Search NASA⌕ Search

SEARCH · Search NASA

Results for “backscatter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Interpreting radial correlation Doppler reflectometry using gyrokinetic simulations

A linear response, local model for the DBS amplitude applied to gyrokinetic simulations shows that radial correlation Doppler reflectometry measurements (RCDR, Schirmer et al 2007 Plasma Phys. Control. Fusion 49 1019) are not sensitive to the average turbulence radial correlation length, but to a correlation length that depends on the binormal wavenumber $k_{\perp}$ selected by the Doppler backscattering (DBS) signal. Nonlinear gyrokinetic simulations show that the turbulence naturally exhibits a nonseparable power law spectrum in wavenumber space, leading to a power law dependence of the radial correlation length with binormal wavenumber $l_r \sim C k_{\perp}^{-\alpha} (\alpha \approx 1)$ which agrees with the inverse proportionality relationship between the measured $l_r$ and $k_{\perp} $ observed in experiments (Fernández-Marina et al 2014 Nucl. Fusion 54 072001). This new insight indicates that RCDR characterizes the eddy aspect ratio in the perpendicular plane to the magnetic field. It also motivates future use of a nonseparable turbulent spectrum to quantitatively interpret RCDR and potentially other turbulence diagnostics. The radial correlation length is only measurable when the radial resolution at the cutoff location $W_\text n$ satisfies $W_\text n \ll l_r$, while the measurement becomes dominated by $W_\text n$ for $W_\text n \gg l_r$. This suggests that $l_r$ is likely to be inaccessible for electron-scale DBS measurements (${k_{\perp}}{\rho_{\text s}} \gt 1$). The effect of $W_\text n$ on ion-scale radial correlation lengths could be nonnegligible.

radial correlation Doppler reflectometry↗

Correlation of critical current density to quasi-biaxial texture and grain boundary cleanliness in fully dense Bi-2212 wires

The distinctive quasi-biaxial texture of Bi 2 Sr 2 CaCu 2 O x (Bi-2212) plays an important role in enabling high critical current density ($J_c$) in Bi-2212 round wires (RWs). Here we studied three over pressure heat treated wires with $J_c$ varying by a factor of ~10, all being fully dense. Using electron backscatter diffraction, we observed the differences in biaxial texture in these three wires. Transmission electron microscopy also revealed differences in grain boundary (GB) cleanliness and connectivity. These analyses showed that high $J_c$ is unambiguously correlated to the best biaxial texture, which is in turn correlated to slow cooling from the liquid melt into solid Bi-2212. However, at 4.2 K, there is a negligible difference in intragrain pinning in the three wires, suggesting that the $J_c$ variation by a factor of ~10 is primarily due to variable filament and intergrain connectivity. In this work, the principal determinants of intergrain connectivity is the quasi-biaxial texture and GB cleanliness. Overall, $J_c$ optimization of the Bi-2212 RW is a complex multi-variable process, but this study shows that maximizing the biaxial texture quality is an important first step in such an optimization process.

36 MATERIALS SCIENCE↗

Effect of the divertor configuration on the JET edge radial electric field

The role of the divertor configuration and divertor plasma physics on the L–H transition is poorly understood, leading to large uncertainties in predicting the L–H power threshold in future devices. This contribution reports on edge perpendicular plasma flow measurements by Doppler backscattering in JET L–H transition experiments with the outer divertor strike-point at different positions: horizontal target (HT), vertical target (VT), and in the corner configuration (between the HT and VTs). The edge perpendicular flow was found to be significantly affected by changes in the divertor configuration in the region inside the separatrix. Our results do not show evidence for the existence of a critical edge flow shear needed to achieve H-mode for different divertor configurations, with a larger shear observed for the VT configuration. No significant change in the shear flow and in the density fluctuation level is measured preceding the L–H transition in the region just inside the separatrix. The dynamics of the L–H transitions are also influenced by the divertor configuration with divertor oscillations (DOs) observed only in the HT configuration. Interestingly, DOs are associated with marked changes in the edge perpendicular flow around the separatrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancing Cross-Sectional Scanning Electron Microscopy of Perovskite Solar Cells

Organic–inorganic perovskites are an emerging class of photovoltaic materials. Despite achieving power conversion efficiencies surpassing 26%, the challenge of perovskite stability including degradation during exposure to operational conditions such as light, heat, humidity, water, oxygen, and electric fields is well known. Related, perovskite instability has limited high-resolution electron imaging and characterization techniques that can be used for understanding degradation mechanisms. Furthermore, we demonstrate perovskite device cross-section preparation using mechanical polishing in a water-free environment with cryogenic Ar ion milling. Scanning electron microscopy was then used in both backscattered electron and secondary electron imaging modes to obtain information about layer structure, grain aggregate structure, and compositional heterogeneity. Monte Carlo CASINO simulations inform optimum beam conditions and image acquisition parameters and the effects of accelerating voltage, dwell times, and frame averaging for practical image acquisition are reported.

14 SOLAR ENERGY↗

Microstructure-Property Relationships in Epitaxial Cu(In, Ga)Se2 Solar-Cell Absorbers

Epitaxially grown Cu(In,Ga)Se 2 (CIGS) absorber layers were analyzed by various techniques in scanning electron microscopy in order to reveal microstructure-property relationships in these thin films. Owing to their epitaxial nature, these CIGS absorber layers do not contain any grain boundaries, but only anti-phase domains (APDs) and dislocations. By combining electron channeling-contrast imaging, electron backscatter diffraction, and cathodoluminescence (CL), in some cases on identical specimen positions of polished cross-sections of CIGS/Mo/glass stacks, it was possible to correlate the presence and orientations of APDs and dislocations with the lateral distributions of the CL intensity and emission-peak energy. We studied CIGS layers with three different [Ga]/([Ga]+[In]) ratios as well as with and without NaF/KF treatments. Considerable differences between the CIGS layer properties in the microstructure-property relationships were found, depending on the growth parameters. Dislocations in the epitaxial CIGS layers do not tend to exhibit strong CL intensity decreases, which contrasts with the situation in numerous other semiconductor materials.

anti-phase domains↗

Characterization of n-Type Iodine-Doped and Indium-Doped CdTe/Cd-Se-Te Thin Films Fabricated by Close-Spaced Sublimation Epitaxy

In this study, n-type CdTe thin films, specifically iodine-doped CdTe (CdTe:I), indium-doped CdTe (CdTe:In), and indium-doped Cd-Se-Te (CST:In), were synthesized using close-spaced sublimation epitaxy (CSSE). Characterization techniques secondary ion mass spectrometry (SIMS), electron backscatter diffraction (EBSD), Hall-effect measurements, and time-resolved photoluminescence (TRPL) were employed to analyze the chemical, structural, and electronic properties of these materials. The results indicated epitaxial single crystal CSSE films grew on the single crystal substrates, with carrier density ranging from 10^14 - 10^16 cm -3 , and after post-annealing, the minority-carrier lifetimes reach near the radiative limit. Additionally, a preliminary exploration of homojunction structures with an n- type (CdTe:In /CST:In /CdTe:I) /CdTe:P /Cu /Mo configuration was performed. The best device performance was achieved with CdTe:I including CdS aiding in band alignment, resulting in a power conversion efficiency (..eta..) of 2.61% with open circuit voltage (Voc) of 850 mV, fill factor (FF) of 47.8%, and short-circuit current (Jsc) of 6.44 mA/cm 2 . The observed low Jsc and efficiency may be attributed to a buried junction and a poor interface, due to dopant interdiffusion. Consequently, further investigations focusing on interface optimization, diffusion blocking, and reduced recombination through passivation, are crucial to enhancing the efficiency of CSSE CdTe homojunction devices in the future.

cadmium compounds↗

Advancing Temperature Monitoring of the Bottom Anode in a Direct Current Electric Arc Furnace Operations with Distributed Optical Fiber Sensors.

The bottom anode in the Direct Current Electric Arc Furnace (DC EAF) is critical for completing the electrical circuit necessary for sustaining the arc within the furnace. For pin-type bottom anodes, monitoring of the temperature of select pins instrumented with thermocouples is performed to track bottom wear in the EAF and inform the operator when the furnace should be removed from service. Furthermore, this work presents the results from a plant trial using distributed temperature monitoring of bottom anode pins in a 165-ton DC EAF over a two-month service period utilizing two optical fiber sensing techniques: fiber Bragg grating (FBG) and Rayleigh backscattering (RBS). The early detection of temperature anomalies along the length of the anode pin through distributed sensing enhances operational safety, providing a robust alternative to traditional thermocouples.

42 ENGINEERING↗

Characterization of Properties of Laser Powder Bed Fusion 3D-Printed Inconel 718 for Centrifugal Turbomachinery Applications

Here, this paper presents the results of a comprehensive effort to characterize the properties of Inconel 718 produced by a form of laser powder bed fusion (LPBF) additive manufacturing (AM) or 3D-printing, subsequently subjected to hot isostatic pressing (HIP) and heat treatment according to standards F3055-14a and AMS 5663, respectively. Material property data, while broadly available for traditional Inconel 718 presentations (e.g. forgings or castings), is currently lacking for the 3D-printed material. It is expected that while limited in size, the experimental data sets presented provide sufficient information to glean the capability of LPBF Inconel 718. These include: 1) Chemical composition, electron backscatter diffraction (EBSD), and x-ray energy dispersive spectroscopy (XEDS) characterization of 3D-printed material structure; 2) Tensile properties — 0.2% yield stress, ultimate stress, modulus of elasticity, and elongation to failure — based on 108 samples, as functions of temperature and sample print orientation; 3) Creep rupture data including the Larson-Miller parameter, based on 21 samples; and 4) High cycle fatigue data based on 21 samples as a function of temperature. Results are compared to available standards and/or data for forged, cast, and other AM Inconel 718. A key observation of this study, based on the EBSD results, is that while the material appears to approach full recrystallization following heat treatment, there is a detectable fraction of the material that does not fully recrystallize, resulting in a material with mechanical properties (e.g. yield stress, creep rupture) measurably lower than those of forgings, but higher than those of castings.

30 DIRECT ENERGY CONVERSION↗

Data associated with the manuscript “Radiative impact of record-breaking wildfires from integrated ground-based data” collected in Richland, Washington in September 2020

This data package is associated with the publication “Radiative impact of record-breaking wildfires from integrated ground-based data” submitted to Nature Scientific Reports (Kassianov et al., 2024). Data from ground-based measurements of shortwave and spectrally resolved irradiance and aerosol optical depth (AOD) in the visible and near-infrared spectral ranges were assessed to quantify the radiative impact of the September 2020 wildfires that occurred in the Western United States. Data were collected in September 2020 by several ground-based instruments at the Atmospheric Measurements Laboratory (AML) located in Richland, Washington (46.3451, -119.2792). These data include (1) Aerosol Optical Depth (AOD); (2) spectrally resolved and shortwave (SW) irradiances; (3) backscatter profiles; (4) total sky images; and (5) near-surface ambient air temperatures.The data package consists of five sub-directories: (1) “AML_Ceilometer_”; (2)” AML_CSPHOT_”; (3) “AML_MFRSR_irradiances_”; (4) “AML_SW_irradiances_and_Temp_”; (5) “AML_TSI_images_”; and 6 files stored at the directory level, including the readme, file-level metadata file, and data dictionary. The file-level metadata file (the file ending in “_flmd.csv”) lists all files contained in this data package and descriptions for each. The data dictionary (the file ending in “_dd.csv”) describes each tabular column header’s unit, definition, and structure. Below are descriptions of each sub-directory:“AML_Ceilometer_” includes ceilometer data collected at the AML. These files contain the corresponding narratives of data. Details related to the ceilometer data can be found in Morris (2016). “AML_CSPHOT_” includes ascii files with high-temporal resolution (about 10-15 min) AML CSPHOT data and their daily-averaged counterparts. These two files contain the corresponding narratives of data. Details related to the CSPHOT data can be found in Gregory (2011). “AML_MFRSR_irradiances_” includes ascii files with the AML MFRSR-measured diffuse, normal, and total spectrally resolved irradiance. Details related to the MFRSR data can be found in Hodges and Michalsky (2016) and Koontz et al. (2013). “AML_SW_irradiances_+_Temp_” includes near-surface ambient air temperature and SW irradiances, namely direct normal, diffuse hemispherical, and total hemispheric (global), measured at the AML. These files also incorporate the corresponding narratives of data. Details related to the SW irradiances can be found in Andreas et al. (2018). “AML_TSI_images_” includes Total Sky Images (TSIs) collected at the AML. Details related to the TSI data can be found in Morris (2005).

54 ENVIRONMENTAL SCIENCES↗

How Austenitic Is a Martensitic Steel Produced by Laser Powder Bed Fusion? A Cautionary Tale

Accurate phase fraction analysis is an essential element of the microstructural characterization of alloys and often serves as a basis to quantify effects such as heat treatment or mechanical deformation. Additive manufacturing (AM) of metals, due to the intrinsic nonequilibrium solidification and spatial variability, creates additional challenges for the proper quantification of phase fraction. Such challenges are exacerbated when the alloy itself is prone to deformation-induced phase transformation. Using commonly available in-house X-ray diffraction (XRD) and electron backscatter diffraction (EBSD) and less commonly used synchrotron-based high-energy X-ray diffraction, we characterized nitrogen-atomized 17-4 precipitation-hardening martensitic stainless steel, a class of AM alloy that has received broad attention within the AM research community. On the same build, our measurements recovered the entire range of reported values on the austenite phase fractions of as-built AM 17-4 in literature, from ≈100% martensite to ≈100% austenite. Aided by Calphad simulation, our experimental findings established that our as-built AM 17-4 is almost fully austenitic and that in-house XRD and EBSD measurements are subject to significant uncertainties created by the specimen’s surface finish. Hence, measurements made using these techniques must be understood in their correct context. Our results carry significant implications, not only to AM 17-4 but also to AM alloys that are susceptible to deformation-induced structure transformation and suggest that characterizations with less accessible but bulk sensitive techniques such as synchrotron-based high energy X-ray diffraction or neutron diffraction may be required for proper understanding of these materials.

17-4 steel↗

Identification and Quantification of Beta-Emitters in Waste Packages by Segmented Gamma-Scanning - 20114

A commonly applied method for the non-destructive characterization of the radioactive inventory of waste packages (e.g. 200-l drums) is segmented gamma-scanning. The gamma-emitting inventory is identified via their characteristic lines in the measured spectra. The corresponding net peak areas allow for quantification applying appropriate models. The identification and quantification of beta-emitters present in the waste package require further evaluation. While some of them emit gamma-rays, too, which can be used for identification and quantification, pure beta-emitters contribute to the gamma-spectra only by their Bremsstrahlung-spectra. {sup 32}P, {sup 90}Sr and {sup 90}Y are typical representatives of these isotopes. A method is developed for identification and quantification of these pure beta-emitters in radioactive waste packages. Origin of the procedure is the evaluation of the measured gamma-spectrum. After the identification of all lines present in the spectrum (characteristic gamma-lines, single- and double-escape-lines, X-ray-lines, annihilation peak etc.) this information is used together with calibration data of the detection system and further a-priori information like matrix composition, cross-section data from databases etc. to simulate the spectra without the Bremsstrahlung-components by an appropriate method. This may be Monte Carlo simulations or, like in our case, a computer code taking into account mathematical descriptions of the physical effects like photo effect, (multiple) Compton scattering, backscattering etc. and the attenuation effects of the waste matrix. In any case, the resulting spectrum must simulate the real spectrum without its Bremsstrahlung-component as good as possible. Subtracting the simulated from the measured spectrum then results in the Bremsstrahlung-components caused by the beta-emitters. Prior to evaluation, a set of Bremsstrahlung-spectra is calculated and stored for different beta-emitters in different matrices using the Bethe-Heitler equation. This data set can be extended for new conditions, if necessary, and is allocated in a data base for future application. Applying a non-linear optimization using the generalized reduced gradient method for comparing the calculated with the derived Bremsstrahlung-spectra results in the identification of the beta-emitter and a factor, which is proportional to its activity. The proportionality is determined by previous calibration measurements. The application of the method is demonstrated by measurements on a 200-l mock-up drum and a real waste package. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Laser‐Powder Melt Pool Solidification Dynamics and Microstructural Engineering of Ti‐5553 Microlattices

The fine geometric and topological control afforded by additive manufacturing technologies has enabled the manufacture of architected materials across length scales, and enabling tunable mechanical performance as a function of local and global design. Progress has been made to tune the mechanical response of architected materials through geometry, but understanding how the geometry and processing conditions will inform the microstructure remains a challenge due to the rapid solidification in laser powder bed fusion. This study uses in situ X-ray imaging and electron backscatter diffraction microscopy to demonstrate that the melt pool size, microstructure morphology, and elastic strain distribution is influenced by a combination of lattice geometry and laser processing conditions. These results indicate that within larger melt pools the local thermal gradients are sufficient to enable a columnar-to-equiaxed transition across the melt pool. Furthermore, the solidification mechanisms producing these microstructures are examined across the first 5 ms of melting and solidification, described via in situ high-speed X-ray imaging and mirrored via multiphysics simulation.

additive manufacturing↗

La 0.6 Sr 0.4 CoO 3−δ Films Under Deoxygenation: Magnetic And Electronic Transitions Are Apart from The Structural Phase Transition

Abstract Topotactic phase transitions induced by changes in the oxygen vacancy concentration can largely alter the physical properties of complex oxides, including electronic and magnetic phases, while maintaining the structural integrity of the crystal lattice. An oxygen‐vacancy‐induced topotactic phase transition from perovskite (PV) to brownmillerite (BM) is achieved in epitaxial La 0.6 Sr 0.4 CoO 3−δ (LSCO) thin films. Two novel intermediate states with different oxygen content are identified by X‐ray diffraction, which involves a single‐phase reduced PV state and a mixed state of co‐existing PV and BM. The combination of depth‐sensitive polarized neutron reflectometry (PNR) and Rutherford backscattering (RBS) allows a quantitative determination of magnetization and the mean oxygen content in all states, revealing a continuous transition from La 0.6 Sr 0.4 CoO 2.97 to La 0.6 Sr 0.4 CoO 2.5 . BM formation is observed for an LSCO layer with an oxygen content of 2.67, while the magnetic and electronic transition already occurs for a layer with a higher oxygen content of 2.77 (and above) and in the absence of a BM signature. These results demonstrate that the physics of electronic metal‐to‐insulator transition (MIT), magnetic ferromagnet‐to‐non‐ferromagnet transition (FM‐to‐non‐FM), and structural PV‐to‐BM phase transition should be considered within the framework of separate but interrelated processes.

36 MATERIALS SCIENCE↗

Focused Helium Ion Beam for Direct Patterning of Monolayer MoS 2 Nanoribbon Field Effect Devices

The helium ion microscope (HIM) focused ion beam (FIB) has emerged as a powerful tool to directly pattern nanostructures below 10 nm due to its high-resolution capabilities and the inert nature of the ion source. These attributes make HIM FIB particularly interesting for patterning 2D materials such as transition metal dichalcogenides (TMDs) to investigate transport phenomena at the nanoscale. Reported here is the fabrication of MoS 2 nanoribbon devices using HIM FIB-induced etching (FIBIE) with XeF 2 , allowing for reduced ion dose compared to direct sputtering. While patterning is efficacious, the devices exhibit performance degradation with decreasing nanoribbon width due to damage up to 150 nm beyond the patterned edge. Incorporating an hBN encapsulation improves device performance by one order of magnitude, although the lateral extent of damage remains unchanged. The spatial distribution of damage is shown to be determined by the forward- and backscattered ions and electrons, while the hBN encapsulation layer substantially reduces damage from XeF 2 interactions in unexposed regions. Raman and photoluminescence (PL) measurements corroborate these findings, while ion/solid interaction simulations further elucidate the resolution limits imposed by substrate interactions. In conclusion, this work provides critical insights and a practical pathway for utilizing HIM FIBIE in 2D TMD functional device patterning.

MoS 2↗

Accelerating Nature: Induced Atomic Order in Equiatomic FeNi

Abstract The production of locally atomically ordered FeNi (known by its meteoric mineral name, tetrataenite) is confirmed in bulk samples by simultaneous conversion X‐ray and backscattered γ‐ray 57 Fe Mössbauer spectroscopy. Up to 22 volume percent of the tetragonal tetrataenite phase is quantified in samples thermally treated under simultaneous magnetic‐ and stress‐field conditions for a period of 6 weeks, with the remainder identified as the cubic FeNi alloy. In contrast, all precursor samples consist only of the cubic FeNi alloy. Data from the processed alloys are validated using Mössbauer parameters derived from natural meteoritic tetrataenite. The meteoritic tetrataenite exhibits a substantially higher degree of atomic order than do the processed samples, consistent with their low uniaxial magnetocrystalline anisotropy energy of ≈1 kJ·m −3 . These results suggest that targeted refinements to the processing conditions of FeNi will foster greater atomic order and increased magnetocrystalline anisotropy, leading to an enhanced magnetic energy product. These outcomes also suggest that deductions concerning paleomagnetic conditions of the solar system, as derived from meteoritic data, may warrant re‐examination and re‐evaluation. Additionally, this work strengthens the argument that tetrataenite may indeed become a member of the advanced permanent magnet portfolio, helping to meet rapidly escalating green energy imperatives.

36 MATERIALS SCIENCE↗

Local Multimodal Electro-Chemical-Structural Characterization of Solid-Electrolyte Grain Boundaries

Typical models of polycrystalline ionic materials treat the grain boundary properties as single valued, without consideration of the full range of values that define the macroscopically measured average. Here a unique experimental platform suitable for local multimodal characterization of individual grain boundaries in bicrystal fibers is reported. A variation of three orders of magnitude in the grain boundary conductivity of ceria is observed, as measured across six individual bicrystals by both alternating current impedance spectroscopy and direct current (D.C.) linear sweep voltammetry. Nonlinear behavior of the D.C. measurements is consistent with resistance due to a space charge effect. Time-of-flight secondary ion beam spectroscopy reveals a correlation between grain boundary resistance and the concentration of impurities Si, Al, and Ca segregated at the grain boundaries, although the bulk concentrations of these impurities are negligible. Electron backscatter diffraction analysis of the crystal orientations suggests a correlation between the misorientation across the grain boundaries and grain boundary resistance. These correlations point towards a grain boundary resistance that arises from impurity-generated space charge effects and variations in impurity concentration and hence resistivity driven by the energetics of impurity segregation to grain boundaries of differing surface energies.

36 MATERIALS SCIENCE↗

Benefits of using multiple Raman laser wavelengths for characterizing defects in a UO 2 matrix

Abstract Raman spectroscopy is one of the most useful techniques for studying the structure of UO 2 and changes due to specific defects caused by doping, changes in stoichiometry, irradiation, or heating under oxidizing conditions. In this paper, we illustrate several aspects of the application of Raman techniques to the study of UO 2 , including the use of wavelength‐dependent excitation (455, 532, and 785 nm) to assess the effects of doping (Nd, Th, and Zr), ion irradiation, and in situ heating and oxidation (UO 2 to U 3 O 8 ). Additionally, we show examples of how correlative microscopy is possible using electron backscatter diffraction combined with Raman maps of specific vibration bands or of laser‐induced luminescence generated by rare‐earth dopants in the matrix. For each of these applications, we suggest optimal excitation wavelengths that vary depending on the desired data. Blue (455 nm) excitation tends to promote oxidation even at low powers, but because Raman spectra change little with doping, irradiation‐induced changes are easier to observe. Green (532 nm) excitation is optimal for observing electron–phonon resonance effects in UO 2 and offers a good compromise for high‐temperature oxidation experiments, delivering high‐quality spectra for both UO 2 and U 3 O 8 . Infrared (785 nm) excitation is best for observing “defect” bands associated with doping in UO 2 , as changes with irradiation are small. Raman spectroscopy is particularly suited for studying the stability of UO 2 towards oxidation in the presence of dopants simulating fission products, where electron–phonon resonant effects, dopant ion luminescence, and mapping can be used together to investigate structural rearrangement as a function of temperature. These techniques can offer insight into microstructural changes in UO 2 fuels at higher burnups envisioned in future reactors.

42 ENGINEERING↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗