At least 217 records · Page 12

Residential photovoltaic module and array requirements study

Design requirements for photovoltaic modules and arrays used in residential applications were identified. Building codes and referenced standards were reviewed for their applicability to residential photovoltaic array installations. Four installation types were identified - integral (replaces roofing), direct (mounted on top of roofing), stand-off (mounted away from roofing), and rack (for flat or low slope roofs, or ground mounted). Installation costs were developed for these mounting types as a function of panel/module size. Studies were performed to identify optimum module shapes and sizes and operating voltage cost drivers. It is concluded that there are no perceived major obstacles to the use of photovoltaic modules in residential arrays. However, there is no applicable building code category for residential photovoltaic modules and arrays and additional work with standards writing organizations is needed to develop residential module and array requirements.

Nearhoof, S. L.↗

DOE Commercial Building Asset Rating: An Application of Centralized Modeling Tools

This paper presents a novel approach used to develop the U.S. Department of Energy (DOE) Commercial Building Asset Rating, which is intended to help building owners better understand the installed system performance and the total energy use. A simplified data collection and energy-modeling method is employed to disaggregate building energy information. Furthermore, the approach outlined will also include a mechanism for identifying energy improvement opportunities. A detailed modeling approach to formulate an Asset Rating would most likely provide the greatest flexibility and accuracy. Such an approach would, however, require a substantial amount of user investment for collecting the energy audit, data and hiring a professional to perform energy modeling and analysis. A simplified model approach requires fewer input combinations, which could reduce opportunities for error and allow an inexperienced user to quickly develop energy models. However, the accuracy of the results is often questionable. To address the above issue, the method presented in this paper separates model inputs into categories based on overall energy impact, difficulty to obtain, and variability among buildings. We outline an approach that will allow great flexibility in terms of how many and which of the different categories of variables must be found to produce an accurate energy model. The approach will allow all key variables to be inferred from some minimum set of variables while at the same time allowing a user to enter many more variables if he or she has reliable values for them. The approach outlined will also provide constant values for some variables and algorithms for finding those which are very difficult to determine in the field. The whole of this approach will reduce modeling time and expertise required while maintaining accuracy and the ability to support the variability and complexity that exist in buildings. Therefore, the goals of facilitating cost-effective investment in energy efficiency and reducing energy use in the commercial building sector are met.

Asset Rating↗

X-ray Sources by Energy Recovered Linacs and Their Needed R&D

In this paper we review the current state of research on energy recovered linacs as drivers for future X-ray sources. For many types of user experiments, such sources may have substantial advantages compared to the workhorse sources of the present: high energy storage rings. Energy recovered linacs need to be improved beyond present experience in both energy and average current to support this application. To build an energy recovered linac based X-ray user facility presents many interesting challenges. We present summaries on the Research and Development (R&D) topics needed for full development of such a source, including the discussion at the Future Light Sources Workshop held in Gaithersberg, Maryland on September 15-17, 2009. A first iteration of an R&D plan is presented that is founded on the notion of building a set of succeedingly larger test accelerators exploring cathode physics, high average current injector physics, and beam recirculation and beam energy recovery at high average current. Our basic conclusion is that a reviewable design of such a source can be developed after an R&D period of reasonably short duration.

43 PARTICLE ACCELERATORS↗

Model-based predictive control of multi-zone commercial building with a lumped building modelling approach

Here this study investigates the applicability of a lumped building modeling approach to model-based predictive control (MPC) to alleviate the complex modeling process of the grey-box multi-zone building model. Based on experimental data, two building models were estimated in this study. The detailed model as a reference case and a lumped model were estimated with decentralized and conventional approaches, respectively. Then, simulations were performed with two boundary conditions, including the comfort bound and electricity cost structure. The performances of the MPC with the detailed and lumped models were analyzed compared to the feedback control. More savings was achieved with a larger comfort bound and more aggressive electricity cost structure. The savings potential of the proposed lumped model approach was not as high as that of the detailed model. However, the proposed method yields good control performance, whose savings was approximately 8.6% over that of feedback control. These results suggest that the proposed method can be used to facilitate MPC implementation in multi-zone building applications.

42 ENGINEERING↗

Quantifying Changes in Building Electricity Use, with Application to Demand Response

We present methods for analyzing commercial and industrial facility 15-minute-interval electric load data. These methods allow building managers to better understand their facility's electricity consumption over time and to compare it to other buildings, helping them to ask the right questions to discover opportunities for demand response, energy efficiency, electricity waste elimination, and peak load management. We primarily focus on demand response. Methods discussed include graphical representations of electric load data, a regression-based electricity load model that uses a time-of-week indicator variable and a piecewise linear and continuous outdoor air temperature dependence, and the definition of various parameters that characterize facility electricity loads and demand response behavior. In the future, these methods could be translated into easy-to-use tools for building managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collaborative WorkBench for Researchers - Work Smarter, Not Harder

It is important to define some commonly used terminology related to collaboration to facilitate clarity in later discussions. We define provisioning as infrastructure capabilities such as computation, storage, data, and tools provided by some agency or similarly trusted institution. Sharing is defined as the process of exchanging data, programs, and knowledge among individuals (often strangers) and groups. Collaboration is a specialized case of sharing. In collaboration, sharing with others (usually known colleagues) is done in pursuit of a common scientific goal or objective. Collaboration entails more dynamic and frequent interactions and can occur at different speeds. Synchronous collaboration occurs in real time such as editing a shared document on the fly, chatting, video conference, etc., and typically requires a peer-to-peer connection. Asynchronous collaboration is episodic in nature based on a push-pull model. Examples of asynchronous collaboration include email exchanges, blogging, repositories, etc. The purpose of a workbench is to provide a customizable framework for different applications. Since the workbench will be common to all the customized tools, it promotes building modular functionality that can be used and reused by multiple tools. The objective of our Collaborative Workbench (CWB) is thus to create such an open and extensible framework for the Earth Science community via a set of plug-ins. Our CWB is based on the Eclipse [2] Integrated Development Environment (IDE), which is designed as a small kernel containing a plug-in loader for hundreds of plug-ins. The kernel itself is an implementation of a known specification to provide an environment for the plug-ins to execute. This design enables modularity, where discrete chunks of functionality can be reused to build new applications. The minimal set of plug-ins necessary to create a client application is called the Eclipse Rich Client Platform (RCP) [3]; The Eclipse RCP also supports thousands of community-contributed plug-ins, making it a popular development platform for many diverse applications including the Science Activity Planner developed at JPL for the Mars rovers [4] and the scientific experiment tool Gumtree [5]. By leveraging the Eclipse RCP to provide an open, extensible framework, a CWB supports customizations via plug-ins to build rich user applications specific for Earth Science. More importantly, CWB plug-ins can be used by existing science tools built off Eclipse such as IDL or PyDev to provide seamless collaboration functionalities.

Ramachandran, Rahul↗

Hygrothermal Simulations of Foundations: Part 1 - Soil Material Properties

Hygrothermal performance of soils coupled to buildings is a complicated process. The computational approach for heat transfer via the ground is well defined (EN-ISO-13370:, 2007) together with simplified methods (Staszczuk, Radon, & Holm). Though the soil moisture transfer is generally ignored, it is proven not negligible (Janssen, Carmeliet, & Hens, 2004). Even though reliable material properties of soils are required to perform realistic hygrothermal calculations of soils coupled to buildings, such material properties have not been well defined in hygrothermal calculations tools. Typical building constructions which are greatly influenced by soils are basements, crawl spaces and slab on grade and reliable hygrothermal performance of such construction are highly requested; as it is ranked within the top 10 Building America Enclosure Research Ideas according to Enclosures STC - Residential Energy Efficiency Stakeholder Meeting, February 29, 2012 Austin, TX. There exists an extensive amount of measurements on soil properties in Soil Science though this information must be gathered as well as adapted to be applicable in Building Science and for hygrothermal simulation purposes. Soil properties are important when analyzing and designing both new building constructions and retrofitting measures, where the outer boundary of the buildings enclosure consists of soil materials. Concerning basement energy retrofits, interior solutions of improving the energy demand has to cooperate with the existing soil properties and must therefore be designed thereafter. In concerns of exterior retrofits, the soil material can be replaced, if needed, with a more suitable filling material, though this approach applies only for basement walls. The soil material beneath the basement floor can naturally not be replaced hence the soil properties of this part of the buildings enclosure still must be taken into consideration. This study is divided into several parts. The intention of the first part is to gather, comprehend and adapt soil properties from soil science. The obtained information must be applicable for Building Science related tasks and validated in hygrothermal calculation tools hence the second part of this study will focus on validation of the implemented soil properties. Basic changes in the software code may be requested as well. Different basement constructions will be created with a hygrothermal calculation tool, WUFI, from which simulations will be compared with existing or on-going measurements. The final outcome of the study is to enable an evaluation of several soil types in several climate zones combined with a number of basement assemblies. The study will define which type of soil together with a certain building construction which is considered most and least reliable in concerns of energy consumption and moisture safety. Further, what influences different soils will have on the total energy loss via the ground and if the performance of a different soils can be measured by a comparison of soil properties solely.

Pallin, Simon B↗

An Experimental Evaluation of HVAC-Grade Carbon-Dioxide Sensors: Part 3, Humidity, Temperature, and Pressure Sensitivity Test Results

This is the third paper in a four-part series reporting on the test and evaluation of typical carbon-dioxide sensors used in building HVAC applications. Fifteen models of NDIR HVAC-grade CO2 sensors were tested and evaluated to determine the humidity, temperature, and pressure sensitivity of the sensors. This paper reports the performance of the sensors at various relative humidity, temperature, and pressure levels common to building HVAC applications and provides a comparison with manufacturer specifications. Among the 15 models tested, eight models have a single-lamp, single-wavelength configuration, four models have a dual-lamp, single-wavelength configuration, and three models have a single-lamp, dual-wavelength configuration. The sensors were tested in a chamber specifically fabricated for this research. A description of the apparatus and the method of test are described in Part 1 (Shrestha and Maxwell 2009). The test result showed a wide variation in humidity, temperature, and pressure sensitivity of CO2 sensors among manufacturers. In some cases, significant variations in sensor performance exist between sensors of the same model. Even the natural variation in relative humidity could significantly vary readings of some CO2 sensor readings. The effects of temperature and pressure variation on NDIR CO2 sensors are unavoidable without an algorithm to compensate for the changes. For the range of temperature and pressure variation in an air-conditioned space, the effect of pressure variation is more significant compared to the effect of temperature variation.

54 ENVIRONMENTAL SCIENCES↗

Aggregate Building Simulator (ABS) Methodology Development, Application, and User Manual

As the relationship between the national building stock and various global energy issues becomes a greater concern, it has been deemed necessary to develop a system of predicting the energy consumption of large groups of buildings. Ideally this system is to take advantage of the most advanced energy simulation software available, be able to execute runs quickly, and provide concise and useful results at a level of detail that meets the users needs without inundating them with data. The resulting methodology that was developed allows the user to quickly develop and execute energy simulations of many buildings simultaneously, taking advantage of parallel processing to greatly reduce total simulation times. The result of these simulations can then be rapidly condensed and presented in a useful and intuitive manner.

99 GENERAL AND MISCELLANEOUS↗

A proposed methodology to reduce heat pump size with integrated thermal energy storage

Thermal energy storage (TES) offers a unique storage solution wherein heat is stored for later use to thermally condition an application. Heat pumps (HPs) move heat from relatively cold to a relatively hot with an input of work. Integrating TES into a HP system adds a third temperature body, and the HP can be selectively coupled to operate between any two: a constant temperature application, a temporally fluctuating ambient temperature, or a constant temperature TES. Since the HP-TES system enables operation under different conditions depending on the pair of temperature bodies, changes in efficiency and capacity can be expected. Thus, TES can shift HP operation to more favorable conditions to deliver heat to the application. Consequently, TES increases the apparent capacity of the HP which might enable a nominally smaller HP to be used effectively. This paper outlines a method by which TES can reduce the size of a HP without sacrificing heat delivered to the application. The method is demonstrated for a building cooling application which realized a reduction in nominal HP size from 3 tons to 2.4 tons.

Hirschey, Jason↗

Experimental natural convection on vertical surfaces for building integrated photovoltaic (BIPV) applications

An experimental study on natural convection in an open channel is carried out in order to investigate the effect of the geometrical configuration of heat sources on the heat transfer behaviour. To this aim, a series of vertical heaters are cooled by natural convection of air flowing between two parallel walls. The objective of the work is to investigate the physical mechanisms which influence the thermal behaviour of a double-skin photovoltaic (PV) facade. This results in a better understanding of the related phenomena and infers useful engineering information for controlling the energy transfers from the environment to the PV surfaces and from the PV surfaces to the building. Furthermore increasing the heat transfer rate from the PV surfaces increases the conversion efficiency of the PV modules since they operate better as their temperature is lower. The test section consists in a double vertical wall, 2 m high, and each wall is constituted by 10 different heating modules 0.2 m high. The heater arrangement simulates, at a reduced scale, the presence of a series of vertical PV modules. The heat flux at the wall ranges from 75 to 200 W/m{sup 2}. In this study, the heated section is 1.6 m in height, preceded by an adiabatic of 0.4 m in height. Different heating configurations are analyzed, including the uniform heating mode and two different configurations of non uniform, alternate heating. The experimental procedure allows the wall surface temperature, local heat transfer coefficient and local and average Nusselt numbers to be inferred. The experimental evidences show that the proper selection of the separating distance and heating configuration can noticeably decrease the surface temperatures and hence enhance the conversion efficiency of PV modules. (author)

14 SOLAR ENERGY↗

An assessment of existing barriers to market adoption of thermal energy storage in buildings based on interviews with stakeholders

The United States administration recently established a goal of reducing greenhouse gas emissions by half below 2005 levels by 2030 and becoming a carbon-neutral economy by 2050. The transition to renewable energy sources may be significantly aided by energy storage. Energy storage could smooth the delivery of variable or intermittent renewable energy sources such as wind, hydro, and sun by storing excess renewable energy when it’s available and delivering it back when renewable energy production is low. Thermal energy storage (TES) is a way that stores thermal energy by heating or cooling a storage medium, which is then used for space heating and cooling, industrial processes, or power generation purposes later. This TES operation could lessen the demand for electricity in both the winter's and the summer's peak hours of electricity. While there are various studies that focus on the advancements and successes of TES technology, less attention is placed on its market adoption. Therefore, the current study undertakes survey-based interview research to understand the existing market barriers hindering TES application in buildings. A series of interviews were performed in this study with individuals from various backgrounds, ranging from homeowners to market specialists who work for TES manufacturers and utility companies. According to the responses obtained during the interviews, they strongly believe that TES has a high potential to contribute to the nation's grid stability and decarbonization goals, however, there are several barriers that prevent homeowners and heat pump manufacturers from investing in TES applications. The current study divided the responses from various background groups into categories to better understand the current challenges for TES applications in buildings. These responses range from payback concerns from homeowners to the need to develop a new metric to represent the benefits of TES from the heat pump and TES manufacturers. The findings from this study can be used by policymakers, utility companies, and manufacturers to better understand present obstacles and develop strategies to overcome them.

Prem Anand Jayaprabha, Jyothis Anand↗

Virtual Design Studio (VDS) - Development of an Integrated Computer Simulation Environment for Performance Based Design of Very-Low Energy and High IEQ Buildings

Executive Summary The objective of this study was to develop a “Virtual Design Studio (VDS)”: a software platform for integrated, coordinated and optimized design of green building systems with low energy consumption, high indoor environmental quality (IEQ), and high level of sustainability. This VDS is intended to assist collaborating architects, engineers and project management team members throughout from the early phases to the detailed building design stages. It can be used to plan design tasks and workflow, and evaluate the potential impacts of various green building strategies on the building performance by using the state of the art simulation tools as well as industrial/professional standards and guidelines for green building system design. Engaged in the development of VDS was a multi-disciplinary research team that included architects, engineers, and software developers. Based on the review and analysis of how existing professional practices in building systems design operate, particularly those used in the U.S., Germany and UK, a generic process for performance-based building design, construction and operation was proposed. It distinguishes the whole process into five distinct stages: Assess, Define, Design, Apply, and Monitoring (ADDAM). The current VDS is focused on the first three stages. The VDS considers building design as a multi-dimensional process, involving multiple design teams, design factors, and design stages. The intersection among these three dimensions defines a specific design task in terms of “who”, “what” and “when”. It also considers building design as a multi-objective process that aims to enhance the five aspects of performance for green building systems: site sustainability, materials and resource efficiency, water utilization efficiency, energy efficiency and impacts to the atmospheric environment, and IEQ. The current VDS development has been limited to energy efficiency and IEQ performance, with particular focus on evaluating thermal performance, air quality and lighting environmental quality because of their strong interaction with the energy performance of buildings. The VDS software framework contains four major functions: 1) Design coordination: It enables users to define tasks using the Input-Process-Output flow approach, which specifies the anticipated activities (i.e., the process), required input and output information, and anticipated interactions with other tasks. It also allows task scheduling to define the work flow, and sharing of the design data and information via the internet. 2) Modeling and simulation: It enables users to perform building simulations to predict the energy consumption and IEQ conditions at any of the design stages by using EnergyPlus and a combined heat, air, moisture and pollutant simulation (CHAMPS) model. A method for co-simulation was developed to allow the use of both models at the same time step for the combined energy and indoor air quality analysis. 3) Results visualization: It enables users to display a 3-D geometric design of the building by reading BIM (building information model) file generated by design software such as SketchUp, and the predicted results of heat, air, moisture, pollutant and light distributions in the building. 4) Performance evaluation: It enables the users to compare the performance of a proposed building design against a reference building that is defined for the same type of buildings under the same climate condition, and predicts the percent of improvements over the minimum requirements specified in ASHRAE Standard 55-2010, 62.1-2010 and 90.1-2010. An approach was developed to estimate the potential impact of a design factor on the whole building performance, and hence can assist the user to identify areas that have most pay back for investment. The VDS software was developed by using C++ with the conventional Model, View and Control (MVC) software architecture. The software has been verified by using a simple 3-zone case building. The application of the VDS concepts and framework for building design and performance analysis has been illustrated by using a medium-sized, five story office building that received LEED Platinum Certification from USGBC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Key elements in building a successful photocomposition applications program

TEXTCOMP, a photocomposition applications program developed by the Technical Information and Documentation Division of the Jet Propulsion Laboratory using the Comp-2 language of Alphanumeric Publication Systems, is described. In Comp-2, each unique block of information such as a paragraph, centered heading, or side heading is termed a 'record'. All commands required for typesetting a record are grouped and identified by a record ID. Once the basic ground rules for typesetting are put into effect by a record ID, changes can be made in texts by means of in-text codes designed to access special characters or perform special operations. The approach used in the design of record ID's and in-text codes for TEXTCOMP to produce a code set structured for maximum usability by non-computer oriented personnel is discussed.

Korbuly, D. K.↗

Demonstration of self-healing barrier films for vacuum insulation panels

This article presents the demonstration of a rapid self-healing system for barrier films of vacuum insulation panels (VIPs). The proposed self-healing films can improve the durability of VIPs by in-situ remediation of film defects. The self-healing concept has seen limited applications in buildings, and the current work is the first proposed application to VIPs. VIPs can attain an order-of-magnitude lower thermal conductivity than traditional foam and fibrous building insulations. The key to the ultra-low thermal conductivity of VIPs is an evacuated core that is fully-encapsulated within impermeable barrier films. Evacuation of the core eliminates the gas conductivity, which is the dominant contributor to heat transfer in traditional insulation materials. Hence, the integrity of the VIP barrier films is critical. The proposed self-healing system can seal accidental cuts and punctures to the barrier films to maintain their impermeability and, hence, the low conductivity of VIPs. Here, the proof-of-principle of a two-part chemical reaction-based self-healing system is presented, including the evaluations of reaction kinetics using chemical-structure analysis and time-dependent viscosity change, and demonstration of self-healing performance via puncture tests in a vacuum pump apparatus. Multiple chemical combinations of epoxies and curing agents were investigated with respect to reaction kinetics and chemical stability. Epon 8111 as an epoxy and poly(ethyelenimine) (PEI) as a curing agent were identified as the optimum chemicals with a curing time of 22 s as evaluated by an agitating stirrer experiment. 1H nuclear magnetic resonance (NMR) spectra analysis identified the curing reaction occurring mainly via the Michael amine-acrylate addition. The measured time-dependent viscosity change of diluted Epon 8111 and PEI solutions agreed well with a gelation model of typical epoxy curing kinetics, which predicted a very fast reaction rate for the undiluted chemicals. Lastly, puncture tests of small-scale film specimens containing Epon 8111 and PEI in a vacuum pump system demonstrated that the self-healing reaction happens very rapidly and the healed films maintain the system vacuum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗