Search NASA⌕ Search

SEARCH · Search NASA

Results for “WETTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Environmental controls on isolated convection during the Amazonian wet season

The Amazon rainforest is a vital component of the global climate system, influencing the hydrological cycle and tropical circulation. However, understanding and modeling the evolution of convection in this region remain a scientific challenge. Here, we assess the environmental conditions associated with shallow, congestus, and isolated deep convection days during the wet season (December to April), employing measurements from the Green Ocean Amazon 2014–2015 (GoAmazon2014/5) experiment and large-scale wind fields from the constrained variational analysis. Composites of deep days show moister than average conditions below 3 km early in the morning. Analyzing the water budget at the surface through observations only, we estimated the water vapor convergence term as a residual of the water balance closure. Convergence remains nearly zero during the deep days until early afternoon (13:00 LST), when it becomes a dominant factor in the water budget. At 14:00 LST, the deep days experience a robust upward large-scale vertical velocity, especially above 4 km, which supports the shallow-to-deep convective transition occurring around 16:00–17:00 LST. In contrast, shallow and congestus days exhibit drier pre-convective conditions, along with diurnal water vapor divergence and large-scale subsidence that extend from the surface to the lower free troposphere. Moreover, afternoon precipitation exhibits the strongest linear correlation (0.6) with large-scale vertical velocity, nearly double the magnitude observed for other environmental factors, even moisture, at different levels and periods of the day. Precipitation also exhibits a moderate increase with low-level wind shear, while upper-level shear has a relatively minor negative impact on convection.

Environmental Sciences & Ecology↗

Weak influence of anthropogenic emissions on aerosol, cloud, and rain in the wet season of the Amazon rainforest

Anthropogenic emissions have been shown to affect new particle formation, aerosol concentrations, and clouds. Such effects vary with region, environmental conditions, and cloud types. In the wet season of Amazonia, anthropogenic emissions emitted from Manaus, Brazil, can significantly increase the cloud condensation nuclei (CCN) concentrations compared to the background of mainly natural aerosols. However, the regional response of cloud and rain to anthropogenic emissions in Amazonia remains very uncertain. Here, we aim to quantify how aerosol concentration, cloud, and rain respond to changes in anthropogenic emissions through parameterized new particle formation and primary aerosol emission in the Manaus region and to understand the underlying mechanisms. We ran the atmosphere-only configuration of the HadGEM3 climate model with a nested regional domain that covers most of the rainforest region (720 km by 1200 km with 3 km resolution) under scaled regional emissions. The 7 d simulations show that, in the areas that are affected by anthropogenic emissions, when aerosol and precursor gas emissions are doubled from the baseline emission inventories, aerosol number concentrations increase by 13 %. The nucleation rate that involves sulfuric acid and biogenic compounds generally increases with pollution levels. However, nucleation is suppressed very close to the pollution source, resulting in lower nucleation and soluble Aitken mode aerosol number concentrations. We also found that doubling the anthropogenic emission can increase the cloud droplet number concentrations ( N d ) by 9 %, but cloud water and rain mass mixing ratios do not change significantly. Even very strong reductions in aerosol number concentrations by a factor of 4, which is an unrealistic condition, cause only a 4 % increase in rain over the domain. If we assume our simulation has a fine enough grid resolution and an accurate representation of the relevant atmospheric processes, the simulated weak and non-linear response of cloud and rain properties to linearly scaled anthropogenic emissions suggests that the interactions among aerosol, cloud, and precipitation in the Amazonian convective environment are buffered by microphysical processes. It also implies that the convective environment is resilient to the changes in Nd that occur in response to localized anthropogenic aerosol perturbations.

Wang, Xuemei [University of Leeds (United Kingdom)↗

Wet-radome attenuation in ARM cloud radars and its utilization in radar calibration using disdrometer measurements

Abstract. A relative calibration technique has been developed for the US Department of Energy's (DOE's) Atmospheric Radiation Measurement (ARM) user facility Ka-band ARM Zenith Radars (KAZRs). This method uses the signal attenuation caused by water on the radome to estimate reflectivity factor (Ze) offsets. The wet-radome attenuation (WRA) is assumed to follow a log-linear relationship with rainfall rate during light and moderate rain, as measured by a collocated surface disdrometer. The technique has an uncertainty of approximately 3 dB, due to factors such as disdrometer measurement error, rain variability between radar and disdrometer sample volumes, and the fitting function's uncertainty for the WRA behavior. A practical advantage of this WRA-based approach to shorter-wavelength radar monitoring is that, while it requires a reference disdrometer, it proves feasible for a wider range of collocated disdrometer measurements compared to traditional direct disdrometer comparison at the onset of light rain. This technique thus offers a cost-effective monitoring tool for remote or long-term radar deployments. This calibration technique was applied during the ARM Tracking Aerosol Convection Interactions Experiment (TRACER) from October 2021 through September 2022. The estimated Ze offsets were compared against traditional radar calibration and monitoring methods using available datasets from this campaign. Results show that the WRA-based offsets align closely with mean offsets found between cloud radars and from direct disdrometer comparison near the onset of rain, while also reflecting similar offset and campaign-long trends when compared to collocated, independently calibrated radar wind profilers. Nevertheless, overall, the KAZR Ze offsets estimated during TRACER remained stable at approximately 2 dB lower than the disdrometer estimates from the campaign start until the end of June 2022; afterward, the offsets increased to around 7 dB by the campaign's end. This increase is linked to a drop of about 1 dB in transmitter power toward the end of the project.

54 ENVIRONMENTAL SCIENCES↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Controlled wetting and spreading of metals on substrates using porous interlayers and related articles

The disclosure generally relates to a method of creating patterned metallic circuits (e.g., silver circuits) on a substrate (e.g., a ceramic substrate). A porous metal interlayer (e.g., porous nickel) is applied to the substrate to improve wetting and adhesion of the patterned metal circuit material to the substrate. The substrate is heated to a temperature sufficient to melt the patterned metal circuit material but not the porous metal interlayer. Spreading of molten metal circuit material on the substrate is controlled by the porous metal interlayer, which can itself be patterned, such as having a defined circuit pattern. Thick-film silver or other metal circuits can be custom designed in complicated shapes for high temperature/high power applications. The materials designated for the circuit design allows for a low-cost method of generating silver circuits other metal circuits on a ceramic substrate.

Nicholas, Jason Dale↗

Lessons Learned From Ventilation and Glovebox Flooding Via Overfilling of the Wet Vacuum System in a Plutonium Facility

In the summer of 2021, operations personnel requested maintenance personnel to fill a wet vacuum (Wetvac) seal water tank in a plutonium facility at Los Alamos National Laboratory (LANL). After the filling was finished, the fill valve of the Wetvac seal water tank was left open and a ‘dead-man’ valve on an isolation line failed to close properly. After a series of other failures, the water exited the glovebox and contaminated three rooms of the first floor of the facility and an underlying area in the basement. A retrospective analysis of this event determined that there was no risk of a criticality due to the inherent design features of the ventilation system. This paper will explain the driving factors behind how this event was able to happen, as well as some of the major lessons learned that can be universally applied to other nuclear facilities. One of the main causes of the event was the delegation of work to maintenance personnel that were not qualified for the work being asked of them. Additionally, there was a lack of coordination between criticality safety engineers and facility operations equipment owners regarding equipment and connections present on the seal water tanks for the Wetvac, specifically the presence of overflow drain lines. The respective criticality safety evaluation credited an overflow drain line being present on the seal water tanks that was later found to have not been present. Lastly, there are lessons to be learned regarding equipment configuration and designing systems with safety in mind.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems, devices, and methods of enhancing carbon fiber dispersion in wet-laid nonwovens

The present subject matter relates to systems, devices, and methods of enhancing carbon fiber dispersion in wet-laid nonwovens. A quantity of fibers is deposited in a medium, and each of one or more stirring elements is moved in a pattern to mechanically agitate the medium. In some embodiments, moving each of the one or more stirring elements includes moving the one or more stirring elements in complementary patterns to induce a chaotic advection current within the medium.

Ghossein, Hicham Kheir↗

Drying Wet Stored and Corroded Magnox Fuel for Interim Dry Storage - 20187

To investigate the feasibility of drying corroded Magnesium alloy clad nuclear fuel, the corrosion products of inactive and unirradiated Magnox simulant dry corrosion product and dried corroded Magnox sludge were characterised by X-ray diffraction and thermogravimetric analysis. XRD identified brucite in the dried corrosion product and both brucite and hydromagnesite in the sludge. TGA identified mass loss on dehydration of ∼9.1% up to 250 deg. C and 27.9% from dehydroxylation up to 440 deg. C, with total mass loss of 41.9% up to 800 deg. C for the dried corrosion product. The sludge TGA showed 8.3% mass loss up to 250 deg. C from dehydration, 7.5% up to 330 deg. C from dehydroxylation and 31.4% mass loss up to 47.2% for decarbonation, with total mass loss of 49.2% up to 800 deg. C. Water removal up to 1.8 g was performed by cold vacuum drying (40 deg. C-120 deg. C) on a ≅14.8 g (wet) corroded Magnox sample. The process was monitored by observing pressure, dew point, temperature and gas flow changes supported by measuring the sample mass loss as water is removed. From these tests, it was observed that the dried corroded Magnox displayed some hygroscopic capacity which has implications for water retention following vacuum drying and the length of exposure required to achieve the desired dryness. Whilst at higher temperatures the water was removed faster, the increased temperature also risks the fuel cladding undergoing unwanted chemical reactions with the residual water during the process. However, at lower temperatures the achievable levels of dryness were reduced. Therefore, from these observations this work has identified that there is a temperature balance that may be necessary to optimise the drying process with respect to allowing the greatest level of dryness whilst restricting unwanted chemical reactions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Role of surface wetting on tribological behavior for laser nanotextured steel using ionic liquid lubricants

Here, this research evaluates the effect of surface wettability on the tribological performance through ball-on-flat tribology testing. The substrate material, M2 tool steel, is laser processed and then functionalized with fluorocarbon and nitrile chemistry to achieve distinct oleophobicity and oleophilicity, respectively, but with a similar nanoscale surface texture. The baseline lubricant is poly-alpha-olefin (PAO) oil, and ionic liquids (ILs) are used as additives for this study. The interaction between the nanoscale textured steel surface and ionic liquid-based oils is investigated. A set of reciprocating wear tests are performed to investigate the tribological behavior of the tribo-system consisting of the surface-engineered, flat M2 tool steel specimen and a standard, surface-polished steel ball. Results show that the oleophobic flat surface results in a lower friction, while the oleophilic surface modification leads to a better wear protection to the flat surface. Ammonium-based IL provides the highest friction reduction, while the phosphonium-based ILs provide an improved wear protection.

36 MATERIALS SCIENCE↗

Extended catalyst lifetime testing for HTL biocrude hydrotreating to produce fuel blendstocks from wet wastes

This paper presents the upgrading of HTL (Hydrothermal Liquefaction) bio oil produced by from various sources such as sewage sludge and food wastes. The HTL oil was hydrotreated over a CoMo/Al2O3 (guardbed) and NiMo/Al2O3 (mainbed) catalysts at WHSV 0.5hr-1, 400°C and 1500 psi. The steady state densities (at 40°C) were 0.79 and 0.81 g/ml for HTL biocrude derived from sewage sludge and food waste, respectively. After 1500 hours of steady state operation, variations in process conditions that affect the hydrotreating performance had been identified in the following order; Pressure>WHSV>Temperature. Pressure had huge impact on the hydrotreating performance. The hydrotreating efficiency was reestablished to base line conditions with minimal deactivation of catalyst at 2000 hours run time.

Hydrothermal Liquefaction, HTL, Hydrotreating, Bio↗

Experimental warming and its legacy effects on root dynamics following two hurricane disturbances in a wet tropical forest

Abstract Tropical forests are expected to experience unprecedented warming and increases in hurricane disturbances in the coming decades; yet, our understanding of how these productive systems, especially their belowground component, will respond to the combined effects of varied environmental changes remains empirically limited. Here we evaluated the responses of root dynamics (production, mortality, and biomass) to soil and understory warming (+4°C) and after two consecutive tropical hurricanes in our in situ warming experiment in a tropical forest of Puerto Rico: Tropical Responses to Altered Climate Experiment (TRACE). We collected minirhizotron images from three warmed plots and three control plots of 12 m 2 . Following Hurricanes Irma and María in September 2017, the infrared heater warming treatment was suspended for repairs, which allowed us to explore potential legacy effects of prior warming on forest recovery. We found that warming significantly reduced root production and root biomass over time. Following hurricane disturbance, both root biomass and production increased substantially across all plots; the root biomass increased 2.8‐fold in controls but only 1.6‐fold in previously warmed plots. This pattern held true for both herbaceous and woody roots, suggesting that the consistent antecedent warming conditions reduced root capacity to recover following hurricane disturbance. Root production and mortality were both related to soil ammonium nitrogen and microbial biomass nitrogen before and after the hurricanes. This experiment has provided an unprecedented look at the complex interactive effects of disturbance and climate change on the root component of a tropical forested ecosystem. A decrease in root production in a warmer world and slower root recovery after a major hurricane disturbance, as observed here, are likely to have longer‐term consequences for tropical forest responses to future global change.

54 ENVIRONMENTAL SCIENCES↗

Wetting Properties of Molten Salts

Wettability is a key piece of information in understanding the behavior of molten salts at material interfaces. Wettability is most easily characterized by contact angle which is measurable using the sessile drop method. A modified sessile drop method was used to measure the contact angle of the LiCl-KCl eutectic at varying temperatures on Nickel 200, Hastelloy C276, Glassy Carbon, and MACOR machinable ceramic. The contact angle was used with existing surface temperature data to find the work of adhesion at various temperatures. Finally, problems encountered during the experiment are listed and possible improvements are provided.

36 MATERIALS SCIENCE↗

Dry and Wet CO 2 Capture from Milk‐Derived Microporous Carbons with Tuned Hydrophobicity

Abstract Pore size distribution and surface chemistry of bio‐derived (milk) microporous dominated carbon “MDC” is synergistically tuned, allowing for promising carbon capture in a dry CO 2 atmosphere and in mixed H 2 O–CO 2 . The capture capacity is attributed to the synergy of a large total surface area with an ultramicroporous and microporous texture (e.g., S tot 1889 m 2 g −1 , S mic 1755 m 2 g −1 , S ultra 1393 m 2 g −1 ), and a high content of nitrogen and oxygen heteroatom moieties (e.g., 5 at% N, 10.5 at% O). Tailored two‐step low‐temperature pyrolysis‐chemical activation is employed to take advantage of the intrinsic properties of the precursor, allowing for this unusual textural properties‐heteroatoms combination. For example, tested at 1 bar and 295 or 273 K, MDCs adsorb up to 22.0 and 29.4 wt% CO 2 , respectively. MDCs are also tailored to be hydrophobic, with CO 2 /H 2 O adsorption selectivity even after prolonged cycling. Maximum working capacities of 10.8 wt% for pure CO 2 and 3.5 wt% for a flue gas simulant (15% CO 2 , 85% N 2 ) are measured using temperature swing adsorption with dynamic purge gases, while being minimally affected by humid conditions. This work is directly aligned with the United Nation’s Sustainable Development Goal 13, take urgent action to combat climate change and its impacts.

Pokrzywinski, Jesse↗