Search NASA⌕ Search

SEARCH · Search NASA

Results for “adaptive weights”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Career Excess Mortality Risk from Diagnostic Radiological Exams Required for Crewmembers Participating in Long Duration Space Flight

NASA requires astronauts to undergo diagnostic x-ray examinations as a condition for their employment. The purpose of these procedures is to assess the astronaut s overall health and to diagnose conditions that could jeopardize the success of long duration space missions. These include exams for acceptance into the astronaut corps, routine periodic exams, as well as evaluations taken pre and post missions. Issues: According to NASA policy these medical examinations are considered occupational radiological exposures, and thus, are included when computing the astronaut s overall radiation dose and associated excess cancer mortality risk. As such, astronauts and administrators are concerned about the amount of radiation received from these procedures due to the possibility that these additional doses may cause astronauts to exceed NASA s administrative limits, thus disqualifying them from future flights. Methods: Radiation doses and cancer mortality risks following required medical radiation exposures are presented herein for representative male and female astronaut careers. Calculation of the excess cancer mortality risk was performed by adapting NASA s operational risk assessment model. Averages for astronaut height, weight, number of space missions and age at selection into the astronaut corps were used as inputs to the NASA risk model. Conclusion: The results show that the level of excess cancer mortality imposed by all required medical procedures over an entire astronaut s career is approximately the same as that resulting from a single short duration space flight (i.e. space shuttle mission). In short the summation of all medical procedures involving ionizing radiation should have no impact on the number of missions an astronaut can fly over their career. Learning Objectives: 1. The types of diagnostic medical exams which astronauts are subjected to will be presented. 2. The level of radiation dose and excess mortality risk to the average male and female astronaut will be presented.

Dodge, C. W.↗

Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures

Graphite epoxy composite (GEC) materials are used in the construction of rocket fairings, nose cones, interstage adapters, and heat shields due to their high strength and light weight. However, they absorb moisture depending on the environmental conditions they are exposed to prior to launch. Too much moisture absorption can become a problem when temperature and pressure changes experienced during launch cause the water to vaporize. The rapid state change of the water can result in structural failure of the material. In addition, heat and moisture combine to weaken GEC structures. Diffusion models that predict the total accumulated moisture content based on the environmental conditions are one accepted method of determining if the material strength has been reduced to an unacceptable level. However, there currently doesn t exist any field measurement technique to estimate the actual moisture content of a composite structure. A multi-layer diffusion model was constructed with Mathematica to predict moisture absorption and desorption from the GEC sandwich structure. This model is used in conjunction with relative humidity/temperature sensors both on the inside and outside of the material to determine the moisture levels in the structure. Because the core materials have much higher diffusivity than the face sheets, a single relative humidity measurement will accurately reflect the moisture levels in the core. When combined with an external relative humidity measurement, the model can be used to determine the moisture levels in the face sheets. Since diffusion is temperaturedependent, the temperature measurements are used to determine the diffusivity of the face sheets for the model computations.

Nurge, Mark↗

Improving Deep Neural Networks’ Training for Image Classification With Nonlinear Conjugate Gradient-Style Adaptive Momentum

Momentum is crucial in stochastic gradient-based optimization algorithms for accelerating or improving training deep neural networks (DNNs). In deep learning practice, the momentum is usually weighted by a well-calibrated constant. However, tuning the hyperparameter for momentum can be a significant computational burden. In this article, we propose a novel adaptive momentum for improving DNNs training; this adaptive momentum, with no momentum-related hyperparame- ter required, is motivated by the nonlinear conjugate gradient (NCG) method. Stochastic gradient descent (SGD) with this new adaptive momentum eliminates the need for the momentum hyperparameter calibration, allows using a significantly larger learning rate, accelerates DNN training, and improves the final accuracy and robustness of the trained DNNs. For example, SGD with this adaptive momentum reduces classification errors for training ResNet110 for CIFAR10 and CIFAR100 from 5.25% to 4.64% and 23.75% to 20.03%, respectively. Furthermore, SGD, with the new adaptive momentum, also benefits adversarial training and, hence, improves the adversarial robustness of the trained DNNs.

97 MATHEMATICS AND COMPUTING↗

Structural and Functional Adaptation of the Vestibular Otolith to Altered Gravity from Microgravity to Hypergravity

Inertial acceleration and a change in head orientation with respect to gravity are sensed by mechanosensitive receptors in the inner ear otolith organs. These structures consist of calcium carbonate grains called otoconia that mechanically load the hair cell bundles and distribute the tangential shear force during movement, and changes in their density can alter hair cell sensitivity. A possible adaptive response to a chronic gravity change is a change in weight-lending otoconia. Another mechanism is a modification of the strength and number of synapses coupling the hair cells to nerve afferents that convey the signals into the brain. Here, we present the results obtained in 2 species exposed both to µG (microgravity) and hyper-gravity (HG). Adult toadfish, Opsanus tau, were exposed to µG (microgravity) in 2 shuttle missions and to 1.12-2.24G (force of gravity) [resultant] centrifugation for 1-32 days; readaptation was studied following 1-8 days after return to 1G. Results show a biphasic pattern in response to 2.24G: initial hypersensitivity, similar to that observed after µG (microgravity) exposure, followed by transition to a significant decrease at 16-32 days. Recovery from HG exposure is approximately 4-8 days. Two major pieces of information are still needed: vertebrate hair cell response to altered gravity and impact of longer duration exposures on sensory plasticity. To address the latter we applied electron microscopic techniques to image otoconia mass obtained from 1) mice subjected to 91-days of µG (microgravity) in the Mouse Drawer System (MDS) flown on International Space Station, 2) mice subjected to 91-days of 1.24G centrifugation on ground, and 3) mice flown on 2 shuttle missions. Images from MDS mice indicate a clear restructuring of individual otoconia, suggesting deposition to the outer shell. Images from their HG ground counterparts indicate the converse - an ablation of the otoconia mass. For 13-day exposures to µG (microgravity) mice otoconia appear normal. Despite the permanence of gravity in evolution the animal senses exposure to a novel, non-1G, environment and adaptive mechanisms are initiated - in the short term compensation is likely confined to the peripheral sensory receptors, the brain or both. For longer exposures structural modifications of the otolith mass may also result.

Otoconia↗

Enhanced skeletal muscle insulin sensitivity in year-old rats adapted to hypergravity

Rats induced into a hypermetabolic state by exposure to chronic (7 mo) centrifugation at 4.15 g exhibited increased glucose uptake at lower plasma insulin levels than weight-matched control animals following oral glucose administration. In order to determine the insulin sensitivity of specific tissues, the effect of exogenous insulin on glucose uptake by isolated perfused livers and hindlim skeletal muscle from rats adapted to chronic centrifugation for one year was compared with perfused tissue from 2.5 mo-old noncentrifuged control animals of equal body weight. Metabolic glucose clearance by skeletal muscle from hypergravic rats did not prove significantly greater than control muscle when perfused in the absence of insulin (10.6 vs 8.1 microliters/min-g-muscle), but was twice as fast (23.0 vs 9.5) at perfusate insulin levels of 35 micro-U/ml. Conversely, glucose uptake by hypergravic livers was significantly decreased (P is less than 0.001) compared with control livers (10.3 vs 27.8) at perfusate insulin levels of 40 micro-U/ml. Results suggest that skeletal muscle rather than liver is primarily responsible for the enhanced sensitivity to insulin and the increased energy expenditure observed in rats subjected to hypergravity.

Mondon, C. E.↗

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Suppression of Nonlinear Rotary Slosh Dynamics Using the SLS Adaptive Augmenting Control System Demonstration on a Quadcopter Testbed

Liquid propellant makes up a significant portion of the total weight for large launch vehicles such as Saturn V, Space Shuttle, and the Space Launch System. Careful attention must be given to the influence of fuel slosh motion on the stability of the vehicle in the design of the Flight Control System (FCS). Historically, there have been instances where a poorly designed FCS in addition to a lack of passive damping have caused the slosh mass to drive the launch vehicle unstable. The dynamics behind controlling a quadcopter/hanging mass configuration is analogous to that of controlling the attitude of a rocket with a single propellant tank. The quadcopter/hanging mass configuration offers a reasonably accurate platform for assessing the real-time effectiveness of the SLS Adaptive Augmenting Controller in suppressing slosh instability. Flight test experiments were carried out at the NASA Langley Research Center's Autonomy Incubator. During both simulation and flight test, the hanging mass was intentionally made unstable and the adaptive algorithm successfully suppressed the instability as expected.

Pei, Jing↗

Optimizing transmit field inhomogeneity of parallel RF transmit design in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B+1) inhomogeneities, leading to uneven flip angles and image intensity anomalies. These issues can significantly degrade imaging quality and its medical applications. This study addresses B+1 field homogeneity through a novel deep learning-based strategy. Traditional methods like Magnitude Least Squares (MLS) optimization have been effective but are time-consuming and dependent on the patient’s presence. Recent machine learning approaches, such as RF Shim Prediction by Iteratively Projected Ridge Regression and deep learning frameworks, have shown promise but face limitations like extensive training times and oversimplified architectures. We propose a two-step deep learning strategy. First, we obtain the desired reference RF shimming weights from multi-channel B+1 fields using random-initialized Adaptive Moment Estimation. Then, we employ Residual Networks (ResNets) to train a model that maps B+1 fields to target RF shimming outputs. Our approach does not rely on pre-calculated reference optimizations for the testing process and efficiently learns residual functions. Comparative studies with traditional MLS optimization demonstrate our method’s advantages in terms of speed and accuracy. The proposed strategy achieves a faster and more efficient RF shimming design, significantly improving imaging quality at UHF. This advancement holds potential for broader applications in medical imaging and diagnostics.

Lu, Zhengyi [Vanderbilt University]↗

Use of TV in space science activities - Some considerations

Advantages in the use of TV on board satellites as the primary data-recording system in a manned space laboratory when certain types of experiments are flown are indicated. Real-time or near-real-time validation, elimination of film weight, improved depth of field and low-light sensitivity, and better adaptability to computer and electronic processing of data are spelled out as advantages of TV over photographic techniques, say, in fluid dynamics experiments, and weightlessness studies.

Bannister, T. C.↗

Neural network with dynamically adaptable neurons

This invention is an adaptive neuron for use in neural network processors. The adaptive neuron participates in the supervised learning phase of operation on a co-equal basis with the synapse matrix elements by adaptively changing its gain in a similar manner to the change of weights in the synapse IO elements. In this manner, training time is decreased by as much as three orders of magnitude.

Tawel, Raoul↗

Body mass, energy intake, and water consumption of rats and humans during space flight

Alteration of metabolism has been suggested as a major limiting factor to long-term space flight. In humans and primates, a negative energy balance has been reported. The metabolic response of rats to space flight has been suggested to result in a negative energy balance. We hypothesized that rats flown in space would maintain energy balance as indicated by maintenance of caloric intake and body mass gain. Further, the metabolism of the rat would be similar to that of laboratory-reared animals. We studied the results from 15 space flights lasting 4 to 19 d. There was no difference in average body weight (206 +/- 13.9 versus 206 +/- 14.8 g), body weight gain (5.8 +/- 0.48 versus 5.9 +/- 0.56 g/d), caloric intake (309 +/- 21.0 versus 309 +/- 20.1 kcal/kg of body mass per day), or water intake (200 +/- 8.6 versus 199 +/- 9.3 mL/kg of body mass per day) between flight and ground control animals. Compared with standard laboratory animals of similar body mass, no differences were noted. The observations suggested that the negative balance observed in humans and non-human primates may be due to other factors in the space-flight environment.

Non-NASA Center↗

The Role of Adaptation in Body Load-Regulating Mechanisms During Locomotion

Body loading is a fundamental parameter that modulates motor output during locomotion, and is especially important for controlling the generation of stepping patterns, dynamic balance, and termination of locomotion. Load receptors that regulate and control posture and stance in locomotion include the Golgi tendon organs and muscle spindles at the hip, knee, and ankle joints, and the Ruffini endings and the Pacinian corpuscles in the soles of the feet. Increased body weight support (BWS) during locomotion results in an immediate reorganization of locomotor control, such as a reduction in stance and double support duration and decreased hip, ankle, and knee angles during the gait cycle. Previous studies on the effect during exposure to increased BWS while walking showed a reduction in lower limb joint angles and gait cycle timing that represents a reorganization of locomotor control. Until now, no studies have investigated how locomotor control responds after a period of exposure to adaptive modification in the body load sensing system. The goal of this research was to determine the adaptive properties of body load-regulating mechanisms in locomotor control during locomotion. We hypothesized that body load-regulating mechanisms contribute to locomotor control, and adaptive changes in these load-regulating mechanisms require reorganization to maintain forward locomotion. Head-torso coordination, lower limb movement patterns, and gait cycle timing were evaluated before and after a 30-minute adaptation session during which subjects walked on a treadmill at 5.4 km/hr with 40% body weight support (BWS). Before and after the adaptation period, head-torso and lower limb 3D kinematic data were obtained while performing a goal directed task during locomotion with 0% BWS using a video-based motion analysis system, and gait cycle timing parameters were collected by foot switches positioned under the heel and toe of the subjects shoes. Subjects showed adaptive modification in the body load-regulating mechanisms that included increased head movement amplitude, increased knee and ankle flexion, and increased stance, stride, and double support time, with no change in the performance of the task with respect to that measured before exposure to BWS. These changes in locomotor control are opposite to that reported during 40% BWS exposure and indicative of an after-effect after removal of the adaptive stimulus. Therefore, it is evident that just 30 minutes of 40% BWS during locomotion was sufficient to induce adaptive modifications in the body load sensing systems that contribute to reorganization of sensory contributions to stable locomotor control.

Ruttley, Tara↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Physiological Adaptations and Countermeasures Associated with Long-Duration Space Flights

On earth, the presence of gravity imposes weight-bearing gradients on tissues which influence the functions of multiple integrative systems. On the other hand, conditions of actual or simulated microgravity can modify and/or nullify these gradients and subsequently alter structure and function. The purpose of this symposium is to discuss the results from short-term Shuttle flights, long term Skylab or Mir missions, or long-term ground based experiments which indicate or suggest that performance has been or could be compromised in space missions of long durations (>one year) or with space tasks (e.g. building space stations) with the goal of identifying countermeasures that could minimize or eliminate the expected anatomical and physiological consequences. After an overview by C. Tipton from the U. Arizona, the countermeasures necessary for the fluid shifts and select functions of the cardiovascular system will be discussed by A. Hargens from NASA Ames Research Center. He will be followed by K. Baldwin of the U. California at Irvine who will discuss the countermeasures needed to prevent the changes that alter the structure, function and control of skeletal muscles. Since changes in bone mass with microgravity are a major concern of NASA, V. Schneider from NASA Headquarters will present data and the countermeasures for bone. Although the results are limited, the changes in the endocrine and immune system deserve mentioning and C. Tipton will assume this responsibility. V. Convertino from the Air Force School of Aerospace Medicine has the challenge of discussing the role, importance, and the specificity of exercise as an effective countermeasure while I. Kozlovskaya from Moscow will elaborate on the Russian experiences with past countermeasures and provide a viewpoint on future ones. After the brief (25 min.) presentations, the speakers will assemble as a panel to discuss the issues raised and the concerns of the audience.

Tipton, C. M.↗

Managing the Risk for Early Onset Osteoporosis in Long-Duration Astronauts Due to Spaceflight

Early Onset Osteoporosis is probably the most recognized but poorly understood long-term health risk due to spaceflight. Osteoporosis management is primarily prophylactic and clinical interventions rely upon the ability to predict fractures which is currently determined by surrogate measures of bone strength. The RMAT for Early Onset Osteoporosis identified some open issues related to the fact that long-duration astronauts compose a unique group of subjects for which clinical approaches for osteoporosis management do not apply. Long-duration astronauts are healthy, young (25 to 55 years of age), predominantly male, and physical fit relative to the typical osteoporosis patient. Moreover, during prolonged space missions (typically 6-month missions) the skeleton not only adapts to weightlessness, but is influenced by numerous risk factors induced by operational constraints, e.g., inability to maintain preflight weight-bearing and aerobic activities, sub-optimal dietary intake (e.g., high sodium content for food stability, lack of fresh fruit and vegetables), suppression of vitamin D metabolism by uv shielding, and remote medicine care. Moreover, adaptation results in novel changes to astronauts bones that cannot be detected by current medically-useful measures. Consequently, a panel of clinicians (recognized leaders and policy-makers in osteoporosis) was convened to review the dataset of bone measures and bone loss risk factors in long-duration astronauts. Driven by the queries in the RMAT, the panel was charged to determine 1) if an intervention is required to prevent this risk, 2) what type and at what time would intervention be optimal, 3) what is the clinical trigger that would require a medical response from flight surgeons and 4) how should research data be used in the clinical care of astronauts. Hence, the RMAT determined that a bone health policy need to be formulated specific for this unique cohort subjected to a novel skeletal condition

Sibonga, Jean D.↗

Towards a unified nonlocal, peridynamics framework for the coarse-graining of molecular dynamics data with fractures

Molecular dynamics (MD) has served as a powerful tool for designing materials with reduced reliance on laboratory testing. However, the use of MD directly to treat the deformation and failure of materials at the mesoscale is still largely beyond reach. In this work, we propose a learning framework to extract a peridynamics model as a mesoscale continuum surrogate from MD simulated material fracture data sets. Firstly, we develop a novel coarse-graining method, to automatically handle the material fracture and its corresponding discontinuities in the MD displacement data sets. Inspired by the weighted essentially non-oscillatory (WENO) scheme, the key idea lies at an adaptive procedure to automatically choose the locally smoothest stencil, then reconstruct the coarse-grained material displacement field as the piecewise smooth solutions containing discontinuities. Then, based on the coarse-grained MD data, a two-phase optimization-based learning approach is proposed to infer the optimal peridynamics model with damage criterion. In the first phase, we identify the optimal nonlocal kernel function from the data sets without material damage to capture the material stiffness properties. Then, in the second phase, the material damage criterion is learnt as a smoothed step function from the data with fractures. As a result, a peridynamics surrogate is obtained. As a continuum model, our peridynamics surrogate model can be employed in further prediction tasks with different grid resolutions from training, and hence allows for substantial reductions in computational cost compared with MD. We illustrate the efficacy of the proposed approach with several numerical tests for the dynamic crack propagation problem in a single-layer graphene. Our tests show that the proposed data-driven model is robust and generalizable, in the sense that it is capable of modeling the initialization and growth of fractures under discretization and loading settings that are different from the ones used during training.

97 MATHEMATICS AND COMPUTING↗

Adaptive Interface-PINNs (AdaI-PINNs) for inverse problems: Determining material properties for heterogeneous systems

Here, we determine spatially varying discontinuous material properties using a domain-decomposition based physics-informed neural networks (PINNs) framework named the Adaptive Interface-PINNs or AdaI-PINNs (Roy et al., 2024). We propose the use of distinct neural networks for the field variables and material properties within each material, utilizing adaptive activation functions. While the neural networks across different materials share the same weights and biases, their activation functions are uniquely tailored using a hyperparameter that influences the slope of the activation function. The proposed framework is tested on several one-dimensional and two-dimensional benchmark examples, and its performance is compared with conventional PINNs and existing domain-decomposition PINNs frameworks, namely, the Multi-domain physics-informed neural network (M-PINN), and the eXtended physics-informed neural networks (XPINNs). The results demonstrate that the proposed approach can determine randomly distributed discontinuous material properties with an L 2 error of $\mathscr{O}$ (10 -3 ) for the material property and the root-mean-square error of $\mathscr{O}$ (10 -3 ) for the primary variable while the other approaches yield errors that are approximately two orders of magnitude larger (that is, $\mathscr{O}$ (10 -1 )). Moreover, the spatial distribution of material properties obtained using the proposed framework is in close agreement with the true distribution, whereas the other approaches fare much worse. Additionally, the proposed approach is approximately 40% faster than its competitors, indicating its potential as a robust alternative for solving inverse problems in heterogeneous materials.

36 MATERIALS SCIENCE↗

Private Tabular Survey Data Products through Synthetic Microdata Generation

We propose two synthetic microdata approaches to generate private tabular survey data products for public release. We adapt a pseudo posterior mechanism that downweights by-record likelihood contributions with weights ∈[0,1] based on their identification disclosure risks to producing tabular products for survey data. Our method applied to an observed survey database achieves an asymptotic global probabilistic differential privacy guarantee. Our two approaches synthesize the observed sample distribution of the outcome and survey weights, jointly, such that both quantities together possess a privacy guarantee. The privacy-protected outcome and survey weights are used to construct tabular cell estimates (where the cell inclusion indicators are treated as known and public) and associated standard errors to correct for survey sampling bias. Through a real data application to the Survey of Doctorate Recipients public use file and simulation studies motivated by the application, we demonstrate that our two microdata synthesis approaches to construct tabular products provide superior utility preservation as compared to the additive noise approach of the Laplace Mechanism. Moreover, our approaches allow the release of microdata to the public, enabling additional analyses at no extra privacy cost.

Mathematical Methods In Social Sciences↗