Search NASA⌕ Search

SEARCH · Search NASA

Results for “chemical concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Combined XRD/XRF Instrument for Lunar Resource Assessment

Robotic surface missions to the Moon should be capable of measuring mineral as well as chemical abundances in regolith samples. Although much is already known about the lunar regolith, our data are far from comprehensive. Most of the regolith samples returned to Earth for analysis had lost the upper surface, or it was intermixed with deeper regolith. This upper surface is the part of the regolith most recently exposed to the solar wind; as such it will be important to resource assessment. In addition, it may be far easier to mine and process the uppermost few centimeters of regolith over a broad area than to engage in deep excavation of a smaller area. The most direct means of analyzing the regolith surface will be by studies in situ. In addition, the analysis of the impact-origin regolith surfaces, the Fe-rich glasses of mare pyroclastic deposits, are of resource interest, but are inadequately known; none of the extensive surface-exposed pyroclastic deposits of the Moon have been systematically sampled, although we know something about such deposits from the Apollo 17 site. Because of the potential importance of pyroclastic deposits, methods to quantify glass as well as mineral abundances will be important to resource evaluation. Combined x ray diffraction (XRD) and x ray fluorescence (XRF) analysis will address many resource characterization problems on the Moon. XRF methods are valuable for obtaining full major-element abundances with high precision. Such data, collected in parallel with quantitative mineralogy, permit unambiguous determination of both mineral and chemical abundances where concentrations are high enough to be of resource grade. Collection of both XRD and XRF data from a single sample provides simultaneous chemical and mineralogic information. These data can be used to correlate quantitative chemistry and mineralogy as a set of simultaneous linear equations, the solution of which can lead to full characterization of the sample. The use of Rietveld methods for XRD data analysis can provide a powerful tool for quantitative mineralogy and for obtaining crystallographic data on complex minerals.

Vaniman, D. T.↗

High Sensitive and Low Power Nanosensors for Space and Terrestrial Applications

Nanotechnology offers the ability to work at the molecular level, atom by atom, to create large structures with fundamentally new molecular organization. It is essentially concerned with materials, devices, and systems whose structures and components exhibit novel and significantly improved physical, chemical and biological properties, phenomena, and process control due to their nanoscale size. A nanosensor technology has been developed at NASA Ames using nanostructure, single walled carbon nanotubes (SWNTs). The nanosensors have achieved low detection limit of chemicals in the concentration range of ppm to ppb. Due to large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors offer higher sensitivity, lower power consumption and a more robust solution than most state-of-the-art systems making them attractive for space and terrestrial applications. An example of a sensor module, the first space flown nano device, will be introduced in this presentation. Such sensors have drawn attention from space community for global weather monitoring, space exploration, life search in the universe, and launch pad fuel leak detection and in-flight cabin air and life support system monitoring, and engine operation monitoring. Additionally, the wireless capability of such sensors can be leveraged to network mobile and fixed-base detection and warning systems for civilian population centers, military bases and battlefields, as well as other high-value or high-risk assets and areas in industry.

Jing Li↗

The electrokinetic behavior of calcium oxalate monohydrate in macromolecular solutions

Electrophoretic mobilities were measured for calcium oxalate monohydrate (COM) in solutions containing macromolecules. Two mucopolysaccharides (sodium heparin and chrondroitin sulfate) and two proteins (positively charged lysozyme and negatively charged bovine serum albumin) were studied as adsorbates. The effects of pH, calcium oxalate surface charge (varied by calcium or oxalate ion activity), and citrate concentration were investigated. All four macromolecules showed evidence for chemical adsorption. The macromolecule concentrations needed for reversing the surface charge indicated that the mucopopolysacchrides have greater affinity for the COM surface than the proteins. The amount of proteins that can chemically adsorb appears to be limited to approximately one monomolecular layer. When the surface charge is high, an insufficient number of proteins can chemically adsorb to neutralize or reverse the surface charge. The remaining surface charge is balanced by proteins held near the surface by longer range electrostatic forces only. Citrate ions at high concentrations appear to compete effectively with the negative protein for surface sites but show no evidence for competing with the positively charged protein.

Curreri, P. A.↗

Queen bees offload pesticide burden to eggs when social buffering is overwhelmed

Honey bee colonies pollinate about one-third of the world’s food crops, and their rapid decline directly threatens agricultural productivity and ecosystem stability. Understanding how colony-level social defenses influence pesticide fate and the circumstances under which they fail is therefore a crucial question in pollinator biology. We used biological accelerator mass spectrometry (BioAMS), a sensitive radiotracer technique, to track the movement of a model pesticide through a small honey bee colony under laboratory conditions. We tested the hypothesis that social buffering protects honey bees from toxic accumulation and that this protection can be overcome, leading to maternal offloading of the pesticide to developing eggs. Consistent with this hypothesis, our results identified three key mechanisms governing chemical movement within a social insect colony: (1) worker bees initially decrease dietary pesticide levels by 95% through diet filtering and deposition in honeycombs, though this declines to 86% by day 10; (2) queen bees maintain markedly lower pesticide levels than workers but, over time, they accumulate the pesticide in their ovaries and transfer it into developing eggs, revealing a previously undocumented protective mechanism in reproductive individuals; and (3) the presence of a queen bee shifts colony-wide chemical distribution by concentrating worker exposure and increasing pesticide deposition in wax. Our findings show that honey bee colonies function as integrated detoxification networks, in which chemical fate depends on complex social behaviors and caste-specific physiology. When social buffering is overwhelmed, reproductive queens may survive by transferring their chemical burden to their offspring.

Biological and medical sciences↗

Data to Accompany: PM2.5 is insufficient to explain personal PAH exposure

Fine particulate matter (PM2.5) air quality index (AQI) data from outdoor stationary monitors and Hazard Mapping System (HMS) smoke density data from satellites are often used as proxies for personal chemical exposure. Silicone wristbands can quantify more individualized exposure data than stationary air monitors or smoke satellites. However, it is not understood how these proxy measurements compare to chemical data measured from wristbands. We hypothesized that predictive models for personal chemical exposure would be significantly improved by expanding beyond stationary PM2.5 AQI data or satellite HMS data to also include environmental and behavioral information. In Eugene, Oregon, participants wore daily wristbands, carried a phone that recorded locations, and answered daily questionnaires for a seven-day period in multiple seasons. We gathered publicly available daily PM2.5 AQI data and HMS data. We analyzed wristbands for 94 organic chemicals, including 53 polycyclic aromatic hydrocarbons (PAHs). Wristband chemical detections and concentrations, behavioral variables (e.g., time spent indoors), and environmental conditions (e.g., PM2.5 AQI) significantly differed between seasons. Machine learning models were fit to predict personal chemical exposure using PM2.5 AQI only, HMS only, and a multivariate feature set including PM2.5 AQI, HMS, and other environmental and behavioral information. On average, the multivariate models increased predictive accuracy by approximately 70% compared to either the AQI model or the HMS model for all chemicals modeled. This study provides evidence that PM2.5 AQI data alone or HMS data alone is insufficient to explain personal chemical exposures. Our results identify additional key predictors of personal chemical exposure.

Bramer, Lisa M↗

The chemical composition of the dust-free Martian atmosphere - Preliminary results of a two-dimensional model

This paper describes a two-dimensional model of the Martian atmosphere, in which chemical, radiative and dynamical processes are treated interactively. The model is developed for a carbon dioxide-hydrogen-oxygen-nitrogen atmosphere and provides estimates of concentrations for 19 chemical species. The dynamical equations are expressed in the transformed Eulerian coordinates. The wave driving and eddy mixing coefficients resulting from gravity and Rossby wave absorption are computed consistently with the evolving distribution of the mean zonal wind. The net diabatic heating/cooling rate is derived from a detailed radiative scheme including the contributions of CO2, O3, H2O and O2, and is computed consistently with the calculated distribution of temperature and trace species quantities. The computed temperature field as well as the meridional and seasonal variations of ozone column abundance are in good agreement with the distributions observed by Mariner 9 and Viking spacecrafts and the results obtained by previous studies. The present version of the model does not include the effects of dust, clouds and polar hood and only the chemistry in a dust-free atmosphere is considered.

Moreau, D.↗

PM 2.5 Is Insufficient to Explain Personal PAH Exposure

To understand how chemical exposure can impact health, researchers need tools that capture the complexities of personal chemical exposure. In practice, fine particulate matter (PM 2.5 ) air quality index (AQI) data from outdoor stationary monitors and Hazard Mapping System (HMS) smoke density data from satellites are often used as proxies for personal chemical exposure, but do not capture total chemical exposure. Silicone wristbands can quantify more individualized exposure data than stationary air monitors or smoke satellites. However, it is not understood how these proxy measurements compare to chemical data measured from wristbands. In this study, participants wore daily wristbands, carried a phone that recorded locations, and answered daily questionnaires for a 7-day period in multiple seasons. We gathered publicly available daily PM 2.5 AQI data and HMS data. We analyzed wristbands for 94 organic chemicals, including 53 polycyclic aromatic hydrocarbons. Wristband chemical detections and concentrations, behavioral variables (e.g., time spent indoors), and environmental conditions (e.g., PM 2.5 AQI) significantly differed between seasons. Machine learning models were fit to predict personal chemical exposure using PM 2.5 AQI only, HMS only, and a multivariate feature set including PM 2.5 AQI, HMS, and other environmental and behavioral information. On average, the multivariate models increased predictive accuracy by approximately 70% compared to either the AQI model or the HMS model for all chemicals modeled. This study provides evidence that PM 2.5 AQI data alone or HMS data alone is insufficient to explain personal chemical exposures. Our results identify additional key predictors of personal chemical exposure.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensors for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g., electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Sensor arrays for detecting analytes in fluids

Chemical sensors for detecting analytes in fluids comprise first and second conductive elements (e.g. electrical leads) electrically coupled to and separated by a chemically sensitive resistor which provides an electrical path between the conductive elements. The resistor comprises a plurality of alternating nonconductive regions (comprising a nonconductive organic polymer) and conductive regions (comprising a conductive material) transverse to the electrical path. The resistor provides a difference in resistance between the conductive elements when contacted with a fluid comprising a chemical analyte at a first concentration, than when contacted with a fluid comprising the chemical analyte at a second different concentration. Arrays of such sensors are constructed with at least two sensors having different chemically sensitive resistors providing dissimilar such differences in resistance. Variability in chemical sensitivity from sensor to sensor is provided by qualitatively or quantitatively varying the composition of the conductive and/or nonconductive regions. An electronic nose for detecting an analyte in a fluid may be constructed by using such arrays in conjunction with an electrical measuring device electrically connected to the conductive elements of each sensor.

Lewis, Nathan S.↗

Evaluating Np(v) disproportionation: effect of Np concentration

The role of Np(V) concentration as a potential chemical driver of Np(V) disproportionation was investigated by probing Np redox chemistry in two different acid media using visible-near-infrared absorbance spectroscopy. In situ spectroscopy of chemically and electrochemically manipulated Np oxidation states at molar concentrations of Np underscores the difficulty in stabilizing pure Np(V), even in dilute acid. A Np(VI) component coexisting with the majority Np(V) component was observed in both HNO 3 and HCl. Electrochemical tuning and subsequent spectroscopic analysis of the Np(VI/V) ratio revealed neptunyl self-complexation as a key mechanism occurring in both acid media. Chemical reduction of the Np(VI) component and stabilization of a minor Np(IV) component in HNO 3 were observed; however, spectral data indicated that these two oxidation states were not observed to coexist, and pure Np(V) was stabilized only briefly. These findings demonstrate that high Np concentrations significantly affect the redox chemistry of Np in acidic solutions. Finally, the occurrence of Np(V) disproportionation could not be definitely determined by spectral data, but other mechanisms such as self-complexation and radiolysis, which potentially compete with disproportionation, must be considered.

Gilson, Sara E. [Oak Ridge National Laboratory (OR↗

Tropospheric nitric oxide measurements

Nitric oxide (NO) plays a key role in tropospheric photo-chemistry. The photochemical oxidation of hydrocarbons, for example, can serve as either a source or a sink for ozone, depending on the local abundance of NO. Nitric oxide also helps govern atmospheric concentrations of the hydroxyl (OH) radical. The OH radical is the single most important player in photochemical transformations because it controls the atmospheric lifetimes of so many chemical species. Although NO serves as a very effective catalyst in many important chemical processes, its concentration is low enough to normally be expressed in units of parts per trillion by volume (pptv). Consequently, commercially available detectors for NO (with detection limits of about one part per billion) have proven to be unsuitable for use anywhere except in urban areas and near other local pollution sources. Under the sponsorship of NASA's Global Tropospheric Experiment (GTE), Wallops has developed an extremely sensitive detector with a detection limit of a few pptv. The system was specifically designed for aircraft use, with the objective of applying it in global aircraft studies of tropospheric chemistry. Studies with the detector are examined.

Torres, A. L.↗

Chemical Analysis and Water Recovery Testing of Shuttle-Mir Humidity Condensate

Humidity condensate collected and processed in-flight is an important component of a space station drinking water supply. Water recovery systems in general are designed to handle finite concentrations of specific chemical components. Previous analyses of condensate derived from spacecraft and ground sources showed considerable variation in composition. Consequently, an investigation was conducted to collect condensate on the Shuttle while the vehicle was docked to Mir, and return the condensate to Earth for testing. This scenario emulates an early ISS configuration during a Shuttle docking, because the atmospheres intermix during docking and the condensate composition should reflect that. During the STS-89 and STS-91 flights, a total volume of 50 liters of condensate was collected and returned. Inorganic and organic chemical analyses were performed on aliquots of the fluid. Tests using the actual condensate were then conducted with scaled-down elements of the Russian condensate recovery system to determine the quality of water produced. The composition and test results are described, and implications for ISS are discussed.

Mudgett, Paul D.↗

Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems which are less dependent on hardware that would need to be launched on a regular basis. Three systems for electrochemical production of potable water disinfectants are being assessed for use on the International Space Station (ISS). Since there is a wide variability in the literature with regards to efficacy in both concentration and exposure time of these disinfectants, there is a need to establish baseline efficacy values. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria and to determine whether these electrochemical disinfection devices are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

Vega, Leticia↗

Atmospheric ice nuclei concentration measurements over a high altitude-station in the Western Ghats, India

Mixed-phase and ice clouds play a significant role in modulating the Indian summer monsoon rainfall, and modeling studies suggest that inaccurate representation of ice nucleating particles (INP) is one of the factors, which have resulted in a deficiency in the prediction of cloud properties and hydrological cycle. We do not understand the ice nucleation mechanisms to represent the ice formation in the model, and therefore more INP measurements at various supercooled temperatures are needed. This study reports for the first time real-time INP concentration at a high altitude station in the Western Ghats region of India, and these results will be used to constrain the ice nucleation parameterizations in the model. The variation of INP for any particular cloud condition can have strong microphysical responses of mixed-phase precipitation formation processes. Also, to improve the representation of heterogeneous ice nucleation, INP measurements of various types of aerosols commonly observed over the Indian region are needed. This study presents, the INP concentrations and daily concentration of non-refractory chemical composition (organics, sulfate, nitrate, ammonium, and chloride), cloud condensation nuclei (CCN), and aerosol size distribution. Spectrometer for Ice Nuclei (SPIN) was operated to measure INP concentration at the mountain site from August to December 2018. INP measurements were performed at three different temperatures (-25, -30, and - 34 °C) in the immersion freezing mode relevant for mixed-phase cloud conditions. The average INP concentrations approximately varied from 0.18 to 12.4 L-1, 0.39 to 24 L-1, 1.1 to 40.2 L-1 at -25, -30, and - 34 °C, respectively. These concentrations are within the concentrations reported in the literature from different regions across the globe. The air mass back trajectory analysis showed that continental air mass contains more INP compared to maritime air mass. The information on INP concentration and chemical characteristics of aerosol will help to improve heterogeneous ice nucleation parameterization in numerical models.

Kumar, Anil V.↗

Rigorous computation of short-range order unifies its controversial effects in complex concentrated alloys

Direct experimental observations of chemical short-range order (SRO) in complex concentrated alloys (CCAs) have triggered high interest. However, the reported effects of SRO on yield stresses are controversial, and their atomic-scale mechanisms are elusive, which limits our ability to utilize SRO in alloy design. Here we tackle this challenge using an advanced computational approach that rigorously takes into account the critical lattice distortion in CCAs and further verify our theoretical predictions with experiments. We show that the CoCrNi model alloy has a narrow temperature window around 670 °C for SRO formation. This explains why the mechanical effect of SRO is observed in some experiments but not in others. Here, we propose an effective alloy-doping method to control SRO and reveal atomic-bonding types that dominate SRO formation for different alloys. The strategies and insights generally apply to a broad spectrum of alloys, laying the foundation for designing advanced alloys by manipulating their SRO.

36 MATERIALS SCIENCE↗

Static and Dynamic Gradient Based Directional Transportation of Neutral Molecules in Swollen Polymer Films

Abstract Materials which selectively transport molecules offer powerful opportunities for concentrating and separating chemical agents. Here, utilizing static and dynamic chemical gradients, transport of molecules within swollen crosslinked polymers is demonstrated. Using an ≈200 μm static hydroxyl to hexyl gradient, the neutral ambipolar nerve agent surrogate diethyl (cyanomethyl)phosphonate (DECP) is directionally transported and concentrated 60‐fold within 4 hours. To accelerate transport kinetics, a dynamic gradient (a “travelling wave”) is utilized. Here, the non‐polar dye pyrene was transported. The dynamic gradient is generated by an ion exchange process triggered by the localized introduction of an aqueous NaCl solution, which converts the gel from hydrophobic to hydrophilic. As the hydrophilic region expands, associated water enters the gel, and pyrene is pushed ahead of the expansion front. The dynamic gradient provides about 10‐fold faster transport kinetics than the static gradient.

Ali, Mohammad A.↗