Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wicked”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Analysis and tests of NASA coverted groove heat pipe

A low-cost thermal control heat pipe having nearly covered grooves extruded in aluminum was developed at NASA. Analytical predictions of transport capability are in excellent agreement with experimental results using ammonia. Axial heat transport predictions as a function of fluid charge are presented also for methane, ethane, propane, and butane. Experimental tests show performance considerably better than that of open groove extruded pipes and comparing favorably with that of more complicated arterial/wick configurations. For ammonia at 20 C, the covert groove pipe obtained a static wicking height of 2.5 cm and an axial heat transport capability of 143 W-m.

Source record↗

Flat-plate heat pipe

Flat plate (vapor chamber) heat pipes were made by enclosing metal wicking between two capillary grooved flat panels. These heat pipes provide a unique configuration and have good capacity and conductance capabilities in zero gravity. When these flat plate vapor chamber heat pipes are heated or cooled, the surfaces are essentially isothermal, varying only 3 to 5 C over the panel surface.

Marcus, B. D.↗

Properties and applications of a pitch carbon microsphere composite

Some properties and applications of a pitch carbon microsphere composite are described. The small hollow microspheres are made from the pitch which is usually a wasted by-product of petroleum refining. In contrast to high density composites or syntactic foams in which microspheres are inclusions within a continuous matrix, this composite is an aggregate of microspheres bonded together by a small amount of thermosetting polymer which does not form a continuous matrix. The result is a composite with low density and thermal expansion, modest strength and rigidity, and high porosity and carbon content. Mechanical, thermal, and sorption properties have been measured. Applications of the composite include honeycomb filler for high temperature or ionizing radiation fields and a wicking absorber for solar-powered stills.

Price, H. L.↗

Excess liquid in heat-pipe vapor spaces

A mathematical model is developed of excess liquid in heat pipes that is used to calculate the parameters governing the axial flow of liquid in fillets and puddles that form in vapor spaces. In an acceleration field, the hydrostatic pressure variation is taken into account, which results in noncircular meniscus shapes. The two specific vapor-space geometries considered are circular and the 'Dee-shape' that is formed by a slab wick in a circular tube. Also presented are theoretical and experimental results for the conditions under which liquid slugs form at the ends of the vapor spaces. These results also apply to the priming of arteries.

Eninger, J. E.↗

Re-entrant groove heat pipe

This paper describes theoretical and experimentally verified heat pipe characteristics of an axially grooved aluminum extrusion with a re-entrant groove profile. The extrusion is 13 mm diameter with 20 axial grooves, each groove consisting of a nominal .8 mm diameter channel with a .2 mm wide passageway connecting the channel to the hollow core. A computer program was written to compute the zero gravity heat transport capability of the extrusion. A heat pipe was fabricated and its performance characteristics measured. The characteristics of the pipe with ammonia at 20 C are: zero gravity pumping limit 143 w-meters; static wicking height 21.5 mm; evaporator and condenser coefficients 7300 and 20,500 watt/sq m C, respectively.

Harwell, W.↗

A structured surface for high performance evaporative heat transfer

An evaporative surface is described for heat pipes and other two-phase heat transfer applications that consists of a hybrid composition of V-grooves and capillary wicking. Characteristics of the surface include both a high heat transfer coefficient and high heat flux capability relative to conventional open faced screw thread surfaces. With a groove density of 12.6/cm and ammonia working fluid, heat transfer coefficients in the range of 1 to 2 W/sq cm K have been measured, along with maximum heat flux densities in excess of 20 W/sq cm. A peak heat transfer coefficient in excess of 2.3 W/sq cm K at 20 W/sq cm was measured with a 37.8/cm hybrid surface.

Saaski, E. W.↗

Centaur propellant thermal conditioning system

An upgraded Centaur capability was studied by investigating three main areas: (1) Analytical and experimental investigation of promising capillary pumping concepts for passive cooling of cryogenic capillary acquisition devices resulted in selection, test, and empirical correlation of four wicking configurations. Only plate/screen-screen/plate and plate/screen-plate/screen configurations would function successfully under worst-case Centaur D-1S conditions. Weight estimates were developed for the passively cooled configurations and comparisons were made of passive and actively cooled capillary devices. (2) Thermal subcoolers for replacing pressurization and boost pump systems for three engine candidates and three Centaur D-1S missions were evaluated for several feed system configurations. Analysis included both transient and steady-state operation. Weight comparisons were made among feed system alternatives. (3) Existing experimental mixing studies to destroy thermal stratification were evaluated to determine the best mixing correlation to fit all available data. The correlation was then used to modify a computer program to size thermodynamic vent systems for Shuttle-based Centaur derivatives.

Blatt, M. H.↗

Flat-plate heat pipe

Heat pipe has its working fluid sealed between two flat panels rather than in conventional cylindrical housing. Metal wick is installed between planes to provide continuous fluid path in cooperation with capillary groves on inside surfaces of plates. Heat pipe is easily coupled to flat surfaces such as integrated circuit substrates, mirrors, and electronic cold plates and is more effective than conventional heat pipes when removing heat in these applications.

Fleischman, G. L.↗

Study of a high performance evaporative heat transfer surface

An evaporative surface is described for heat pipes and other two-phase heat transfer applications that consists of a hybrid composition of V-grooves and capillary wicking. Characteristics of the surface include both a high heat transfer coefficient and high heat flux capability relative to conventional open-faced screw thread surfaces. With a groove density of 12.6 cm/1 and ammonia working fluid, heat transfer coefficients in the range of 1 to 2 W/sq cm have been measured along with maximum heat flux densities in excess of 20 W/sq cm. A peak heat transfer coefficient in excess of 2.3 W/sq cm was measured with a 37.8 cm/1 hybrid surface.

Saaski, E. W.↗

Apollo-Soyuz pamphlet no. 8: Zero-g technology

The behavior of liquids in zero gravity environments is discussed with emphasis on foams, wetting, and wicks. A multipurpose electric furnace (MA-010) for the high temperature processing of metals and salts in zero-g is described. Experiments discussed include: monolectic and synthetic alloys (MA-041); multiple material melting point (MA-150); zero-g processing of metals (MA-070); surface tension induced convection (MA-041); halide eutectic growth; interface markings in crystals (MA-060); crystal growth from the vapor phase (MA-085); and photography of crystal growth (MA-028).

Page, L. W.↗

Development of a cryogenic rotating heat pipe joint

The performance of two critical technology components required for a continuously rotatable heat pipe: (1) a low-leakage rotatable coupling for the heat pipe pressure vessel, and (2) a rotatable internal wick, is reported. Performance and leakage requirements were established based on 12 months operation of a cryogenic rotatable heat pipe on a satellite in earth orbit.

Source record↗

Thermal energy transformer

For use in combination with a heat engine, a thermal energy transformer is presented. It is comprised of a flux receiver having a first wall defining therein a radiation absorption cavity for converting solar flux to thermal energy, and a second wall defining an energy transfer wall for the heat engine. There is a heat pipe chamber interposed between the first and second walls having a working fluid disposed within the chamber and a wick lining the chamber for conducting the working fluid from the second wall to the first wall. Thermal energy is transferred from the radiation absorption cavity to the heat engine.

Berdahl, C. M.↗

Configuration analysis of nickel hydrogen cell

The significance of various stack configurations and components on the cycle life for nickel hydrogen cells for synchronous orbit used was evaluated. Failure modes of electrolyte management and 02 management were solved by modifications in the reservoir, the wick, and/or the stack configuration.

Holleck, G.↗

Lithium and potassium heat pipes for thermionic converters

A prototypic heat pipe system for an out-of-core thermionic reactor has been built and tested. The emitter of the concentric thermionic converter consists of the condenser of a tungsten heat pipe utilizing a lithium working fluid. The evaporator section of the emitter heat pipe is radiation heated to simulate the thermal input from the nuclear reactor. The emitter heat pipe thermal transport is matched to the thermionic converter input requirement. The collector heat pipe of niobium, 1%-zirconium alloy uses potassium as the working fluid. The thermionic collector is coupled to the heat pipe by a tapered conical joint designed to minimize the temperature drop. The area ratio of the evaporator to condenser is 16:1, which increases the radiation area. The composite wick structure consists of seven arteries and cylindrical wraps. The collector heat flux matches the design requirements of the thermionic converter.

Miskolczy, G.↗

Capillary acquisition devices for high-performance vehicles: Executive summary

Technology areas critical to the development of cryogenic capillary devices were studied. Passive cooling of capillary devices was investigated with an analytical and experimental study of wicking flow. Capillary device refilling with settled fluid was studied using an analytical and experimental program that resulted in successful correlation of a versatile computer program with test data. The program was used to predict Centaur D-1S LO2 and LH2 start basket refilling. Comparisons were made between the baseline Centaur D-1S propellant feed system and feed system alternatives including systems using capillary devices. The preferred concepts from the Centaur D-1S study were examined for APOTV and POTV vehicles for delivery and round trip transfer of payloads between LEO and GEO. Mission profiles were determined to provide propellant usage timelines and the payload partials were defined.

Blatt, M. H.↗

Lubrication of rolling-element bearings

The lubrication of rolling element bearings is surveyed. Emphasis is on the critical design aspects related to speed, temperature, and ambient pressure environment. Types of lubrication including grease, jets, mist, wick, and through the race are discussed. The historical development, present state of technology, and the future problems of rolling element bearing lubrication are discussed.

Parker, R. J.↗

Capillary device refilling

An analytical and experimental study was conducted dealing with refilling start baskets (capillary devices) with settled fluid. A computer program was written to include dynamic pressure, screen wicking, multiple-screen barriers, standpipe screens, variable vehicle mass for computing vehicle acceleration, and calculation of tank outflow rate and vapor pullthrough height. An experimental apparatus was fabricated and tested to provide data for correlation with the analytical model; the test program was conducted in normal gravity using a scale-model capillary device and ethanol as the test fluid. The test data correlated with the analytical model; the model is a versatile and apparently accurate tool for predicting start basket refilling under actual mission conditions.

Blatt, M. H.↗

Urine collection device

A urine collection device for females is described. It is comprised of a collection element defining a urine collection chamber and an inlet opening into the chamber and is adapted to be disposed in surrounding relation to the urethral opening of the user. A drainage conduit is connected to the collection element in communication with the chamber whereby the chamber and conduit together comprise a urine flow pathway for carrying urine generally away from the inlet. A first body of wicking material is mounted adjacent the collection element and extends at least partially into the flow pathway. The device preferably also comprise a vaginal insert element including a seal portion for preventing the entry of urine into the vagina.

Michaud, R. B.↗