Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam polarization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Lunar Polar Exploration with Beamed Powered Rovers

Use of a laser to transmit power to a photovoltaic array has been proposed many times, including significant work done at NASA Glenn during the 1990s, but until recently the technology has lagged behind the ambitious requirements. The current NASA objective of lunar polar exploration provides the need, and evolution of higher-power and more efficient lasers provides the opportunity. Exploration of the ice-bearing craters near the lunar poles, where complete absence of sunlight precludes solar power, have been identified as a significant technology challenge for NASA’s future exploration. An approach to solve this is to use a laser to send power from the illuminated crater rim to a photovoltaic receiver on a rover inside the permanently dark region. A conceptual design was done of a prototype laser power system to be included on a proposed flight demonstration of the Kilopower space reactor. For the design, the laser transmitter is mounted on a small rover capable of moving to a location in line of sight of the receiving rover, e.g., on a crater rim with a view into the permanently dark region to be explored. A 250-watt laser diode bar transmits power at 808 nm, using a 10.5 cm optical beam director. The beam is received by a GaAs solar array mounted on the exploring rover, where it is converted into electrical power at ~50% optical to electrical efficiency. For the flight demonstration, 50 meters of laser transmission was required. The design showed a total laser mass of 7.8 kg is capable of producing the beam needed, not including the thermal control system. The demonstration design demonstrates 50-m transmission, but it would be valuable to have longer point-to-point beaming on the moon. Long beam paths require higher coherence than the diode laser bars of the demonstration system. The development of high-efficiency diode-pumped fiber lasers meets this technology need: and diode-pumped fiber lasers using the Er/Yb system can be purchased commercially with overall conversion efficiency of greater than 50% at wavelength 1.06 micrometers. Two technologies for a photovoltaic converter for this wavelength are the InGaAs photovoltaic cell, using technology developed for multi-junction space solar cells, or newly-developed high-quantum efficiency silicon cells. The next step to mature the technology would be a lunar flight demonstration. In the future, this has the potential to enhance and enable future human exploration of the moon, harvesting and utilizing the ice resources of these permanently-shadowed craters.

Geoffrey A Landis↗

Multi-GeV FFA beam transport test at CEBAF

Jefferson National Lab plans an upgrade project to reach 22 GeV high polarization electron beam by using Fixed Field Alternating-gradient (FFA) magnets. The utilization of the FFA magnets for 10-22 GeV beam energy range is unexampled, therefore those magnets need an experimental validation before their full installation to form an arc in the Continuous Electron Beam Accelerator Facility (CEBAF). For this reason, JLAB is also considering the design of an FFA magnet test bench, i.e. a half or full FFA cell, that would be deployed in the current CEBAF in order to serve as the highest energy demonstration for the FFA field uniformity, permanent magnet resiliency with the beam as well as enabling beam optics measurements with the 5-11 GeV range highly polarized beams which closely resembles the full energy range of the 22 GeV upgrade. In this report, we present the status of the planned beamline for the FFA beam transport test at CEBAF.

Accelerator Physics↗

Positrons for Our Future

JLab Users want beams of polarized (and unpolarized) positrons, with beam qualities and modes of operation similar to those provided in the electron beams at CEBAF today [Gra19]. The creation of positrons with a high degree of spin polarization is however very challenging – limited to beta decay, self-polarization in rings, or via e+/e- pair-production, a process requiring a source of polarized gamma rays. At JLab we have a unique source of polarized gamma rays – the bremsstrahlung radiation produced when the spin polarized electron beams of CEBAF interacts with matter – called Polarized Electrons for Polarized Positrons (or PEPPo) [Abb04]. This project sought to extend the PEPPo concept by exploring a possible layout and parameter space for a polarized positron injector at CEBAF based on this approach.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron-Ion Collider Design Status

The Electron-Ion Collider (EIC) is being designed for construction at Brookhaven National Laboratory. Activities have been focused on beam-beam simulations, polarization studies, and beam dynamics, as well as on maturing the layout and lattice design of the constituent accelerators and the interaction region. The latest design advances will be presented.

43 PARTICLE ACCELERATORS↗

ML based control systems for nuclear physics experiments

The Experimental Physics Software and Computing Infrastructure (EPSCI) group at Jefferson Lab is leading the use of machine learning (ML) to enhance control systems in nuclear physics experiments. Collaborating closely with domain experts and data scientists, we have developed an ML-based control system that uses a Gaussian process to dynamically adjust the high voltage of the GlueX Central Drift Chamber. This results in stable detector performance by adapting to environmental changes, thereby reducing the offline calibration effort. Furthermore, we are developing ML-driven systems for optimizing the polarization of photon beams and polarized cryotargets. These systems will maintain the optimal microwave frequency in cryogenic targets and make real-time adjustments to diamond radiators for polarized photon sources, tasks traditionally handled by human operators. By automating these functions, we aim to optimize the polarization, reduce downtime, and minimize human error. This talk will highlight the development of reliable ML-based control systems and the policies to ensure they are both effective and trustworthy.

Jeske, Torri↗

Measurement of the Neutron Electromagnetic Form Factor Ratio at High Momentum Transfer

The inner structure of the nucleon (proton and neutron) remains a topic of great interest in nuclear and particle physics, after many decades of study. For example, understanding the quark-gluon dynamics inside the nucleon would shed light on how 99% of the nucleon mass is created. The neutron electromagnetic form factors, Gn E and Gn M , give important insights into the neutron structure. The Super BigBite Spectrometer (SBS) program at Jefferson Lab (JLab) seeks to extend the form factor measurements for both the proton and the neutron. The neutron electric form actor, Gn E , has been historically difficult to measure due to the short lifetime of the free neutron and the small value of Gn E . The GEn-II experiment is part of the SBS program and seeks to measure Gn E , significantly increasing the high momentum transfer coverage. A newly designed polarized 3He target increased the figure of merit by three times compared to previous measurements. The analysis of this data is especially challenging due to the unprecedented high-rate environment caused by the open nature of the spectrometer with a direct line of sight to the target. This required developing new Gas Electron Multiplier (GEM) particle trackers which can cover large areas demanded by this setup and handle particle rates up to 500 kHz/cm2. Rates this high over a large area is unprecedented in particle tracking systems and came with a number of challenges. Data taken in the SBS program was critical to understanding hardware and software solutions that improved the track reconstruction efficiency to be >97% with a position resolution of 70 ?m. In previous experiments the proton electromagnetic form factors, Gp E and Gp M were measured up to Q2 = 8.5 GeV2 and Q2 = 30 GeV2, respectively, while Gn E has only been measured up to Q2 = 3.4 GeV2. The GEn-II experiment has measured the neutron form factor ratio, Gn E/Gn M, at Q2 values of 2.90, 6.50, and 9.47 GeV2 by scattering a polarized electron beam with a polarized 3He target, used here as an effective polarized neutron target, and measuring the double spin asymmetry of the cross section. Previous Gn E measurements do not extend above Q2 = 3.4 GeV2, and therefore this analysis has extended the world data by almost three times. The background correction is especially difficult at the higher Q2 settings leading to large systematic errors. As very exploratory results from this early analysis of the data, we find for Q2 = 2.90 GeV2, Gn E = 0.0157 ±stat 0.0016 ±sys 0.0011, for Q2 = 6.50 GeV2, Gn E = 0.0067 ±stat 0.0019 ±sys 0.0005, and for Q2 = 9.46 GeV2, Gn E = 0.0046 ±stat 0.0023 ±sys 0.0005. These results are compared to predictions from the Dyson-Schwinger Equations (DSE) model and a Relativistic Constituent Quark Model (RCQM).

Jeffas, Sean↗

Multi-Gas Sensor

A multi-gas sensor is provided which modulates a polarized light beam over a broadband of wavelengths between two alternating orthogonal polarization components. The two orthogonal polarization components of the polarization modulated beam are directed along two distinct optical paths. At least one optical path contains one or more spectral discrimination element, with each spectral discrimination element having spectral absorption features of one or more gases of interest being measured. The two optical paths then intersect, and one orthogonal component of the intersected components is transmitted and the other orthogonal component is reflected. The combined polarization modulated beam is partitioned into one or more smaller spectral regions of interest where one or more gases of interest has an absorption band. The difference in intensity between the two orthogonal polarization components is then determined in each partitioned spectral region of interest as an indication of the spectral emission/absorption of the light beam by the gases of interest in the measurement path. The spectral emission/absorption is indicative of the concentration of the one or more gases of interest in the measurement path. More specifically, one embodiment of the present invention is a gas filter correlation radiometer which comprises a polarizer, a polarization modulator, a polarization beam splitter, a beam combiner, wavelength partitioning element, and detection element. The gases of interest are measured simultaneously and, further, can be measured independently or non-independently. Furthermore, optical or electronic element are provided to balance optical intensities between the two optical paths.

Sachse, Glenn W.↗

Method for Balancing Detector Output to a Desired Level of Balance at a Frequency

A multi-gas sensor is provided which modulates a polarized light beam over a broadband of wavelengths between two alternating orthogonal polarization components. The two orthogonal polarization components of the polarization modulated beam are directed along two distinct optical paths. At least one optical path contains one or more spectral discrimination elements, with each spectral discrimination element having spectral absorption features of one or more gases of interest being measured. The two optical paths then intersect, and one orthogonal component of the intersected components is transmitted and the other orthogonal component is reflected. The combined polarization modulated beam is partitioned into one or more smaller spectral regions of interest where one or more gases of interest has an absorption band. The difference in intensity between the two orthogonal polarization components is then determined in each partitioned spectral region of interest as an indication of the spectral emission/absorption of the light beam by the gases of interest in the measurement path. The spectral emission/absorption is indicative of the concentration of the one or more gases of interest in the measurement path. More specifically, one embodiment of the present invention is a gas filter correlation radiometer which comprises a polarizer, a polarization modulator, a polarization beam splitter, a beam combiner, wavelength partitioning element, and detection element. The gases of interest are measured simultaneously and, further, can be measured independently or non-independently. Furthermore, optical or electronic element are provided to balance optical intensities between the two optical paths.

Sachse, Glenn W.↗

First Measurement Using Elliptically Polarized Photons of the Double-Polarization Observable E for γ p → p π 0 and γ p → n π +

We report the measurement of the helicity asymmetry E for the p π 0 and n π + final states using, for the first time, an elliptically polarized photon beam in combination with a longitudinally polarized target at the Crystal Ball experiment at MAMI. The results agree very well with data that were taken with a circularly polarized photon beam, showing that it is possible to simultaneously measure polarization observables that require linearly (e.g., G ) and circularly polarized photons (e.g., E ) and a longitudinally polarized target. The new data cover a photon energy range 270–1400 MeV for the p π 0 final state (230–842 MeV for the n π + final state) and the full range of pion polar angles, θ , providing the most precise measurement of the observable E . A moment analysis gives a clear observation of the p η cusp in the p π 0 final state. Published by the American Physical Society 2024

Physics↗

Polarization Independent Electro-Optic Modulator

A polarization insensitive electro-optic modulator is constructed by providing a polarization beamsplitter to separate an incoming light beam into two orthogonally plane polarized beams. Each of the polarized beams passes through a separate electro-optic modulator where each beam is modulated by the same data signal. After modulation the beams are combined to yield a modulated beam having modulated components that are orthogonally polarized. Not only is this device insensitive to changes in polarization of the input beam, the final modulated beam can be detected by optical receivers without regard to polarization alignment of the modulated beam and the receiver.

Yao, Xiao-Tian Steve↗

In Situ Generation of High-Energy Spin-Polarized Electrons in a Beam-Driven Plasma Wakefield Accelerator

We report that in situ generation of a high-energy, high-current, spin-polarized electron beam is an outstanding scientific challenge to the development of plasma-based accelerators for high-energy colliders. In this Letter, we show how such a spin-polarized relativistic beam can be produced by ionization injection of electrons of certain atoms with a circularly polarized laser field into a beam-driven plasma wakefield accelerator, providing a much desired one-step solution to this challenge. Using time-dependent Schrödinger equation (TDSE) simulations, we show the propensity rule of spin-dependent ionization of xenon atoms can be reversed in the strong-field multiphoton regime compared with the non-adiabatic tunneling regime, leading to high total spin polarization. Furthermore, three-dimensional particle-in-cell simulations are incorporated with TDSE simulations, providing start-to-end simulations of spin-dependent strong-field ionization of xenon atoms and subsequent trapping, acceleration, and preservation of electron spin polarization in lithium plasma. We show the generation of a high-current (0.8 kA), ultralow-normalized-emittance (~ 37 nm ), and high-energy (2.7 GeV) electron beam within just 11 cm distance, with up to ~31% net spin polarization. Higher current, energy, and net spin-polarization beams are possible by optimizing this concept, thus solving a long-standing problem facing the development of plasma accelerators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interferometer for measurement of optical polarization

Standard two-beam interferometer with polarizers in each beam and an analyzer at the recombined focal point provides greater accuracy and higher resolution than any other known method for measuring variation of polarization within a spectral line and in the surrounding continuum.

Abhyankar, K.↗

AI-Optimized Polarization at Jefferson Lab

The AI-Optimized Polarization project seeks to develop experimental control applications for polarized targets and beams at Jefferson Lab using AI/ML. This paper will focus on two ongoing efforts involving a cryogenic polarized target and a linearly-polarized photon beam. Firstly, cryogenic targets, such as those used in Halls B and C (and approved for Hall D), are complex systems that are sensitive to a number of factors, including the temperature, beam currents, and the microwave and NMR apparatus. Secondly, the Hall D photon beam polarization depends on the optimal orientation of a diamond radiator, which produces coherent bremsstrahlung radiation from the electron beam incident upon it. Manual operation of both systems is tedious and error prone; implementing well-designed, interpretable control systems that incorporate AI is expected to lead to improved real-time polarization. AI optimization of nuclear physics experiments will lead, not just to cost-savings, but also to more efficient and higher-quality data, and this project will help to lay the foundation for future autonomous experiments.

Moran, Patrick [College of William and Mary, Willi↗