Search NASA⌕ Search

SEARCH · Search NASA

Results for “array cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

210 records · Page 12

Source circuit design considerations

The cost of several circuit configurations for large (5MW) array fields were investigated to assess the relative costs of high and low voltage configurations. Three source circuit NOC voltages were evaluated: 400V (ungrounded), 800V (+ or 400V center grounded), and 2000V (+ or - 1000V center grounded). Four source circuit configurations were considered for each of the three NOC voltages. The configurations correspond to source circuit currents of 15, 30, 45, and 60 amperes, respectively. Conceptual layouts for 5MW building blocks for each of the above configurations were developed. The designs were optimized to minimize BOS electrical and structural costs. Only the BOS electrical costs were evaluated. The designs were broken down into the following elements for cost: (1) basic source circuit intermodule wiring, bypass diodes and associated hardware, source circuit to J-Box wiring, etc; (2) J-Box blocking diodes, varistors, heat sinks, and housing; (3) disconnects source circuit disconnects, fuses, and housing; (4) bus cabling J-Box to PCU interface wiring, and trenching; (5) interface bus bar, group disconnects, and fuses; and (6) fault detection shunts, signal wire, electronics, and alarm. It is concluded that high voltage low current circuits are not economical, at higher currents high and low voltage circuit costs approach each other, high voltage circuits are not likely to offer near term advantage, and development work/manufacturer stimulation is needed to develop low cost high voltage hardware.

Noel, G. T.↗

NASA Tech Briefs, October 2012

Topics discussed include: Detection of Chemical Precursors of Explosives; Detecting Methane From Leaking Pipelines and as Greenhouse Gas in the Atmosphere; Onboard Sensor Data Qualification in Human-Rated Launch Vehicles; Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride; A Probabilistic Mass Estimation Algorithm for a Novel 7-Channel Capacitive Sample Verification Sensor; Low-Power Architecture for an Optical Life Gas Analyzer; Online Cable Tester and Rerouter; A Three-Frequency Feed for Millimeter-Wave Radiometry; Capacitance Probe Resonator for Multichannel Electrometer; Inverted Three-Junction Tandem Thermophotovoltaic Modules; Fabrication of Single Crystal MgO Capsules; Inflatable Hangar for Assembly of Large Structures in Space; Mars Aqueous Processing System; Hybrid Filter Membrane; Design for the Structure and the Mechanics of Moballs; Pressure Dome for High-Pressure Electrolyzer; Cascading Tesla Oscillating Flow Diode for Stirling Engine Gas Bearings; Compact, Low-Force, Low-Noise Linear Actuator; Ultra-Compact Motor Controller; Extreme Ionizing-Radiation-Resistant Bacterium; Wideband Single-Crystal Transducer for Bone Characterization; Fluorescence-Activated Cell Sorting of Live Versus Dead Bacterial Cells and Spores; Nonhazardous Urine Pretreatment Method; Laser-Ranging Transponders for Science Investigations of the Moon and Mars; Ka-Band Waveguide Three-Way Serial Combiner for MMIC Amplifiers; Structural Health Monitoring with Fiber Bragg Grating and Piezo Arrays; Low-Gain Circularly Polarized Antenna with Torus-Shaped Pattern; Stereo and IMU- Assisted Visual Odometry for Small Robots; Global Swath and Gridded Data Tiling; GOES-R: Satellite Insight; Aquarius iPhone Application; Monitoring of International Space Station Telemetry Using Shewhart Control Charts; Theory of a Traveling Wave Feed for a Planar Slot Array Antenna; Time Manager Software for a Flight Processor; Simulation of Oxygen Disintegration and Mixing With Hydrogen or Helium at Supercritical Pressure; A Superfluid Pulse Tube Refrigerator Without Moving Parts for Sub-Kelvin Cooling; Sapphire Viewports for a Venus Probe; The Mobile Chamber; Electric Propulsion Induced Secondary Mass Spectroscopy; and Radiation-Tolerant DC-DC Converters.

Source record↗

Mir Cooperative Solar Array Flight Performance Data and Computational Analysis

The Mir Cooperative Solar Array (MCSA) was developed jointly by the United States (US) and Russia to provide approximately 6 kW of photovoltaic power to the Russian space station Mir. The MCSA was launched to Mir in November 1995 and installed on the Kvant-1 module in May 1996. Since the MCSA photovoltaic panel modules (PPMs) are nearly identical to those of the International Space Station (ISS) photovoltaic arrays, MCSA operation offered an opportunity to gather multi-year performance data on this technology prior to its implementation on ISS. Two specially designed test sequences were executed in June and December 1996 to measure MCSA performance. Each test period encompassed 3 orbital revolutions whereby the current produced by the MCSA channels was measured. The temperature of MCSA PPMs was also measured. To better interpret the MCSA flight data, a dedicated FORTRAN computer code was developed to predict the detailed thermal-electrical performance of the MCSA. Flight data compared very favorably with computational performance predictions. This indicated that the MCSA electrical performance was fully meeting pre-flight expectations. There were no measurable indications of unexpected or precipitous MCSA performance degradation due to contamination or other causes after 7 months of operation on orbit. Power delivered to the Mir bus was lower than desired as a consequence of the retrofitted power distribution cabling. The strong correlation of experimental and computational results further bolsters the confidence level of performance codes used in critical ISS electric power forecasting. In this paper, MCSA flight performance tests are described as well as the computational modeling behind the performance predictions.

Kerslake, Thomas W.↗

Focal Fisheries Requirements for Floating Offshore Wind Co-Design in the Gulf of Maine and the Mid-Atlantic Bight

Floating offshore wind is an emerging renewable energy technology in U.S. waters and globally. Floating offshore wind technology is more complex than fixed-bottom installations, requiring platforms, moorings, and power cables that take up a larger footprint, both in the water column and along the seafloor. This complexity affects opportunities for compatibility between floating offshore wind and other ocean users, particularly fishermen, whose fishing gear also takes up space in the water column and along the seafloor. This report describes the results of semi-structured interviews with key fishing informants from two focal fisheries: (1) Gulf of Maine lobster (fixed gear) and (2) Mid-Atlantic Bight pelagic longline and recreational tuna (mobile gear). A total of six fishermen were interviewed: four from the Gulf of Maine and two from the Mid-Atlantic Bight. The interviews were designed to elicit information and opinions on the co-design of marine space for particular fishing gear and floating offshore wind infrastructure. Here, we provide an overview of participant fishing experience, the spatial requirements of specific gear types, self-reported comfort levels in different fishing scenarios, and concerns about accessing and operating within floating offshore wind arrays. This summary of fishermen s concerns around floating offshore wind infrastructure can guide future co-existence conversations.

17 WIND ENERGY↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗

Distributed Acoustic Sensing (DAS) on Opportunistic Networks_ A Feasibility Study Utilizing Fiber Optic Infrastructure at NEON Sites for DAS

This study demonstrates the feasibility of using Distributed Acoustic Sensing (DAS) on the opportunistic optical fiber infrastructure presented by NEON (National Ecological Observatory Network) sites. The test took place at the NEON Terrestrial Site designated D10 CPER. Unlit portions of the local fiber network were successfully spliced together and optimized for length and a Silixa iDAS sensor was installed. The resulting array (composed of 12 spliced fiber runs) totaled 875m in length. Over a period of 2 weeks, we gathered a high spatial and temporal resolution data set to characterize discernable signals and understand background noise. The data set was reviewed to extract wave signatures of identifiable origin, both anthropogenic and otherwise. Continent wide distribution of these sites makes them an interesting candidate for DAS and identifying measurable signal sources informs future DAS application on opportunistic fiber networks. These observations validate the utility of both the NEON and similarly small fiber networks (<1km) for geoscience, environmental, and security DAS applications and indicate possibilities for further inquiry in methods for DAS data collection and analysis.

42 ENGINEERING↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Array-Based Machine Learning for Functional Group Detection in Electron Ionization Mass Spectrometry

Mass spectrometry is a ubiquitous technique capable of complex chemical analysis. The fragmentation patterns that appear in mass spectrometry are an excellent target for artificial intelligence methods to automate and expedite the analysis of data to identify targets such as functional groups. To develop this approach, we trained models on electron ionization (a reproducible hard fragmentation technique) mass spectra so that not only the final model accuracies but also the reasoning behind model assignments could be evaluated. The convolutional neural network (CNN) models were trained on 2D images of the spectra using transfer learning of Inception V3, and the logistic regression models were trained using array-based data and Scikit Learn implementation in Python. Our training dataset consisted of 21,166 mass spectra from the United States’ National Institute of Standards and Technology (NIST) Webbook. The data was used to train models to identify functional groups, both specific (e.g., amines, esters) and generalized classifications (aromatics, oxygen-containing functional groups, and nitrogen-containing functional groups). We found that the highest final accuracies on identifying new data were observed using logistic regression rather than transfer learning on CNN models. It was also determined that the mass range most beneficial for functional group analysis is 0–100 m/z. We also found success in correctly identifying functional groups of example molecules selected from both the NIST database and experimental data. Beyond functional group analysis, we also have developed a methodology to identify impactful fragments for the accurate detection of the models’ targets. The results demonstrate a potential pathway for analyzing and screening substantial amounts of mass spectral data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The TMI Regenerative Solid Oxide Fuel Cell

Energy storage and production in space requires rugged, reliable hardware which minimizes weight, volume, and maintenance while maximizing power output and usable energy storage. Systems generally consist of photovoltaic solar arrays which operate (during sunlight cycles) to provide system power and regenerate fuel (hydrogen) via water electrolysis and (during dark cycles) fuel cells convert hydrogen into electricity. Common configurations use two separate systems (fuel cell and electrolyzer) in conjunction with photovoltaic cells. Reliability, power to weight and power to volume ratios could be greatly improved if both power production (fuel cells) and power storage (electrolysis) functions can be integrated into a single unit. The solid oxide fuel cell (SOFC) based design integrates fuel cell and electrolyzer functions and potentially simplifies system requirements. The integrated fuel cell/electrolyzer design also utilizes innovative gas storage concepts and operates like a rechargeable 'hydrogen-oxygen battery'. Preliminary research has been completed on improved H2/H20 electrode (SOFC anode/electrolyzer cathode) materials for regenerative fuel cells. Tests have shown improved cell performance in both fuel and electrolysis modes in reversible fuel cell tests. Regenerative fuel cell efficiencies, ratio of power out (fuel cell mode) to power in (electrolyzer mode), improved from 50 percent using conventional electrode materials to over 80 percent. The new materials will allow a single SOFC system to operate as both the electolyzer and fuel cell. Preliminary system designs have also been developed to show the technical feasibility of using the design for space applications requiring high energy storage efficiencies and high specific energy. Small space systems also have potential for dual-use, terrestrial applications.

Cable, Thomas L.↗

The TMI regenerable solid oxide fuel cell

Energy storage and production in space requires rugged, reliable hardware which minimizes weight, volume, and maintenance while maximizing power output and usable energy storage. These systems generally consist of photovoltaic solar arrays which operate during sunlight cycles to provide system power and regenerate fuel (hydrogen) via water electrolysis; during dark cycles, hydrogen is converted by the fuel cell into system. The currently preferred configuration uses two separate systems (fuel cell and electrolyzer) in conjunction with photovoltaic cells. Fuel cell/electrolyzer system simplicity, reliability, and power-to-weight and power-to-volume ratios could be greatly improved if both power production (fuel cell) and power storage (electrolysis) functions can be integrated into a single unit. The Technology Management, Inc. (TMI), solid oxide fuel cell-based system offers the opportunity to both integrate fuel cell and electrolyzer functions into one unit and potentially simplify system requirements. Based an the TMI solid oxide fuel cell (SOPC) technology, the TMI integrated fuel cell/electrolyzer utilizes innovative gas storage and operational concepts and operates like a rechargeable 'hydrogen-oxygen battery'. Preliminary research has been completed on improved H2/H2O electrode (SOFC anode/electrolyzer cathode) materials for solid oxide, regenerative fuel cells. Improved H2/H2O electrode materials showed improved cell performance in both fuel cell and electrolysis modes in reversible cell tests. ln reversible fuel cell/electrolyzer mode, regenerative fuel cell efficiencies (ratio of power out (fuel cell mode) to power in (electrolyzer model)) improved from 50 percent (using conventional electrode materials) to over 80 percent. The new materials will allow the TMI SOFC system to operate as both the electrolyzer and fuel cell in a single unit. Preliminary system designs have also been developed which indicate the technical feasibility of using the TMI SOFC technology for space applications with high energy storage efficiencies and high specific energy. Development of small space systems would also have potential dual-use, terrestrial applications.

Cable, Thomas L.↗

Apparatus Characterizes Transient Voltages in Real Time

The figure shows a prototype of a relatively inexpensive electronic monitoring apparatus that measures and records selected parameters of lightning-induced transient voltages on communication and power cables. The selected parameters, listed below, are those most relevant to the ability of lightning-induced transients to damage electronic equipment. This apparatus bridges a gap between some traditional transient-voltage recorders that record complete waveforms and other traditional transient-voltage recorders that record only peak values: By recording the most relevant parameters and only those parameters this apparatus yields more useful information than does a traditional peak-value (only) recorder while imposing much smaller data-storage and data-transmission burdens than does a traditional complete-waveform recorder. Also, relative to a complete-waveform recorder, this apparatus is more reliable and can be built at lower cost because it contains fewer electronic components. The transients generated by sources other than lightning tend to have frequency components well below 1 MHz. Most commercial transient recorders can detect and record such transients, but cannot respond rapidly enough for recording lightning-induced transient voltage peaks, which can rise from 10 to 90 percent of maximum amplitude in a fraction of a microsecond. Moreover, commercial transient recorders cannot rearm themselves rapidly enough to respond to the multiple transients that occur within milliseconds of each other on some lightning strikes. One transient recorder, designed for Kennedy Space Center earlier [ Fast Transient-Voltage Recorder (KSC- 11991), NASA Tech Briefs, Vol. 23, No. 10, page 6a (October 1999)], is capable of sampling transient voltages at peak values up to 50 V in four channels at a rate of 20 MHz. That recorder contains a trigger circuit that continuously compares the amplitudes of the signals on four channels to a preset triggering threshold. When a trigger signal is received, a volatile memory is filled with data for a total time of 200 ms. After the data are transferred to nonvolatile memory, the recorder rearms itself within 400 ms to enable recording of subsequent transients. Unfortunately, the recorded data must be retrieved through a serial communication link. Depending on the amount of data recorded, the memory can be filled before retrieval is completed. Although large amounts of data are recorded and retrieved, only a small part of the information (the selected parameters) is usually required. The present transient-voltage recorder provides the required information, without incurring the overhead associated with the recording, storage, and retrieval of complete transient-waveform data. In operation, this apparatus processes transient voltage waveforms in real time to extract and record the selected parameters. An analog-to-digital converter that operates at a speed of as much as 100 mega-samples per second is used to sample a transient waveform. A real-time comparator and peak detector are implemented by use of fast field-programmable gate arrays.

Medelius, Pedro↗