Search NASA⌕ Search

SEARCH · Search NASA

Results for “cables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Chemical-Sensing Cables Detect Potential Threats

Intelligent Optical Systems Inc. (IOS) completed Phase I and II Small Business Innovation Research (SBIR) contracts with NASA's Langley Research Center to develop moisture- and pH-sensitive sensors to detect corrosion or pre-corrosive conditions, warning of potentially dangerous conditions before significant structural damage occurs. This new type of sensor uses a specially manufactured optical fiber whose entire length is chemically sensitive, changing color in response to contact with its target, and demonstrated to detect potentially corrosive moisture incursions to within 2 cm. After completing the work with NASA, the company received a Defense Advanced Research Projects Agency (DARPA) Phase III SBIR to develop the sensors further for detecting chemical warfare agents, for which they proved just as successful. The company then worked with the U.S. Department of Defense (DoD) to fine tune the sensors for detecting potential threats, such as toxic industrial compounds and nerve agents. In addition to the work with government agencies, Intelligent Optical Systems has sold the chemically sensitive fiber optic cables to major automotive and aerospace companies, who are finding a variety of uses for the devices. Marketed under the brand name Distributed Intrinsic Chemical Agent Sensing and Transmission (DICAST), these unique continuous-cable fiber optic chemical sensors can serve in a variety of applications: Corrosive-condition monitoring, aiding experimentation with nontraditional power sources, as an economical means of detecting chemical release in large facilities, as an inexpensive "alarm" systems to alert the user to a change in the chemical environment anywhere along the cable, or in distance-resolved optical time domain reflectometry systems to provide detailed profiles of chemical concentration versus length.

Source record↗

Fiber Optic Cable Thermal Preparation to Ensure Stable Operation

Fiber optic cables are widely used in modern systems that must provide stable operation during exposure to changing environmental conditions. For example, a fiber optic cable on a satellite may have to reliably function over a temperature range of -50 C up to 125 C. While the system requirements for a particular application will dictate the exact method by which the fibers should be prepared, this work will examine multiple ruggedized fibers prepared in different fashions and subjected to thermal qualification testing. The data show that if properly conditioned the fiber cables can provide stable operation, but if done incorrectly, they will have large fluctuations in transmission.

Thoames Jr, William J.↗

Bulk Current Injection Testing of Cable Noise Reduction Techniques, 50 kHz to 400 MHz

This paper presents empirical results of cable noise reduction techniques as demonstrated using bulk current injection (BCI) techniques with radiated fields from 50 kHz - 400 MHz. It is a follow up to the two-part paper series presented at the Asia Pacific EMC Conference that focused on TEM cell signal injection. This paper discusses the effects of cable types, shield connections, and chassis connections on cable noise. For each topic, well established theories are compared with data from a real-world physical system.

Bradley, Arthur T.↗

Wire and Cable Cold Bending Test

One of the factors in assessing the applicability of wire or cable on the lunar surface is its flexibility under extreme cold conditions. Existing wire specifications did not address their mechanical behavior under cold, cryogenic temperature conditions. Therefore tests were performed to provide this information. To assess this characteristic 35 different insulated wire and cable pieces were cold soaked in liquid nitrogen. The segments were then subjected to bending and the force was recorded. Any failure of the insulation or jacketing was also documented for each sample tested. The bending force tests were performed at room temperature to provide a comparison to the change in force needed to bend the samples due to the low temperature conditions. The results from the bending tests were plotted and showed how various types of insulated wire and cable responded to bending under cold conditions. These results were then used to estimate the torque needed to unroll the wire under these low temperature conditions.

Colozza, Anthony↗

Evaluation of Cable Harness Post-Installation Testing

The Cable Harness Post-Installation Testing Report was written in response to an action issued by the Ares Project Control Board (PCB). The action for the Ares I Avionics & Software Chief Engineer and the Avionics Integration and Vehicle Systems Test Work Breakdown Structure (WBS) Manager in the Vehicle Integration Office was to develop a set of guidelines for electrical cable harnesses. Research showed that post-installation tests have been done since the Apollo era. For Ares I-X, the requirement for post-installation testing was removed to make it consistent with the avionics processes used on the Atlas V expendable launch vehicle. Further research for the report involved surveying government and private sector launch vehicle developers, military and commercial aircraft, spacecraft developers, and harness vendors. Responses indicated crewed launch vehicles and military aircraft perform post-installation tests. Key findings in the report were as follows: Test requirements identify damage, human-rated vehicles should be tested despite the identification of statistically few failures, data does not support the claim that post-installation testing damages the harness insulation system, and proper planning can reduce overhead associated with testing. The primary recommendation of the report is for the Ares projects to retain the practice of post-fabrication and post-installation cable harness testing.

King, M. S.↗

Shielded-Twisted-Pair Cable Model for Chafe Fault Detection via Time-Domain Reflectometry

This report details the development, verification, and validation of an innovative physics-based model of electrical signal propagation through shielded-twisted-pair cable, which is commonly found on aircraft and offers an ideal proving ground for detection of small holes in a shield well before catastrophic damage occurs. The accuracy of this model is verified through numerical electromagnetic simulations using a commercially available software tool. The model is shown to be representative of more realistic (analytically intractable) cable configurations as well. A probabilistic framework is developed for validating the model accuracy with reflectometry data obtained from real aircraft-grade cables chafed in the laboratory.

Schuet, Stefan R.↗

Static Dissipative Cable Ties, Such as for Radiation Belt Storm Probes

Methods of cyclically heating and cooling an article formed of a static dissipative ETFE resin, such as to reduce an electrical resistivity and/or to increase a tensile strength of the article, and methods of irradiating an article formed of a static dissipative ETFE resin, such as to increase a tensile strength of the article. Also disclosed herein are articles formed of a static dissipative ETFE resin, and processed in accordance with methods disclosed herein. Such an article may include, for example and without limitation, a cable strap to wrap, support, and/or secure one or more wires or cables, such as a cable tie.

Langley, Patrick T.↗

High-Density Superconducting Cables for Advanced ACTPol

Advanced ACTPol (AdvACT) is an upcoming Atacama Cosmology Telescope (ACT) receiver upgrade, scheduled to deploy in 2016, that will allow measure- ment of the cosmic microwave background polarization and temperature to the highest precision yet with ACT. The AdvACT increase in sensitivity is partly provided by an increase in the number of transition-edge sensors (TESes) per array by up to a factor of two over the current ACTPol receiver detector arrays. The high-density AdvACT TES arrays require 70 μ m pitch superconducting flexible cables (flex) to connect the detec- tor wafer to the first-stage readout electronics. Here, we present the flex fabrication process and test results. For the flex wiring layer, we use a 400-nm-thick sputtered alu- minum film. In the center of the cable, the wiring is supported by a polyimide substrate, which smoothly transitions to a bare (uncoated with polyimide) silicon substrate at the ends of the cable for a robust wedge wire-bonding interface. Tests on the first batch of flex made for the first AdvACT array show that the flex will meet the requirements for AdvACT, with a superconducting critical current above 1 mA at 500 mK, resilience to mechanical and cryogenic stress, and a room temperature yield of 97%.

transition-edge sensors (TESes)↗

Structural Analysis Findings of Open Spelter Socket Cable Terminations

A three-dimensional nonlinear finite element model of a representative open spelter socket termination was developed to examine the underlying mechanics of load transfer from a structural cable through the termination, the sensitivity of the joint design to wire brooming, zinc material nonlinearity, contact friction between the zinc and socket, voids within the zinc, and, finally, the effects of repeated loading on the joint. Primary factors affecting open spelter socket design are cast zinc plastic flow, depth of zinc slug seating, and quality of wire brooming. Zinc plasticity and proper brooming allows for efficient load transfer by developing confining pressure on the broomed wires in the narrow part of the socket, which keep the wires from pulling out of the zinc and shift failure to occur outside the socket. Highest wire stresses in the cable occur in the outer ring adjacent to the termination. While industry use of stay cables are typically designed to carry less than half the rated breaking force in aggregate, the constituent stresses within the zinc and the wires have the potential to exceed their respective allowable in operation and should be evaluated for fatigue- and creep-critical applications.

Pavel Babuska↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Power systems for ocean regional cabled observatories

Development of power systems is the most challenging technical issue in the design of ocean regional cabled observatories. ARENA and NEPTUNE are two ocean regional cabled observatory networks with aims that are at least broadly similar. Yet the two designs are quite different in detail. This paper outlines the both systems and explores the reasons for the divergence of design, and shows that it arose because of differences in the priority of requirements.

cabled subsea observatory↗

Dynamic analysis of fully constrained Cable-Driven Parallel Robots for automated prefabricated component installation

This paper presents a dynamic analysis and validation framework to assess a fully constrained six-anchor Cable-Driven Parallel Robot (CDPR) for automated installation of prefabricated facade components. Compared with conventional eight-anchor systems, the six-anchor configuration simplifies setup and reduces cost, but it also reduces control authority, shrinks the wrench-feasible workspace, and tightens orientation limits. Consequently, it is unclear a priori whether dynamically feasible trajectories exist to move the end effector from pickup to the facade. A constrained trajectory optimization is formulated to enforce the system dynamics, cable-tension bounds, and pose/velocity limits, and the framework is evaluated in simulation at three levels: (i) an idealized reference model, (ii) a lab-scale prototype model incorporating measured anchor misalignments and identified damping, and (iii) a full-scale three-story building model with load decomposition for structural feasibility checks. Across these scenarios, the analysis shows that optimal, constraint-satisfying trajectories exist that move the end effector from pickup to installation while maintaining a near-plumb, level orientation at the final pose. Collectively, this multi-scale dynamic analysis and validation framework supports the deployment readiness of the six-anchor CDPR and provides a prototype-based sensitivity case study of how measured anchor placement deviations affect feasibility.

CDPR↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Characterizing Microwave Losses in Superconducting Coaxial Cables for Quantum Systems

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present a detailed characterization of microwave losses in commercially available superconducting cables and discuss how material characterization techniques can be useful for understanding their microscopic origin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CABLE Stage 3 – Ultra‐High Strength/Highly Conductive Al Alloys

This work is to be conducted in support of the CABLE Conductor Manufacturing Prize Program awarded by NREL. The intent is to connect competitor teams with national laboratories that can help accelerate the development of innovative solutions and products. Teams who receive CABLE Prize awards are eligible to utilize vouchers at national laboratories to advance their ideas. NanoAL LLC has been awarded a voucher to utilize at Ames National Laboratory. Ames National Laboratory will perform a scale‐up trial of Nano 6000‐T9 to evaluate and optimize the heat treatment and other processing variables to validate the lab‐scale work done at NanoAL. The final processing schedule will be used to fabricate the submission samples for the Stage 3 contest. All work will be supported by mechanical and electrical conductivity testing be performed by Ames.

36 MATERIALS SCIENCE↗

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY↗