Search NASA⌕ Search

SEARCH · Search NASA

Results for “baseline estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Long-term trends in urban NO 2 concentrations and associated paediatric asthma incidence: estimates from global datasets

Combustion-related nitrogen dioxide (NO 2 ) air pollution is associated with paediatric asthma incidence. We aimed to estimate global surface NO 2 concentrations consistent with the Global Burden of Disease study for 1990-2019 at a 1 km resolution, and the concentrations and attributable paediatric asthma incidence trends in 13 189 cities from 2000 to 2019. We scaled an existing annual average NO 2 concentration dataset for 2010-12 from a land use regression model (based on 5220 NO 2 monitors in 58 countries and land use variables) to other years using NO 2 column densities from satellite and reanalysis datasets. We applied these concentrations in an epidemiologically derived concentration-response function with population and baseline asthma rates to estimate NO 2 -attributable paediatric asthma incidence. We estimated that 1.85 million (95% uncertainty interval [UI] 0.93-2.80 million) new paediatric asthma cases were attributable to NO 2 globally in 2019, two thirds of which occurred in urban areas (1.22 million cases; 95% UI 0.60-1.8 million). The proportion of paediatric asthma incidence that is attributable to NO 2 in urban areas declined from 19.8% (1.22 million attributable cases of 6.14 million total cases) in 2000 to 16.0% (1.24 million attributable cases of 7.73 million total cases) in 2019. Urban attributable fractions dropped in high-income countries (-41%), Latin America and the Caribbean (-16%), central Europe, eastern Europe, and central Asia (-13%), and southeast Asia, east Asia, and Oceania (-6%), and rose in south Asia (+23%), sub-Saharan Africa (+11%), and north Africa and the Middle East (+5%). The contribution of NO 2 concentrations, paediatric population size, and asthma incidence rates to the change in NO 2 -attributable paediatric asthma incidence differed regionally. Despite improvements in some regions, combustion-related NO 2 pollution continues to be an important contributor to paediatric asthma incidence globally, particularly in cities. Mitigating air pollution should be a crucial element of public health strategies for children.

60 APPLIED LIFE SCIENCES↗

The long term stability of VLBI earth orientation measurements

Tectonic motions will, in general, change the orientation as well as the length of baselines used in Very Long Baseline Interferometry (VLBI), and will thus cause slow divergences between earth orientation results obtained with different VLBI networks, as well as between VLBI results and those obtained by satellite laser ranging and lunar laser ranging. Such drifts (on the order of a milliarcsecond/year) are inherently interesting as well as being significant in combinations of orientation results from different sources. The geodetic study of tectonic motions is also closely connected to research into the nature and causes of systematic errors in data from the modern techniques of space geodesy. Both a special coordinate system found to be of use in the analysis of VLBI data and tectonic motion estimates for a VLBI baseline stretching from California to Australia are described.

Eubanks, T. M.↗

Evaluating the Capabilities of Behind-the-Meter Solar-plus-Storage for Providing Backup Power during Long-Duration Power Interruptions [Slides]

The study estimates the performance of behind-the-meter solar PV-plus-energy-storage-systems (PVESS) in providing critical-load or whole-building backup across a wide range of geographies, building types, and power interruption conditions. The study also considers a set of 10 historical long-duration power outage events and evaluates how PVESS could have performed in providing backup power during those specific events. The analysis is the first in what will be a series of studies by Berkeley Lab, in collaboration with the National Renewable Energy Laboratory, on the use of PVESS for backup power. This initial study, which relies on simulated end-use level building loads, solar generation, and storage dispatch, is intended to provide a baseline set of performance estimates and to illustrate key performance drivers.

14 SOLAR ENERGY↗

Experimentally-Derived Phase Function Approximations in Support of the Orbital Debris Program Office

The NASA Orbital Debris Program Office (ODPO) has used various optical assets to acquire photometric data of Earth-orbiting objects to define the orbital debris environment. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA Johnson Space Center emulates illumination conditions seen in space by using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. One of the OMC goals is to improve the size calculation used for optical data by developing an optical-based Size Estimation Model. The current size estimation requires applying a Lambertian phase function, a set albedo value, and range to the observed magnitude. The first step to improving the sampled brightness of laboratory targets is to remove aspect-angle dependencies. Then, the volume of possible object viewing angles is sampled at 21 combinations of azimuth and elevation angles for each solar phase angle. Finally, the acquired images are input into an image processing program that generates approximations for the object’s Bidirectional Reflectance Distribution Function (BRDF) and phase function. The BRDF is a radiometric concept that identifies an object’s material composition by matching a BRDF approximated with photometric data collected by ground-based telescopes with a BRDF generated experimentally from a known object in the laboratory. This paper presents the initial BRDF and phase function approximations for various fragments/targets acquired in the OMC and how the findings will be incorporated into ODPO models. A Lambertian sphere is used as a baseline for initial size estimation calculations and phase function comparisons. Spacecraft materials and fragments from hypervelocity laboratory impact tests are also presented to compare against the current assumed Lambertian phase function used for size estimates. This paper presents the preliminary phase function analysis and plan forward to utilize a laboratory-based phase function to improve the current optical size estimates using BRDF measurements for a large volume of targets composed of various shapes, sizes, and materials.

Hostetler, J.↗

Novel Flow Sheet for Low Energy CO 2 Capture Enabled by Biocatalyst Delivery System

This report documents a preliminary Techno-Economic Assessment (TEA) for processes utilizing Akermin’s second generation biocatalyst delivery system to enhance AKM24, a non- volatile salt solution for CO 2 capture. Biocatalyst enhanced AKM24 offers the potential to reduce the cost of CO 2 capture in flue gas applications due to its improved equilibrium and stoichiometric properties that result in double the absorption capacity relative to previously demonstrated biocatalyst enhanced solvents. The study assumes a new supercritical pulverized coal fired power plant with a net output of 550 MWe after 90% CO 2 capture and uses the June 2011 cost basis (August 2012 update of Bituminous Baseline Study, or BBS). Power plant modeling, capital cost review, and economic calculations were provided by WorleyParsons. Rate-based CO2 capture process modeling and equipment sizing was performed by Akermin using AspenPlus® V8.4, customized to accurately predict thermodynamics, kinetics, and physical properties of the AKM-24 solvent based on available laboratory data. Equipment capital costs were estimated using Aspen Process Economic Analyzer™ which compared well with published baseline cost estimates. Quotes of equipment costs and power consumption for vacuum blower and CO 2 compression equipment were also provided by Man Diesel & Turbo. Three process scenarios were examined for Akermin biocatalyst enhanced solvent systems including: Case-1A: an absorption-desorption system operated with a reboiler pressure of 0.16 bara (60°C); Case-2A: an absorption-desorption system with moderate vacuum assisted regeneration at 0.40 bara (80°C); and finally, Case-2B: a conventional absorption-desorption system with near atmospheric pressure regeneration at 1.07 bara (105°C). The estimated increases in cost of electricity (ICOE) for these cases were $58.1/MWh, $47.3/MWh and $46.4/MWh, respectively. Case 2B had the best results for this analysis achieving an estimated 30% reduction in ICOE relative to the NETL Case 12 (v2) baseline of $66.3/MWh ICOE. Likewise, Case-2B achieved capture costs of $53.0/tCO2 and 65.7/tCO 2 avoided, which equates to 20.2% and 31.4% savings relative to the Case 12 baseline ($66.4/tCO 2 and $95.9/tCO 2 avoided). While Case 2A and 2B have similar results, Case 2A requires further development. Focus on Case 2B is recommended for this project because its cost performance is closest to the DOE goals, and has it has the best potential to achieve a successful demonstration at the next scale.

Reardon, John↗

Fracture toughness evaluation for thin-shell stainless steel weldment

Integrity of spent nuclear fuel (SNF) interim storage canisters are very important to the safety of the back-end nuclear fuel cycle. Stress corrosion cracking (SCC) potential of interim storage canister has been considered as a high priority. Because no post-weld heat treatment was required for forming these canisters, the high tensile residual stress existed within these canister welds. This can change the fracture resistance capacity significantly as well as increase SCC potential. Due to relative thin shell thickness of a canister weldment, the spiral notch torsion test (SNTT) method of small specimen approach was used to estimate the canister weldment fracture toughness. Most SNTT weldment samples fracture initiation sites are at heat-affected zone (HAZ) regions. The estimated fracture toughness $J_Q'$ for the baseline SS304 steel is at 283 kJ/m 2 . The estimated $J_Q'$ for the SS304/308 weld from HAZ and weld specimens are 126 kJ/m 2 and 148.9 kJ/m 2 , respectively.

36 MATERIALS SCIENCE↗

Ammonia Leak Locator Study

The thermal control system of International Space Station Alpha will use liquid ammonia as the heat exchange fluid. It is expected that small leaks (of the order perhaps of one pound of ammonia per day) may develop in the lines transporting the ammonia to the various facilities as well as in the heat exchange equipment. Such leaks must be detected and located before the supply of ammonia becomes critically low. For that reason, NASA-JSC has a program underway to evaluate instruments that can detect and locate ultra-small concentrations of ammonia in a high vacuum environment. To be useful, the instrument must be portable and small enough that an astronaut can easily handle it during extravehicular activity. An additional complication in the design of the instrument is that the environment immediately surrounding ISSA will contain small concentrations of many other gases from venting of onboard experiments as well as from other kinds of leaks. These other vapors include water, cabin air, CO2, CO, argon, N2, and ethylene glycol. Altogether, this local environment might have a pressure of the order of 10(exp -7) to 10(exp -6) torr. Southwest Research Institute (SwRI) was contracted by NASA-JSC to provide support to NASA-JSC and its prime contractors in evaluating ammonia-location instruments and to make a preliminary trade study of the advantages and limitations of potential instruments. The present effort builds upon an earlier SwRI study to evaluate ammonia leak detection instruments [Jolly and Deffenbaugh]. The objectives of the present effort include: (1) Estimate the characteristics of representative ammonia leaks; (2) Evaluate the baseline instrument in the light of the estimated ammonia leak characteristics; (3) Propose alternative instrument concepts; and (4) Conduct a trade study of the proposed alternative concepts and recommend promising instruments. The baseline leak-location instrument selected by NASA-JSC was an ion gauge.

Dodge, Franklin T.↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Optimal Location of Radiation Therapy Centers With Respect to Geographic Access

Purpose: To develop a framework with which to evaluate locations of radiation therapy (RT) centers in a region based on geographic access. Methods and Materials: Patient records were obtained for all external beam radiation therapy started in 2011 for the province of British Columbia, Canada. Two metrics of geographic access were defined. The primary analysis was percentage of patients (coverage) within a 90-minute drive from an RT center (C90), and the secondary analysis was the average drive time (ADT) to an RT center. An integer programming model was developed to determine optimal center locations, catchment areas, and capacity required under different scenarios. Results: Records consisted of 11,096 courses of radiation corresponding to 161,616 fractions. Baseline geographic access was estimated at 102.5 minutes ADT (each way, per fraction) and 75.9% C90. Adding 2 and 3 new centers increased C90 to 88% and 92%, respectively, and decreased ADT by between 43% and 61%, respectively. A scenario in which RT was provided in every potential location that could support at least 1 fully utilized linear accelerator resulted in 35.3 minutes' ADT and 93.6% C90. Conclusions: The proposed framework and model provide a data-driven means to quantitatively evaluate alternative configurations of a regional RT system. Results suggest that the choice of location for future centers can significantly improve geographic access to RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Error estimation for delta VLBI angle and angle rate measurements over baselines between a ground station and a geosynchronous orbiter

Baselines between a ground station and a geosynchronous orbiter provide high resolution Delta VLBI data which is beyond the capability of ground-based interferometry. The effects of possible error sources on such Delta VLBI data for the determination of spacecraft angle and angle rate are investigated. For comparison, the effects on spacecraft-only VLBI are also studied.

Wu, S. C.↗

A study into the loss of lock of the space telescope fine guidance sensor

The results of a study into the loss of lock phenomenon associated with the Space Telescope Fine Guidance Sensor (FGS) are documented. The primary cause of loss of lock has been found to be a combination of cosmic ray spikes and photon noise due to a 14.5 Mv star. The probability of maintaining lock versus time is estimated both for the baseline FGS design and with parameter changes in the FGS firmware which will improve the probability of maintaining lock. The parameters varied are changeable in-flight from the ground and hence do not impact the design of the FGS hardware.

Polites, M. E.↗

Development of laminar flow control wing surface composite structures

The dramatic increases in fuel costs and the potential for periods of limited fuel availability provided the impetus to explore technologies to reduce transport aircraft fuel consumption. NASA sponsored the Aircraft Energy Efficiency (ACEE) program beginning in 1976 to develop technologies to improve fuel efficiency. This report documents the Lockheed-Georgia Company accomplishments under NAS1-16235 LFC Laminar-Flow-Control Wing Panel Structural Design And Development (WSSD); Design, manufacturing, and testing activities. An in-depth preliminary design of the baseline 1993 LFC wing was accomplished. A surface panel using the Lockheed graphite/epoxy integrated LFC wing box structural concept was designed. The concept was shown by analysis to be structurally efficient and cost effective. Critical details of the surface and surface joints were demonstrated by fabricating and testing complex, concept selection specimens. Cost of the baseline LFC aircraft was estimated and compared to the turbulent aircraft. The mission fuel weight was 21.7 percent lower for the LFC aircraft. The calculation shows that the lower fuel costs for LFC offset the higher incremental costs of LFC in less than six months.

Lineberger, L. B.↗

Polar motion, atmospheric angular momentum excitation and earthquakes - Correlations and significance

Equatorial atmospheric angular momentum (AAM) excitation functions and polar motion excitation functions (derived by Kalman filtering Very Long Baseline Interferometry polar motion estimates) are compared with the times of 1984-mid-1988 large earthquakes (magnitude greater than or equal to 7.5). There is a moderate correlation between times of large earthquakes and peaks in polar motion excitation. A strong correlation exists between the times of large earthquakes and large peaks in equatorial AAM amplitude; such a correlation is evident for six out of the eight large earthquakes occurring over the studied time interval. The AAM results indicate potential for the temporal prediction of large/great earthquakes.

Preisig, Joseph R.↗

Project Longshot

Project Longshot presents a preliminary design for an unmanned probe to Alpha Centauri with a planned launch early in the 21st century. A 100-year estimated travel time was baselined for the mission on Space Report, Pioneering the Space Frontier. One of the elements of the Commission's solar and space physics plan is 'a long-life, high-velocity spacecraft to be sent out of the Solar System on a trajectory to the nearest star'. Adequate lead time is included in the scenario to allow the development of several enabling technologies and to ensure that the required space operations infrastructure will be in place.

Source record↗

Observations of the Sea Ice Cover Using Satellite Radar Interferometry

The fringes observed in repeat pass interferograms are expressions of surface relief and relative displacements. The limiting condition in the application of spaceborne radar interferometry to the remote sensing of the sea ice cover is the large magnitude of motion between repeat passes. The translation and rotation of ice floes tend to decorrelate the observations rendering radar interferometry ineffective. In our study, we have located three images in the high Arctic during a period when there was negligible motion between repeat observations. The fringes obtained from these images show a wealth of information about the sea ice cover which is important in atmosphere-ice interactions and sea ice mechanics. These measurements provide the first detailed remote sensing view of the sea ice cover. Ridges can be observed and their heights estimated if the interferometric baseline allows. We have observed ridges with heights greater than 4m. The variability in the phase measurements over an area provides an indication of the large scale roughness. Relative centimetric displacements between rigid ice floes have been observed. We illustrate these observations with examples extracted from the interferograms formed from this set of ERS-1 SAR images.

sea ice cover, satellite, radar, interferometry↗

Impact of Air Traffic Reductions during the COVID-19 Pandemic on Aircraft-induced Clouds and their Radiative Effects

Air travel restrictions due to the novel coronavirus 2019 (COVID-19) pandemic drastically reduced air travel internationally during the spring of 2020. Such an extraordinary disruption of air traffic may have a profound effect on contrail formation that could allow for better quantification and scientific understanding of the radiative impacts of aviation-induced clouds on climate. This investigation synergizes MODIS, CrIS, and GOES-16 satellite analyses with weather analyses, including those from GEOS and MERRA, to compare contrail formation conditions and radiative forcings of linear contrails and thin cirrus detected over the contiguous United States (CONUS) and the North Atlantic for the 2020 air traffic slowdown period with parallel analyses conducted for a baseline period from a previous year with normal air traffic. A consistent analysis system for contrail detection and cloud property retrievals (e.g. optical depth, particle size, and altitude) from satellites, coupled with radiative transfer modeling are applied to characterize and contrast contrail cirrus properties and radiative effects estimated during the pandemic and baseline periods. Temperature and humidity profiles from numerical weather models and hyperspectral infrared measurements are used to estimate the contrail formation potential (CFP) over the study areas in order to help choose the most appropriate baseline period and to account for potential impacts of differences in meteorology on contrail formation and coverage. This study, using NASA satellite data and other assets, is expected to improve our understanding of the relationship between air traffic, contrail cirrus coverage and related impacts in order to better quantify the need for contrail formation mitigation strategies that could reduce aviation effects on climate.

William L Smith↗

Uncertainty Estimation Improves Energy Measurement and Verification Procedures

Implementing energy conservation measures in buildings can reduce energy costs and environmental impacts, but such measures cost money to implement so intelligent investment strategies require the ability to quantify the energy savings by comparing actual energy used to how much energy would have been used in absence of the conservation measures (known as the baseline energy use). Methods exist for predicting baseline energy use, but a limitation of most statistical methods reported in the literature is inadequate quantification of the uncertainty in baseline energy use predictions. However, estimation of uncertainty is essential for weighing the risks of investing in retrofits. Most commercial buildings have, or soon will have, electricity meters capable of providing data at short time intervals. These data provide new opportunities to quantify uncertainty in baseline predictions, and to do so after shorter measurement durations than are traditionally used. In this paper, we show that uncertainty estimation provides greater measurement and verification (M&V) information and helps to overcome some of the difficulties with deciding how much data is needed to develop baseline models and to confirm energy savings. We also show that cross-validation is an effective method for computing uncertainty. In so doing, we extend a simple regression-based method of predicting energy use using short-interval meter data. We demonstrate the methods by predicting energy use in 17 real commercial buildings. We discuss the benefits of uncertainty estimates which can provide actionable decision making information for investing in energy conservation measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗