Search NASA⌕ Search

SEARCH · Search NASA

Results for “accurate quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Uncertainty quantification for molecular property predictions with graph neural architecture search

Graph Neural Networks (GNNs) have emerged as a prominent class of data-driven methods for molecular property prediction. However, a key limitation of typical GNN models is their inability to quantify uncertainties in the predictions. This capability is crucial for ensuring the trustworthy use and deployment of models in downstream tasks. To that end, we introduce AutoGNNUQ, an automated uncertainty quantification (UQ) approach for molecular property prediction. AutoGNNUQ leverages architecture search to generate an ensemble of high-performing GNNs, enabling the estimation of predictive uncertainties. Our approach employs variance decomposition to separate data (aleatoric) and model (epistemic) uncertainties, providing valuable insights for reducing them. In our computational experiments, we demonstrate that AutoGNNUQ outperforms existing UQ methods in terms of both prediction accuracy and UQ performance on multiple benchmark datasets, and generalizes well to out-of-distribution datasets. Additionally, we utilize t-SNE visualization to explore correlations between molecular features and uncertainty, offering insight for dataset improvement. AutoGNNUQ has broad applicability in domains such as drug discovery and materials science, where accurate uncertainty quantification is crucial for decision-making.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unorthodox parallelization for Bayesian quantum state estimation

Quantum state tomography (QST) allows for the reconstruction of quantum states through measurements and some inference technique under the assumption of repeated state preparations. Bayesian inference provides a promising platform to achieve both efficient QST and accurate uncertainty quantification, yet is generally plagued by the computational limitations associated with long Markov chains. In this work, we present a novel Bayesian QST approach that leverages modern distributed parallel computer architectures to efficiently sample a D-dimensional Hilbert space. Using a parallelized preconditioned Crank–Nicholson Metropolis–Hastings algorithm, we demonstrate our approach on simulated data and experimental results from IBM Quantum systems up to four qubits, showing significant speedups through parallelization. Although highly unorthodox in pooling independent Markov chains, our method proves remarkably practical, with validation ex post facto via diagnostics like the intrachain autocorrelation time. We conclude by discussing scalability to higher-dimensional systems, offering a path toward efficient and accurate Bayesian characterization of large quantum systems.

Bayesian inference↗

Multifidelity Uncertainty Quantification of a Commercial Supersonic Transport

The objective of this work was to develop a multifidelity uncertainty quantification approach for efficient analysis of a commercial supersonic transport concept. An approach based on point-collocation, non-intrusive polynomial chaos was formulated in which a low-fidelity model could be corrected using multiple higher-fidelity models. The formulation and methodology also allows for the addition of uncertainty sources not present in the lower fidelity models. To demonstrate the applicability and potential computational savings of the multifidelity polynomial chaos approach, two model problems were explored. The first was a supersonic airfoil with three levels of modeling fidelity, each capturing a gradual increase in modeling of the underlying flow physics. As much as 50% computational cost reduction was observed using the mutlifidelity approach, while predicting nearly the same amount of uncertainty in drag. The second problem was a commercial supersonic transport. This model had three levels of fidelity that included two different modeling approaches and the addition of physics between the fidelity levels. Results of this analysis yielded nearly a 70% computational savings to predict a comparable amount of uncertainty in ground noise. Both problems illustrate the applicability and significant computational savings of the multifidelity method for efficient and accurate uncertainty quantification.

Thomas K. West IV↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Cell design for laser-induced breakdown spectroscopy measurements on reactive gas samples

Uranium hexafluoride (UF 6 ) is the primary material used for the enrichment of uranium in the production of light water nuclear reactor fuels worldwide. Accurate, rapid quantification of uranium isotopic composition in nuclear materials is required for safeguards programs and nonproliferation purposes. One potential technique for isotopic measurements in uranium species in the field is laser induced breakdown spectroscopy (LIBS). Safe and effective application of LIBS to UF 6 for enrichment measurements is uniquely challenging due to the chemical and physical properties of UF 6 , which necessitate specific handling procedures. The objective of this work is to design a cell for isotopic analysis of UF 6 that is (1) compatible with chemical and physical properties of UF 6 , (2) compatible with LIBS laser, and (3) portable-sized for nuclear safeguards applications. Along with cell design, initial testing of the cell for basic performance and chemical compatibility is performed. As designed and constructed, the portable gas cell was gas-tight, chemically compatible with UF 6 , and withstood long-duration laser exposure. In this work, the cell has proven capability for handling reactive gasses, such as UF 6 , with specification application to isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accounting for Population Variation in Targeted Proteomics

Individual proteomes typically differ from the reference human proteome at ~10,000 single amino acid variants. When viewed at the population scale, this individual variation results in a wide variety of protein sequences. In targeted proteomics experiments, such variability would confound accurate protein quantification. To facilitate researchers in identifying target peptides with high variability within the human population we have created the Population Variation plug-in for Skyline, which provides easy access to the polymorphisms stored in dbSNP. Given a set of peptides, the tool reports minor allele frequency for common polymorphisms. We highlight the importance of considering genetic variation by applying the tool to public datasets.

59 BASIC BIOLOGICAL SCIENCES↗

Systematic Benchmarking of Climate Models: Methodologies, Applications, and New Directions

As climate models become increasingly complex, there is a growing need to comprehensively and systematically assess model performance with respect to observations. Given the increasing number and diversity of climate model simulations in use, the community has moved beyond simple model intercomparison and toward developing methods capable of benchmarking a large number of simulations against a suite of climate metrics. Here, we present a detailed review of evaluation and benchmarking methods and approaches developed in the last decade, focusing primarily on scientific implications for Coupled Model Intercomparison Project (CMIP) simulations and CMIP6 results that contributed to the Intergovernmental Panel on Climate Change (IPCC) Sixth Assessment Report (AR6). Based on this review, we explain the resulting contemporary philosophy of model benchmarking, and provide clear distinctions and definitions of the terms model verification, process validation, evaluation, and benchmarking. While significant progress has been made in model development based on systematic evaluation and benchmarking efforts, some climate system biases still remain. The development of open‐source community software packages has played a fundamental role in identifying areas of significant model improvement and bias reduction. We review the key features of several software packages that have been commonly used over the past decade to evaluate and benchmark global and regional climate models. Additionally, we discuss best practices for the selection of evaluation and benchmarking metrics and for interpreting the obtained results, the importance of selecting suitable sources of reference data and accurate uncertainty quantification.

Environmental sciences↗

Deep energy-pressure regression for a thermodynamically consistent EOS model

Abstract In this paper, we aim to explore novel machine learning (ML) techniques to facilitate and accelerate the construction of universal equation-Of-State (EOS) models with a high accuracy while ensuring important thermodynamic consistency. When applying ML to fit a universal EOS model, there are two key requirements: (1) a high prediction accuracy to ensure precise estimation of relevant physics properties and (2) physical interpretability to support important physics-related downstream applications. We first identify a set of fundamental challenges from the accuracy perspective, including an extremely wide range of input/output space and highly sparse training data. We demonstrate that while a neural network (NN) model may fit the EOS data well, the black-box nature makes it difficult to provide physically interpretable results, leading to weak accountability of prediction results outside the training range and lack of guarantee to meet important thermodynamic consistency constraints. To this end, we propose a principled deep regression model that can be trained following a meta-learning style to predict the desired quantities with a high accuracy using scarce training data. We further introduce a uniquely designed kernel-based regularizer for accurate uncertainty quantification. An ensemble technique is leveraged to battle model overfitting with improved prediction stability. Auto-differentiation is conducted to verify that necessary thermodynamic consistency conditions are maintained. Our evaluation results show an excellent fit of the EOS table and the predicted values are ready to use for important physics-related tasks.

97 MATHEMATICS AND COMPUTING↗

Accuracy limitations for composition analysis by XPS using relative peak intensities: LiF as an example

Although precision in XPS can be excellent, allowing small changes to be easily observed, obtaining accurate absolute elemental composition of a solid material from relative peak intensities is generally much more problematical, involving many factors: background removal; differing analysis depths at different photoelectron kinetic energies; possible angular distribution effects; calibration of the instrument transmission function, and variations of the distribution of the photoelectron intensity between “main” peaks (those usually used for analysis) and associated substructure following the main peak, as a function of the chemical bonding of the elements concerned. The last item, coupled with the use of photoionization cross-sections and/or relative sensitivity factors, is the major subject of this paper, though it is necessary to consider the other items also, using LiF as a test case. The results show that the above issues, which are relevant to differing degrees in most XPS analyses, present significant challenges to highly accurate XPS quantification.

Brundle, Christopher R.↗

Evaluating the purity of a {sup 57}Co flood source by PET

Purpose: Flood sources of {sup 57}Co are commonly used for quality control of gamma cameras. Flood uniformity may be affected by the contaminants {sup 56}Co and {sup 58}Co, which emit higher energy photons. Although vendors specify a maximum combined {sup 56}Co and {sup 58}Co activity, a convenient test for flood source purity that is feasible in a clinical environment would be desirable. Methods: Both {sup 56}Co and {sup 58}Co emit positrons with branching 19.6% and 14.9%, respectively. As is known from {sup 90}Y imaging, a positron emission tomography (PET) scanner is capable of quantitatively imaging very weak positron emission in a high single-photon background. To evaluate this approach, two {sup 57}Co flood sources were scanned with a clinical PET/CT multiple times over a period of months. The {sup 56}Co and {sup 58}Co activity was clearly visible in the reconstructed PET images. Total impurity activity was quantified from the PET images after background subtraction of prompt gamma coincidences. Results: Time-of-flight PET reconstruction was highly beneficial for accurate image quantification. Repeated measurements of the positron-emitting impurities showed excellent agreement with an exponential decay model. For both flood sources studied, the fit parameters indicated a zero intercept and a decay half-life consistent with a mixture of {sup 56}Co and {sup 58}Co. The total impurity activity at the reference date was estimated to be 0.06% and 0.07% for the two sources, which was consistent with the vendor’s specification of <0.12%. Conclusions: The robustness of the repeated measurements and a thorough analysis of the detector corrections and physics suggest that the accuracy is acceptable and that the technique is feasible. Further work is needed to validate the accuracy of this technique with a calibrated high resolution gamma spectrometer as a gold standard, which was not available for this study, and for other PET detector models.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-08: Quantitative SPECT Imaging of Ra-223 in a Phantom

Purpose: Ra-223 therapy of prostate cancer bone metastases is being used to treat patients routinely. However, the absorbed dose distribution at the macroscopic and microscopic scales remains elusive, due to the inability to image the small activities injected. Accurate activity quantification through imaging is essential to calculate the absorbed dose in organs and sub-units in radiopharmaceutical therapy, enabling personalized absorbed dose-based treatment planning methodologies and more effective and optimal treatments. Methods: A 22 cm diameter by 20 cm long cylindrical phantom, containing a 3.52 cm diameter sphere, was used. A total of 2.01 MBq of Ra-223 was placed in the phantom with 177.6 kBq in the sphere. Images were acquired on a dual-head Siemens Symbia T16 gamma camera using three 20% full-width energy windows and centered at 84, 154, and 269 keV (120 projections, 360° rotation, 45 s per view). We have implemented reconstruction of Ra-223 SPECT projections using OS-EM (up to 20 iterations of 10 subsets) with compensation for attenuation using CT-based attenuation maps, collimator-detector response (CDR) (including septal penetration, scatter and Pb x-ray modeling), and scatter in the patient using the effective source scatter estimation (ESSE) method. The CDR functions and scatter kernels required for ESSE were computed using the SIMIND MC simulation code. All Ra-223 photon emissions as well as gamma rays from the daughters Rn-219 and Bi-211 were modeled. Results: The sensitivity of the camera in the three combined windows was 107.3 cps/MBq. The visual quality of the SPECT images was reasonably good and the activity in the sphere was 27% smaller than the true activity. This underestimation is likely due to partial volume effect. Conclusion: Absolute quantitative Ra-223 SPECT imaging is achievable with careful attention to compensate for image degrading factors and system calibration.

60 APPLIED LIFE SCIENCES↗

Enhancing characterization of organic nitrogen components in aerosols and droplets using high-resolution aerosol mass spectrometry

Abstract. This study aims to enhance the understanding and application of the Aerodyne high-resolution aerosol mass spectrometer (HR-AMS) for the comprehensive characterization of organic nitrogen (ON) compounds in aerosol particles and atmospheric droplets. To achieve this goal, we analyzed 75 N-containing organic compounds, representing a diverse range of ambient non-organonitrate ON (NOON) types, including amines, amides, amino acids, N heterocycles, protein, and humic acids. Our results show that NOON compounds can produce significant levels of NHx+ and NOx+ ion fragments, which are typically recognized as ions representative of inorganic nitrogen species. We also identified the presence of CH2N+ at m/z = 28.0187, an ion fragment rarely quantified in ambient datasets due to substantial interference from N2+. As a result, the utilization of an updated calibration factor of 0.79 is necessary for accurate NOON quantification via the HR-AMS. We also assessed the relative ionization efficiencies (RIEs) for various NOON species and found that the average RIE for NOON compounds (1.52 ± 0.58) aligns with the commonly used default value of 1.40 for organic aerosol. Moreover, through a careful examination of the HR-AMS mass spectral features of various NOON types, we propose fingerprint ion series that can aid the NOON speciation analysis. For instance, the presence of CnH2n+2N+ ions is closely linked with amines, with CH4N+ indicating primary amines, C2H6N+ suggesting secondary amines, and C3H8N+ representing tertiary amines. CnH2nNO+ ions (especially for n values of 1–4) are very likely derived from amides. The co-existence of three ions, C2H4NO2+, C2H3NO+, and CH4NO+, serves as an indicator for the presence of amino acids. Additionally, the presence of CxHyN2+ ions indicates the occurrence of 2N-heterocyclic compounds. Notably, an elevated abundance of NH4+ is a distinct signature for amines and amino acids, as inorganic ammonium salts produce only negligible amounts of NH4+ in the HR-AMS. Finally, we quantified the NOON contents in submicron particles (PM1) and fog water in Fresno, California, and PM1 in New York City (NYC). Our results revealed the substantial presence of amino compounds in both Fresno and NYC aerosols, whereas concurrently collected fog water in Fresno contained a broader range of NOON species, including N-containing aromatic heterocycle (e.g., imidazoles) and amides. These findings highlight the significant potential of employing the widespread HR-AMS measurements of ambient aerosols and droplets to enhance our understanding of the sources, transformation processes, and environmental impacts associated with NOON compounds in the atmosphere.

Ge, Xinlei (ORCID:0000000195316478)↗

Study of activation data of metal samples from LDEF-1 and Spacelab-2

Gamma-ray spectra obtained from samples flown aboard the Long Duration Exposure Facility have been analyzed to obtain the nuclear species produced in this material by the interaction of this material with protons and neutrons in this material by the interaction of this material with protons and neutrons encountered in its 69 month orbital flight as well as to quantify the specific activity (pCi/kg) of these nuclear species. This quantification requires accurate corrections of efficiency, self-attenuation, and background. Plans have been developed for archival of the spectra in a form readily accessible to the scientific, engineering and technical community engaged in space research and application. Work has been initiated in the process of estimating the flux of activating particles encountered by material at various locations of the spacecraft.

Laird, C. E.↗

Real-time three-dimensional echocardiographic study of left ventricular function after infarct exclusion surgery for ischemic cardiomyopathy

BACKGROUND: Infarct exclusion (IE) surgery, a technique of left ventricular (LV) reconstruction for dyskinetic or akinetic LV segments in patients with ischemic cardiomyopathy, requires accurate volume quantification to determine the impact of surgery due to complicated geometric changes. METHODS AND RESULTS: Thirty patients who underwent IE (mean age 61+/-8 years, 73% men) had epicardial real-time 3-dimensional echocardiographic (RT3DE) studies performed before and after IE. RT3DE follow-up was performed transthoracically 42+/-67 days after surgery in 22 patients. Repeated measures ANOVA was used to compare the values before and after IE surgery and at follow-up. Significant decreases in LV end-diastolic (EDVI) and end-systolic (ESVI) volume indices were apparent immediately after IE and in follow-up (EDVI 99+/-40, 67+/-26, and 71+/-31 mL/m(2), respectively; ESVI 72+/-37, 40+/-21, and 42+/-22 mL/m(2), respectively; P:<0.05). LV ejection fraction increased significantly and remained higher (0.29+/-0.11, 0.43+/-0.13, and 0.42+/-0.09, respectively, P:<0.05). Forward stroke volume in 16 patients with preoperative mitral regurgitation significantly improved after IE and in follow-up (22+/-12, 53+/-24, and 58+/-21 mL, respectively, P:<0.005). New York Heart Association functional class at an average 285+/-144 days of clinical follow-up significantly improved from 3.0+/-0.8 to 1.8+/-0.8 (P:<0.0001). Smaller end-diastolic and end-systolic volumes measured with RT3DE immediately after IE were closely related to improvement in New York Heart Association functional class at clinical follow-up (Spearman's rho=0.58 and 0.60, respectively). CONCLUSIONS: RT3DE can be used to quantitatively assess changes in LV volume and function after complicated LV reconstruction. Decreased LV volume and increased ejection fraction imply a reduction in LV wall stress after IE surgery and are predictive of symptomatic improvement.

Non-NASA Center↗

Evidence Report: Risk of Cardiovascular Disease and Other Degenerative Tissue Effects from Radiation Exposure

Occupational radiation exposure from the space environment may result in non-cancer or non-CNS degenerative tissue diseases, such as cardiovascular disease, cataracts, and respiratory or digestive diseases. However, the magnitude of influence and mechanisms of action of radiation leading to these diseases are not well characterized. Radiation and synergistic effects of radiation cause DNA damage, persistent oxidative stress, chronic inflammation, and accelerated tissue aging and degeneration, which may lead to acute or chronic disease of susceptible organ tissues. In particular, cardiovascular pathologies such as atherosclerosis are of major concern following gamma-ray exposure. This provides evidence for possible degenerative tissue effects following exposures to ionizing radiation in the form of the GCR or SPEs expected during long-duration spaceflight. However, the existence of low dose thresholds and dose-rate and radiation quality effects, as well as mechanisms and major risk pathways, are not well-characterized. Degenerative disease risks are difficult to assess because multiple factors, including radiation, are believed to play a role in the etiology of the diseases. As additional evidence is pointing to lower, space-relevant thresholds for these degenerative effects, particularly for cardiovascular disease, additional research with cell and animal studies is required to quantify the magnitude of this risk, understand mechanisms, and determine if additional protection strategies are required.The NASA PEL (Permissive Exposure Limit)s for cataract and cardiovascular risks are based on existing human epidemiology data. Although animal and clinical astronaut data show a significant increase in cataracts following exposure and a reassessment of atomic bomb (A-bomb) data suggests an increase in cardiovascular disease from radiation exposure, additional research is required to fully understand and quantify these adverse outcomes at lower doses (less than 0.5 gray (SI unit for ionizing radiation dosage, i.e. one joule of radiation energy per one kilogram of matter)) to facilitate risk prediction. This risk has considerable uncertainty associated with it, and no acceptable model for projecting degenerative tissue risk is currently available. In particular, risk factors such as obesity, alcohol, and tobacco use can act as confounding factors that contribute to the large uncertainties. The PELs could be violated under certain scenarios, including following a large SPE (solar proton event) or long-term GCR (galactic cosmic ray) exposure. Specifically, for a Mars mission, the accumulated dose is sufficiently high that epidemiology data and preliminary risk estimates suggest a significant risk for cardiovascular disease. Ongoing research in this area is intended to provide the evidence base for accurate risk quantification to determine criticality for extended duration missions. Data specific to the space radiation environment must be compiled to quantify the magnitude of this risk to decrease the uncertainty in current PELs and to determine if additional protection strategies are required. New research results could lead to estimates of cumulative radiation risk from CNS and degenerative tissue diseases that, when combined with the cancer risk, may have major negative impacts on mission design, costs, schedule, and crew selection. The current report amends an earlier report (Human Research Program Requirements Document, HRP-47052, Rev. C, dated Jan 2009) in order to provide an update of evidence since 2009.

Patel, Zarana↗

Quantifying and Characterizing Striping of Microwave Humidity Sounder with Observation and Simulation

Striping has been observed in the MetOp-A Microwave Humidity Sounder (MHS) data since its degradation in November 2018. However, accurate striping quantification and characterization remain challenging due to the large scene dynamics observed at W/G bands of MHS. Here we have developed a set of novel algorithms for striping quantification, decomposition, characterization, and simulation. Our algorithm extracts striping from the warm-load and cold-space scenes that are relatively stable. We break down the striping into two parts of thermal and 1/f noise and quantify their absolute magnitude and relative ratio. We found a significant increase in striping at 157 GHz that has more than quadrupled by October 2019 relative to its normal level. Regardless of the degradation, the ratio of thermal and 1/f noise remains the same. Our simulation reproduces all the characteristics of striping against observation. It is shown that 1/f noise generates sharp, non-periodic stripes, while thermal noise also generates stripes but with smoother band features. The latter is due to the periodic calibration that has a chopping effect. The striping percentage, defined as the ratio of 1/f to total noise, shows no dependence on the scene temperature. Striping is pronounced not only in 157 GHz but also in 89 and190 GHz with the striping percentage over 50%, while lower in183 GHz of 20%. The results provide insights for quantifying and understanding striping. Our algorithm can be applied to other radiometers and to simulate striping for evaluating its impact in data assimilation and science products.

John Xun Yang↗