Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Rapid X-ray and optical variability in the X-ray selected BL Lacertae object IE 1402.3 + 0416

Results from X-ray and optical observations of the X-ray-discovered BL Lac object 1E 1402.3 + 0416 are presented, where the X-ray measurements were carried out with the Channel Multiplier Array (CMA) and Medium Energy experiment (ME) detectors on board Exosat. These measurements revealed an intensity decrease by a factor of two on a time scale of a few hours. At maximum flux, the source was significantly greater than at the time of the Einstein Image Proportional Counter (IPC) discovery observation. The 2-6 keV X-ray spectrum was determined by the ME experiment, and IPC, HRI, and CMA data were subsequently compared. The source varied over the years by a factor of five; its brightest state was within the last three years. It is noted that a redshift greater than 0.2 would require that anisotropic emission mechanisms be invoked.

Giommi, P.↗

A comparison of the X-ray properties of X Persei and Gamma Cassiopeiae

The greater than 0.0001 solar mass/year loss rates required to power X-ray sources, if associated compact objects are white dwarfs, are many orders of magnitude greater than even the highest estimates for the main sequence Be stars Chi Per and Gamma Cas, confirming that the compact objects in these systems are neutron stars. While observed mass loss rates are of the order of that required to power the X-ray emission from a neutron star, X-ray measurements have established rates at least an order of magnitude above UV estimates, supporting earlier suggestions of an inclination dependence in the mass loss from rapidly rotating main sequence OB stars which results in mass loss rates in the orbital plane that are at least one order of magnitude higher, or terminal velocities that are at least a factor of 2.0 lower, than is indicated by UV measurements.

White, N. E.↗

Development of X-Ray Optics for the International X-Ray Observatory (IXO)

The International X-ray Observatory requires mirror assemblies with unprecedented characteristics that cannot be provided by existing optical technologies. In the past several years, the project has supported a vigorous mirror technology development program. This program includes the fabrication of lightweight mirror segments by slumping commercially available thin glass sheets, the support and mounting of these thin mirror segments for accurate metrology, the mounting and attachment of these mirror segments for the purpose of X-ray tests, and development of methods for aligning and integrating these mirror segments into mirror assemblies. This paper describes our efforts and developments in these areas.

Zhang, William W.↗

Eta Carinae: X-ray Line Variations during the 2003 X-ray Minimum, and the Orbit Orientation

The future evolution of Eta Carinae will be as a supernova (or hypernova) and black hole. The evolution is highly contingent on mass and angular momentum changes and instabilities. The presence of a companion can serve to trigger instabilities and provide pathways for mass and angular momentum exchange loss. X-rays can be used a a key diagnostic tool: x-ray temperatures trace pre-shock wind velocities, periodic x-ray variability traces the orbit, and x-ray line variations traces the flow and orientation of shocked gas. This brief presentation highlights x-ray line variations from the HETG and presents a model of the colliding wind flow.

Corcoran, M. F.↗

High Resolution Spectroscopy of X-ray Quasars: Searching for the X-ray Absorption from the Warm-Hot Intergalactic Medium

We present a survey of six low to moderate redshift quasars with Chandra and XMM-Newton. The primary goal is to search for the narrow X-ray absorption lines produced by highly ionized metals in the Warm-Hot Intergalactic Medium. All the X-ray spectra can be well fitted by a power law with neutral hydrogen absorption. Only one feature is detected at above 3-sigma level in all the spectra, which is consistent with statistic fluctuation. We discuss the implications in our understanding of the baryon content of the universe. We also discuss the implication of the non-detection of the local (z approx. 0) X-ray absorption.

Fang, Taotao↗

X-ray Properties of an Unbiased Hard X-ray Detected Sample of AGN

The SWIFT gamma ray observatory's Burst Alert Telescope (BAT) has detected a sample of active galactic nuclei (AGN) based solely on their hard X-ray flux (14-195keV). In this paper, we present for the first time XMM-Newton X-ray spectra for 22 BAT AGXs with no previously analyzed X-ray spectra. If our sources are a representative sample of the BAT AGN, as we claim, our results present for the first time global X-ray properties of an unbiased towards absorption (n(sub H) < 3 x 10(exp 25)/sq cm), local (< z >= 0.03), AGN sample. We find 9/22 low absorption (n(sub H) < 10(exp 23)/sq cm), simple power law model sources, where 4 of these sources have a statistically significant soft component. Among these sources, we find the presence of a warm absorber statistically significant for only one Seyfert 1 source, contrasting with the ASCA results of Reynolds (1997) and George et al. (1998), who find signatures of warm absorption in half or more of their Seyfert 1 samples at similar redshifts. Additionally, the remaining sources (13122) have more complex spectra, well-fit by an absorbed power law at E > 2.0 keV. Five of the complex sources (NGC 612, ESO 362-G018, MRK 417, ESO 506-G027, and NGC 6860) are classified as Compton-thick candidates. Further, we find four more sources (SWIFT J0641.3+3257, SWIFT J0911.2+4533, SWIFT J1200.8+0650, and NGC 4992) with properties consistent with the hidden/buried AGN reported by Ueda et al. (2007). Finally, we include a comparison of the XMM EPIC spectra with available SWIFT X-ray Telescope (XRT) observations. From these comparisons, we find 6/16 sources with varying column densities, 6/16 sources with varying power law indices, and 13/16 sources with varying fluxes, over periods of hours to months. Flux and power law index are correlated for objects where both parameters vary.

Winter, Lisa M.↗

Reflectivity Around the Gold L-Edges of X-Ray Reflector of the Soft X-Ray Telescope Onboard ASTRO-H

We report the atomic scattering factor in the 11.215.4 keV for the ASTRO-H Soft X-ray Telescope (SXT) obtained in the ground based measurements. The large effective area of the SXT covers above 10 keV. In fact, the flight data show the spectra of the celestical objects in the hard X-ray band. In order to model the area, the reflectivity measurements in the 11.2-15.4 keV band with the energy pitch of 0.4-0.7 eV were made in the synchrotron beamline Spring-8 BL01B1. We obtained atomic scattering factors f1 and f2 by the curve fitting to the reflectivities of our witness sample. The edges associated with the golds L-I, II, and III transitions are identified, of which the depths are found to be roughly 60 percent shallower than those expected from the Henke's atomic scattering factor.

X-rays↗

Simultaneous ambient pressure x-ray photoelectron spectroscopy and grazing incidence x-ray scattering in gas environments

We have developed an experimental system to simultaneously measure surface structure, morphology, composition, chemical state, and chemical activity for samples in gas phase environments. This is accomplished by simultaneously measuring x-ray photoelectron spectroscopy (XPS) and grazing incidence x-ray scattering in gas pressures as high as the multi-Torr regime while also recording mass spectrometry. Scattering patterns reflect near-surface sample structures from the nano-scale to the meso-scale, and the grazing incidence geometry provides tunable depth sensitivity of structural measurements. Scattered x rays are detected across a broad range of angles using a newly designed pivoting-UHV-manipulator for detector positioning. At the same time, XPS and mass spectrometry can be measured, all from the same sample spot and under ambient conditions. To demonstrate the capabilities of this system, we measured the chemical state, composition, and structure of Ag-behenate on a Si(001) wafer in vacuum and in O 2 atmosphere at various temperatures. These simultaneous structural, chemical, and gas phase product probes enable detailed insights into the interplay between the structure and chemical state for samples in gas phase environments. The compact size of our pivoting-UHV-manipulator makes it possible to retrofit this technique into existing spectroscopic instruments installed at synchrotron beamlines. Because many synchrotron facilities are planning or undergoing upgrades to diffraction limited storage rings with transversely coherent beams, a newly emerging set of coherent x-ray scattering experiments can greatly benefit from the concepts we present here.

47 OTHER INSTRUMENTATION↗

Hard X-Ray Lightcurves of High Mass X-Ray Binaries

Using the 7.2 years of continuous data now available from the Burst And Transient Source Experiment (BATSE) aboard CGRO, we have measured orbital periods and produced folded lightcurves for 8 High Mass X-ray Binaries (HMXB). Given the length of the datasets, our determinations are based on many more binary orbits than previous investigations. Thus our source detections have high statistical significance and we are able to follow long-term trends in X-ray output. In particular we focus on two systems: A0538-668 and EXO2030+375 both HMXBs exhibiting Type I outbursts. Recent work on A0538-668 (Alcock et al 1999) reported a 16.65d optical variability due to the orbital period, but only seen during minima of a longer-term variability at 421d. We searched for this signal in the BATSE dataset using an ephemeris derived from Alcock et al ( 1999) & Skinner ( 1982). We found no evidence for such modulation and place an upper limit of 3.0 x 10(exp -3) photon/sq cm.s in the 20-70 keV BATSE energy band , based upon statistical modelling of the signal. EXO2030+375 has exhibited an X-ray active epoch, followed by a quiescent period lasting 2.5yr and since April 1996 has exhibited renewed activity. Previous observations (Reig et a 1998) using RXTE ASM data indicate secondary outbursts occur at apastron passage during the current epoch, but not in the former. We present a lightcurve for the earlier epoch showing convincing evidence for such apastron outbursts. We find apastron outbursts in 3 sources, all having orbital periods greater than 41d. No such signal is conclusively detected in the more rapidly orbiting systems studied.

Laycock, S.↗

ANS spectrophotometry - The bright X-ray binaries Hercules X-1 /HZ Herculis/ and Cygnus X-1 /HDE 226868/

Complete ultraviolet light curves for HZ Her immediately after a well-defined X-ray turn-on in 1975 are obtained. The features of the curve are found to correspond well with features seen in the optical. The absolute level of emission at maximum light at 1550 A is in good agreement with the calculations of the X-ray reflection effect of Milgrom and Salpeter (1975). It is found that at 1550 A approximately 20% of the light at maximum comes from the accretion disk. Similar observations of Cyg X-1 make it possible to determine the degree of reddening, equivalent to E(B-V) = 0.95 + or - 0.07, from the strength of the 2200 A interstellar absorption feature. The distance inferred from this amount of reddening requires that the optical star be luminous and, therefore, massive. Observations obtained during the May 1975 X-ray transition show ultraviolet excess when compared with the data obtained six months later.

Wu, C.-C.↗

Modifications of the X-ray source and monitor at the X-ray Calibration Facility

In order to test the instruments aboard the Advanced X-ray Astrophysics Facility (AXAF) some modifications will need to be made in the X-ray Calibration Facility at Marshall. Several of these modifications involve the X-ray source and the monitor. The source was redesigned to increase the spectral purity of the beam and decrease its polarization by minimizing the number of bremsstrahlung photons in the beam. This was accomplished by utilizing an annular electron gun which allowed the beam to take off antiparallel to the direction at which electrons are incident on the anode. Two other features of the source are the conical anode which decreases the effective spot size and a rotatable anode and filter wheel which allow the operator to change targets without breaking vacuum. The monitor is an important part of the facility because it is used to determine the X-ray flux at the target. A commercially available solid-state detector, Si(Li), should be used along with appropriate proportional counters for monitoring. This detector will be particularly useful when energy or wavelength dispersive instruments are tested because of its good resolution.

Newbolt, W. Barlow↗

The Effect of Intensity Fluctuations on Sequential X-ray Photon Correlation Spectroscopy at the X-ray Free Electron Laser Facilities

How materials evolve at thermal equilibrium and under external excitations at small length and time scales is crucial to the understanding and control of material properties. X-ray photon correlation spectroscopy (XPCS) at X-ray free electron laser (XFEL) facilities can in principle capture dynamics of materials that are substantially faster than a millisecond. However, the analysis and interpretation of XPCS data is hindered by the strongly fluctuating X-ray intensity from XFELs. Here we examine the impact of pulse-to-pulse intensity fluctuations on sequential XPCS analysis. We show that the conventional XPCS analysis can still faithfully capture the characteristic time scales, but with substantial decrease in the signal-to-noise ratio of the g2 function and increase in the uncertainties of the extracted time constants. We also demonstrate protocols for improving the signal-to-noise ratio and reducing the uncertainties.

36 MATERIALS SCIENCE↗

Temperature-dependent x-ray fluorescent response from thermographic phosphors under x-ray excitation

Phosphor thermometry has been successfully applied within several challenging environments. Typically, the thermographic phosphors are excited by an ultraviolet light source, and the temperature-dependent spectral or temporal response is measured. However, this is challenging or impossible in optically thick environments. In addition, emission from other sources (e.g., a flame) may interfere with the optical phosphor emission. Furthermore, a temperature dependent x-ray excitation/emission could alleviate these issues as x-rays could penetrate obscurants with no interference from flame luminosity. In addition, x-ray emission could allow for thermometry within solids while simultaneously x-ray imaging the structural evolution. In this study, select thermographic phosphors were excited via x-ray radiation, and their x-ray emission characteristics were measured at various temperatures. Several of the phosphors showed varying levels of temperature dependence with the strongest sensitivity occurring for YAG:Dy and ZnGa 2 O 4 :Mn. This approach opens a path for less intrusive temperature measurements, particularly in optically opaque multiphase and solid phase combustion environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implications of the high-state iron-line feature and soft X-ray emission of Hercules X-1

The interpretation that the soft X-ray emission of Her X-1 is due to reprocessing of the primary hard X-rays intercepted by a plasma layer in the Alfven surface imposes quite a stringent - but not an unreasonable - constraint on its parameters. By using the Alfven shell parameters constrained by this interpretation, the degree of ionization of the Alfven shell is calculated. Because the flux of hard X-ray from the neutron star is greatly attenuated inside the Alfven shell, except for a skin depth from its inner surface, the degree of ionization is determined by photoionization due to soft X-rays produced within the Alfven shell. On one hand, the large soft X-ray luminosity, which is about the same as the hard X-ray luminosity, indicates that a substantial fraction of primary hard X-rays is absorbed by the Alfven shell. On the other hand, the fact that the hard X-ray spectrum of Her X-1 observed during the high state shows neither a significant absorption feature down to about 3 keV nor an iron K-absorption dip tells us that the hard X-rays observed at the earth are mostly not reprocessed. This apparent conflict is resolved if the Alfven shell is clumpy (i.e., made of streams or blobs). The observed iron-line feature around 6.5 keV (E.W. about 300 keV) is explained by fluorescent iron K photons produced as a by-product of reprocessing of the hard X-rays by the Alfven shell; for this a large enhancement of the iron abundance with respect to the solar value is not required.

Bai, T.↗

Spectroscopic analysis of solar and cosmic X-ray spectra. I - The nature of cosmic X-ray spectra and proposed analytical techniques

X-ray spectroscopic techniques developed in the study of the temperature and density structure of the solar corona are reviewed as introduction to a discussion of the modifications in these techniques which will be required for the study of cosmic X-ray sources. The structure of the interstellar medium - the presence of interstellar grains, the presence of molecules, the ionization structure - are considered in relation to the X-ray opacity of the interstellar medium. The expected spectral structure of individual cosmic X-ray sources is reviewed with emphasis on galactic supernova remnants and galactic binary X-ray sources.

Walker, A. B. C., Jr.↗

Multiscale in-situ characterization of static recrystallization using dark-field X-ray microscopy and high-resolution X-ray diffraction

Abstract Dark-field X-ray microscopy (DFXM) is a high-resolution, X-ray-based diffraction microstructure imaging technique that uses an objective lens aligned with the diffracted beam to magnify a single Bragg reflection. DFXM can be used to spatially resolve local variations in elastic strain and orientation inside embedded crystals with high spatial (~ 60 nm) and angular (~ 0.001°) resolution. However, as with many high-resolution imaging techniques, there is a trade-off between resolution and field of view, and it is often desirable to enrich DFXM observations by combining it with a larger field-of-view technique. Here, we combine DFXM with high-resolution X-ray diffraction (HR-XRD) applied to an in-situ investigation of static recrystallization in an 80% hot-compressed Mg–3.2Zn–0.1Ca wt.% (ZX30) alloy. Using HR-XRD, we track the relative grain volume of > 8000 sub-surface grains during annealing in situ. Then, at several points during the annealing process, we “zoom in” to individual grains using DFXM. This combination of HR-XRD and DFXM enables multiscale characterization, used here to study why particular grains grow to consume a large volume fraction of the annealed microstructure. This technique pairing is particularly useful for small and/or highly deformed grains that are often difficult to resolve using more standard diffraction microstructure imaging techniques.

36 MATERIALS SCIENCE↗

Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using a cylindrical-harmonics expansion

Inertial confinement fusion capsule implosions produce neutron, gamma-ray, and x-ray emission, which are recorded by a variety of detectors, both time integrated and time resolved, to determine the performance of the implosion. Further, two-dimensional emission images from multiple directions can now be combined to infer three-dimensional structures in the implosion, such as the distribution of thermonuclear fuel density, carbon ablator, and impurities. Because of the cost and complexity of the imaging systems, however, only a few measurements can be made, so reconstructions of the source must be made from a limited number of views. Here, a cylindrical-harmonics decomposition technique to reconstruct the three-dimensional object from two views in the same symmetry plane is presented. In the limit of zero order, this method recovers the Abel inversion method. The detailed algorithms used for this characterization and the resulting reconstructed neutron source from an experiment collected at the National Ignition Facility are presented.

47 OTHER INSTRUMENTATION↗