Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Low-background air-infrared telescope for balloon-borne infrared astronomy

The design and performance of a far-infrared telescope are discussed. The instrument is twenty centimeters in diameter and has excellent operating characteristics at 100 microns. The principal features of the telescope are summarized. A diagram of the system is provided. The telescope completed two sucessful balloon flights in which the planets Mars and Saturn were used as calibration sources. Observations were made of the H2 regions W 3, Orion A, NGC 2024, and the bright infrared galaxy M 82.

Low, F. J.↗

The X-band low noise antenna measurement cone

An X-band low-noise receiving cone with 17-MHz instantaneous bandwidth was built to evaluate the 26-m antenna at the Venus Station (DSS 13), Goldstone, California, at X-band frequencies, and also to provide a means for precise radio source calibrations in this frequency range. These measurments are necessary to provide more accurate antenna gain performance calibrations for the 64-m antenna subnet. The zenith system temperatures with the cone on the ground and on the antenna are 17.5 and 20.8 K, respectively.

Reid, M. S.↗

DSN research and technology support

The activities of the Venus Station (DSS 13) and the Microwave Test Facility (MTF) during the period April 19 through June 13, 1976, are discussed and progress noted. Continuing reliability testing and computer program refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine observations of 17 pulsars. Radar observations of a geostationary satellite are reported, along with the routine automatic testing of the stability of the DSS 13 maser-receiving system. Additional testing of thermal characteristics of semiflexible coaxial cables is reported, along with phase stabilization measurements thereon. Routine support of the planetary radio astronomy experiment, with 43.25 hours of observations of Jupiter and various radio calibration sources, is reported, along with 18.75 hours of differential VLBI observations in conjunction with Australia, DSS 43. Modifications of the clock synchronization winterization system are reported, along with a discussion of the activities of the DSN High-Power Transmitter Maintenance Facility.

Jackson, E. B.↗

Imaging Proportional X-ray Counter for HEAO

The HEAO-B Imaging Proportional Counter (IPC) is an X-ray imaging instrument designed for use in the High Energy Astronomy Observatory - Mission B (HEAO-B) X-ray Telescope. It measures the spatial location of individual X-ray photons by the risetime method and energy of photons by pulse height analysis. The IPC can locate photons in the energy range 0.2 to 4 keV to within 1 mm and provides 5 bits of energy level information. Each measured X-ray event is also time tagged with 7 bits of temporal data. The IPC also includes an in-flight-calibration source and uses a gas control system that maintains the counter gas density constant to an accuracy of 0.25 percent.

Humphrey, A.↗

Far infrared spectrophotometry of Jupiter and Saturn

Infrared spectral measurements of Mars, Jupiter, and Saturn were obtained from 100 to 470 kaysers and, by taking Mars as a calibration source, brightness temperatures of Jupiter and Saturn were determined with approximately 5 kayser resolution. Internal luminosities were determined from the data and are reported to be approximately 8 times 10 to the minus tenth power of the sun's luminosity for Jupiter and approximately 3.6 times 10 to the minus tenth power of the sun's luminosity for Saturn. Comparison of data with spectra predicted by models suggests the need for an opacity source in addition to gaseous hydrogen and ammonia to help explain Jupiter's observed spectrum in the vicinity of 250 kaysers.

Erickson, E. F.↗

Very high resolution observations of SS433 at 10.65 GHz

Observations of SS433 made on June 12, 1979, from West Germany, Massachusetts, and West Virginia are discussed. It is noted that SS433 did not show fringes on any baseline although all the calibration sources were seen at their expected strengths. The measured total flux density of SS433 was found to be approximately 0.5 Jy, consistent with previous observations. The source was observed by on-offs at each telescope, which indicates that they were all pointed properly during the observations. The absence of fringes is not attributed to poor observing conditions or instrumental difficulties. It is concluded that if all the 10.65 GHz radiation emanates from a single component, then that component is at least 0.005 arcsec (approximately 10 to the 14th cm) in size. The measurements made on more sensitive intercontinental baselines indicate that there is no component of SS433 smaller than 0.001 arcsec emitting 10.65 GHz radiation above a level of 50 mJy.

Geldzahler, B. J.↗

Multispectral Linear Array (MLA) science and technology program

A Goddard Space Flight Center program of science studies and technology development to provide the basis for future earth observation sensors employing multispectral linear array (MLA) technology is described. Establishment of MLA performance parameters and performance modeling make up the primary science activities. Critical technologies being developed include: short-wave infrared (SWIR) detector arrays, visible/and near infrared detector arrays, and passive cryogenic coolers. Supporting activities include: test and field instrument development, focal plane research and assessment laboratory, system simulation laboratory, calibration sources and techniques, optics, and thermal infrared arrays.

Barnes, W. L.↗

Study of proton and neutron activation of metal samples in low Earth orbit

Progress in the following activities has been made: the analysis of the gamma ray spectra taken from samples flown in Spacelab 2; the search for and review of neutron and proton activation cross sections needed to analyze the results of the Long Duration Exposure Facility (LDEF) activation measurements; the consideration given to data analysis of the LDEF and Spacelab 2 samples; the plan to measure relevant cross sections with nuclear accelerator measurements; and the preparation of an extended gamma ray calibration sources continues through planning and direct measurement of gamma ray efficiency for a Ge(Li) as a function of position along the surface of the detector housing.

Laird, C. E.↗

Study of proton and neutron activation of metal samples in low Earth orbit

The analysis of the gamma-ray spectra taken from samples flown in Spacelab 1; the search for and review of neutron and proton activation cross-sections needed to analyze the results of the Long Duration Exposure Facility (LDEF) activation measurements; additional calculations of neutron induced activation for the LDEF samples; the data analysis plan for the LDEF and Spacelab 2 samples; the measurement of relevant cross-sections with activation of samples of V, Co, In, and Ta at the Indiana University Cyclotron Facility; and the preparation of an extended gamma-ray calibration source through the development of a proper technique to accurately deposit equal quantities of radioactive material onto a large number of point on the source are discussed.

Laird, C. E.↗

Microwave blackbodies for spaceborne receivers

The properties of microwave blackbody targets are explained as they apply to the calibration of spaceborne receivers. Also described are several practicable, blackbody targets used to test and calibrate receivers in the laboratory and in the thermal vacuum chamber. Problems with the precision and the accuracy of blackbody targets, and blackbody target design concepts that overcome some of the accuracy limitations present in existing target designs, are presented. The principle of the Brewster angle blackbody target is described where the blackbody is applied as a fixed-temperature test target in the laboratory and as a variable-temperature target in the thermal vacuum chamber. The reflectivity of a Brewster angle target is measured in the laboratory. From this measurement, the emissivity of the target is calculated. Radiatively cooled thermal suspensions are discussed as the coolants of blackbody targets and waveguide terminations that function as calibration devices in spaceborne receivers. Examples are given for the design of radiatively cooled thermal suspensions. Corrugated-horn antennas used to observe the cosmic background and to provide a cold-calibration source for spaceborne receivers are described.

Stacey, J. M.↗

Photofraction of a 5 cm x 2 cm BGO scintillator

The photofraction of a 5.1 cm x 2.0 cm bismuth germanate (BGO) scintillator was measured over a gamma-ray energy range of 0.2 to 6.1 MeV. Several methods, used to minimize the effect of room scattering on the measurement, are discussed. These include a gamma-gamma coincidence technique, a beta-gamma coincidence technique, and the use of sources calibrated with a standard 7.6 cm x 7.6 cm sodium iodide scintillator.

Dunphy, P. P.↗

VLA observations of rapid 6 cm flux variations in alpha Ori

The red supergiant star alpha Ori was monitored with the Very Large Array (VLA). Thirteen observations at 6 cm show stochastic variations, at the 30 to 40 percent level, with no long term trend. All data was clipped and tapered in AIPS to minimize differences between VLA arrays. The calibration source varied by less than 10 percent over the same interval. The VLA observations of alpha Ori were continued, as well as alpha Her and alpha Sco, at both 2 and 6 cm, to confirm this result and search for long term trends. The stochastic 6 cm flux behavior, with 30 to 40 percent changes on all timescales from the shortest interval of 10 days to the longest, seems at odds with the 400 day periodic variations in U-band photometry and Mg II UV fluxes reported by Dupree, et al. The observed 6 cm flux was 25 percent below the 6 cm flux reported earlier this decade. Several models for the outer atmosphere of alpha Ori place the 6 cm optical depth unity location at several stellar radii above the optical photosphere. The rapid, stochastic variations reported are difficult to reconcile with almost any global process, such as pulsation, Alfven waves or periastron passage.

Bookbinder, J. A.↗

Supernova 1987A - A radiosphere resolved with VLBI five days after the neutrino burst

The results of VLBI observations of SN1987A are reported. No emission from the supernova above a level of about 20 percent of the supernova's total flux density was detected, although signals were detected from two calibrator sources with amplitudes roughly equal to those determined in earlier VLBI observations. It is inferred that the supernova's radiosphere was resolved, and a lower bound on the radiosphere's radius of 2.2 mas is estimated from an epoch 5.2 days after the neutrino burst. Given the photometric data from the supernova, a distance to the LMC of 50 + or - 5 kpc, and an apparent expansion velocity that varied systematically with time from 18,000-16,000 km/s, as estimated from the blue-shifted H-alpha absorption lines on the days preceding the observations, it is concluded that 5.2 days after the neutrino burst the supernova's radiosphere was at least 2.5 times larger than the inferred blackbody photosphere, and at least as large as the H-alpha line-forming region.

Jauncey, D. L.↗

Development of the CLAES instrument aperture door system

The design, assembly, and test processes followed in developing a space-qualified aperture door system are described. A blackbody calibration source is mounted inside the door, requiring the assembly to open and close a minimum of 150 cycles for instrument recalibration. Within the door system are four separate mechanisms, three of which are redundant; a pyro launch latch, a hinge bearing assembly, and a pair of pivot mechanisms. Decoupling devices within the pivot mechanisms allow an active drive unit to automatically overdrive a failed drive unit. The door is also stowable for possible Shuttle retrieval and re-entry. Illustrations and photographs of the flight hardware help acquaint the reader with the design. The aim is to pass on lessons learned in all phases of developing this spaceflight mechanism.

Stubbs, D. M.↗

Cryogenic Limb Array Etalon Spectrometer (CLAES) - Instrument overview

The design and capabilities of CLAES are described. The CLAES is an instrument on NASA's Upper Atmosphere Research Satellite (UARS) and measures the global concentrations of stratospheric species and temperature over the altitude range 10-60 km. Consideration is given to the motorized limb acquisition and adjustment mirror, solid cryogen cooler, optical system, electronics subsystems, cryostat, and IR calibration source. Diagrams of the CLAES and UARS are provided.

Burriesci, Larry↗

Radio emission in peculiar galaxies

During the last decades a number of surveys of peculiar galaxies have been carried out and accurate positions become available. Since peculiarities are a possible evidence of radio emission (Wright, 1974; Sulentic, 1976; Stocke et al., 1978), the authors selected a sample of 24 peculiar galaxies with optical jet-like features or extensions in different optical catalogues, mainly the Catalogue of Southern Peculiar Galaxies and Associations (Arp and Madore, 1987) and the ESO/Uppsala Survey of the ESO(B) Atlas (Lauberts, 1982) for observation at the radio continuum frequency of 22 GHz. The sample is listed in a table. Sol (1987) studied this sample and concluded that the majority of the jet-like features seem to admit an explanation in terms of interactive galaxies with bridges and/or tails due to tidal effects. Only in a few cases do the jets seem to be possibly linked to some nuclear activity of the host galaxy. The observations were made with the 13.7m-radome enclosed Itapetinga Radiotelescope (HPBW of 4.3 arcmin), in Brazil. The receiver was a 1 GHz d.s.b. super-heterodine mixer operated in total-power mode, with a system temperature of approximately 800 K. The observational technique consisted in scans in right ascention, centralized in the optical position of the galaxy. The amplitude of one scan was 43 arcmin, and its duration time was 20 seconds. The integration time was at least 2 hours (12 ten-minute observations) and the sensibility limit adopted was an antenna temperature greater than 3 times the r.m.s. error of the baseline determination. Virgo A was used as the calibrator source. Three galaxies were detected for the first time as radio sources and four other known galaxies at low frequencies had their flux densities measured at 22 GHz. The results for these sources are presented.

Demellorabaca, Dulia F.↗

Measurements of induced radioactivity in some LDEF samples

Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 pcts. at 1332 keV. Detector efficiencies as a function of energy and corrections for self absorption in the samples were determined with calibrated sources, unactivated control samples, and calculations. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum samples, Na-22 and Be-7 were seen. Other results are presented.

Moss, C. E.↗

Measurements of induced radioactivity in some LDEF samples

Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 percent at 1332 keV. Detector efficiencies as a function of energy and corrections for self-absorption in the samples were determined with calibrated sources and unactivated control samples. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum and titanium samples, Na-22 was detected. Other results are presented.

Moss, C. E.↗