At least 217 records · Page 12

Results for the first quarter 2012 tank 50 wac slurry sample: chemical and radionuclide contaminant results

This report details the chemical and radionuclide contaminant results for the characterization of the 2012 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this memorandum: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section; (2) The reported detection limit for {sup 94}Nb is above the requested limit from Reference 2 but below the estimated limit in Reference 3; (3) {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. however, they are below the limits established in Reference 3; (4) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC; (5) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC; (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples, the values reported in this report are the concentrations in the sub-sample as detected by the instrument; however, the results may not accurately represent the concentrations of the analytes in Tank 50; and (7) The low insoluble solids content increases the measurement uncertainty for insoluble species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RESULTS FOR THE FIRST QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2010 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (3) The reported detection limits for {sup 59}Ni and {sup 94}Nb are above the requested limits from Reference 4. However, they are each below the limits established in Reference 6. (4) The reported detection limit for isopropanol is greater than the requested limit from Table 4 of the WAC. (5) The reported detection limits for 247Cm and 249Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 6. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RESULTS FOR THE FIRST QUARTER 2009 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2009 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the chemical and radioactive contaminants were all less than their respective WAC Targets or Limits except for Am-242m. (2) The radionuclide Am-242m was not detected; however, its detection limit is above the WAC Target given in Attachment 8.4. The higher detection limit was expected based on current analytical capabilities as stated in the Task Technical and Quality Assurance Plan (TTQAP). (3) The reported detection limit of isopropanol was lower than its WAC Limit for accident analysis but higher than its WAC concentration given in Table 4 for vault flammability. The higher detection limit was expected based on current analytical capabilities and is documented in the Task Technical and Quality Assurance Plan (TTQAP). (4) The reported detection limit for Isopar L is lower than its WAC limit for accident analysis in Appendix 8.1 but higher than its WAC concentration given in Table 3 in reference to vault flammability. The higher detection limit was expected based on current analytical capabilities as stated in the Task Technical and Quality Assurance Plan (TTQAP). (5) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of these analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RESULTS FOR THE FIRST QUARTER 2011 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2011 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section; (2) The reported detection limit for {sup 59}Ni is above both the requested limits from Reference 2 and the established limits in Reference 3; (3) The reported detection limit for {sup 94}Nb is above the requested limit from Reference 2; however, it is below the established limits in Reference 3. This is a change from previously reported results; (4) The reported concentration of {sup 242m}Am is above the target in Listed in Attachment 8.4 of the Saltstone WAC. This is a change from the previously reported results; (5) {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. However, they are below the limits established in Reference 3; (6) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC; (7) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC; and (8) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the instrument; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report for Batch Leach Analyses on Sediments at 100-HR-3 Operable Unit, Boreholes C7620, C7621, C7622, C7623, C7626, C7627, C7628, C7629, C7630, and C7866

This is a revision to a previously released report. This revision contains additional analytical results for the sample with HEIS number B2H4X7. Between November 4, 2010 and October 26, 2011 sediment samples were received from 100-HR-3 Operable Unit for geochemical studies. The analyses for this project were performed at the 331 building located in the 300 Area of the Hanford Site. The analyses were performed according to Pacific Northwest National Laboratory (PNNL) approved procedures and/or nationally recognized test procedures. The data sets include the sample identification numbers, analytical results, estimated quantification limits (EQL), and quality control data. The preparatory and analytical quality control requirements, calibration requirements, acceptance criteria, and failure actions are defined in the on-line QA plan 'Conducting Analytical Work in Support of Regulatory Programs' (CAW). This QA plan implements the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD) for PNNL. Samples were received with a chain of custody (COC) and were analyzed according to the sample identification numbers supplied by the client. All Samples were refrigerated upon receipt until prepared for analysis. All samples were received with custody seals intact unless noted in the Case Narrative. Holding time is defined as the time from sample preparation to the time of analyses. The prescribed holding times were met for all analytes unless noted in the Case Narrative. All reported analytical results meet the requirements of the CAW or client specified SOW unless noted in the case narrative. Due to the requirements of the statement of work and sampling events in the field, the 28 day and the 48 hr requirements cannot be met. The statement of work requires samples to be selected at the completion of the borehole. It is not always possible to complete a borehole and have the samples shipped to the laboratory within the hold time requirements. Duplicate RPD for Uranium 238 (38.9%) was above the acceptance limit (35) in 1E05003-DUP1 for ICPMS-Tc-U-WE The sample result is less than 10 times the detection limits. Duplicate recoveries are not applicable to this analyte. Duplicate RPD for Silver 107 (68.2%) was above the acceptance limit (35) in 2C06004-DUP1 for ICPMS-RCRA-AE The sample result is less than 10 times the detection limits. Duplicate recoveries are not applicable to this analyte. Matrix Spike Recovery for Chromium, Hexavalent (48.8%) was outside acceptance limits (75-125) in 1E23001-MS1 for Hexavalent Chromium/Soil. Potential Matrix interference. Sample results associated with this batch are below the EQL. There should be no impact to the data as reported. Matrix Spike Recovery for Chromium, Hexavalent (50.2%) was outside acceptance limits (75-125) in 2B22010-MS1 for Hexavalent Chromium/Soil. Potential Matrix interference. Sample results associated with this batch are below the EQL. There should be no impact to the data as reported.

54 ENVIRONMENTAL SCIENCES↗

RESULTS FOR THE THIRD QUARTER 2009 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2009 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. Recently, a review of the radionuclide inventory in Saltstone Vaults 1 and 4 identified several additional radionuclides, not currently in the WAC, which require quantification ({sup 40}K, {sup 108m}Ag, {sup 133}Ba, {sup 207}Bi, {sup 227}Ac, {sup 228}Ra, {sup 228}Th, {sup 231}Pa, {sup 247}Cm, {sup 249}Cf, {sup 251}Cf). In addition, several of the radionuclides previously reported with minimum detection limits below the requirements listed in the WAC required analysis with reduced detection limits to support future inventory reporting requirements ({sup 22}Na, {sup 26}Al, {sup 59}Ni, {sup 94}Nb, {sup 106}Ru, {sup 144}Ce, {sup 152}Eu, {sup 155}Eu, {sup 226}Ra). This added scope was formally requested in a revision to the standing Technical Task Request for CY2009 Saltstone support and is further discussed in several supporting documents. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants are less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limits for {sup 59}Ni, {sup 94}Nb, {sup 247}Cm, and {sup 249}Cf are above the limits requested by LWO; however, they are below the achievable limits established by Analytical Development (AD). (3) The reported detection limit of isopropanol is lower than its WAC Limit for accident analysis in Appendix 8.1, but higher than its WAC concentration given in Table 4 for vault flammability. The higher detection limit is expected based on current analytical capabilities and is documented in the Task Technical and Quality Assurance Plan (TTQAP). (4) The reported detection limit for Isopar L is lower than its WAC limit for accident analysis in Appendix 8.1 but higher than its WAC concentration given in Table 3 in reference to vault flammability. (5) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of these analytes in the Tank 50 sample received by SRNL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metals Analysis of Biodiesel Blends

The goal of this study was to compare metals analysis methods for biodiesel blends. Thirty-five B20 samples were collected from public stations and private fleets throughout the United States. All samples were analyzed for blend content and critical properties under the ASTM D7467 specification. Although not part of the specification, metals content, specifically Na, K, Ca, Mg, and P, is becoming an increasingly larger concern for industry. This study compared the metals content of the B20 samples using inductively coupled plasma atomic emission spectroscopy (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS), and microwave plasma atomic emission spectroscopy (MP-AES) methods. All three techniques showed improvements over the current detection limits of 1 ppm for Na, K, Ca, and Mg, and 5 ppm for P. Some differences were found between methods, but agreement was generally acceptable at the very low levels present in these samples. The MP-AES technique showed good promise for future development for this type of analysis.

33 ADVANCED PROPULSION SYSTEMS↗

Fuel property evaluation of unique fatty acid methyl esters containing β-hydroxy esters from engineered microorganisms

Unique fatty acid methyl esters (FAME) containing ..beta..-hydroxy esters were produced using an engineered microorganism by glucose fermentation. This study investigated the properties of the unique FAME mixture both neat and in blends with conventional diesel, as well as properties of ..beta..-hydroxy esters. The unique FAME blend contained relatively shorter-chain FAME (average fatty acid chain carbon number 14.6) with 58 % monounsaturated fatty acids and 9 % saturated and monounsaturated ..beta..-hydroxy acid chains. The unique FAME had significantly lower distillation T90 (321 °C versus 352 °C) and higher cetane number (56.7 versus 52) compared to soy biodiesel. Cloud points were within method repeatability. Unexpectedly (because of the lack of methylene-interrupted double bonds), the unique FAME had low oxidation stability (1.5 h) as determined by Rancimat induction period. Stability could be improved through addition of commonly used antioxidants. We speculate that monounsaturated ..beta..-hydroxy FAME may be the source of this instability. Blends with conventional diesel up to 50 vol% showed similar kinematic viscosity (within method repeatability) as blends of conventional FAME. The unique FAME had no effect on distillation T90 even at the 80% blend level. A 30 vol% blend into conventional diesel had a Rancimat induction period of only 2 h, very nearly the same as the neat unique FAME sample. The addition of antioxidants produced blends of acceptable stability. Based on an assessment of the properties of individual ..beta..-hydroxy FAME molecules, they have higher boiling point, higher cloud point, lower cetane number, and potentially lower storage stability than analogous FAME not having the ..beta..-hydroxy group. Removing them from the fuel product in the production process may result in a biodiesel product with superior properties to what is on the market today.

09 BIOMASS FUELS↗

Property-Graded Stainless Steel 316L by Selective Laser Melting: Characterization & Design

Abstract The purpose of this research work is to characterize and inform the design of (mechanical) property-graded bulk structures made from a single metallic alloy via a laser powder bed fusion (LPBF) process, with an end goal of creating repeatable/reproducible functionally-graded additively manufactured (FGAM) parts. This paper specifically investigates the manufacture of stainless steel (SS) 316L structures via a pulsed selective laser melting (SLM) process, and the underlying causes of property variations (within a functionally-acceptable range) through various material characterization techniques. For this, a design of experiments spanning the volumetric energy density (VED) based process parameter design space was utilized to investigate the range of functionally-acceptable physical/mechanical properties achievable in SS 316L. Five sample conditions (made via different process parameter combinations) were down-selected for in-depth microstructure analysis and mechanical/physical property characterization; these were suitably selected to impart a wide and controllable property range (209–318 HV hardness, 90–99.9% relative density, and 154–211 GPa modulus). It was observed that property variations resulted from combinations of porosity types/amounts, martensitic phase fractions, and grain sizes. Based on these findings, property-graded standard test specimens were designed and manufactured for further investigation—tensile specimens having a monotonic hardness change along its gauge length, four-point bending specimens with varying elastic moduli as a function of the distance from the neutral axis, and Moore’s rotating beam fatigue specimens with moduli variations based on the distance from the center. Altogether, this work lays the foundation for understanding and designing the local and global mechanical performance of FGAM bulk structures.

Engineering↗

Destructive testings: dry drilling operations with TruPro system to collect samples in a powder form, from two hulls containing immobilized wastes in a hydraulic binder

The TruPro{sup R} process enables to collect a significant number of samples to characterize radiological materials. This innovative and alternative technique is experimented for the ANDRA quality-control inspection of cemented packages. It proves to be quicker and more prolific than the current methodology. Using classical statistics and geo-statistics approaches, the physical and radiological characteristics of two hulls containing immobilized wastes (sludges or concentrates) in a hydraulic binder are assessed in this paper. The waste homogeneity is also evaluated in comparison to ANDRA criterion. Sensibility to sample size (support effect), presence of extreme values, acceptable deviation rate and minimum number of data are discussed. The final objectives are to check the homogeneity of the two characterized radwaste packages and also to validate and reinforce this alternative characterization methodology. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Third Quarter 2012 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2012 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results For The Fourth Quarter 2012 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2012 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC).Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results For The First Quarter 2013 Tank 50 WAC Slurry Sample: Chemical And Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2013 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Second Quarter 2013 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Second Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by Saltstone Facility Engineering (SFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results For The Third Quarter 2013 Tank 50 WAC Slurry Sample

This report details the chemical and radionuclide contaminant results for the characterization of the 2013 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the second quarter 2014 tank 50 WAC slurry sample chemical and radionuclide contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2014 Second Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Third Quarter 2014 Tank 50 WAC slurry sample: Chemical and radionuclide contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2014 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. 1 Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct Feed High-Level Waste APPS Model Glass Testing (DFHLW APPS) Matrix, Phase 2

This report summarizes the data collected during the batching and melting of a second matrix of Direct Feed High-Level Waste (DFHLW) glasses generated using the preliminary enhanced waste glass models (EWG2.5) and the Britton and Anderson (2024) preliminary DFHLW feed vector. The purpose of these glasses is two-fold: 1. Validate EWG2.5 glass calculations being used in the Aspen Process Performance Simulation (APPS) model. 2. Evaluate and ultimately improve the glass property models and formulation methods used for design of DFHLW glasses as part of an iterative process of data collection and model refinement. Some of the 16 APPS2 glasses tested did not satisfy all target property constraints due to the limited data on DFHLW glass supporting the EWG2.5 models. • One glass, APPS2-10, formed nepheline on canister centerline cooling (CCC) heat-treatment and failed the product consistency test (PCT) response limits. This glass also had high B and Cr release rates for the toxicity characteristic leaching procedure (TCLP). All other glasses were found to satisfy the PCT and TCLP constraints for both quenched and CCC samples. • One glass, APPS2-08, had higher than acceptable viscosity due to magnetite crystallization. • One glass, APPS2-09, formed greater than 2 vol% crystals at 950 °C. As the glass design criterion was that the temperature at 2 vol% crystal (T 2% ) be less than 950 °C, only one glass failed the criteria. However, this criterion is being reevaluated. Four additional glasses formed crystal fractions between 1 and 2 vol% at 950 °C (APPS2-03, -08, -12, and -14). • Four glasses – APPS2-01, -02, -04, and -16 – failed the Monofrax K-3 refractory neck corrosion (k neck ) design limit of 0.04 in. at 1208 °C for 6 d. This is another criterion being reevaluated. Four additional glasses (APPS2-05, -06, -11, and -13) exhibited 0.025 = k neck = 0.04 in. • All 16 glasses passed the sulfur solubility and TCLP constraints. The measured property values were compared to predicted values using EWG2.5 and a selection of other existing models. A few models (e.g., electrical conductivity, TCLP) were found to be adequate for designing DFHLW glasses in the near future, while others require refits or offsets. It is recommended that new property models be developed for EWG3.0, as a large amount of DFHLW glass property data (> 14 × existing data) is expected to be collected in the compositional spaces where no data was previously available. To enable near-term calculations and formulations for designing DFHLW glasses and processing rate estimations, a formulation algorithm with minor modifications will be developed, EWG2.6.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗