Search NASA⌕ Search

SEARCH · Search NASA

Results for “complex scattering objects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

204 records · Page 12

Compositions of the Surfaces of Pluto and its Satellites

The information we have on the chemical compositions of the surfaces of Pluto and Charon has been obtained from Earth-based near-infrared spectroscopy. These bodies are seen in diffusely scattered sunlight upon which absorption bands diagnostic of specific ices are superimposed. Identified so far on Pluto are molecular nitrogen (N2), methane (CH4), carbon monoxide (CO), and ethane (C2H6), all in the frozen state. Charon has the clear spectral signature of H2O ice in the crystalline phase, plus an absorption band near 2.2 microns identified as a hydrated form of NH3. No diagnostic spectra of Pluto's other satellites are currently available. A fraction of Pluto's CH4 is dissolved in solid N2, which is in the hexagonal beta-phase. When a small concentration of CH4 exists in a N2 crystalline matrix, its absorption bands are shifted in wavelength by a small but detectable amount. Indeed the shifting of the CH4 bands is diagnostic of a host matrix. In the case of Pluto, the N2 band (2.148 microns) itself is detected, but for other trans-Neptunian objects where the N2 band cannot be seen, the shifted CH4 bands demonstrate the presence of N2 or (less likely) some other spectrally neutral and transparent matrix material (e.g., Ar). The absence of detectable CO2 and H2O ices on Pluto, while they are clearly present on the otherwise very similar Triton, is noteworthy. The ices of Pluto distributed non-uniformly across its surface, and the distribution shows long-term (decadal) changes. Both seasonal and secular changes may be occurring through transport across the surface as a result of changing temperature, and by seasonal changes in the vapor pressure equilibrium of the ice with the tenuous and variable atmosphere. Models of the photochemistry of the surface ices and the atmosphere of Pluto predict the presence of several materials not yet detected; the most abundant photoproducts are expected to be C2H2, C4H2, HCN, C2H6; HCN has been detected on Triton. Both Pluto and Charon have surface components in addition to the detected ices. These materials of presently unknown composition serve to reduce the albedos of both bodies below that expected for pure ices, and in the case of Pluto impart a yellow-brown coloration; the color of Charon is more nearly neutral. It is generally thought that the non-ice components are more refractory than the ices and that they may be complex carbonaceous materials derived from the ultraviolet and charged particle processing of the surface ices. Minerals are also plausible candidates for the non-ice fraction. The refractory colored components may constitute bedrock upon which variable amounts of the ices are alternately deposited and evaporated as the seasons change. Water ice is expected to be a component of the bedrock, although it has not yet been reliably identified.

Pluto↗

Development of pseudo-random binary arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown Point-Spread Function (PSF) of the instruments [1] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in a spatial frequency domain as a Power Spectral Density (PSD) distribution [2]. For example, the measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [3], [4]. The distortion of the surface PSD distribution due to the PSF can be modeled with the Modulation Transfer Function (MTF), which is defined over the spatial frequency bandwidth of the instrument [1], [2]. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the System Under Test (SUT). Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. In previous work [5], [6] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on Binary Pseudo-Random (BPR) gratings. Here, we present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription [7] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples. [8] Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

36 MATERIALS SCIENCE↗

National Synchrotron Light Source (NSLS) 2009 Activity Report

2009 was an incredibly exciting year for light sources at Brookhaven. The National Synchrotron Light Source (NSLS) hosted more than 2,200 visiting researchers, who, along with the about 50 members of our scientific staff, produced a total of 957 publications - about 20 percent of which appeared in premier journals. Covering topics ranging from Alzheimer's disease detection to ethanol-powered fuel cells, a sampling of these findings can be found in this Activity Report. We've also seen the resurfacing of some of our long-time users hard work. I was very proud to hear that two of the three recipients of the 2009 Nobel Prize in Chemistry have ties to the NSLS. Venki Ramakrishnan, a former employee in Brookhaven's biology department and long-time user of the NSLS, now at Cambridge University, and Thomas A. Steitz of Yale University, also a long-time NSLS user, shared the prize with Ada E. Yonath of the Weizmann Institute of Science for their work on the structure and function of the ribosome. In the late 1990s, Ramakrishnan and Steitz used protein crystallography at the NSLS to gather atomic-level images of two ribosome subunits: 30S (Ramakrishnan) and 50S (Steitz). Both laureates solved the high-resolution structures for these subunits based on this data. After struggling with a rough budget for several years, we received excellent funding, and then some, this year. In addition to NSLS operations funding, we received 3 million USD in funds from the American Recovery and Reinvestment Act (ARRA). We used that additional money for two exciting projects: construction of a full-field x-ray microscope and acquisition of several advanced x-ray detectors. The x-ray microscope will be able to image objects with a targeted spatial resolution of 30 nanometers. This capability will be particularly important for new initiatives in energy research and will prepare our users for the projected 1-nanometer resolution benchmark at the National Synchrotron Light Source II (NSLS-II). The detectors project is expected to increase the throughput of several high-demand beamlines by an order of magnitude as well as enable new classes of experiments. In addition, a huge chunk of ARRA money - 150 million USD - was put toward accelerating the construction of NSLS-II, which is now taking shape across the street. Now physically much more than just a pile of dirt, NSLS-II was granted Critical Decision 3 status by the Department of Energy (DOE) early last year, giving the official go-ahead for construction. In July, construction began, marked by a groundbreaking ceremony that attracted elected officials, media, and DOE, Battelle, and Stony Brook University representatives from across the state and the country. As progress on NSLS-II continues, we're working with Stony Brook University to identify ways to capitalize on the facility's unique capabilities through the Joint Photon Sciences Institute (JPSI). Included in this effort is a series of workshops to encourage the development and application of the photon sciences with collaborative research between industries, universities, and national laboratories. We helped host three of these workshops this year, focusing on microelectronics, energy storage, and materials in next-generation energy systems. The conversation and ideas generated at these meetings has been fresh and valuable and we hope to use this model to organize research opportunities in other scientific fields. Also this year: Brookhaven was deemed the lead institution for one of DOE's 46 Energy Frontier Research Centers, focused on understanding the underlying nature of superconductivity in complex materials by using techniques at the NSLS and CFN; DOE awarded a 100,000 USD supplemental grant to our detector program to continue the development of a new generation of x-ray detectors that use germanium sensors, which, at high energies, are much more efficient than equivalent ones based on silicon; and funding for one of our largest consortia, Case Western Reserve University's Center for Synchrotron Biosciences (CSB), was renewed through the National Institutes of Health. The CSB, which operates five NSLS beamlines and serves more than 550 users, will receive a five-year, 4-million USD grant to continue to study the structure and dynamics of proteins and nucleic acids. Finally, construction of the new X9 beamline and endstation for small angle x-ray scattering (SAXS) and wide angle x-ray scattering (WAXS) was completed this year. By July, the beamline and endstation were commissioned and serving general users. This allowed for the relocation of the SAXS and WAXS experimental programs from beamline X21 to X9, providing much-needed beam time for the soft condensed matter physics, life sciences, and nanoscience communities.

30 DIRECT ENERGY CONVERSION↗

Star formation rates from young-star counts and the structure of the ISM across the NGC 346/N66 complex in the SMC

The rate at which interstellar gas is converted into stars, and its dependence on environment, is one of the pillars on which our understanding of the visible Universe is build. We present a comparison of the surface density of young stars (Σ * ) and dust surface density (Σdust) across NGC 346 (N66) in 115 independent pixels of 6 × 6 pc 2 . We find a correlation between Σ * and Σdust with a considerable scatter. A power-law fit to the data yields a steep relation with an exponent of 2.6 ± 0.2. We convert Σdust to gas surface density (Σgas) and Σ * to star formation rate (SFR) surface densities (ΣSFR), using simple assumptions for the gas-to-dust mass ratio and the duration of star formation. The derived total SFR (4 ± 1×10 –3 M ⊙ yr –1 ) is consistent with SFR estimated from the Hα emission integrated over the Hα nebula. On small scales the ΣSFR derived using Hα systematically underestimates the count-based ΣSFR, by up to a factor of 10. This is due to ionizing photons escaping the area, where the stars are counted. We find that individual 36 pc 2 pixels fall systematically above integrated disc galaxies in the Schmidt–Kennicutt diagram by on average a factor of ~7. The NGC 346 average SFR over a larger area (90 pc radius) lies closer to the relation but remains high by a factor of ~3. The fraction of the total mass (gas plus young stars) locked in young stars is systematically high (~10 per cent) within the central 15 pc and systematically lower outside (2 per cent), which we interpret as variations in star formation efficiency. The inner 15 pc is dominated by young stars belonging to a centrally condensed cluster, while the outer parts are dominated by a dispersed population. Furthermore, the observed trend could reflect a change of star formation efficiency between clustered and non-clustered star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Monte Carlo Endstation for Petascale Computing

The major achievements enabled by QMC Endstation grant include * Performance improvement on clusters of x86 multi-core systems, especially on Cray XT systems * New and improved methods for the wavefunction optimizations * New forms of trial wavefunctions * Implementation of the full application on NVIDIA GPUs using CUDA The scaling studies of QMCPACK on large-scale systems show excellent parallel efficiency up to 216K cores on Jaguarpf (Cray XT5). The GPU implementation shows speedups of 10-15x over the CPU implementation on older generation of x86. We have implemented hybrid OpenMP/MPI scheme in QMC to take advantage of multi-core shared memory processors of petascale systems. Our hybrid scheme has several advantages over the standard MPI-only scheme. * Memory optimized: large read-only data to store one-body orbitals and other shared properties to represent the trial wave function and many-body Hamiltonian can be shared among threads, which reduces the memory footprint of a large-scale problem. * Cache optimized: the data associated with an active Walker are in cache during the compute-intensive drift-diffusion process and the operations on an Walker are optimized for cache reuse. Thread-local objects are used to ensure the data affinity to a thread. * Load balanced: Walkers in an ensemble are evenly distributed among threads and MPI tasks. The two-level parallelism reduces the population imbalance among MPI tasks and reduces the number of point-to-point communications of large messages (serialized objects) for the Walker exchange. * Communication optimized: the communication overhead, especially for the collective operations necessary to determine ET and measure the properties of an ensemble, is significantly lowered by using less MPI tasks. The multiple forms of parallelism afforded by QMC algorithms make them ideal candidates for acceleration in the many-core paradigm. We presented the results of our effort to port the QMCPACK simulation code to the NVIDIA CUDA GPU platform. We restructured the CPU algorithms to express additional parallelism, minimize GPU-CPU communication, and efficiently utilize the GPU memory hierarchy. Using mixed precision on GT200 GPUs and MPI for intercommunication and load balancing, we observe typical full-application speedups of approximately 10x to 15x relative to quad-core Xeon CPUs alone, while reproducing the double-precision CPU results within statistical error. We developed an all-electron quantum Monte Carlo (QMC) method for solids that does not rely on pseudopotentials, and used it to construct a primary ultra-high-pressure calibration based on the equation of state of cubic boron nitride. We computed the static contribution to the free energy with the QMC method and obtained the phonon contribution from density functional theory, yielding a high-accuracy calibration up to 900 GPa usable directly in experiment. We computed the anharmonic Raman frequency shift with QMC simulations as a function of pressure and temperature, allowing optical pressure calibration. In contrast to present experimental approaches, small systematic errors in the theoretical EOS do not increase with pressure, and no extrapolation is needed. This all-electron method is applicable to first-row solids, providing a new reference for ab initio calculations of solids and benchmarks for pseudopotential accuracy. We compared experimental and theoretical results on the momentum distribution and the quasiparticle renormalization factor in sodium. From an x-ray Compton-profile measurement of the valence-electron momentum density, we derived its discontinuity at the Fermi wavevector finding an accurate measure of the renormalization factor that we compared with quantum-Monte-Carlo and G0W0 calculations performed both on crystalline sodium and on the homogeneous electron gas. Our calculated results are in good agreement with the experiment. We have been studying the heat of formation for various Kubas complexes of molecular hydrogen on Ti(1,2)ethylene-nH2 using Diffusion Monte Carlo. This work has been started and is ongoing. We are studying systems involving 1 and 2 Ti bonding sites with up to 10 hydrogen molecules in numerous configurations. This work will establish a benchmark that will test the accuracy of density functional calculations and establish the feasibility of our methods for similar systems.

97 MATHEMATICS AND COMPUTING↗