Search NASA⌕ Search

SEARCH · Search NASA

Results for “cloud detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Potential Use of a Bayesian Network for Discriminating Flash Type from Future GOES-R Geostationary Lightning Mapper (GLM) data

Continuous monitoring of the ratio of cloud flashes to ground flashes may provide a better understanding of thunderstorm dynamics, intensification, and evolution, and it may be useful in severe weather warning. The National Lighting Detection Network TM (NLDN) senses ground flashes with exceptional detection efficiency and accuracy over most of the continental United States. A proposed Geostationary Lightning Mapper (GLM) aboard the Geostationary Operational Environmental Satellite (GOES-R) will look at the western hemisphere, and among the lightning data products to be made available will be the fundamental optical flash parameters for both cloud and ground flashes: radiance, area, duration, number of optical groups, and number of optical events. Previous studies have demonstrated that the optical flash parameter statistics of ground and cloud lightning, which are observable from space, are significantly different. This study investigates a Bayesian network methodology for discriminating lightning flash type (ground or cloud) using the lightning optical data and ancillary GOES-R data. A Directed Acyclic Graph (DAG) is set up with lightning as a "root" and data observed by GLM as the "leaves." This allows for a direct calculation of the joint probability distribution function for the lighting type and radiance, area, etc. Initially, the conditional probabilities that will be required can be estimated from the Lightning Imaging Sensor (LIS) and the Optical Transient Detector (OTD) together with NLDN data. Directly manipulating the joint distribution will yield the conditional probability that a lightning flash is a ground flash given the evidence, which consists of the observed lightning optical data [and possibly cloud data retrieved from the GOES-R Advanced Baseline Imager (ABI) in a more mature Bayesian network configuration]. Later, actual GLM and NLDN data can be used to refine the estimates of the conditional probabilities used in the model; i.e., the Bayesian network is a learning network. Methods for efficient calculation of the conditional probabilities (e.g., an algorithm using junction trees), finding data conflicts, goodness of fit, and dealing with missing data will also be addressed.

Solakiewiz, Richard↗

SaS4D Home Team Ul

This software allows for a lidar-generated point cloud to be converted to a water-tight geometry, and finally an MCNP radiation transport input deck automatically. This includes the automatic registration of detectors and placement of pre-generated radiation transport models of these detectors in the scene.

Swinney, Mathew↗

Spectral mapping of Jupiter and the Galilean satellites in the near infrared

A near-infrared mapping spectrometer is included in the science complement of the Galileo Mission, which will explore Jupiter and its satellites in the mid-1980s. The objectives of the infrared mapping spectrometer experiment are to map compositional units on the surfaces of the Jovian satellites and to characterize the mineral content of these units. For Jupiter's atmosphere, this experiment will investigate such areas as cloud properties and the spatial and temporal variability of minor species. The instrument consists of a telescope, a plane grating spectrometer, a Si and InSb detector array, and a passive radiative cooler. The spectral range is 0.7-5.2 microns, covered with a resolution of 0.025 micron. A wobbling secondary mirror in the telescope provides one dimension of spatial scanning, while the other dimension is provided by motion of the spacecraft scan platform.

Carlson, R. W.↗

Optical Parametric Technology for Methane Measurements

Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas, with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. Yet, lack of understanding of the processes that control CH4 sources and sinks and its potential release from stored carbon reservoirs contributes significant uncertainty to our knowledge of the interaction between carbon cycle and climate change. At Goddard Space Flight Center (GSFC) we have been developing the technology needed to remotely measure CH4 from orbit. Our concept for a CH4 lidar is a nadir viewing instrument that uses the strong laser echoes from the Earth's surface to measure CH4. The instrument uses a tunable, narrow-frequency light source and photon-sensitive detector to make continuous measurements from orbit, in sunlight and darkness, at all latitudes and can be relatively immune to errors introduced by scattering from clouds and aerosols. Our measurement technique uses Integrated Path Differential Absorption (IPDA), which measures the absorption of laser pulses by a trace gas when tuned to a wavelength coincident with an absorption line. We have already demonstrated ground-based and airborne CH4 detection using Optical Parametric Amplifiers (OPA) at 1651 nm using a laser with approximately 10 microJ/pulse at 5kHz with a narrow linewidth. Next, we will upgrade our OPO system to add several more wavelengths in preparation for our September 2015 airborne campaign, and expect that these upgrades will enable CH4 measurements with 1% precision (10-20 ppb).

oscillator↗

Detecting gravitational signatures of dark matter with atom gradiometers

We study the purely gravitational signatures of dark matter from the ultralight to the ultraheavy mass range in proposed long-baseline atom gradiometers, focusing on terrestrial designs, such as AION-km and MAGIS-km, as well as space-based concepts, such as MAGIS-space, AEDGE and AEDGE+. Due to its exceptional acceleration sensitivity and depending on astrophysical backgrounds, a detector similar to AEDGE+ could detect a dark matter subcomponent which constitutes 𝒪⁡(10%) of the local dark matter energy density and is populated by compact clumps of mass between 10 6 kg and 10 10 kg (10 −25 ⁢𝑀⊙ ≲ 𝑀 ≲10 −21⁢ 𝑀⊙) in an otherwise unexplored region of dark matter model space. Furthermore, because the gravitational observable depends on the relative gravitational time delay measured by spatially separated atomic clouds, we find that atom gradiometers are parametrically more sensitive than laser interferometers, such as LIGO and LISA, to fast-oscillating spacetime perturbations sourced by energy density and pressure fluctuations of ultralight dark matter. Depending on astrophysical backgrounds, a detector akin to AEDGE+ could probe a DM overdensity of 𝒪⁡(10) times the local dark matter energy density for masses 𝑚 ≲10 −17 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft X-ray sources in the bar of the Large Magellanic Cloud

X-ray observations of the Large Magellanic Cloud were made with two collimated proportional counters having high angular resolution, a wide spectral dynamic range and a large aperture. Counting rates in the two detectors during the entire rocket flight are presented, and a number of soft X-ray (0.5-2 keV) sources were found in the bar of the LMC, having luminosities between 10 to the 37th and 10 to the 38th ergs/s. Emission in the 0.15-0.28 keV band from LMC X-3 was also detected.

Mckee, J. D.↗

Far IR Observations of the Magellanic Clouds

Several Large Magellanic and Small Magellanic Cloud H II regions were observed at 50 and 100 microns. Observations were made on three flights of the Kuiper Airborne Observatory using a six channel detector system. Fully sampled maps were made simultaneously at both wavelengths. The integrated properties of the H II regions are listed and interpretations of the results regarding stellar formation are presented.

Jones, T. J.↗

Summary of airborne chlorine and hydrogen chloride gas measurements for August 20 and September 5, 1977 Voyager launches at Air Force Eastern Test Range, Florida

Airborne chlorine and hydrogen chloride measurements were made in the tropospheric ground cloud following the Voyager launches of August 20 and September 5, 1977. The maximum observed hydrogen chloride concentration for both launches was about 25 to 30 parts per million (ppm) occurring typically 2 to 6 minutes after launch. By completion of the sampling mission (1-1/2 hours for August, 4-1/2 hours for September), the maximum in-cloud concentration decayed to about 1 to 2 ppm. Maximum observed chlorine concentrations were about 40 to 55 parts per billion (ppb) about 2 to 8 minutes after launch; by about 15 minutes after launch, chlorine concentrations were less than 10 ppb (detection limit). In-cloud chlorine concentrations were well below 1 percent of hydrogen chloride concentrations. The appendix of the report discusses the chlorine instrument and the laboratory evaluation of the detector.

Gregory, G. L.↗

Performance Assessment of the Optical Transient Detector and Lightning Imaging Sensor: Predicted Diurnal Variability - 1

Laboratory calibration and observed background radiance data are used to determine the effective sensitivities of the Optical Transient Detector and Lightning Imaging Sensor, as functions of local hour and pixel location within the instrument arrays. The effective LIS thresholds, expressed as radiances emitted normal to cloud top, are 4.0 plus or minus 0.7 and 7.6 plus or minus 3.3 micro J/ster/m (sup 2) for night and local noon; the OTD thresholds am 11.7 plus or minus 2.2 and 16.8 plus or minus 4.6 microJ/ster/m (sup 2). LIS and OTD minimum signal to noise ratios occur from 0800 to 1600 local time, and attain values of 10 plus or minus 2 and 20 plus or minus 3, respectively. False alarm rate due to instrument noise yields approximately 5 false triggers per month for LIS, and is negligible for OTD. Flash detection efficiency, based on prior optical pulse sensor measurements, is predicted to be 93 plus or minus 4% and 73 plus or minus 11% for LIS night and noon; 56 plus or minus 7% and 44 plus or minus 9% for OTD night and noon, corresponding to a 12 - 20% diurnal variability and LIS:OTD ratio of 1.7. Use of the weighted daily mean detection efficiency (i.e., not controlling for local hour) corresponds to a sigma = 8 - 9% uncertainty. These are likely overestimates of actual flash detection efficiency due to differences in pixel ground field-of-view across the instrument arrays, which are not accounted for in the validation optical pulse sensor data.

Boccippio, Dennis J.↗

Micro pulse laser radar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering is disclosed. The transmitter of the micro pulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited to optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that micropulse lider systems are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

New technologies for UV detectors

Several technologies are currently being developed, leading to substantial improvements in the performance of UV detectors or significant reductions in power or weight. Four technologies discussed are (1) thin-film coatings to enhance the UV sensitivity of CCD's, (2) highly innovative magnet assemblies that dramatically reduce weight and result in virtually no external flux, (3) new techniques for curving microchannel plates (MCP's) so that single plates can be used to prevent ion feedback and present highly localized charge clouds to an anode structure, and (4) high-performance alternatives to glass-based MCP's. In item (2), for example, very robust magnets are made out of rare earth materials such as samarium cobalt, and cladding magnets are employed to prevent flux from escaping from the detector into the external environment. These new ultralight magnet assemblies are able to create strong, exceptionally uniform magnetic fields for image intensification and focusing of photoelectrons. The principle advantage of such detectors is the quantum efficiencies of 70-80 percent obtained throughout ultraviolet wavelengths (900-2000 A), the highest of any device. Despite the improvements achieved under item (3), high-performance alternatives to conventional glass-based MCP's potentially offer three distinct new advantages that include (1) a 30-100-fold improvement in dynamic range resulting in correspondingly higher signal-to-noise ratios, (2) the use of pure dielectric and semiconductor materials that will not outgas contaminants that eventually destroy photocathodes, and (3) channels that have constant spacing providing long-ranged order since the plates are made using photolithography techniques from the semiconductor industry. The manufacturers of these advanced-technology MCP's, however, are a couple of years away from actually producing a functioning image intensifier. In contrast to the use of CCD's for optical, ground based observations, there is no single detector technology in the ultraviolet that dominates or is as universally suitable for all applications. Thus, several technological problems, recent advances, and the impact that these new enabling technologies represent for UV applications are addressed.

Joseph, C. L.↗

Micro pulse lidar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering has been demonstrated. The transmitter of the micropulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited by optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that systems built on the micropulse lidar concept are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

Crossed-grid charge locator

Circuit locates center of cloud of charge on wire grid to within 6.5 micrometers. Wires in vicinity of charge cloud develop voltages that are processed by priority encoders to develop coarse and fine position codes. Device is used with microchannel plate amplifier in X-ray photon detectors, electron microscopes, and closed-circuit television.

Harrison, D. C.↗

The Landsat Data Continuity Mission Operational Land Imager: Radiometric Performance

The Operational Land Imager (OLI) is one of two instruments to fly on the Landsat Data Continuity Mission (LDCM), which is scheduled to launch in December 2012 to become the 8th in the series of Landsat satellites. The OLI images in the solar reflective part of the spectrum, with bands similar to bands 1-5, 7 and the panchromatic band on the Landsat-7 ETM+ instrument. In addition, it has a 20 nm bandpass spectral band at 443 nm for coastal and aerosol studies and a 30 nm band at 1375 nm to aid in cirrus cloud detection. Like ETM+, spatial resolution is 30 m in the all but the panchromatic band, which is 15 meters. OLI is a pushbroom radiometer with approximately 6000 detectors per 30 meter band as opposed to the 16 detectors per band on the whiskbroom ETM+. Data are quantized to 12 bits on OLI as opposed to 8 bits on ETM+ to take advantage of the improved signal to noise ratio provided by the pushbroom design. The saturation radiances are higher on OLI than ETM+ to effectively eliminate saturation issues over bright Earth targets. OLI includes dual solar diffusers for on-orbit absolute and relative (detector to detector) radiometric calibration. Additionally, OLI has 3 sets of on-board lamps that illuminate the OLI focal plane through the full optical system, providing additional checks on the OLI's response[l]. OLI has been designed and built by Ball Aerospace & Technology Corp. (BATC) and is currently undergoing testing and calibration in preparation for delivery in Spring 2011. Final pre-launch performance results should be available in time for presentation at the conference. Preliminary results will be presented below. These results are based on the performance of the Engineering Development Unit (EDU) that was radiometrically tested at the integrated instrument level in 2010 and assembly level measurements made on the flight unit. Signal-to-Noise (SNR) performance: One of the advantages of a pushbroom system is the increased dwell time of the detectors allowing for significantly higher SNR than equivalent aperture whiskbroom systems. OLI performance based on the EDU at the "typical" radiance level as specified in the OLI requirements document are about 10 times better than ETM+ performance and 2-3 times better than the requirements for OLI (Table 1).

Markham, Brian↗

Static diffusion cloud chambers

The chamber geometry and optical arrangement are described. The supersaturation range is given and consists of readings taken at five fixed points: 0.25%, 0.5%, 0.75%, 1.0%, and 1.25%. The detection system is described including light source, cameras, and photocell detectors. The temperature control and the calibration of the chamber are discussed.

Ayers, G.↗

A search for diffuse band profile variations in the rho Ophiuchi cloud

High signal-to-noise profiles of the broad diffuse interstellar band at 4430 A were obtained on the 2.2-m telescope at the Mauna Kea Observatory, using the newly-developed pulse-counting multi-anode microchannel array detector system in an effort to determine whether the band profile varies with mean grain size as expected if the band is produced by absorbers embedded in grain lattices. The lack of profile variability over several lines of sight where independent evidence indicates that the mean grain size varies shows that lambda 4430 is probably not formed by the same grains that are responsible for interstellar extinction at visible wavelengths. The possibility that this band is created by a population of very small ( approximately 100 A) grains is still viable, as is the hypothesis that it has a molecular origin.

Snow, T. P.↗

CO/H2 in Translucent Clouds

A thorough examination of techniques to improve the resolution of the FUSE spectrograph was undertaken. These involved co-adding time tagged data very carefully so as to remove any blurs caused by drift. In addition, data was binned by detector pulse height bin (to eliminate any positional vs. gain variations, e.g. "walk"). These techniques only resulted in an extremely modest increase in the spectral resolution, insufficient to allow the CO/H2 studies to be performed. The only remaining potential source of blur was defocus - implying the instrument was never properly focused on orbit. Private discussions with B.G. Anderson of the FUSE team resulted in my learning that this was in fact the case - the slidgrating distance was never optimized on orbit - resulting in a degradation of the peak performance of the instrument. Unfortunately, this was never publicized, even to myself, a member of the instrument tem and the spectrograph designer.

Green, James↗