Search NASA⌕ Search

SEARCH · Search NASA

Results for “Water Demands”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Evaluation of Global Climate Models for Use in Energy Analysis

The interplay between energy, climate, and weather is becoming more complex due to increasing contributions of renewable energy generation, energy storage, electrified end uses, and the increasing frequency of extreme weather events. Energy system analyses commonly rely on meteorological inputs to estimate renewable energy generation and energy demand; however, these inputs rarely represent the estimated impacts of future climate change. Climate models and publicly available climate change datasets can be used for this purpose, but the selection of inputs from the myriad of available models and datasets is a nuanced and subjective process. In this work, we assess datasets from various global climate models (GCMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). We present evaluations of their skills with respect to the historical climate and comparisons of their future projections of climate change for two climate change scenarios. We present the results for different climatic and energy system regions and include interactive figures in the accompanying software repository. Previous work has presented similar GCM evaluations, but none have presented variables and metrics specifically intended for comprehensive energy systems analysis including impacts on energy demand, thermal cooling, hydropower, water availability, solar energy generation, and wind energy generation. We focus on GCM output meteorological variables that directly affect these energy system components including the representation of extreme values that can drive grid resilience events. The objective of this work is not to recommend the best climate model and dataset for a given analysis, but instead to provide a reference to facilitate the selection of climate models and scenarios in subsequent work.

14 SOLAR ENERGY↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

Security-by-Design: Light Water Small Modular Reactor

The growing demand for nuclear power is increasing pressure to find solutions to cost prohibitive requirements of both construction and security. Offsite response has been proposed as an option to reduce costs associated with training and maintaining an onsite response force. A previous report explored this option and revealed that security could be provided at the required level, but cost savings was not a result of this methodology. An offsite response strategy required costly active and passive delay barriers to provide sufficient time for responders to muster and deploy to a site in time to interrupt a determined and well-equipped adversary. Also, contrary to the hypothesis, the number of responders required for this strategy exceeded that needed for an onsite response force, as the adversaries could avail themselves of advantageous positions within the facility to repel arriving responders. This report builds upon the previous evaluation by using the same hypothetical light water small modular reactor (LWSMR) facility model, but this time an onsite response strategy was assessed. The goal of this analysis was to show that an onsite response strategy could be implemented effectively at a cost point that removes barriers within the industry at this critical time of growth and development. The assessment of the facility design and response strategy was completed through modeling using Scribe3D© and subsequent scenario analysis over the course of a two-day tabletop exercise. Subject matter experts in nuclear security, nuclear facility design, and response strategy and tactics contributed to the effort to ensure accurate representation of hypothetical scenarios. Several adaptations were made to the layout of the LWSMR based on lessons learned during the first day of scenario analysis. The subsequent design evaluated on the second day proved to provide a robust response posture against a large and well-trained adversary force. This report details the process of the analysis and compares the cost of the final facility design with that of the LWSMR model used for evaluation of offsite response. Ultimately, the results of this effort indicate that, when implemented correctly, an onsite response strategy is the best option from a security and cost perspective.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancing Diagnostic Model Evaluation to Better Understand Water Shortage Mechanisms in Institutionally Complex River Basins

Abstract Water resources systems models enable valuable inferences on consequential system stressors by representing both the geophysical processes determining the movement of water and the human elements distributing it to its various competing uses. This study contributes a diagnostic evaluation framework that pairs exploratory modeling with global sensitivity analysis to enhance our ability to make inferences on water scarcity vulnerabilities in institutionally complex river basins. Diagnostic evaluation of models representing institutionally complex river basins with many stakeholders poses significant challenges. First, it needs to exploit a large and diverse suite of simulations to capture important human‐natural system interactions as well as institutionally aware behavioral mechanisms. Second, it needs to have performance metrics that are consequential and draw on decision‐relevant model outputs that adequately capture the multisector concerns that emerge from diverse basin stakeholders. We demonstrate the proposed model diagnostic framework by evaluating how potential interactions between changing hydrologic conditions and human demands influence the frequencies and durations of water shortages of varying magnitudes experienced by hundreds of users in a subbasin of the Colorado River. We show that the dominant factors shaping these effects vary both across users and, for an individual user, across percentiles of shortage magnitude. These differences hold even for users sharing diversion locations, demand levels or water right seniority. Our findings underline the importance of detailed institutional representation for such basins, as institutions strongly shape how dominant factors of stakeholder vulnerabilities propagate through the complex network of users.

Hadjimichael, Antonia↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Magnetic Nanoparticle Extraction of Lithium from Produced Waters - CRADA 483 (Final Report)

The demand for lithium in the energy production industry is expected to increase sharply, development of simple and cost-effective techniques for lithium production and recovery from various lithium sources is essential. In this project, core/shell magnetic nanoparticles were successfully designed to selectively extract lithium from aqueous lithium sources as an extension of Pacific Northwest National Laboratory’s magnetic nanofluid extraction technology. The core/shell magnetic nanoparticles are composed of manganese oxide-based lithium ion sieve shells, which allow selective lithium uptake from brines with multiple coexisting ions, over iron oxide cores, which can respond to external magnetic fields for effective recovery and reuse of adsorbents from a liquid. The synthesized lithium ion-sieves and core/shell magnetic nanoparticles were characterized using several techniques to reveal their crystallinity and morphology. The lithium uptake properties of the lithium ion-sieves and core/shell magnetic nanoparticles were evaluated in terms of lithium adsorption capacity, removal percentage, selectivity, and cycling performance in simulated and natural brines. Magnetic properties of the core/shell magnetic nanoparticles were tested by measuring magnetic saturation, and magnetic response of colloidal solutions containing the core/shell magnetic nanoparticles was tested with permanent magnets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparison of the Environmental Effects of Open-Loop and Closed-Loop Pumped Storage Hydropower

Pumped storage hydropower (PSH) is a type of energy storage that uses the pumping and release of water between two reservoirs at different elevations to store water and generate electricity (Figure ES-1). When demand for electricity is low, a PSH project can use low cost energy to pump water from the lower reservoir to the upper reservoir for storage. When demand for electricity is high, a PSH project can release water from the upper reservoir through a powerhouse to generate electricity. Traditionally, this meant that PSH plants generated power during the day and pumped at night, with modest diurnal or seasonal variation.

13 HYDRO ENERGY↗

Intercalated water in aqueous batteries

The unprecedentedly growing demand for energy storage devices in recent years calls for diversified chemistries with unique advantages. When it comes to safety and cost, aqueous battery systems have attracted tremendous attention. Being a universal solvent, water can solvate the cations with rather high dehydration energy due to the hydrogen bonding environment, relatively small size and high polarity. Such properties make solvent co-intercalation, which is seen in a few of the non-aqueous systems, more likely to happen in aqueous batteries. Hydrated cations show drastically different behaviors from naked cations during intercalation/de-intercalation processes and hence enable many reactions that are otherwise difficult to proceed. This review summarizes the roles of co-intercalated water in aqueous batteries from how water molecules coordinate with cations to examples of water-mediated reactions in different types of host materials.

25 ENERGY STORAGE↗

Long-term socioeconomic trends and climate variability as drivers of virtual water scarcity in China

Water scarcity can have far-reaching sectoral impacts beyond its physical location through the propagation of virtual water flows. Socioeconomic and hydroclimatic changes affect local and virtual water scarcity by altering availability and demand. Yet most studies of this phenomenon focus on volumetric footprints, and the few on water scarcity risk have not examined hydroclimatic variability beyond long-term trends. In this study, we ask how gross domestic product (GDP) and population changes, long-term meteorological trends, sea surface temperature (SST) patterns, and interannual meteorological variability affect water scarcity in China, both locally (through the local water scarcity risk index, LWSR) and remotely (through the virtual water scarcity risk index, VWSR). Counterfactual scenarios were compared in a regression-and-simulation framework, with the socioeconomic and meteorological drivers varying over 1923–2019 and the multi-regional input–output structure staying fixed at 2017. Relative to a 5 year baseline centered on 2017, GDP and population changes have induced a cumulative 17%–50% increase in LWSR and 13%–21% increase in VWSR, outweighing the effect of long-term meteorological trends. phase change in one of two examined SST patterns induce 4%–13% differences in LWSR and 1%–4% differences in VWSR. Interannual meteorological variability induces 10%–20% standard deviations in LWSR and 3%–7% in VWSR. The findings highlight the importance of using longer time series to accurately assess local and virtual water scarcity situations. Water scarcity management should prioritize socioeconomic factors when planning at century-long timescales and prioritize hydroclimatic factors at multidecadal or shorter timescales. water managers should consider interannual variabilities in LWSR and VWSR and plan for potential occurrences of extreme conditions.

climate variability↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

The Conventional Gas Diffusion Electrode May Not Be Resistant to Flooding during CO 2 /CO Reduction

The electrochemical CO 2 or CO reduction to chemicals and fuels using renewable energy is a promising way to reduce anthropogenic carbon emissions. The gas diffusion electrode (GDE) design enables low-carbon manufacturing of target products at a current density (e.g., 500 mA cm –2 ) relevant to industrial requirements. However, the long-term stability of the GDE is restricted by poor water management and flooding, resulting in a significant hydrogen evolution reaction (HER) within almost an hour. The optimization of water management in the GDE demands a thorough understanding of the role of the gas diffusion layer (GDL) and the catalyst layer (CL) distinctively. In this work, the hydrophobicity of the GDL and CL is independently adjusted to investigate their influence on gas transport efficiency and water management. The gas transport efficiency is more enhanced with the increase in hydrophobicity of the GDL than the CL. Direct visualization of water distribution by optical microscope and micro-computed tomography demonstrates that the water flow pattern transfers from the stable displacement to capillary fingering as GDL hydrophobicity increases. Unfortunately, only increasing the hydrophobicity is not sufficient to prevent flooding. A revolutionary change in the design of the GDE structure is essential to maintain the long-term stability of CO 2 /CO reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intermediate Sr 2 Co 1.5 Fe 0.5 O 6-δ Tetragonal Structure between Perovskite and Brownmillerite as a Model Catalyst with Layered Oxygen Deficiency for Enhanced Electrochemical Water Oxidation

The generation of hydrogen in an environmentally benign way is highly essential to meet future energy demands. However, in the process of splitting water electrochemically, sluggish kinetics of the oxygen evolution reaction (OER) curtails its applicability, as it drags energy input. Herein, we synthesized SrCo-Fe-O oxides to optimize their OER activity by varying the Co/Fe ratio. Among them, Sr 2 Co 1.5 Fe 0.5 O 6-δ exhibited the best OER catalytic activity in the series, with an overpotential of 318 mV at 10 mA cm -2 and Tafel slope of 44.8 mV dec -1 . High-resolution neutron powder diffraction analysis identified an intermediate structure between the perovskite and brownmillerite, with alternating layers of disorderly orientated oxygen-deficient tetrahedra and fully stoichiometric octahedra. The unique stacking of tetrahedral and octahedral units facilitates desired interactions between the electrode surface and electrolyte. Theoretical calculations revealed that increased covalency of Co 3d and O 2p in Sr 2 Co 1.5 Fe 0.5 O 6-δ oxide is another primary contributor to its augmented water oxidation ability. As a model for developing catalysts with such an intermediate structure, the synergetic effect of oxygen vacancy and hybridization between Co 3d and O 2p assured the Sr 2 Co 1.5 Fe 0.5 O 6-δ oxide as a better catalyst for its enhanced OER activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Domestic Hot Water Temperature Maintenance Technology Review

Domestic hot water temperature maintenance (HWTM) is an important topic in facility management, and there are often opportunities to optimize systems to achieve energy, water, and maintenance savings. The main purpose of an HWTM system is to provide reliable hot water temperature at all fixtures with minimal wait time. This is done by replacing the standby heat losses from hot water sitting idle in pipes during periods of low demand. Traditionally, most commercial buildings do this by having water recirculate back to the water heater to be reheated. Other currently available HWTM systems are also discussed in this resource. HWTM systems can help maintain water at appropriate temperatures, minimize heat loss, and minimize delivery times to fixtures to improve the function of a building. This webpage includes a summary of HWTM options along with important considerations regarding occupant safety and comfort, and maintenance strategies for optimal and efficient operations. Domestic hot water (DHW) generation systems are referred to but are not the focus of this resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing energy demand and environmental impact for sustainable NH 3 and H 2 O 2 production—A perspective on contributions from thermal, electro-, and photo-catalysis

There is an urgent need to provide adequate and sustainable supplies of water and food to satisfy the demand of an increasing population. Catalysis plays important roles in meeting these needs by facilitating the synthesis of hydrogen peroxide that is used in water decontamination and chemicals production, and ammonia that is used as fertilizer. However, these chemicals are currently produced with processes that are either very energy-intensive or environmentally unfriendly. This article offers the perspectives of the challenges and opportunities in the production of these chemicals, focusing on the roles of catalysis in more sustainable, alternative production methods that minimize energy consumption and environmental impact. While not intended to be a comprehensive review, the article provides a critical review of selected literature relevant to its objectives, discusses areas needed for further research, and potential new directions inspired by new developments in related fields. For each chemical, production by thermal, electro-, and photo-excited processes are discussed. Problems that are common to these approaches and their differences are identified and possible solutions suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Future changes in the trading of virtual water

Water stressed regions rely heavily on the import of water-intensive goods to offset insufficient food production driven by socioeconomic and environmental factors. The water embedded in these traded commodities, virtual water, has received increasing interest in the scientific community. However, comprehensive future projections of virtual water trading remain absent. Here we show, for the first time, changes over the 21st century in the amount of various water types required to meet international agricultural demands. Accounting for evolution in socioeconomic and climatic conditions, we estimate future interregional virtual water trading and find trading of renewable water sources may triple by 2100 while nonrenewable groundwater trading may at least double. Basins in North America, and the La Plata and Nile Rivers are found to contribute extensively to virtual water exports, while much of Africa, India, and the Middle East relies heavily on virtual water imports by the end of the century.

54 ENVIRONMENTAL SCIENCES↗

Permeate fluxes from desalination of brines and produced waters: A reactive transport modeling study

The increasing interest in the use of membrane systems to desalinate inland brackish water, agricultural drainage, and industrially produced wastewater demands improved means of predicting desalination system performance under variable feedwater compositions. The interaction among water flow, solute transport, and chemical composition in these systems impacts permeate flux evolution. Here, an established multicomponent reactive transport simulator that accounts for these coupled processes is applied to compute osmotic pressure and permeate fluxes in reverse osmosis (RO) systems. The model is first validated by predicting permeate fluxes for a set of benchtop crossflow experiments subject to a range of feed flow rates and compositions, under fouling and non-fouling conditions. Results compare favorably with measured data that show that solutions with similar total dissolved solids concentrations but different compositions result in different permeate fluxes. The model is then applied to predict permeate fluxes from the desalination of produced waters using a commercial spiral wound RO module. For NaCl-dominant brines, at total dissolved salt concentrations (TDS) below about 70 g/L, permeate fluxes are inversely proportional to water mole fraction as the latter is a reasonable approximation of water activity (i.e. ideal mixing). In the case of Ca–Cl-, Na–CO3- and Na–SO4-dominant brines below about 70 g/L TDS, this relationship does not hold as well and tends to overpredict osmotic pressure and thus underpredict permeate fluxes. However, the opposite becomes true at higher TDS values for typical produced waters. The scaling potential of these waters is also computed by allowing the precipitation of minerals above their saturation limit on the RO membrane. This work demonstrates how reactive transport models developed for the analysis of waters from geological systems can be extended to improve process design, optimization, and control in desalination systems from produced waters and beyond.

Molins, Sergi↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗