Search NASA⌕ Search

SEARCH · Search NASA

Results for “arc jet testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Simulation of HyMETS Flowfield Around Baby-SPRITE Entry Probe

Arc-jets are unique facilities used in research, development, and evaluation of high-temperature thermal protection systems for hypersonic vehicles and planetary entry systems. Thermochemical non-equilibrium computational fluid dynamics simulations have been carried out for the Hypersonic Materials Environmental Test System arc-jet facility to determine the size of a capsule model before arc-jet testing by better understanding of the physical phenomena. The results show the effect of the test article geometry and the importance of high-quality grids for accurate solutions. Accurate computational modeling of hypersonic flow fields inside arc-jets under simulated planetary entry conditions would help improve the design of thermal protection systems that may enable human exploration of the Moon, Mars, and beyond.

Ventura Diaz, Patricia↗

Arc Jet Flow Properties Determined from Laser- Induced Fluorescence of Atomic Species

Flow property measurements that were recently acquired in the Ames Research Center Aerodynamic Heating Facility (AHF) arc jet using two-photon Laser-Induced Fluorescence (LIF) of atomic nitrogen and oxygen are reported. The measured properties, which include velocity, translational temperature, and species concentration, cover a wide range of facility operation for the 30 cm nozzle. During the tests, the arc jet pressure and input stream composition were maintained at fixed values and the arc current was varied to vary the flow enthalpy. As part of this ongoing effort, a measurement of the two-photon absorption coefficient for the 3p4D(left arrow)2p4S transition of atomic nitrogen was performed, and the measured value is used to convert the relative concentration measurements to absolute values. A flow reactor is used to provide a known temperature line shape profile to deconvolve the laser line width contribution to the translational temperature measurements. Results from the current experiments are compared with previous results obtained using NO-beta line profiles at room temperature and the problem of multimode laser oscillation and its impact on the two-photon excitation line shape are discussed. One figure is attached, and this figure show relative N atom concentration measurements as a function of the arc power. Other measurements have already been acquired and analyzed. The arc jet flow facilities are heavily used in thermal protection material development and evaluation. All hypersonic flight and planetary atmospheric entry vehicles will use materials tested in these arc jet facilities. This poster represents an application of laser-spectroscopic measurements in an important test facility.

Fletcher, Douglas G.↗

The Adaptable, Deployable, Entry and Placement Technology (ADEPT) Enabling Advanced Entry, Descent, and Landing Capabilities for SmallSat Missions

The Adaptable, Deployable Entry and Placement Technology (ADEPT) is a mechanically deployable low-ballistic coefficient aeroshell entry system which performs entry, descent, and landing (EDL) functions for a broad range of planetary destinations including Mars, Venus, Titan and Earth. The deployable system allows mission planners to develop an aeroshell design that is stowed like a folded umbrella, and yet prior to the EDL mission segment, transforms into a deployed, near-rigid low ballistic coefficient configuration. The ADEPT architecture is scalable from a sub-1m class to 6m diameter entry vehicles for Venus and and it has been studied at up to 15m – 20m scale for human exploration class missions. There has been growing interest in performing interplanetary missions with small spacecraft as secondary payloads and ADEPT offers small satellite mission designers the ability to consider Aeroassist technologies to expand mission applications. The ADEPT architecture introduces a new approach for entry vehicle design. It deploys a flexible 3D woven carbon fabric as the primary drag surface. It is capable of surviving high aerothermal heating during entry, while maintaining a robust impermeable membrane that provides high drag for vehicle deceleration. The ADEPT project team has advanced this decelerator technology via systems-level testing at the one meter diameter (nano-ADEPT) scale. A subsonic aeroloads test (May 2015) and a pathfinder arc-jet aeroheating test (Sept 2015) and a successful sounding rocket flight (SR-1) launch of a 0.7 meter deployed diameter ADEPT (September 2018). The SR-1 flight experiment demonstrated most of the primary end-to-end mission stages including: launch in a stowed configuration, separation and deployment in zero-g, exo-atmospheric conditions, and passive ballistic re-entry of a 70 degree half-angle cone geometry. The ADEPT SR-1 sounding rocket flight experiment had to address challenges such as stowing within the constrained payload envelope, fabric folding, and packaging concerns.

Paul Wercinski↗

New Stagnation Arc Jet Model Design for Testing ADEPT 3-D Carbon Cloth

The ADEPT concept has been considered as an entry, descent and landing system to enable Human Mars class missions. Ground rules for the Mars studies required aerocapture, orbit, and then entry. The design utilizes a 3-D woven carbon cloth fabric as both heatshield and primary structure and design guidelines required 6 layers remaining after all entry events. The peak heating predicted for the ADEPT carbon cloth was 35 Wcm2 and resulting temperatures were predicted to be 1400K. Predictions for carbon mass loss were performed using equilibrium thermochemistry, which is only accurate for T2000K. Carbon oxidation is kinetically controlled at T2000K, and mass loss drops off considerably from equilibrium values. Design of the cloth thickness and mass would be significantly reduced if kinetics were considered. This effort was to design a stagnation test article design that could be used in the AHF with varying levels of oxygen where the results could be used to develop an engineering model to describe the recession rate of the carbon as a function of the partial pressure of monotomic oxygen.

carbon cloth↗

Remote Recession Measurements of Wire-Seeded PICA Samples in an Arc-Jet Flow

Various methods for remote recession sensing of PICA have been developed and several seeding methods have been tested. The most recent method involved seeding the ablator with wires fed to the sample from the backside with a defined amount of PICA left towards the upstream front of the sample. This seed method mimics the installation of in-depth thermocouples as they are frequently used in ground testing and flight. Arc-jet tests were conducted in the NASA Langley HYMETS facility at a heat flux of 320 W/sq.cm. The emission of the post-shock layer was observed in spectral resolution from the side along an optical axis perpendicular to the arc-jet flow and from the front, looking at the sample surface from an upstream position. Various metallic seed materials with different melting points were used. In addition to the emission spectroscopy measurements, the samples were monitored during the tests through pyrometry and videography. The time resolved response of the seeded material is described and compared to earlier tests with different seeding methods. The combination of seed materials was found to be critical for the selection of emission signatures characteristic for the material recession which can be isolated in the final emission spectra.

Winter, Michael↗

Analysis of Flow From Arc-Jet Spectra

Materials testing is carried out at the JSC Atmospheric Reentry Materials and Structures Facility. A flow diagnostics program is under development to characterize the energy distribution in arc-jet flows used to simulate atmospheric entry. Heat transfer to materials depends on flow properties which includes the composition of and energy distribution among the atoms, ions, molecules, and molecular ions which make up the flow. This project involves analysis of shock layer characteristics from the radiation emitted and experimentally collected from near the front of the shock to near the surface of the material. The analysis has yielded information on relative populations of neutral molecules and molecular ions within the layer. In determining non-equilibrium temperatures within the layer, some insight into the spectral constants used to compute radiative emission has been gained.

Blackwell, H. E.↗

Testing with the Laser-Enhanced Arc Jet Facility (LEAF) at NASA Ames Research Center

NASA's new Laser-Enhanced Arcjet Facility (LEAF) employs 200 kilowatts of continuous-wave fiber lasers, combined with a 60-megawatt arc plasma jet, to simulate the combined radiative and convective heating is now operational and Orion heat-shield material is undergoing testing. This upgrade to the existing Interaction Heating Facility (IHF) involves the addition of high-power fiber lasers that project 1070nm radiative energy into the existing vacuum chamber. The optically expanded laser beam enters a side window of the test chamber to form either a uniform 150 x 150 mm or a 425 x 425 mm square spot on a wedge-shaped model holder. Combined heating levels of up to 180 W/cm2 convective with either 300 W/cm2 or 100 W/cm2 are achievable. This allows the arc jet and lasers to simulate dynamic entry-heating profiles encountered during entry by the Orion crew capsule for the lunar return conditions. New computational investigations are underway to explore testing with the objective of defining ablative material failure limit. Typical arc-jet testing is performed with test article that are stagnation or wedge geometries. The existing convective heating test facility combined with test article design limits how high a combined shear, heat-flux and pressure conditions can be achieved. With the addition of laser power of 200 kW, much higher combined conditions of high heat-flux, pressure and shear is achievable on a wedge or a swept-cylinder article. Such testing possibilities will allow us to progressively increase the combined conditions and explore when an ablative TPS material may fail. The presentation provides an overview of the LEAF and present results from the on-going Orion Testing.

Venkatapathy, Ethiraj↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

CFD↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

Goekcen, Tahir↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 10.16-cm iso-q and 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Evaluation of Thermal Control Coatings for Flexible Ceramic Thermal Protection Systems

This report summarizes the evaluation and testing of high emissivity protective coatings applied to flexible insulations for the Reusable Launch Vehicle technology program. Ceramic coatings were evaluated for their thermal properties, durability, and potential for reuse. One of the major goals was to determine the mechanism by which these coated blanket surfaces become brittle and try to modify the coatings to reduce or eliminate embrittlement. Coatings were prepared from colloidal silica with a small percentage of either SiC or SiB6 as the emissivity agent. These coatings are referred to as gray C-9 and protective ceramic coating (PCC), respectively. The colloidal solutions were either brushed or sprayed onto advanced flexible reusable surface insulation blankets. The blankets were instrumented with thermocouples and exposed to reentry heating conditions in the Ames Aeroheating Arc Jet Facility. Post-test samples were then characterized through impact testing, emissivity measurements, chemical analysis, and observation of changes in surface morphology. The results show that both coatings performed well in arc jet tests with backface temperatures slightly lower for the PCC coating than with gray C-9. Impact testing showed that the least extensive surface destruction was experienced on blankets with lower areal density coatings.

Kourtides, Demetrius↗

CFD Simulations of the IHF Arc-Jet Flow: 9-Inch Nozzle, Flow Surveys, LEAF Wedge Calibration Data

This paper reports computational analyses and flow characterization studies in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using a wedge model placed in a free jet downstream of new 9-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Both the nozzle and wedge model were specifically designed for testing in the new Laser-Enhanced Arc-jet Facility. Data were obtained using stagnation calorimeters and wedge models placed downstream of the nozzle exit. Two instrumented wedge calibration plates were used: one water-cooled and the other RCG-coated tile plate. Experimental surveys of arc-jet test flow with pitot and heat flux probes were also performed at three arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. By taking into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields, these simulations approximately reproduce the probe survey data and predict the wedge model surface pressure and heat flux measurements.

Arc-jets↗

Space Shuttle Orbiter carbon-carbon oxidation performance

Reusable, oxidation protected reinforced carbon carbon (RCC) has been successfully flown on forty Shuttle Orbiter flights. Thermal testing of the silicon carbide coated, reinforced carbon-carbon to determine its oxidation characteristics has been performed in both radiant and convective (plasma arc jet) heating test facilities. Subsurface oxidation of the RCC substrate as a result of oxygen penetrating micro cracks (fizzures) in the coating was characterized as a function of temperature and pressure for both convective and radiant environments. High temperature testing was performed to establish coating recession for over-temperature flight conditions experienced on abort trajectories. Suggested methods for using these test data to establish multi-mission reuse (i.e., mission life) and single mission limits are presented.

Curry, D. M.↗

MEDLI2: Ablator Models for Flight

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating[1,2]. Discrepancies between MEDLI’s flight heating data and predicted thermal response and recession[3] led to a campaign to characterize and test Mars2020 and MEDLI2 (Mars Entry, Descent, and Landing Instrument 2)[4] flight-lot thermal protection materials (TPS) at relevant ground test conditions. This paper covers the development and validation of flight-lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material SLA-561V (Super Lightweight Ablator). Virgin and char properties such as thermal conductivity and emissivity were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties were characterized and determined to be similar to prior TPS material measurements used for the heritage models. MEDLI2 also investigated the impact of the protective coating that was applied to MSL and Mars2020’s PICA heatshield to reduce the particulate matter shedding. Evidence from arc jet experiments on coated PICA showed that although there were no adverse effects on the performance of the TPS, there were differences in the in-depth temperatures and reduced recession compared to material response predictions of uncoated PICA.[5,6]. Fully Implicit Ablation and Thermal response (FIAT)[7] material response simulations were conducted with the heritage and MEDLI2 flight-lot material models. FIAT-predicted in-depth temperature responses and recession predictions were compared to flight-lot certification ground-test arc jet test data and MEDLI2 thermocouple data.

Materials Response↗

Reconstruction of Thermal Protection System Aeroheating using a Green’s Function Approach

Inverse heat transfer (IHT) techniques are often used to reconstruct the surface heating conditions on spacecraft thermal protection systems (TPS) during atmospheric entry. Current IHT techniques for entry spacecraft applications, however, demand substantial computational resources, and are impractical for analyses such as uncertainty quantification and real-time health monitoring. In this paper, a Green’s function sensor fusion approach is used to reconstruct the TPS surface aeroheating conditions on experimental spaceflight and ground test systems from collocated temperature and heat flux sensors embedded in the TPS. The algorithm leverages Green’s functions to model the heat conduction within the spacecraft TPS and stabilizes the recovery of the surface heating condition using the direct heat flux sensor measurement. The algorithm is validated using arc-jet ground test data and applied to the reconstruction of the Mars 2020 backshell heating during Martian atmospheric entry. The performance of the algorithm is benchmarked against a current state-of-the-art IHT framework, FIAT_Opt. The Green’s function-based reconstruction algorithm recovers the net hot-wall heat flux absorbed by the TPS and the incident heat flux from the atmospheric entry environment in close agreement with FIAT_Opt. Notably, computation of the surface heating condition is completed in three orders of magnitude less time with the Green’s function sensor fusion approach using a consumer-grade PC, versus with FIAT_Opt running on a high performance computer cluster. The efficiency of the algorithm is leveraged to compute the uncertainty contributions of input parameters to the total uncertainty in reconstructed Mars 2020 backshell heating for the full atmospheric entry heat pulse. The sensitivity analysis uncovers that, at different times throughout the entry heat pulse, uncertainties in the TPS specific heat, thermal conductivity, and emissivity are all dominant drivers of the reconstruction uncertainty. These results demonstrate Green’s functions and sensor-fusion techniques as promising IHT approaches to reconstruct atmospheric entry environments from TPS-embedded measurements, and highlight how these techniques may give access to post-flight analyses previously hindered by the prohibitive cost of current methods.

Kenneth McAfee↗