The Plant Water Management Experiments: Hydroponics 3 & 4

As humans consider longer-duration missions in space, NASA has identified production of fresh vegetables aboard spacecraft as beneficial for crew nutrition, mental wellbeing, and enabling bioregenerative life support (i.e., air, water, and waste processing). Current low-g plant growth techniques have successfully grown a variety of leafy and flowering plants. However, unique microgravity fluidics challenges to maintain plant moisture levels persist which hamper overall system reliability. The Plant Water Management (PWM) experiments seek to demonstrate low-cost, low-mass, reusable plant growth systems that leverage recent advances in low-g capillary fluidics phenomena to provide routine, largely passive, water delivery to plants. This paper presents findings from a series of PWM-Hydroponics 3 & 4 experiments, which were collected during three ISS flight operations that occurred in March, May, and July of 2021. Open hydroponic capillary channel flows with synthetic evapo-transpiring plant models were used. Tests demonstrated flow stability for single and parallel channel flow configurations across a range of flow rates, plant types, and plant arrangements. Technology demonstrations of both passive aeration and bubble phase separation are reported. We provide details of the data reduction and archive. Insights from the successful flight demonstrations provide a foundation from which follow-on PWM-Hydroponics 5 & 6 experiments on ISS, potentially incorporate living plants, are being considered. Xx Summary of positives and negatives..

Marc B. Wasserman↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Gas Flow and Ion Transfer in Heated ESI Capillary Interfaces

Transfer capillaries are the preferred means to transport ions, generated by electrospray ionization, from ambient conditions to vacuum. During the transfer of ions through the narrow, long tubes into vacuum, substantial losses are typical. However, recently it was demonstrated that these losses can be avoided altogether. To understand the experimental observation and provide a general model for the ion transport, here, we investigate the ion transport through capillaries by numerical simulation of interacting ions. The simulation encompasses all relevant factors, such as space charge, diffusion, gas flow, and heating. Special attention is paid to the influence of the gas flow on the transmission and especially the change imposed by heating. The gas flow is modeled by a one-dimensional gas dynamics description. A large number of ions are treated as point particles in this gas flow. This allows to investigate the influence of the capillary heating on the gas flow and by this on the ion transport. The results are compared with experimental findings. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wettability and capillary effects: Dynamics of pinch-off in unconstricted straight capillary tubes

We study the interfacial evolution of immiscible two-phase flow within a capillary tube in the partial wetting regime using direct numerical simulation. We investigate the flow patterns resulting from the displacement of a more viscous fluid by a less viscous one under a wide range of wettability conditions. We find that beyond a wettability dependent critical capillary number, a uniform displacement by a less viscous fluid can transition into a growing finger that eventually breaks up into discrete blobs by a series of pinch-off events for both wetting and non-wetting contact angles. This study validates previous experimental observations of pinch-off for wetting contact angles and extends those to non-wetting contact angles. We find that the blob length increases with the capillary number. We observe that the time between consecutive pinch-off events decreases with the capillary number and is greater for more wetting conditions in the displaced phase. Here, we further show that the blob separation distance as a function of the difference between the inlet velocity and the contact line speed collapses into two monotonically decreasing curves for wetting and non-wetting contact angles. For the phase separation in the form of pinch-off, this work provides a quantitative study of the emerging length and time scales and their dependence on the wettability conditions, capillary effects, and viscous forces.

42 ENGINEERING↗

Experimental Investigation of Two-Phase Flow in Consolidating and Intact Salt: Analysis of Capillary Pressure Measurements from Core Labs

Two-phase flow of brine and air through very low permeability porous media is the dominant fluid flow state in and around geologic repositories for nuclear waste disposal. Constitutive models developed for other subsurface media (shale, sandstone, limestone, etc.) have been adopted but never experimentally parameterized for geologic salt. This report summarizes results of scoping capillary pressure and brine saturation measurements on reconsolidated run-of-mine salt and intact geologic salt samples. These measurements were obtained using mercury injection tests and yielded values of threshold pressure, pore-size distribution, and mercury saturation. The brine capillary pressure curve was then inferred from the raw mercury capillary pressure data. This report also summarizes estimates of the constitutive model parameters from the brine saturation and capillary pressure data (Brooks and Corey, 1964; van Genuchten, 1980). The results suggests that the model of van Genuchten (1980) is better suited for brine-air-salt systems. Additional testing is needed for the low brine saturation range of the capillary pressure curve where the present suite of tests did not yield sufficient data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Plant Water Management Experiments: Soil

A simple means of watering plants in the low-g environment aboard orbiting spacecraft is not obvious. Since the beginning of spaceflight, numerous approaches have been pursued to water plants that seek to maximize plant viability and system reliability, while minimizing crew time and system complexity. We are not there yet. The Plant Water Management (PWM) Soil experiments seek to apply recent advances in low-g capillary fluidics phenomena to the challenges faced by plant growth operations aboard spacecraft. The primary challenge is to establish earth-like flows minimizing low-g specific adaptations required of the plants. This is difficult due to the ever-present fluid physics challenges of poorly-wetting multiphase inertial-visco-capillary flows in geometrically complex conduits and containers. In this paper, we present recent flight results for the PWM Soil experiments where arcillite ‘soil reservoirs’ are arranged in a non-wetting host soil that serves as an O2-breathing wetting barrier. In this way, a largely terrestrial water-soil environment is mimicked where, as liquid is evapo-transpired through the growing plant foliage, the effective water table passively ‘falls’ reducing viscous lengths and increasing water uptake for the plant. We present data from 6 days of 24-7 experiments on the ISS testing 3 different plant root models. We also present and correlate a capillary flow model which captures the primary features of the flow. Our summary is valued for the assessment of current and future low-g plant watering systems employing soil media.

microgravity↗

Investigation of pressure drop in capillary tube for mixed refrigerant Joule-Thomson cryocooler

A capillary tube is commonly used in small capacity refrigeration and air-conditioning systems. It is also a preferred expansion device in mixed refrigerant Joule-Thomson (MR J-T) cryocoolers, since it is inexpensive and simple in configuration. However, the flow inside a capillary tube is complex, since flashing process that occurs in case of refrigeration and air-conditioning systems is metastable. A mixture of refrigerants such as nitrogen, methane, ethane, propane and iso-butane expands below its inversion temperature in the capillary tube of MR J-T cryocooler and reaches cryogenic temperature. The mass flow rate of refrigerant mixture circulating through capillary tube depends on the pressure difference across it. There are many empirical correlations which predict pressure drop across the capillary tube. However, they have not been tested for refrigerant mixtures and for operating conditions of the cryocooler. The present paper assesses the existing empirical correlations for predicting overall pressure drop across the capillary tube for the MR J-T cryocooler. The empirical correlations refer to homogeneous as well as separated flow models. Experiments are carried out to measure the overall pressure drop across the capillary tube for the cooler. Three different compositions of refrigerant mixture are used to study the pressure drop variations. The predicted overall pressure drop across the capillary tube is compared with the experimentally obtained value. The predictions obtained using homogeneous model show better match with the experimental results compared to separated flow models.

42 ENGINEERING↗

Numerical simulation of non-viscous liquid pinch-off using a coupled level set-boundary integral method

Simulations of the pinch-off of an inviscid fluid column are carried out based upon a potential flow model with capillary forces. The interface location and the time evolution of the free surface boundary condition are both approximated by means of level set techniques on a fixed domain. The interface velocity is obtained via a Galerkin boundary integral solution of the 3D axisymmetric Laplace equation. A short-time analytical solution of the Raleigh-Taylor instability in a liquid column is available, and this result is compared with our numerical experiments to validate the algorithm. The method is capable of handling pinch-off and after pinch-off events, and simulations showing the time evolution of the fluid tube are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CVB: the Constrained Vapor Bubble Capillary Experiment on the International Space Station MARANGONI FLOW REGION

The Constrained Vapor Bubble (CVB) is a wickless, grooved heat pipe and we report on a full- scale fluids experiment flown on the International Space Station (ISS). The CVB system consists of a relatively simple setup a quartz cuvette with sharp corners partially filled with either pentane or an ideal mixture of pentane and isohexane as the working fluids. Along with temperature and pressure measurements, the two-dimensional thickness profile of the menisci formed at the corners of the quartz cuvette was determined using the Light Microscopy Module (LMM). Even with the large, millimeter dimensions of the CVB, interfacial forces dominate in these exceedingly small Bond Number systems. The experiments were carried out at various power inputs. Although conceptually simple, the transport processes were found to be very complex with many different regions. At the heated end of the CVB, due to a high temperature gradient, we observed Marangoni flow at some power inputs. This region from the heated end to the central drop region is defined as a Marangoni dominated region. We present a simple analysis based on interfacial phenomena using only measurements from the ISS experiments that lead to a predictive equation for the thickness of the film near the heated end of the CVB. The average pressure gradient for flow in the film is assumed due to the measured capillary pressure at the two ends of the liquid film and that the pressure stress gradient due to cohesion self adjusts to a constant value over a distance L. The boundary conditions are the no slip condition at the wall interface and an interfacial shear stress at the liquid- vapor interface due to the Marangoni stress, which is due to the high temperature gradient. Although the heated end is extremely complex, since it includes three- dimensional variations in radiation, conduction, evaporation, condensation, fluid flow and interfacial forces, we find that using the above simplifying assumptions, a simple successful model can be developed.

heat pipes↗

Design and development of liquid filled polymeric fibers with flexure rate viscoelastic properties

The design and development of a novel category of bi-component polymeric fibers, made of a polymeric sheath and a liquid core is described. To understand and to analyze the flow of molten polymer and liquid within a spin pack, we built a macroscale analogon where co-flow of polymer and liquid is investigated systematically. The macroscale analogon is composed of a glass cylinder with a finite length and a coaxial capillary. The inner fluid flows in the capillary and at its outlet meets the outer fluid flowing inside the glass cylinder. The fluids are pumped into the setup using pressurized bottles with controlled flow rates. A high-speed camera is placed in front of the glass cylinder to record the transient and the steady flow of the two phases and the morphology of their interface during co-flow. We systematically analyzed the combination of various fluids and different injection channel geometries, and used these findings to design a customized spin pack. Extrusion trials with molten polymers and specific liquids resulted in the production of liquid filled polymeric fibers (LFF) with different amounts of liquid from 3% to 33%vol. and diameters from 150μm to 1mm. Fiber morphology has been investigated with the help of optical microscopy and computer tomography, in order to analyze both surface and core morphology. Mechanical characterization of fibers has been carried out with special care to the damping capacity of such fibers using two different methods: two point bending tests to evaluate the energy dissipation of fibers upon bending at low frequency values (0.005-0.5Hz), and analysis of vibration reduction to determine the quality factor at the resonance frequency of the 1{sup st} and 3{sup rd} vibration mode.

36 MATERIALS SCIENCE↗

The FUNPET—a New Hybrid Ion Funnel-Ion Carpet Atmospheric Pressure Interface for the Simultaneous Transmission of a Broad Mass Range

An atmospheric pressure interface transports ions from ambient pressure to the low-pressure environment of a mass spectrometer. A capillary coupled to an ion funnel is widely used. However, conventional ion funnels do little to negate the large amount of energy picked up by high-mass ions from the gas flow through the capillary. There has been little work done on the effects of gas flow on ion transmission, and the previous studies have all been limited to low-mass, low-charge ions. In this work, we account for the effects of gas flow, diffusion, and electric fields (static and oscillating) on ion trajectories and use simulations to design a new hybrid ion funnel-ion carpet (FUNPET) interface that transmits a broad mass range with a single set of instrument conditions. The design incorporates a virtual jet disruptor where pressure buildup and counter flow dissipate the supersonic jet that results from gas flow into the interface. This, and the small exit aperture that can be used with the FUNPET, reduces the gas flow into the next stage of differential pumping. The virtual jet disruptor thermalizes ions with a broad range of masses (1 kDa to 1 GDa), and once thermalized, they are transmitted into next region of the mass spectrometer with low excess kinetic energy. The FUNPET interface is easy to fabricate from flexible printed circuit board and a support frame made by 3D printing. The performance of the interface was evaluated using charge detection mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrohydrodynamic heat pipe experiments

Experiments with two electrohydrodynamic heat pipes are reported. Both devices employ an electromechanical flow structure for axial liquid flow and a capillary wicking structure for (1) collection of condensed liquid at the cooled end and (2) distribution of this liquid at the heated end. One device has circumferential grooving for the capillary structure and the other has feltmetal wicking. The experiments successfully demonstrate the electrohydrodynamic heat pipe concept. Compatibility of the two circumferential wick structures with an axial electromechanical flow structure is also demonstrated. A significant mismatch of the capillary groove and electrohydrodynamic pumping capabilities results in severe hydrodynamic burn-out limiting in the first heat pipe. Both devices have very poor over-all thermal conductances of the order of 1-2 W/deg C, reflecting the generally poor heat-transfer properties of the dielectric working fluids required in electrohydrodynamic heat pipes.

Jones, T. B.↗

Plasma facing components with capillary porous system and liquid metal coolant flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 °C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently, a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [A. Khodak and R. Maingi, Nucl. Mater. Energy 26, 100935 (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In the case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a fusion nuclear science facility [Kessel et al., Fusion Sci. Technol. 75, 886 (2019)]: 10 T toroidal field and 10 MW/m 2 peak incident heat flux. Finally, computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Facing Components with Capillary Porous System and Liquid Metal Coolant Flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [Khodak and Maingi (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile, as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a Fusion Nuclear Science Facility [Kessel et al. (2019)]: 10T toroidal field and 10 MW/m2 peak incident heat flux. Computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

High Heat Flux↗

Experimental characterization of discharge plasma dynamics in a square capillary for prospective applications in laser wakefield acceleration

Research on plasma generated by electrical discharge in gas-filled capillaries plays an important role in advancing laser wakefield accelerators. We present a comprehensive study of the temporal and spatial distribution of plasma density within a short, 1 cm long, square-shaped capillary filled with hydrogen gas. Two transverse capillary sizes, 500 μm and 300 μm, were investigated achieving peak plasma densities of 0.9 × 10 18 cm −3 and 2.5 × 10 18 cm −3 , respectively, at the capillary center. In addition, we explore how these distributions depend on discharge parameters, specifically discharge current and gas flow through the capillary. Plasma density was determined by analyzing the Stark broadening of the hydrogen Balmer-alpha line. The results obtained were compared with the theoretical models and simulations. The comparison between the model predictions and the experimental data at the transient ionization stage of the discharge reveals a discrepancy of a factor of ∼1.3–2.1, depending on the capillary size, which is thoroughly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Origin of shear thickening in semidilute wormlike micellar solutions and evidence of elastic turbulence

The origin of shear thickening in an equimolar semidilute wormlike micellar solution of cetylpyridinium chloride and sodium salicylate was investigated in this work by using Couette rheometry, flow visualization, and capillary Rheo-particle image velocimetry. The use of the combined methods allowed the discovery of gradient shear banding flow occurring from a critical shear stress and consisting of two main bands, one isotropic (transparent) of high viscosity and one structured (turbid) of low viscosity. Mechanical rheometry indicated macroscopic shear thinning behavior in the shear banding regime. However, local velocimetry showed that the turbid band increased its viscosity along with the shear stress, even though barely reached the value of the viscosity of the isotropic phase. This shear band is the precursor of shear induced structures that subsequently give rise to the average increase in viscosity or apparent shear thickening of the solution. Further increase in the shear stress promoted the growing of the turbid band across the flow region and led to destabilization of the shear banding flow independently of the type of rheometer used, as well as to vorticity banding in Couette flow. At last, vorticity banding disappeared and the flow developed elastic turbulence with chaotic dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗