Search NASA⌕ Search

SEARCH · Search NASA

Results for “characterization techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Photoelectrochemical and photocatalytic activities of bilayered TiO{sub 2}/Ga:WO{sub 3} photoelectrode by spray pyrolysis technique

Graphical abstract: Photoelectrochemical performance of WO{sub 3}, Ga:WO{sub 3} and bilayered TiO{sub 2}/Ga:WO{sub 3} photoelectrodes and degradation of salicylic acid using immobilized bilayered TiO{sub 2}/Ga:WO{sub 3} photocatalyst. - Highlights: • Photoelectrochemical and photocatalytic activities of bilayered TiO{sub 2}/Ga:WO{sub 3} photoelectrode. • Structural analysis of WO{sub 3}, Ga:WO{sub 3} and bilayered TiO{sub 2}/Ga:WO{sub 3} thin films. • Photoelectrocatalytic degradation of salicylic acid. - Abstract: WO{sub 3}, Ga:WO{sub 3} and bilayered TiO{sub 2}/Ga:WO{sub 3} photocatalysts are synthesized by spray pyrolysis technique. Synthesized films are characterized by various characterization techniques such as structural, morphological and photoelectrochemical properties. Synthesized films are polycrystalline in nature. The TiO{sub 2}/Ga:WO{sub 3} photoelectrode exhibits highest photocurrent density (1569 μA/cm{sup 2}) than that of pure WO{sub 3} and Ga:WO{sub 3} films due the prevent the recombination of photogenerated electron-hole pairs. Photoelectrocatalytic activities of WO{sub 3}, Ga:WO{sub 3} and bilayered TiO{sub 2}/Ga:WO{sub 3} photoelectrodes are tested for photodegradation of salicylic acid as a model organic pollutant. The results show that the bilayered TiO{sub 2}/Ga:WO{sub 3} photocatalyst has an efficient photocatalytic ability as compared to pure WO{sub 3} and Ga:WO{sub 3} photocatalysts.

36 MATERIALS SCIENCE↗

Techniques to characterize dynamics in biomaterials microenvironments: XPCS and microrheology of alginate/PEO–PPO–PEO hydrogels

Many recent studies have highlighted the timescale for stress relaxation of biomaterials on the microscale as an important factor in regulating a number of cell-material interactions, including cell spreading, proliferation, and differentiation. Relevant timescales on the order of 0.1–100 s have been suggested by several studies. While such timescales are accessible through conventional mechanical rheology, several biomaterials have heterogeneous structures, and stress relaxation mechanisms of the bulk material may not correspond to that experienced in the cellular microenvironment. Here we employ X-ray photon correlation spectroscopy (XPCS) to explore the temperature-dependent dynamics, relaxation time, and microrheology of multicomponent hydrogels comprising of commercial poly(ethylene oxide)–poly(propylene oxide)–poly(ethylene oxide) (PEO–PPO–PEO) triblock copolymer F127 and alginate. Previous studies on this system have shown thermoreversible behavior in the bulk oscillatory shear rheology. At physiological temperatures, bulk rheology of these samples shows behavior characteristic of a soft solid, with G' > G" and no crossover between G' and G" over the measurable frequency range, indicating a relaxation time >125 s. By contrast, XPCS-based microrheology shows viscoelastic behavior at low frequencies, and XPCS-derived correlation functions show relaxation times ranging from 10–45 s on smaller length scales. Finally, we are able to use XPCS to effectively probe the viscoelasticity and relaxation behavior within the material microenvironments.

36 MATERIALS SCIENCE↗

Novel Monitoring Techniques for Characterizing Frictional Interfaces in the Laboratory

A pressure-sensitive film was used to characterize the asperity contacts along a polymethyl methacrylate (PMMA) interface in the laboratory. The film has structural health monitoring (SHM) applications for flanges and other precision fittings and train rail condition monitoring. To calibrate the film, simple spherical indentation tests were performed and validated against a finite element model (FEM) to compare normal stress profiles. Experimental measurements of the normal stress profiles were within -7.7% to 6.6% of the numerical calculations between 12 and 50 MPa asperity normal stress. The film also possessed the capability of quantifying surface roughness, an important parameter when examining wear and attrition in SHM applications. A high definition video camera supplied data for photometric analysis (i.e., the measure of visible light) of asperities along the PMMA-PMMA interface in a direct shear configuration, taking advantage of the transparent nature of the sample material. Normal stress over individual asperities, calculated with the pressure-sensitive film, was compared to the light intensity transmitted through the interface. We found that the luminous intensity transmitted through individual asperities linearly increased 0.05643 ± 0.0012 candelas for an increase of 1 MPa in normal stress between normal stresses ranging from 23 to 33 MPa.

47 OTHER INSTRUMENTATION↗

A Comprehensive Evaluation of the Performance and Materials Chemistry of a Sililcone-Based Replicating Compound

The objective of this project was to characterize the performance and chemistry of a siliconebased replicating compound. Some silicone replicating compounds are useful for critical inspection of surface features. Common applications are for examining micro-cracks, surface pitting, scratching, and other surface defects. Materials characterization techniques were used: FTIR, XPS, ToF-SIMS, AFM, and Confocal Microscopy to evaluate the replicating compound. These techniques allowed for the characterization and verification of the resolution capabilities and surface contamination that may be a result of using the compound. FTIR showed the compound is entirely made from silicone constituents. The AFM and Confocal Microscopy results showed the compound does accurately replicate the surface features to the claimed resolution. XPS and ToF-SIMS showed there is a silicone contaminant layer left behind when a cured replica is peeled off a surface. Attempts to clean off the contamination could not completely remove all silicone residues.

36 MATERIALS SCIENCE↗

System and technique for characterizing fluids using ultrasonic diffraction grating spectroscopy

A system for determining property of multiphase fluids based on ultrasonic diffraction grating spectroscopy includes a diffraction grating on a solid in contact with the fluid. An interrogation device delivers ultrasound through the solid and a captures a reflection spectrum from the diffraction grating. The reflection spectrum exhibits peaks whose relative size depends on the properties of the various phases of the multiphase fluid. For example, for particles in a liquid, the peaks exhibit dependence on the particle size and the particle volume fraction. Where the exact relationship is know know a priori, data from different peaks of the same reflection spectrum or data from the peaks of different spectra obtained from different diffraction gratings can be used to resolve the size and volume fraction.

47 OTHER INSTRUMENTATION↗

IN SITU MEASUREMENT TECHNIQUES FOR CHARACTERIZING PULSE JET MIXING OF SLURRIES

Metrics to characterize mixing are the just suspended velocity (UJS) and the cloud height (HC). Two ultrasonic instruments to characterize pulse jet mixing of slurries were developed and deployed to measure related metrics: the thickness of the settled bed and the concentration within the cloud as a function of elevation [C(Z)]. Ultrasonic Doppler velocimetry was used to measure the thickness of the bed of nonmoving particles (the settled solids layer). During pulse jet mixing at the critical suspension velocity (UCS) the settled solids layer thickness approached zero at the end of the jet pulse. The UCS is related to the just suspended velocity (UJS) for steady mixing. Ultrasonic attenuation was used to measure the suspended solids concentration at locations in the vessel to determine the concentration profile as a function of radial position and elevation. The concentration profile provided data inside the cloud and complemented the visual measurement of the cloud height (HC). The UDV and the ultrasonic concentration probe data are used to evaluate the desired metrics based on relative measurements. The relative measurements are correlated with results obtained from a series of working standards created for each slurry, and used to develop correlations specific to each slurry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗