Search NASA⌕ Search

SEARCH · Search NASA

Results for “care”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Bring'em Back Alive or at Least Carefully

Within the next decade, the world's space agencies plan to launch a variety of robotic spacecraft that will return samples from the surface of Mars, the tail of a comet, the nucleus of a comet, the surface of an asteroid, and the solar wind. Most of these places are not considered likely spots for life, but any mission returning from a location with the potential for harboring life will require special containment and handling because of the possible inclusion of living entities within returned samples. In its 1997 report on sample return from Mars, the Space Studies Board of the National Research Council (NRC) noted that the only risk of significant adverse effects would be from returning a replicating organism. Furthermore, the report noted: 'While the probability of returning a replicating biological entity in a sample from Mars' is judged to be low and the risk of pathogenic or ecological effects is lower still, the risk is not zero. Therefore, it is reasonable that NASA adopt a prudent approach, erring on the side of caution and safety when dealing with returned samples. More recently, a 1998 NRC report on small solar system bodies (asteroids, comets, planetary satellites, and interplanetary dust) recommended a similarly cautious approach for samples returned from anywhere else within the solar system that could have environmental conditions conducive for harboring life. We have not detected life elsewhere in the solar system, at least not yet. Nonetheless, the rationale behind the conservative approach to sample handling is similar to the environmental, health, and safety measures taken on Earth when transporting or handling infectious agents or importing non-native organisms to a new area. Better safe than sorry.

Race, Margaret S.↗

Cockpit Interruptions and Distractions: Effective Management Requires a Careful Balancing Act

Managing several tasks concurrently is an everyday part of cockpit operations. For the most part, crews handle concurrent task demands efficiently, yet crew preoccupation with one task to the detriment of performing other tasks is one of the more common forms of error in the cockpit. Most pilots are familiar with the December 1972 L1011 crash that occurred when the crew became preoccupied with a landing gear light malfunction and failed to notice that someone had inadvertently bumped off the autopilot. More recently a DC-9 landed gear-up in Houston when the crew, preoccupied with an stabilized approach, failed to recognize that the gear was not down because they had not switched the hydraulic pumps to high. We have recently started a research project to study why crews are vulnerable to these sorts of errors. As part of that project we reviewed NTSB reports of accidents attributed to crew error; we concluded that nearly half of these accidents involved lapses of attention associated with interruptions, distractions, or preoccupation with one task to the exclusion of another task. We have also analyzed 107 ASRS reports involving competing tasks; we present here some of our conclusions from those ASRS reports. These 107 reports involved 21 different types of routine tasks crews neglected at a critical moment while attending to another task. Sixty-nine percent of the neglected tasks involved either failure to monitor the current status or position of the aircraft or failure to monitor the actions of the pilot flying or taxiing. Thirty-four different types of competing activities distracted or preoccupied the pilots. Ninety percent of these competing activities fell into one of four broad categories: communication (e.g., discussion among crew or radio communication), heads-down work (e.g., programming the FMS or reviewing approach plates), responding to abnormals, or searching for VMC traffic. We will discuss examples of each of these four categories and suggest things crews can do to reduce their vulnerability to these and similar situations.

Dismukes, R. K.↗

Critical Care Dialysis System

Organon Teknika Corporation's REDY 2000 dialysis machine employs technology originally developed under NASA contract by Marquardt Corporation. The chemical process developed during the project could be applied to removing toxic waste from used dialysis fluid. This discovery led to the development of a kidney dialysis machine using "sorbent" dialysis, a method of removing urea from human blood by treating a dialysate solution. The process saves electricity and, because the need for a continuous water supply is eliminated, the patient has greater freedom.

Source record↗

Moon Technology for Skin Care

Estee Lauder uses digital image analyzer and software based on NASA lunar research in evaluation of cosmetic products for skincare. Digital image processing brings out subtleties otherwise undetectable, and allows better determination of product's effectiveness. Technique allows Estee Lauder to quantify changes in skin surface form and structure caused by application of cosmetic preparations.

Source record↗

Controversies in cardiovascular care: silent myocardial ischemia

The objective evidence of silent myocardial ischemia--ischemia in the absence of classical chest pain--includes ST-segment shifts (usually depression), momentary left ventricular failure, and perfusion defects on scintigraphic studies. Assessment of angina patients with 24-hour ambulatory monitoring may uncover episodes of silent ischemia, the existence of which may give important information regarding prognosis and may help structure a more effective therapeutic regimen. The emerging recognition of silent ischemia as a significant clinical entity may eventually result in an expansion of current therapy--not only to ameliorate chest pain, but to minimize or eliminate ischemia in the absence of chest pain.

NASA Program Space Medicine↗

Analysis of Stainless Steel Sandwich Panels with a Metal Foam Care for Lightweight Fan Blade Design

The quest for cheap, low density and high performance materials in the design of aircraft and rotorcraft engine fan and propeller blades poses immense challenges to the materials and structural design engineers. Traditionally, these components have been fabricated using expensive materials such as light weight titanium alloys, polymeric composite materials and carbon-carbon composites. The present study investigates the use of P sandwich foam fan blade made up of solid face sheets and a metal foam core. The face sheets and the metal foam core material were an aerospace grade precipitation hardened 17-4 PH stainless steel with high strength and high toughness. The stiffness of the sandwich structure is increased by separating the two face sheets by a foam core. The resulting structure possesses a high stiffness while being lighter than a similar solid construction. Since the face sheets carry the applied bending loads, the sandwich architecture is a viable engineering concept. The material properties of 17-4 PH metal foam are reviewed briefly to describe the characteristics of the sandwich structure for a fan blade application. A vibration analysis for natural frequencies and P detailed stress analysis on the 17-4 PH sandwich foam blade design for different combinations of skin thickness and core volume %re presented with a comparison to a solid titanium blade.

Min, James B.↗

Space Weather: What is it, and Why Should a Meteorologist Care?

"Space weather" is a term coined almost 15 years ago to describe environmental conditions ABOVE Earth's atmosphere that affect satellites and astronauts. As society has become more dependent on technology, we nave found that space weather conditions increasingly affect numerous commercial and infrastructure sectors: airline operations, the precision positioning industry, and the electric power grid, to name a few. Similar to meteorology where "weather" often refers to severe conditions, "space weather" includes geomagnetic storms, radiation storms, and radio blackouts. But almost all space weather conditions begin at the Sun--our middle-age, magnetically-variable star. At NASA, the science behind space weather takes place in the Heliophysics Division. The Space Weather Prediction Center in Boulder, Colorado, is manned jointly by NCAA and US Air Force personnel, and it provides space weather alerts and warnings for disturbances that can affect people and equipment working in space and on Earth. Organizationally, it resides in NOAA's National Weather Service as one of the National Centers for Environmental Prediction. In this seminar we hope to give the audience a brief introduction to the causes of space weather, discuss some of the effects, and describe the state of the art in forecasting. Our goal is to highlight that meteorologists are increasingly becoming the "first responders" to questions about space weather causes and effects.

SaintCyr, Chris↗

Advanced Technology Applications for Combat Casualty Care

Exploration Medical Capability (ExMC) is an element of NASA s Human Research Program (HRP). ExMC s goal is to address the risk of the "Inability to Adequately Recognize or Treat an Ill or Injured Crewmember." This poster highlights the approach ExMC has taken to address this goal and our current areas of interest. The Space Medicine Exploration Medical Condition List (SMEMCL) was created to identify medical conditions of concern during exploration missions. The list was derived from space flight medical incidents, the shuttle medical checklist, the International Space Station medical checklist, and expert opinion. The conditions on the list were prioritized according to mission type by a panel comprised of flight surgeons, physician astronauts, engineers, and scientists. From the prioritized list, the ExMC element determined the capabilities needed to address the medical conditions of concern. Where such capabilities were not currently available, a gap was identified. The element s research plan outlines these gaps and the tasks identified to achieve the desired capabilities for exploration missions.

Watkins, Sharmila↗

A Primary Care Approach to the Diagnosis and Management of Peripheral Arterial Disease

The objectives of this work are: (1) Be able to recognize characteristic symptoms of intermittent claudication (2) Diagnose PAD on the basis of history, physical exam, and simple limb blood pressure measurements (3) Recognize the significance of peripheral artery disease as a marker for coronary or cerebrovascular atherosclerosis (4) Provide appropriate medical management of atherosclerosis risk factors-- including use of antiplatelet therapy to reduce risk of myocardial infarction, stroke and death (5) Manage symptoms of intermittent claudication with program of smoking cessation, exercise, and medication The diagnosis of intermittent claudication secondary to peripheral artery disease (PAD) can often be made on the basis of history and physical examination. Additional evaluation of PAD is multi-modal and the techniques used will vary depending on the nature and severity of the patient's presenting problem. Most patients can be appropriately managed without referral for specialized diagnostic services or interventions.

Dawson, David L.↗

Particular Characterisation of an In-Vitro-DTH Test to Monitor Cellular Immunity - Applications for Patient Care and Space Flight

Goal:i) Characterization of the role of the main immune reactive cell types contributing to the cellular immune response in the in-vitro DTH and ii) Validation of the in-vitro DTH under different clinical and field conditions. Methods:As positive control whole blood was incubated in the in-vitro DTH, supernatants were gathered after 12, 24 and 48h. Readout parameters of this test are cytokines in the assay's supernatant. To determine the role of T-cells, monocytes and natural killer (NK), these cell populations were depleted using magnetic beads prior to in-vitro-DTH incubation. Validation of the test has occurred under clinical (HIV-patients, ICU) and field-conditions (parabolic/space-flights, confinement). Results:T-cell depletion abandoned almost any IL-2 production and reduced IFN-gamma production irrespective of the type of antigen, whereas CD56 depleted cultures tended to lower IL-2 secretion and IFN-gamma and to parallel a IL-10-increase after viral challenge. This IL-10-increase was seen also in CD14-depleted setups. DTH read-out was significantly different under acute stress (parabolic flight) or chronic stress (ISS), respectively. Preliminary data of HIV infected patients demonstrate that this test can display the contemporary immune status during an antiviral therapy. Conclusion:The in-vitro DTH mirrors adaptive and innate immune activation and may serve as tool also for longitudinal follow up of Th1/Th2 weighed immune response under adverse life conditions on earth and in space. It is planned to implement the assay in the on the ISS (MoCISS).

Feurecker, M.↗