Search NASA⌕ Search

SEARCH · Search NASA

Results for “compute tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Determinants of the mechanical properties of bones

The mechanical properties of bones are governed by the same principles as those of man-made load-bearing structures, but the organism is able to adapt its bone structure to changes in skeletal loading. In this overview of the determinants of the strength and stiffness of bone, a continuum approach has been taken, in which the behavior of a macroscopic structure depends on its shape and size, and on the mechanical properties of the material within. The latter are assumed to depend on the composition (porosity and mineralization) and organization (trabecular or cortical bone architecture, collagen fiber orientation, fatigue damage) of the bone. The effects of each of these factors are reviewed. Also, the possible means of non-invasively estimating the strength or other mechanical properties of a bone are reviewed, including quantitative computed tomography, photon absorptiometry, and ultrasonic measurements. The best estimates of strength have been obtained with photon absorptiometry and computed tomography, which at best are capable of accounting for 90% of the strength variability in a simple in vitro test, but results from different laboratories have been highly variable.

Non-NASA Center↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Verifying X-Radiographs With Computed Tomographs

Nondestructive technique gives added confidence in inspection. Ambiguous indications in radiographic inspections of metal castings checked by computed tomography. Fast and inexpensive conventional x-ray inspection used to make film image of overall casting, and slower, more costly computed tomography used to reinspect relatively few parts of casting presenting possible diffraction patterns or other difficult-to-interpret features. Method effective in resolving ambiguities in radiographs of turbine blades. Provides same information as metallurgical sectioning.

Roy, Jagatjit↗

Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

NASA Center ARC↗

RhizoGrid Indexed Sorghum Rhizosphere Multi-Omics

PerCon SFA project data dentification of spatially resolved biomarkers of drought in Sorghum bicolor rhizosphere molecular-microbe interactions using a novel root cartography "RhizoGrid" system for sampling plants under drought and control conditions across 10 equally sized root zone environments (4 quadrants each). Each quadrant was sampled and processed for 16S amplicon, metabolomics, and X-ray computed tomography (XCT). Data download includes experimental metadata and results files for 16S rRNA sequence analysis of microbial community assembly (processed data files), liquid chromatography mass spectrometry (LC-MS) metabolomics analysis of microbial community root exudates (processed data files), X-ray computed tomography (XCT) spatial gradient analysis (raw and processed data files) of microbial community composition, and related computational modeling outputs.

59 BASIC BIOLOGICAL SCIENCES↗

The Inside View

Bio-Imaging Research, Inc., has been included in Spinoff 1990 and 1993 with spinoffs from their ACTIS (Advanced Computed Tomography Inspection System) product developed under a Marshall Space Flight Center SBIR (Small Business Innovative Research) contract. The latest application is for noninvasive nuclear waste drum inspection. With the ACTIS CT (computed tomography, CATScan) scanner, radioactive waste is examined to prove that they do not contain one-half percent free liquid or that the drum wall has lost integrity before being moved across state lines or before being permanently disposed.

Source record↗

Insight into the deformation features and capacity loss mechanisms of lithium-ion pouch cells under spherical indentation conditions

Mechanical deformation under extreme conditions is one of the important reasons for the failure of lithium-ion batteries in automotive application. However, the deformation features and component failure of lithium-ion cells to external loading has never been a design consideration. Here, in this study, we conduct spherical indentation tests on a dozen of lithium-ion cells with different capacities under different control mode conditions to investigate their deformation features and capacity loss mechanisms. The experimental results show that, under mechanical deformation conditions, internal faults of cells occur in stages, and energy accumulation and sudden release are two key processes of cell's mechanical failure. The cells' state of charge is the main factor affecting their thermal runaway behaviors. In addition, a finite element model is developed to simulate the deformation features and the failure mechanism of key components of lithium-ion pouch cells; the 3D x-ray computed tomography is employed to demonstrate its internal configuration. With this model, the force-strain response, the deformation features as well as the size of the failure area of lithium-ion cells under spherical indentation conditions are accurately predicted. In 3D x-ray computed tomography images, unique mud cracks in cooper current collector are observed, and the influence mechanisms of the isolated fragments on the cell capacities are revealed. These results may provide useful information for the mechanical structure design of the components of lithium-ion pouch cells.

25 ENERGY STORAGE↗

CT and Geophysical Data of Clinton Sandstone Cores from Ohio

Collection of computed tomography and multi-sensor core logger data of 12 wells in Ohio that intersect the Clinton Sandstone formation. This data is described along with well information in a technical report series document: Paronish, T.; Holleran, A.; Pohl, M.; Crandall, D.; Jarvis, K.; Workman, S.; Drosche, J.; McKisic, T.; Collins, C.; Thomas, M.; McDonald, J. Computed Tomography Scanning and Geophysical Measurements of the Clinton Sandstone in Ohio; DOE.NETL-2025.4949; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory, Morgantown, WV, 2025; p 68. https://doi.org/10.2172/2589262

AS↗

Experimental investigation of the dependence of void nucleation and growth on initial microstructure in high-purity titanium under tension

An experimental investigation of failure mechanisms in relation to the initial microstructure in high-purity titanium samples is presented. The initial microstructure of the specimens was measured in 3D using diffraction-contrast tomography (DCT). Ex-situ X-ray computed tomography (XCT) was used to visualize voids in specimens at various levels of deformation attained by interrupted tensile testing. Electron backscatter diffraction (EBSD) mapping was used to characterize the deformed microstructures per specimen. The investigation showed that the location of failures was unrelated to the formation of the first voids, but rather the nucleation and growth of cracks were from heavily deformed surface regions. The areas surrounding the failure-causing cracks had the highest propensity for void development of any area in the specimen. This facilitated crack propagation through the specimen via “linking up”. The failure of the specimens by microvoid coalescence was bolstered by “dimpled” fracture surfaces. Paint composed of gallium embedded in rubber was used to track the displacement of points along the loading direction of the specimens, to relate the location of failure to the material's initial microstructure. However, the correlation proved difficult, due to complex microstructural evolution involving voids, grain fragmentations, and profuse twinning. Nevertheless, it was shown that necking occurred near the largest grain in the gauge section of the specimens. This is likely caused by the decrease in strength of larger grains, causing strain to concentrate in their vicinity. Here, a comprehensive picture of the failure processes in high-purity titanium under axial loading is presented and discussed in the paper.

36 MATERIALS SCIENCE↗

Accurate measurement of porosity size and morphology in aluminium alloy laser welds

Conventional two-dimensional optical microscopy is the most common tool for capturing and quantifying keyhole collapse porosity and other defects formed during the laser welding of aluminium alloys. This approach is of limited utility since only a single longitudinal or transverse metallographic cross-section, comprising only a small fraction of the overall weld volume, can be extracted or analysed at a time. X-ray computed tomography tools, on the other hand, enable three-dimensional visualisation and analysis of porosity and defects to be made across the full weld volume. When comparing these two measurement techniques, two-dimensional microscopy tools significantly underestimated the fraction of defects present within the weld at levels between 50% and 80%. Three-dimensional x-ray computed tomography tools also provide a means for accurately characterising the location, size and morphology of irregularly shaped defects. By categorising the defect shapes using a Zingg's shape analysis, in which the distribution of defect morphologies could be quantified as disk, rod and spherical shapes, a transition in defect morphology moving from stationary beam to oscillating beam welds was detected and quantified.

36 MATERIALS SCIENCE↗

Interface stability of ultrasonic additively manufactured Zircaloy-4 during hydrothermal corrosion

Simulated pressurized water reactor conditions (330 °C, 15.6 MPa, ~20 ppb oxygen) without irradiation were used to investigate the hydrothermal corrosion behavior of ultrasonic additively manufactured Zircaloy-4 up to 1000 h. X-ray computed tomography allowed for visualization of defects from processing and their progression after corrosion experiments. The specimens were found to have clear variability in the mass change data, compared to typical wrought Zircaloy-4 specimens. The variation in the mass change after exposure was attributed to weld defects connected to the specimen surface which allowed ingress of oxidant into the samples. Defects visualized by computed tomography were found via metallography and characterized. In conclusion, ultrasonic additively manufactured Zircaloy-4 was found to have comparable corrosion behavior as wrought Zircaloy-4 for specimens which did not have clear surface defects along weld interfaces.

36 MATERIALS SCIENCE↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

1000 Soils Pilot Dataset, version 8, May 2025

This record hosts data generated by the 1000 Soils Pilot. Data will be updated as more become available. Please see the most recent data upload for current data. A beta visualization tool is available for some data types at https://shinyproxy.emsl.pnnl.gov/app/1000soils. Please submit any suggestions or comments through the 'contact' tab. We are actively working to improve visualizations and value all feedback. Data completed include: Geochemistry, texture, respiration, and enzyme activities FTICR-MS organic matter chemistry Microbial biomass C and N TOC/TDN of water-extractable OM X-ray computed tomography (derived metrics available here, raw data available upon request) Metagenomes; a variety of data formats are available upon request Soil hydraulic properties Data in progress: LC-MS/MS in development, timeline TBD, inquire for status 1000S_processed_BGC_summary.csv contains all available biogeochemical data; microbial biomass C and N; and TOC/TDN of water-extractable OM; and 1000S_Tomography.xslx contains a summary of data generated via X-ray computed tomography. icr_v2_corems2.csv contains FTICR-MS data processed by CoreMS version 2. These data are merged by formula across instrument runs to enable cross-sample comparisons. Technical replicates are merged by retaining peaks present in 2 out of 3 replicates. 1000Soils_Metadata_Site_Mastersheet_v1.csv contains site information. Soil Hydraulics_corrected_02042025.xlsx contains soil hydraulics information. Readme File_v4.xlsx is the readme file. Please contact the MONet project (monet.emsl@pnnl.gov) or Emily Graham (emily.graham@pnnl.gov) with questions. The following file and all raw data are available upon request: icr_by_mass_for_single_sample_analysis_only.csv contains FTICR-MS data processed by CoreMS and is intended for usage in the calculation of biochemical transformations within samples only. These data are not acceptable for cross-sample comparison of masses because they are from multiple instrument runs. For more information, please see: https://www.emsl.pnnl.gov/monet and https://sc-data.emsl.pnnl.gov/monet Acknowledgment: Soil data were provided by the Molecular Observation Network (MONet) at the Environmental Molecular Sciences Laboratory (https://ror.org/04rc0xn13), a DOE Office of Science user facility sponsored by the Biological and Environmental Research program under Contract No. DE-AC05-76RL01830. The work (proposal: 10.46936/10.25585/60008970) conducted by the U.S. Department of Energy, Joint Genome Institute (https://ror.org/04xm1d337), a DOE Office of Science user facility, is supported by the Office of Science of the U.S. Department of Energy operated under Contract No. DE-AC02-05CH11231. The Molecular Observation Network (MONet) database is an open, FAIR, and publicly available compilation of the molecular and microstructural properties of soil. Data in the MONet open science database can be found at https://sc-data.emsl.pnnl.gov/.

biogeochemistry↗

Non-Invasive Investigation of Bone Adaptation in Humans to Mechanical Loading

Experimental studies have identified peak cyclic forces, number of loading cycles, and loading rate as contributors to the regulation of bone metabolism. We have proposed a theoretical model that relates bone density to a mechanical stimulus derived from average daily cumulative peak cyclic 'effective' tissue stresses. In order to develop a non-invasive experimental model to test the theoretical model we need to: (1) monitor daily cumulative loading on a bone, (2) compute the internal stress state(s) resulting from the imposed loading, and (3) image volumetric bone density accurately, precisely, and reproducibly within small contiguous volumes throughout the bone. We have chosen the calcaneus (heel) as an experimental model bone site because it is loaded by ligament, tendon and joint contact forces in equilibrium with daily ground reaction forces that we can measure; it is a peripheral bone site and therefore more easily and accurately imaged with computed tomography; it is composed primarily of cancellous bone; and it is a relevant site for monitoring bone loss and adaptation in astronauts and the general population. This paper presents an overview of our recent advances in the areas of monitoring daily ground reaction forces, biomechanical modeling of the forces on the calcaneus during gait, mathematical modeling of calcaneal bone adaptation in response to cumulative daily activity, accurate and precise imaging of the calcaneus with quantitative computed tomography (QCT), and application to long duration space flight.

Whalen, R.↗

Identification of mechanisms driving heterogeneous void growth in ductile aluminum

Void growth plays a central role in ductile fracture, yet the specific mechanisms that control this remain obscure. Classical models, such as those proposed by Rice and Tracey in 1969, are able to capture average rates of void growth, but cannot capture the heterogeneity of individual void growth. Building on recent work, the present study employs laboratory-based diffraction contrast tomography and in-situ x-ray computed tomography to investigate the effect of grain structure and other microstructural factors on void growth in an Al-2219 alloy. Crystal plasticity finite element (CP-FE) modeling is used alongside experimental data to evaluate the contributions of local mechanical states, grain orientation, grain size, and neighboring microstructural features. No strong linear relationships are found with any of the considered descriptors and void growth rate. Potential complex nonlinear relationships are explored with the use of a random forest regression model, which identifies initial void volume, void aspect ratio, local normal stress state, local shear stress state, and local equivalent plastic strain (EQPS) as features that most improve void growth rate predictions. The combination of these analyses suggests that these features should be prioritized to improve models of void growth.

Diffraction contrast tomography (DCT)↗

Laser Powder Bed Fusion Manufactured Alloys 625 and 282 and Properties Relevant to Advanced Nuclear Components

Under the Advanced Materials and Manufacturing Technologies program, two Ni-based alloys fabricated by laser powder bed fusion (LPBF) have been evaluated: γ′-strengthened Haynes 282 and solution-strengthened Inconel 625. Large printing defects were observed in the LPBF 282 alloy fabricated using a Renishaw AM250 machine, likely due to particle spattering during printing. Annealing at 1,180°C for 1 h followed by 4 h at 800°C in a high density of 50 nm γ′-strengthening precipitates as well as partial recrystallization resulted in a bimodal grain distribution. Creep testing performed at 750°C revealed lower creep life and ductility for the LPBF 282 compared with wrought 282. X-ray computed tomography combined with optical and scanning electron microscopy microstructural characterization revealed crack formation during creep testing, initiated either from printing defects or from creep cavitation at grain boundaries. Printing defects were the likely reason for the lower creep performance of LPBF 282 and could be suppressed by optimizing the build configuration. Printing 625 on an EOS M290 machine using the recommended EOS parameters resulted in a very low defect density. Superior creep strength at 725°C was observed for the as-printed LPBF 625 along the build direction when compared with wrought 625. No defect larger than ~50 µm could be detected by X-ray computed tomography in the as-printed conditions and after creep testing for 1,000 h at 725°C and 150 MPa. Small, needle-like δ-phase precipitates were observed after creep testing for 100 h at 725°C and 200 MPa. The rapid formation of the γ phase is directly related to the initial Nb and Mo segregation in the LPBF 625 cell walls, and its effect on the alloy’s high-temperature performance will be evaluated. Solution annealing was carried out at 1,150°C for 1 h and led to full recrystallization of the alloy. A decrease in strength and increase in ductility were observed after solution annealing, and the alloy recrystallization resulted in isotropic tensile properties at room temperature, contrary to what was observed for the as-printed LPBF 625.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Petrology, Geochemistry, and Pairing of Lunar Meteorites from the Dominion Range

Introduction: During the 2018-2019 Antarctic Search for Meteorites (ANSMET) field season in the Dominion Range (DOM), 7 lunar meteorite stones were collected: DOM 18242 (15.1 g), DOM 18244 (25.1 g), DOM 18262 (6.8 g), DOM 18509 (16.5 g), DOM 18543 (13.6 g), DOM 18666 (45.9 g), and DOM 18678 (11.6 g). Here we present the initial results of electron microprobe and X-ray computed tomography (XCT) studies of these stones and look at the details of their petrography and mineral chemistry, as well as investigate possible pairing relationships, both with each other and with previously described lunar meteorites. Most of the work presented here is on the DOM 18509, 18543, and 18678 stones; subsamples of the other stones are in hand and similar measurements will be made on them by the time of the meeting. Methods: Textures in DOM 18509, DOM 18543, and DOM 18678 were characterized in 2D by optical microscopy, backscattered electron (BSE) imaging and elemental X-ray images on thin sections, as well as in 3D by X-ray computed tomography (XCT) on sample chips. Mineral compositions were assessed through a combination of wavelength dispersive spectroscopy EPMA (electron probe microanalysis) and x-ray mapping on the JEOL 8530 at NASA JSC. The bulk composition of all three meteorites was determined based on analyses of the fusion crust glass. XCT analyses were done on the Nikon XTH 320 at NASA JSC. ICP-MS data on bulk rock subsamples for each meteorite will be carried out in the near future. Results: The stones are all similar in macroscopic appearance with a dark aphanitic matrix hosting a variety of small- to medium-sized angular mineral and lithic fragments (often light colored in nature) [1,2]. Based on EPMA and XCT results, the three meteorites are polymict regolith breccias comprised of mineral, glass, and lithic clasts ranging up to several mm in length. Melt veins run through all three meteorite samples. Mineral clasts in all 3 stones are dominated by pyroxene and plagioclase (An82-96), with minor amounts of SiO2, olivine (Fo1-52), and FeTi-oxides. Pyroxene grains are mostly Fe-rich pigeonite and augite, and larger clasts are normally zoned and have fine exsolution lamellae. The lithic clasts in all stones consists of: (1) basalt clasts that contain zoned pyroxene, plagioclase laths, and ilmenite, with minor silica and Fe-rich olivine; (2) granulitic clasts; (3) anorthosite clasts; (4) Si-rich clasts that also contain ilmenite, troilite, high-Ca pyroxene, fayalite, and K-feldspar likely mesostasis from late stage basalts). All three meteorites contain glassy fusion crust that is highly vesicular, high in FeO and Al2O3 (15-17 wt% each), ferroan (Mg# of 23-24), and moderately rich in TiO2 (1.4-1.8 wt%). The composition of the fusion crust can serve as a proxy for the bulk meteorite composition and is identical within error for all three meteorites. Implications: The lithic and mineral clasts in all three stones are similar in clast population and assemblages as well as mineral chemistry. In addition, the fusion crust composition, a proxy for bulk composition, is within error of each other for all three stones. Thus DOM 18509, DOM 18543, and DOM 18678 are almost certainly paired. Based on similarities in macroscopic description as well as preliminary classification data [1,2], all 7 lunar stones from DOM are likely paired, though additional quantitative analyses are needed to confirm this. The presence of spherules and vesicular fusion crusts indicates that the DOM pairing group is a regolith breccia. The presence of basaltic and gabbroic clasts as well as more feldspathic materials, suggest that the regolith from which these meteorites formed contained a mixture of feldspathic highland material and mare material, suggesting a possible provenance near a marehighlands boundary. No evidence of KREEPy lithologies have been observed so far in these meteorites, however, future ICP-MS data on bulk rock chips for the stones will reveal any KREEP component if present. The DOM pairing group has many similarities to previously described lunar breccia meteorite MET 01210, however more detailed compositional data will be needed to make a definitive comparison.

R.A. Zeigler↗

Assessment of Internal Fabric of Particulate Materials

Particle arrangement and distribution within a soil matrix has long been recognized as having significant influence on the mechanical behavior of cohesionless soils. It is well known that two soil specimens having the same grain type (e.g., quartz, feldspar, etc.), same grain size distribution and relative density (or void ratio) can display completely different mechanical behavior. Because of the different fabric configurations in the otherwise similar specimens, they are likely to have different mechanical properties such as stress-strain response, anisotropy, dilatancy, etc. Soil Fabric is defined as the arrangement of particles, particle groups and associated pore space. In the literature, fabric analysis techniques are mainly classified as destructive (e.g., specimen stabilization, thin-sectioning, and microscopy), and nondestructive techniques (e.g., magnetic resonance imaging, ultrasonic testing, x-ray radiography, and computed tomography). Quantifying the void ratio and its distribution is the main parameter used to describe the fabric of particulate materials. This paper presents a comprehensive literature review of fabric analysis techniques applied to particulate materials. In addition, the results of a comprehensive investigation to quantify void ratio of sand specimens will be presented and discussed. The sand used in the experiments in a natural, uniform rounded to sub-rounded silica sand known as F-75 banding sand with mean particle size of 0.22 mm. Uniform specimens and specimens subjected to different axial-strain levels tested under triaxial and biaxial conditions are examined to evaluate void ratio evolution and its distribution using destructive thin-sectioning and nondestructive Computed Tomography (CT) techniques. Details of a new innovative polygon generation technique called Voronoi tessellation used to quantify void ratio of microscopic images of sand grains will be presented and compared to classical Oda's method. Finally, frequency distribution of void ratio calculated using CT analysis will be presented and discussed.

Alshibi, Khalid A.↗