Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

LIPA: Lunar Ice Perception Algorithm

Introduction: The highest concentration of Lu-nar water-ice stores exists within the Permanently Shadowed Regions (PSRs) of the Lunar South Pole [1-3]. As such, the ability to locate in situ water-ice stores in an accurate, systematic, and safe manner will prove vital for future Lunar activities which rely on hydrogen-based resources. Here we show how the strong absorptive properties of ice can be exploited so that surface ice located in PSRs can be easily differentiated from the surrounding frozen regolith. Testbeds which simulate an icy lunar landscape were created and then systematically imaged using a mid-wave infrared (MWIR) camera system. Testbeds were imaged under two filter modes (1) high-absorption (high-abs) mode: whereby imagery captured were confined to a single central wave-length (CWL) of 3.15 ± 0.03 μm and (2) low-absorption (low-abs) mode: whereby imagery cap-tured were confined to a single CWL of 3.80 ± 0.04 μm (Figure 1). High- and low-absorption modes are related to the absorptive properties of ice at each selected wavelength, respectively. Corresponding images from each filter mode were differenced (i.e., pixels were subtracted) to enhance contrast between ice-bearing and non-ice-bearing pixels, and then fed into a semantic segmen-tation model. The model was trained to detect and differentiate between water, ice, shadows, and lunar regolith. Results: Modeling results accurately discrimi-nated ice from other materials (such as frozen lunar regolith) and were used to visually resolve the spa-tial extent of surface ice. Further, outputs produced through semantic segmentation were used to estimate water-ice contents in collected imagery [(Pixels with Class = “Water Ice”)/(Sum of Pixels)*100]. Summary: These works prove promising for future in situ resource utilization (ISRU) missions which employ robotics in combination with infrared camera systems to advance science objectives (e.g., locate water-ice in frozen regolith) on the lunar sur-face. References: [1] Cannon K. M., Deutsch A. N., Head J. W., and Britt D. T. (2020) Geophysical Re-search Letters, 46, e2020GL088920. [2] Honniball C. I. et al. (2021) Nature Astronomy 5, no. 2, 121-127. [3] Li S. et al. (2018) Proceedings of the National Academy of Sciences, 115(36), 8907-8912.

A. Slabic↗

Characterization and numerical simulation of liquid refrigerant R-134a flow emerging from a flooded evaporator tube bundle

The distribution of liquid droplets emerging from an evaporator tube bundle is characterized for refrigerant R-134a with a triangular tube arrangement with a pitch of 1.167. The purpose of this research was to improve understanding of the droplet ejection process to aid in design of evaporators typically used in larger chiller systems. A laser and camera system captured images of the evaporator headspace at varying conditions. Conventional shadowgraphy techniques were applied to recognize and match droplets for velocity calculations. The evaporator conditions varied with bundle mass fluxes of 20.3 and 40.7 kg s -1 m -2 , top-rows heat fluxes of 15.8 and 31.5 kWm -2 , and outlet saturation temperatures of 4.4 and 12.8 °C. Conditions ranged from flooded to dryout of the top rows. Droplet number, size distribution, velocity, and liquid volume fraction are presented in the headspace above the bundle. A method to numerically duplicate the droplet loading in the headspace using CFD with a Lagrangian discrete-phase model is also presented and verified, providing a powerful design tool. Liquid distribution in the headspace is found to be a strong function of all varied properties, particularly mass flux, liquid level, and saturation temperature

42 ENGINEERING↗

Cine recording ophthalmoscope

Camera system provides accurate photographic recording during acceleration of centrifuge and permits immediate observation of dynamic changes in retinal circulation by a closed-circuit television loop. System consists of main camera, remote control unit, and strobe power supply unit, and is used for fluorescein studies and dynamometry sequences.

Fitzgerald, J. W.↗

Omniview motionless camera orientation system

A device for omnidirectional image viewing providing pan-and-tilt orientation, rotation, and magnification within a hemispherical field-of-view that utilizes no moving parts. The imaging device is based on the effect that the image from a fisheye lens, which produces a circular image of at entire hemispherical field-of-view, which can be mathematically corrected using high speed electronic circuitry. More specifically, an incoming fisheye image from any image acquisition source is captured in memory of the device, a transformation is performed for the viewing region of interest and viewing direction, and a corrected image is output as a video image signal for viewing, recording, or analysis. As a result, this device can accomplish the functions of pan, tilt, rotation, and zoom throughout a hemispherical field-of-view without the need for any mechanical mechanisms. The preferred embodiment of the image transformation device can provide corrected images at real-time rates, compatible with standard video equipment. The device can be used for any application where a conventional pan-and-tilt or orientation mechanism might be considered including inspection, monitoring, surveillance, and target acquisition.

Zimmermann, Steven D.↗

Omniview motionless camera orientation system

An apparatus and method is provided for converting digital images for use in an imaging system. The apparatus includes a data memory which stores digital data representing an image having a circular or spherical field of view such as an image captured by a fish-eye lens, a control input for receiving a signal for selecting a portion of the image, and a converter responsive to the control input for converting digital data corresponding to the selected portion into digital data representing a planar image for subsequent display. Various methods include the steps of storing digital data representing an image having a circular or spherical field of view, selecting a portion of the image, and converting the stored digital data corresponding to the selected portion into digital data representing a planar image for subsequent display. In various embodiments, the data converter and data conversion step may use an orthogonal set of transformation algorithms.

Martin, H. Lee↗

KSC Tech Transfer News, Volume 2, No. 2

This issue contains articles about: (1) the Innovative Partnerships Program (IPP) and the manager of the program, Alexis Hongamen, (2) New Technology Report (NTR) on a Monte Carlo Simulation to Estimate the Likelihood of Direct Lightning Strikes, (3) Kennedy Space Center's Applied Physics Lab, (4) a virtual ruler that is used for many applications, (5) a portable device that finds low-level leaks, (6) a sun-shield, that supports in-space cryogenic propellant storage, (7) lunar dust modeling software, (8) space based monitoring of radiation damage to DNA, (9) the use of light-emitting diode (LED) arrays vegetable production system, (10) Dust Tolerant Intelligent Electrical Connection Systems, (11) Ice Detection Camera System Upgrade, (12) Repair Techniques for Composite Structures, (13) Cryogenic Orbital Testbed, and (14) copyright protection.

Makufka, David↗

The new near-infrared array camera at the University of Rochester

A near-infrared array camera system has been constructed for use in the 1-5 micron region. The camera is based on a 32 x 32 element InSb focal plane array. The performance of most of the individual detectors in the system is found to be comparable to or better than the performance of any single-element InSb detector system currently in use. A thorough description of the camera system and its image processing subsystems is given, and some sample images are provided.

Forrest, W. J.↗

Spectroscopic imaging of limiter heat and particle fluxes and the resulting impurity sources during Wendelstein 7-X startup plasmas

A combined IR and visible camera system [G. A. Wurden et al., “A high resolution IR/visible imaging system for the W7-X limiter,” Rev. Sci. Instrum. (these proceedings)] and a filterscope system [R. J. Colchin et al., Rev. Sci. Instrum. 74, 2068 (2003)] were implemented together to obtain spectroscopic data of limiter and first wall recycling and impurity sources during Wendelstein 7-X startup plasmas. Both systems together provided excellent temporal and spatial spectroscopic resolution of limiter 3. Narrowband interference filters in front of the camera yielded C-III and H{sub α} photon flux, and the filterscope system provided H{sub α}, H{sub β}, He-I, He-II, C-II, and visible bremsstrahlung data. The filterscopes made additional measurements of several points on the W7-X vacuum vessel to yield wall recycling fluxes. The resulting photon flux from both the visible camera and filterscopes can then be compared to an EMC3-EIRENE synthetic diagnostic [H. Frerichs et al., “Synthetic plasma edge diagnostics for EMC3-EIRENE, highlighted for Wendelstein 7-X,” Rev. Sci. Instrum. (these proceedings)] to infer both a limiter particle flux and wall particle flux, both of which will ultimately be used to infer the complete particle balance and particle confinement time τ{sub P}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

Plate Impact and Penetration at the Ballistic Launch Tube: Experiments

This report details the data collected from plate impact experiments performed at the Ballistics Launch Tube (BLT) in May 2019. The experiments consisted of 62 shots of copper projectiles (cylindrical and ogive) impacting 1/4", 1/2", and 3/4" aluminum plates at varying velocities. An additional 14 shots of copper cylinders on a 1" steel plate were fired at varying velocities as a Taylor anvil test. We recorded videos of the impact events and resulting fragmentation using a multi-view system of three high speed cameras. The purpose of these tests was to collect high quality data from the multi-view camera system and create digital representations of the deformed target, projectile and fragments. This data is intended to be used as validation data set for high fidelity simulation codes. This report covers the experimental setup, diagnostics, and collected data. Data processing and analysis are underway and will be discussed in a separate report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A 1D Lyman-alpha Profile Camera for Plasma Edge Neutral Studies on the DIII-D Tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-a) emission from hydrogenic isotopes which can be used to infer neutral density and ionization rate proles. The system is composed of two cameras, each providing a toroidal fan of twenty lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of approximately 2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-a reflective mirror, narrow-band Ly-a transmission fiter, and a 20 channel AXUV photodetector. The combined mirror and transmission fiter have a FWHM of 5 nm, centered near the Ly-a wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-a brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling and radial particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution imaging of the Venus night side using a Rockwell 128x128 HgCdTe array

The University of Hawaii operates an infrared camera with a 128x128 HgCdTe detector array on loan from JPL's High Resolution Imaging Spectrometer (HIRIS) project. The characteristics of this camera system are discussed. The infrared camera was used to obtain images of the night side of Venus prior to and after inferior conjunction in 1988. The images confirm Allen and Crawford's (1984) discovery of bright features on the dark hemisphere of Venus visible in the H and K bands. Our images of these features are the best obtained to date. Researchers derive a pseudo rotation period of 6.5 days for these features and 1.74 microns brightness temperatures between 425 K and 480 K. The features are produced by nonuniform absorption in the middle cloud layer (47 to 57 Km altitude) of thermal radiation from the lower Venus atmosphere (20 to 30 Km altitude). A more detailed analysis of the data is in progress.

Hodapp, K.-W.↗

Occultation Predictions Using CCD Strip-Scanning Astrometry

We are developing the method of CCD strip-scanning astrometry for the purpose of deriving reliable advance predictions for occultations involving small objects in the outer solar system. We are using a camera system based on a Ford/Loral 2Kx2K CCD with the Crossley telescope at Lick Observatory for this work. The columns of die CCD are aligned East-West, the telescope drive is stopped, and the CCD is clocked at the same rate that the stars drift across it. In this way we obtain arbitrary length strip images 20 arcmin wide with 0.58" pixels. Since planets move mainly in RA, it is possible to obtain images of the planet and star to be occulted on the same strip well before the occultation occurs. The strip-to-strip precision (i.e. reproducibility) of positions is limited by atmospheric image motion to about 0.1" rms per strip. However, for objects that are nearby in R.A., the image motion is highly correlated and their relative positions are good to 0.02" rms per strip. We will show that the effects of atmospheric image motion on a given strip can be removed if a sufficient number of strips of a given area have been obtained. Thus, it is possible to reach an rms precision of 0.02" per strip, corresponding to about 0.3 of Pluto or Triton's angular radius. The ultimate accuracy of a prediction based on strip-scanning astrometry is currently limited by the accuracy of the positions of the stars in the astrometric network used and by systematic errors most likely due to the optical system. We will show the results of . the prediction of some recent occultations as examples of the current capabilities and limitations of this technique.

Dunham, Edward W.↗