Search NASA⌕ Search

SEARCH · Search NASA

Results for “astronaut studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Orthostatic responses following 30-day bed rest deconditioning with isotonic and isokinetic exercise training

The effects of intensive exercise training on tilt tolerance following deconditioning of astronauts were investigated by studying orthostatic responses of 19 subjects who underwent two intensive exercise-training regimens during 30 days of -6-deg head-down bed rest (BR). Subjects were divided into no-exercise control group, and two exercise groups, one performing isotonic (Quinton ergometer) exercises, the other doing isokinetic (Lido ergometer) exercises. A 60-deg head-up tilt test was administered on the control day 1 and BR day 30; the test was terminated at 60 min or when presyncopal signs and/or symptoms occurred. It was found that exercise training did not affect tilt tolerance significantly.

Greenleaf, J. E.↗

EVA space construction - Experience and fundamental issues

Results are presented from EVA space construction studies performed in 1 g, simulated 0 g, and on-orbit. The studies include tests of astronaut participation on the Mobile Work Station concept and the Swing-Arm Beam Erector. Also, results from the Experimental Assembly of Structures in EVA and the Assembly Concept for Construction of Erectable Space Structure programs are summarized. EVA construction applications for the Space Station are discussed and construction scenarios are developed.

Heard, Walter L., Jr.↗

Cranial diameter pulsations measured by non-invasive ultrasound decrease with tilt

INTRODUCTION: Intracranial pressure (ICP) may play a significant role in physiological responses to microgravity by contributing to the nausea associated with microgravity exposure. However, effects of altered gravity on ICP in astronauts have not been investigated, primarily due to the invasiveness of currently available techniques. We have developed an ultrasonic device that monitors changes in cranial diameter pulsation non-invasively so that we can evaluate ICP dynamics in astronauts during spaceflight. This study was designed to demonstrate the feasibility of our ultrasound technique under the physiological condition in which ICP dynamics are changed due to altered gravitational force. METHODS: Six healthy volunteers were placed at 60 degrees head-up, 30 degrees headup, supine, and 15 degrees head-down positions for 3 min at each angle. We measured arterial blood pressure (ABP) with a finger pressure cuff, and cranial diameter pulsation with a pulsed phase lock loop device (PPLL). RESULTS: Analysis of covariance demonstrated that amplitudes of cranial diameter pulsations were significantly altered with the angle of tilt (p < 0.001). The 95% confidence interval for linear regression coefficients of the cranial diameter pulsation amplitudes with tilt angle was 0.862 to 0.968. However, ABP amplitudes did not show this relationship. DISCUSSION: Our noninvasive ultrasonic technique reveals that the amplitude of cranial diameter pulsation decreases as a function of tilt angle, suggesting that ICP pulsation follows the same relationship. It is demonstrated that the PPLL device has a sufficient sensitivity to detect changes non-invasively in ICP pulsation caused by altered gravity.

NASA Program Biomedical Research and Countermeasur↗

Lessons learned from Shuttle/Mir: psychosocial countermeasures

BACKGROUND: During future long-duration space missions, countermeasures need to be developed to deal with psychosocial issues that might impact negatively on crewmember performance and well-being. METHODS: In our recently completed NASA-funded study of 5 U.S. astronauts, 8 Russian cosmonauts, and 42 U.S. and 16 Russian mission control personnel who participated in the Shuttle/Mir program, we evaluated a number of important psychosocial issues such as group tension, cohesion, leadership role, and the displacement of negative emotions from crewmembers to people in mission control and from mission control personnel to management. RESULTS: Based on our findings, which are reviewed, a number of psychosocial countermeasures are suggested to help ameliorate the negative impact of potential psychosocial problems during future manned space missions. CONCLUSIONS: Crewmembers should be selected not only to rule out psychopathology but also to select-in for group compatibility and facility in a common language. Training should include briefings and team building related to a number of psychosocial issues and should involve both crewmembers and mission control personnel. During the mission, both experts on the ground and the crewmembers themselves should be alert to potential interpersonal problems, including the displacement of negative emotions from the crew to the ground. Supportive activities should consist of both individual and interpersonal strategies, including an awareness of changing leisure time needs. Finally, attention should be given to postmission readjustment and to supporting the families on Earth.

Non-NASA Center↗

Leadership Challenges in ISS Operations: Lessons Learned from Junior and Senior Mission Control Personnel

The International Space Station (ISS) is operated by a multi-national, multi-organizational team that is dispersed across multiple locations, time zones, and work schedules. At NASA, both junior and senior mission control personnel have had to find ways to address the leadership challenges inherent in such work, but neither have had systematic training in how to do so. The goals of this study were to examine the major leadership challenges faced by ISS mission control personnel and to highlight the approaches that they have found most effective to surmount them. We pay particular attention to the approaches successfully employed by the senior personnel and to the training needs identified by the junior personnel. We also evaluate the extent to which responses are consistent across the junior and senior samples. Further, we compare the issues identified by our interview survey to those identified by a standardized questionnaire survey of mission control personnel and a contrasting group of space station crewmembers. We studied a sample of 14 senior ISS flight controllers and a contrasting sample of 12 more junior ISS controllers. Data were collected using a semi-structured qualitative interview and content analyzed using an iterative process with multiple coders and consensus meetings to resolve discrepancies. To further explore the meaning of the interview findings, we also conducted new analyses of data from a previous questionnaire study of 13 American astronauts, 17 Russian cosmonauts, and 150 U.S. and 36 Russian mission control personnel supporting the ISS or Mir space stations. The interview data showed that the survey respondents had substantial consensus on several leadership challenges and on key strategies for dealing with them, and they offered a wide range of specific tactics for implementing these strategies. Interview data from the junior respondents will be presented for the first time at the meeting. The questionnaire data showed that the US mission control sample reported a level of support from their management that compared favorably to national norms. American mission control personnel and Russian crewmembers reported higher supervisor support than American crewmembers and Russian mission control personnel. We will present the specific issues underlying these findings and compare and contrast the results from the two datasets. Although specific to space station personnel, our results are consistent with recent management, cultural, and aerospace research. We aim to use our results to improve training for current and future mission control personnel.

Clement, James L.↗

EVA Assembly of Large Space Structure Neutral Buoyancy, Zero-Gravity Simulation: NASA-LaRC Nestable Columns and Joints

The film depicts an extravehicular activity (EVA) that involved the assembly of six "space-weight" columns into a regular tetrahedral cell by a team of two "space"-suited test subjects. This cell represents the fundamental "element" of a tetrahedral truss structure. The tests were conducted under simulated zero-gravity conditions, achieved by neutral buoyancy in water. The cell was assembled on an "outrigger" assembly aid off the side of a mockup of the Shuttle Orbiter cargo bay. Both manual and simulated remote manipulator system (RMS) modes were evaluated. The simulated RMS was used only to transfer stowed hardware from the cargo bay to the work sites. Articulation limits of the pressure suit and zero gravity could be accommodated by work stations with foot restraints. The results of this study have confirmed that astronaut EVA assembly of large, erectable space structur is well within man's capabilities.

TESTS↗

Participatory Exploration: The Role of the User Contribution System

This viewgraph presentation explores how NASA can apply the global shift in demographics, the popularity of collaborative technology and the desire for participation to the future of space exploration. Included in this is a review of the evolution of work, the engagement gap, user contribution systems and a case study concerning the "digital astronaut".

Skytland, Nicholas G.↗

Ceramic Adhesive and Methods for On-Orbit Repair of Re-Entry Vehicles

This adhesive is capable of repairing damaged leading edge components of reentry vehicles while in space, and is novel with regard to its ability to be applied in the vacuum of space, and in a microgravity environment. Once applied, the adhesive provides thermal and oxidation protection to the substrate (in this case, reinforced carbon/carbon composites, RCCs) during re-entry of a space vehicle. Although there may be many formulations for repair adhesives, at the time of this reporting, this is the first known adhesive capable of an on-orbit repair. The adhesive is an engineered ceramic material composed of a pre-ceramic polymer and refractory powders in the form of a paste or putty that can be applied to a scratched, cracked, or fractured composite surface, covering and protecting the damaged area. The adhesive is then "cured" with a heat cycle, thereby cross-linking the polymer into a hardened material and bonding it to the substrate. During the heat of reentry, the material is converted to a ceramic coating that provides thermal and oxidative stability to the repaired area, thus allowing the vehicle to pass safely from space into the upper atmosphere. Ceramic powders such as SiC, ZrB2 and Y2O3 are combined with allylhydridopolycarbosilane (AHPCS) resin, and are mixed to form a paste adhesive. The material is then applied to the damaged area by brush, spatula, trowel, or other means to fill cracks, gaps, and holes, or used to bond patches onto the damaged area. The material is then cured, in a vacuum, preferably at 250F (approximately equal to 121C) for two hours. The re-entry heating of the vehicle at temperatures in excess of 3,000F (approximately equal to 1,650C) then converts this material into a ceramic coating. This invention has demonstrated advantages in resistance to high temperatures, as was demonstrated in more than 100 arc-jet tests in representative environments at NASA. Extensive testing verified oxidation protection for the repaired substrate (RCC), and confirmed that the microstructure of the resulting repair leads to durability and resistance to melting or flow. Its processability and working life in a vacuum was demonstrated by NASA astronauts in glovebox processing studies, as well as on-orbit in the open space shuttle bay. All of these advantages increase the working life of NASA vehicles, as well as improve safety for any crew on a manned vehicle. The adhesive, trademarked NOAX(TM). or Non-Oxide Adhesive Experimental, flew on all space shuttle missions from Return To Flight (STS-114) until the final flight (STS- 135) as a crack repair material for the leading edges and nose cap of the vehicle. NOAX(TM) was patented under U.S. Patents 7,628,878 and 7,888,277.

Riedell, James A.↗

Overview of the Mission Design Reference Trajectory for NASA's Asteroid Redirect Robotic Mission

The National Aeronautics and Space Administration's (NASA's) recently cancelled Asteroid Redirect Mission was proposed to rendezvous with and characterize a 100 m plus class near-Earth asteroid and provide the capability to capture and retrieve a boulder off of the surface of the asteroid and bring the asteroidal material back to cislunar space. Leveraging the best of NASA's science, technology, and human exploration efforts, this mission was originally conceived to support observation campaigns, advanced solar electric propulsion, and NASA's Space Launch System heavy-lift rocket and Orion crew vehicle. The asteroid characterization and capture portion of ARM was referred to as the Asteroid Redirect Robotic Mission (ARRM) and was focused on the robotic capture and then redirection of an asteroidal boulder mass from the reference target, asteroid 2008 EV5, into an orbit near the Moon, referred to as a Near Rectilinear Halo Orbit where astronauts would visit and study it. The purpose of this paper is to document the final reference trajectory of ARRM and the challenges and unique methods employed in the trajectory design of the mission.

low thrust↗

The Badhwar-O'Neill 2020 Model

The Badhwar-O'Neill (BON) model has been used for some time to describe the galactic cosmic ray (GCR) environment encountered in deep space by astronauts and sensitive electronics. The most recent version of the model, BON2014, was calibrated to available measurements to reduce model errors for particles and energies of significance to astronaut exposure. Although subsequent studies showed the model to be reasonably accurate for such applications, modifications to the sunspot number (SSN) classification system and a large number of new high precision measurements suggested the need to develop an improved and more capable model. In this work, the BON2020 model is described. The new model relies on daily integral flux from the Advanced Composition Explorer Cosmic Ray Isotope Spectrometer (ACE/CRIS) to describe solar activity. For time periods not covered by ACE/CRIS, the updated international SSN database is used. Parameters in the new model are calibrated to available data, which includes the new Alpha Magnetic Spectrometer (AMS-02) and Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) high-precision measurements. It is found that the BON2020 model is a significant improvement over BON2014. Systematic errors associated with BON2014 have been removed. The average relative error of the BON2020 model compared to all available measurements is found to be <1%, and BON2020 is found to be within ±15% of a large fraction of the available measurements (26,269 of 27,646 → 95%).

Slaba, Tony C.↗

The Badhwar-O'Neill 2020 Model

The Badhwar-O’Neill (BON) model has been used for some time to describe the galactic cosmic ray (GCR) environment encountered in deep space by astronauts and sensitive electronics. The most recent version of the model, BON2014, was calibrated to available measurements to reduce model errors for particles and energies of significance to astronaut exposure. Although subsequent studies showed the model to be reasonably accurate for such applications, modifications to the sunspot number (SSN) classification system and a large number of new high-precision measurements suggested the need to develop an improved and more capable model. In this work, the BON2020 model is described. The new model relies on daily integral flux from the Advanced Composition Explorer Cosmic Ray Isotope Spectrometer (ACE/CRIS) to describe solar activity. For time periods not covered by ACE/CRIS, the updated international SSN database is used. Parameters in the new model are calibrated to available data, which includes the new Alpha Magnetic Spectrometer (AMS-02) and Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) high-precision measurements. It is found that the BON2020 model is a significant improvement over BON2014. Systematic errors associated with BON2014 have been removed. The average relative error of the BON2020 model compared to all available measurements is found to be <1%, and BON2020 is found to be within +15% of a large fraction of the available measurements (26,269 of 27,646  95%.

T C Slaba↗

Population Accommodation for NASA Spacesuit and Hardware

The goal of this work is to review the population accommodation principles and methodologies NASA Johnson Space Center has developed for the spacesuit, vehicle hardware, and habitats. NASA has defined the target population characteristics in the Human-System Integration Requirements based on the US Army Anthropometric Survey (ANSUR) database. However, the data was screened to select the cases of 30-50 year old subjects, given the historical characteristics of the crew. Further, accommodation ranges were defined for critical body measurements, as NASA aims to accommodate 1st percentile female to 99th percentile male of the crew-like population. The historical truncation thresholds of 5-95th percentiles were not used. This ensured that the accommodation range was not limited and accounted for the current astronaut population. A simulation study also showed that less than 68% of the population may have remained after multiple measurement truncations due to the anthropometry covariance patterns if the narrower range was retained. The ranges were also adjusted for long-term trends of body shape changes as predicted by the US National Health and Nutrition Examination Survey. Overall, the requirements were deemed critical to ensure the fit and accommodation of the new suit and space hardware. The requirements have specifically defined boundary cases for verifications and validations, of which the details have proven useful as standards across the different space programs. The specific use and benefits will be further discussed through case studies at the presentation.

Han Kim↗

Space Adaptation Back Pain: A Retrospective Study

Back pain is frequently reported by astronauts during the early phase of space flight as they adapt to the microgravity environment. However, the epidemiology of space adaptation back pain has not been well defined. The purpose of this retrospective study was to develop a case definition of space adaptation back pain, determine the incidence of space adaptation back pain, and determine the effectiveness of available treatments. Medical records from the Mercury, Apollo, Apollo-Soyuz Test Project (ASTP), Skylab, Mir, International Space Station (ISS), and Shuttle programs were reviewed. All episodes of in-flight back pain that met the criteria for space adaptation back pain were recorded. Pain characteristics, including intensity, location, and duration of the pain were noted. The effectiveness of specific treatments also was recorded. The incidence of space adaptation back pain among astronauts was determined to be 53% (384/722). Most of the affected astronauts reported mild pain (85%). Moderate pain was reported by 11% of the affected astronauts and severe pain was reported by only 4% of the affected astronauts. The most effective treatments were fetal positioning (91% effective) and the use of analgesic medications (85% effective). This retrospective study aids in the development of a case definition of space adaptation back pain and examines the epidemiology of space adaptation back pain. Space adaptation back pain is usually mild and self-limited. However, there is a risk of functional impairment and mission impact in cases of moderate or severe pain that do not respond to currently available treatments. Therefore, the development of preventive measures and more effective treatments should be pursued.

Kerstman, E. L.↗

Jump-Down Performance Alterations after Space Flight

INTRODUCTION: Successful jump performance requires functional coordination of visual, vestibular, and somatosensory systems, which are affected by prolonged exposure to microgravity. Astronauts returning from space flight exhibit impaired ability to coordinate effective landing strategies when jumping from a platform to the ground. This study compares jump strategies used by astronauts before and after flight, changes to those strategies within a test session, and recoveries in jump-down performance parameters across several postflight test sessions. These data were obtained as part of an ongoing interdisciplinary study (Functional Task Test, FTT) designed to evaluate both astronaut postflight functional performance and related physiological changes. METHODS: Seven astronauts from short-duration (Shuttle) and three from long-duration (International Space Station) flights performed 3 two-footed jumps from a platform 30 cm high onto a force plate that measured the ground reaction forces and center-of-pressure displacement from the landings. Neuromuscular activation data were collected from the medial gastrocnemius and anterior tibialis of both legs using surface electromyography electrodes. Two load cells in the platform measured the load exerted by each foot during the takeoff phase of the jump. Data were collected in 2 preflight sessions, on landing day (Shuttle only), and 1, 6, and 30 days after flight. RESULTS: Postural settling time was significantly increased on the first postflight test session and many of the astronauts tested were unable to maintain balance on their first jump landing but recovered by the third jump, showing a learning progression in which performance improvements could be attributed to adjustments in takeoff or landing strategy. Jump strategy changes were evident in reduced air time (time between takeoff and landing) and also in increased asymmetry in foot latencies on takeoff. CONCLUSIONS: The test results revealed significant decrements in astronauts abilities to maintain balance and achieve a postural stability upon landing from a jump early after flight. However, the jump landing adaptation process often begins after the first jump with full recovery of most performance parameters within days after space flight. As expected, performance of ISS astronauts on the first day after flight was similar to that of Shuttle crewmembers on landing day.

Reschke, M. F.↗

The visual standards for the selection and retention of astronauts, part 2

In preparation for the various studies planned for assessing visual capabilities and tasks in order to set vision standards for astronauts, the following pieces of equipment have been assembled and tested: a spectacle obstruction measuring device, a biometric glare susceptibility tester, a variable vergence amplitude testing device, an eye movement recorder, a lunar illumination simulation chamber, a night myopia testing apparatus, and retinal adaption measuring devices.

Allen, M. J.↗

Post-Spaceflight Orthostatic Hypotension Occurs Mostly in Women and is Predicted by Low Vascular Resistance

About 20% of astronauts suffer post-spaceflight presyncope, but the underlying etiology remains elusive. We studied responses to standing in 36 astronauts before and after spaceflight (5- 16 days). Individuals were separated into presyncopal women, presyncopal men, and non-presyncopal men based on their ability to stand for 10 min postflight. Preflight, presyncopal women and presyncopal men had low vascular resistance, with the women having the lowest. Postflight, women experienced significantly higher rates of presyncope (P<0.01) and significantly greater losses of plasma volume than the men (P<0.05). Both presyncopal women and men had lower standing arterial pressure (P<=0.001) and vascular resistance (P<0.05), smaller increases in norepinephrine (P<=0.058) and greater increases in epinephrine (P<=0.058) than nonpresyncopal men. Both presyncopal groups had a strong dependence (P<=0.05) on plasma volume to maintain standing stroke volume. These findings suggest that postflight presyncope is ascribed to a combination of inherently low resistance responses, a strong dependence on volume status, and spaceflight-induced hypoadrenergic responses. In contrast, high vascular resistance and spaceflight-induced hyperadrenergic responses prevent presyncope.

Waters, Wendy W.↗

Gradient Compression Stockings may Prevent Recovery after Bed Rest Deconditioning

Introduction: Astronauts continue to wear a compression garment during and immediately after landing to prevent orthostatic intolerance (OI). We recently developed a custom-fitted, 3-piece garment that consists of thigh-high stockings with biker-style shorts that provides continuous, gradient compression: 55 mmHg at the ankle that decreases to approximately 20 mmHg at the top of the leg and 15 mmHg over the abdomen. This garment has been shown to be effective in preventing symptoms of OI during a short stand test after Space Shuttle missions, but symptoms may persist for several days after a long-duration mission in some astronauts. The purpose of this study was to confirm the effectiveness of wearing these elastic, gradient compression garments during orthostatic testing after 2 weeks of 6 degree head-down tilt bed rest as a model of spaceflight and to determine whether they would impact recovery after bed rest. Methods: Eight (5 treatment, 3 control) of 16 subjects have completed this study to-date. All subjects wore the 3-piece garment from waking until tilt testing (~3 h) as a simulation of the timeline for astronauts on landing day (BR+0). Control subjects removed the garment after the tilt test. Treatment subjects wore the garment for the remainder of the day and wore lower compression thigh-high only garments on the day after bed rest (BR+1). Blood pressure, heart rate, and stroke volume responses to a 15-min 80 degree head-up tilt test were determined before 2 weeks of 6 degree head-down tilt, and on BR+0 and BR+1. Plasma volume (PV) was measured before each of these test sessions. Data are mean SE. Results: Compression garments prevented signs of OI on BR+0; all subjects in both groups completed the full 15-min test. Heart rate responses to tilt were lower on BR+0 than all other test days. Control subjects demonstrated a marginal PV decrease after bed rest, but showed typical recovery the day after bed rest (BR+0: 2.32 plus or minus 0.15 L to BR+1: 2.79 plus or minus 0.15 L). Treatment subjects did not recover PV the day after bed rest (BR+0: 2.61 plus or minus 0.23 L to BR+1: 2.61 plus or minus 0.23 L). Conclusion: Abdomen-high compression garments, which are effective in preventing post-bed rest orthostatic intolerance, may slow recovery of PV. Modified garments with reduced compression may be necessary to prevent prolonging recovery.

Stenger, Michael B.↗