Convective Systems Over Asia in 2001–2020

Mesoscale convective systems (MCSs) frequently occur over Asia during the warm season, often producing intense precipitation with associated socioeconomic impacts. Here we reveal significant trends in MCS occurrence frequency and related precipitation in Asia during the warm season (March–September) in 2001–2020, using a tracking method that combines cloud and precipitation criteria with high-resolution satellite data from the Global Precipitation Measurement mission. To examine whether there are differences between MCSs of different scales, both meso-α scales (MαCSs) and meso-β scales (MβCSs), with horizontal scales of 200–2,000 km and 20–200 km, are tracked. The distribution pattern of frequency and related precipitation of both MαCSs and MβCSs are quite similar and manifest positive trends over East Asia (EA) and Northeast Asia, and negative trend over Southeast Asia (SEA). The MCS precipitation trend contributes significantly to total precipitation trend, with MαCSs contributing the most. Our analysis indicates the trend in lower-tropospheric water vapor flux convergence has a similar spatial pattern to the MCS frequency and related precipitation trend. Based on an atmospheric moisture flux decomposition analysis, the water vapor flux convergence trend can largely be explained by the change in horizontal wind convergence, while the specific humidity trend driven largely by temperature change plays a minor role. In conclusion, the trend in wind convergence in EA and SEA is possibly related to the evident trend in the lower-tropospheric anticyclone over the western North Pacific and SEA, which might be due to the relatively stronger warming in the Indian Ocean during the past two decades.

54 ENVIRONMENTAL SCIENCES↗

A Concept of a Convection–Cloud Chamber to Study Aerosol–Cloud–Drizzle Interactions

Understanding and quantifying the full chain of processes from aerosol activation to drizzle formation, and the associated feedbacks to the aerosol chemical and physical properties, all within a turbulent cloud are some of the toughest challenges in atmospheric chemistry and physics and are keys to the cloud–precipitation puzzle. This paper describes a concept for a new type of research facility consisting of a cloud chamber plus associated instrumentation and computational models, to explore aerosol–cloud interactions and processing, cloud optical properties, entrainment–cloud interactions, and quantitative assessment of drizzle onset. The envisioned design is for a 3 m × 3 m × 9 m chamber, such that the height is sufficient to achieve long lifetimes for aerosol processing and for significant drizzle growth by collision and coalescence. A suite of computational tools for simulating microphysical properties in the chamber provides a digital twin for designing the chamber and a range of example experiments. Theory and test results from novel remote sensing systems for exploring chemical and physical interactions and evolution of aerosols, cloud droplets, and drizzle within turbulent clouds are described. Testing of technology needed for the operation of a large-volume chamber, including aerosol generation methods and novel materials for water vapor boundary conditions, is described. Simulations suggest that spatially uniform turbulence and microphysical properties can be sustained in a steady state, with reasonable aerosol and water vapor fluxes, and that substantial drizzle can be produced through collision and coalescence of cloud droplets. Remaining challenges for more detailed engineering design and a discussion of possible first-light experiments are described.

54 ENVIRONMENTAL SCIENCES↗