Search NASA⌕ Search

SEARCH · Search NASA

Results for “constraint reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Constraining and Characterizing the Size of Atmospheric Rivers: A Perspective Independent From the Detection Algorithm

Abstract Atmospheric rivers (AR) are large and narrow filaments of poleward horizontal water vapor transport. Because of its direct relationship with horizontal vapor transport, extreme precipitation, and overall AR impacts over land, the AR size is an important characteristic that needs to be better understood. Current AR detection and tracking algorithms have resulted in large uncertainty in estimating AR sizes, with areas varying over several orders of magnitude among different detection methods. We develop and implement five independent size estimation methods to characterize the size of ARs that make landfall over the west coast of North America in the 1980–2017 period and reduce the range of size estimation from ARTMIP. ARs that originate in the Northwest Pacific (WP) (100°−180°E) have larger sizes and are more zonally oriented than those from the Northeast Pacific (EP) (180°−240°E). ARs become smaller through their life cycle, mainly due to reductions in their width. They also become more meridionally oriented toward the end of their life cycle. Overall, the size estimation methods proposed in this study provide a range of AR areas (between 7 × 10 11 and 10 13 m 2 ), that is, several orders of magnitude narrower than current methods estimation. This methodology can provide statistical constraints in size and geometry for the AR detection and tracking algorithms, and an objective insight for future studies about AR size changes under different climate scenarios.

54 ENVIRONMENTAL SCIENCES↗

Final report- UFL - RAPIDS2: A SciDAC Institute for Computer Science, Data, and Artificial Intelligence

The research initiatives supported by the U.S. Department of Energy (DOE) Grant DE-SC0022265 are fundamentally aimed at pioneering advanced machine learning (ML) techniques for scientific data compression within high-performance computing (HPC) environments. This comprehensive body of work addresses the critical challenge posed by the exponential growth of data generated by scientific simulations in domains such as fusion energy, climate modeling, and computational fluid dynamics (CFD). A core objective is to develop compression algorithms that achieve substantial data reduction—often by orders of magnitude—while rigorously ensuring the fidelity of both the primary data (PD) and scientifically crucial derived quantities of interest (QoI). The methodologies deployed under this grant integrate sophisticated deep learning architectures, prominently featuring autoencoders, advanced generative models like conditional diffusion, and hybrid learning techniques. Key innovations include the development of Guaranteed Autoencoders (GAE) and the Guaranteed Conditional Diffusion with Tensor Correction (GCDTC) framework, which provide explicit, instance-level error bounds on reconstructed data. Furthermore, specialized strategies such as nonlinear constraint satisfaction are employed to preserve the integrity of QoI, a vital requirement for the trustworthiness of downstream scientific analyses. This research also focuses on the design and implementation of scalable, GPU-accelerated software pipelines that seamlessly integrate into existing HPC workflows, ensuring both computational efficiency and practical applicability. The CAESAR framework, for example, unifies foundation and generative models to create an adaptive and efficient compression solution for spatio-temporal scientific data. Collectively, these efforts represent a significant advancement in mitigating the scientific data deluge, enabling more effective data management, accelerated scientific discovery, and optimized utilization of HPC resources.

97 MATHEMATICS AND COMPUTING↗

Relationship Between Tropical Cloud Feedback and Climatological Bias in Clouds

Abstract Global climate model (GCM) projections of future climate are uncertain largely due to a persistent spread in cloud feedback. This is despite efforts to reduce this model uncertainty through a variety of emergent constraints (ECs); with several studies suggesting an important role for present‐day biases in clouds. Here, we use three generations of GCMs to assess the value of climatological cloud metrics for constraining uncertainty in cloud feedback. We find that shortwave cloud radiative properties across the Southern Hemisphere extratropics are most robustly correlated with tropical cloud feedback (TCF). Using this relationship in conjunction with observations, we produce an EC that yields a TCF value of 0.52 ± 0.34 W/m 2 /K, which equates to a 34% reduction in uncertainty. Thus, we show that climatological cloud properties can be used to reduce uncertainty in how clouds will respond to future warming.

54 ENVIRONMENTAL SCIENCES↗

Post-extreme-event restoration using linear topological constraints and DER scheduling to enhance distribution system resilience

In this paper, a post-extreme-event restoration (PEER) algorithm is proposed to improve distribution system resilience. Linear topological constraints are proposed to ensure radial topology after N-k contingencies, possibly in multiple islands. The approach is made comprehensive by considering dispatchable distributed energy resources (DERs), non-dispatchable DERs, and demand responses, as well as on-load tap changers (OLTCs) and shunt capacitors. The goal is to minimize the accumulative expense caused by load reduction payment or penalty, as well as DER operation cost. As a result, the overall system will survive longer with higher resilience during an extreme event. To verify the effectiveness of the PEER algorithm, we proposed a resilience evaluation algorithm using Monte Carlo simulation (MCS) with reduced scenarios. This is based on a probabilistic model for generating random scenarios which consider the uncertainty of line faults and solar irradiance. Combined with the proposed PEER algorithm, this reduced-scenario MCS can evaluate the expected energy not served (EENS) which is an essential index for distribution system resilience. Case studies of the IEEE 33-bus and 123-bus test systems validate the proposed algorithm in reducing EENS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A flexible and differentiable coil proxy for stellarator equilibrium optimization

Balancing plasma performance and coil cost is a significant challenge when designing a stellarator power plant. Most current stellarator designs are produced through two-stage optimization: stage-1 for the equilibrium and stage-2 for a coil design that reproduces its magnetic configuration. Because few proxies connect both stages, two-stage optimization can produce plasmas that have high-quality physical properties but overly complex coils. In recent years, single-stage optimization has increasingly been used to optimize the plasma and coils simultaneously in order to improve the plasma–coil balance. However, all existing single-stage tools are specialized for filament coils, cannot model coil systems containing permanent magnets or dipole arrays, and continue to be challenged by numerical problems. The quasi-single-stage optimization finds a middle ground by integrating a coil optimization subproblem into stage-1 optimization. We present a flexible, differentiable coil complexity proxy based on the newly developed QUADCOIL coil optimization code. QUADCOIL is fast and can target realistic coil metrics and constraints that are unavailable to codes with comparable speed. We demonstrate the effectiveness and flexibility of the QUADCOIL proxy by presenting two QSS optimization studies. The first study produces a permanent magnet solution for the MUSE stellarator with 34% fewer magnets than previous solutions. The second study produces a coil solution for the ARIES-CS stellarator with 30% reductions in both peak and root-mean-square force.

Fu, Lanke [Princeton Plasma Physics Laboratory (PP↗

GT Flex: A Coordinated Multi-Building Pilot Study

Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rate Controlling in Low-Temperature Standard NH 3 -SCR: Implications from Operando EPR Spectroscopy and Reaction Kinetics

Here, a series of seven Cu/SSZ-13 catalysts with Si/Al = 6.7 are used to elucidate key rate-controlling factors during low-temperature standard ammonia-selective catalytic reduction (NH 3 -SCR), via a combination of SCR kinetics and operando electron paramagnetic resonance (EPR) spectroscopy. Strong Cu-loading-dependent kinetics, with Cu atomic efficiency increasing nearly by an order of magnitude, is found when per chabazite cage occupancy for Cu ion increases from ~0.04 to ~0.3. This is due mainly to the release of intercage Cu transfer constraints that facilitates the redox chemistry, as evidenced from detailed Arrhenius analysis. Operando EPR spectroscopy studies reveal strong connectivity between Cu-ion dynamics and SCR kinetics, based on which it is concluded that under low-temperature steady-state SCR, kinetically most relevant Cu species are those with the highest intercage mobility. Transient binuclear Cu species are mechanistically relevant species, but their splitting and cohabitation are indispensable for low-temperature kinetics.

catalytic reactions↗

Active Aerodynamic Load Control for Wind Turbines

The goal of this project was to develop and demonstrate an advanced dielectric barrier discharge (DBD) plasma actuator technology. We set out to demonstrate the efficacy and impact of the new actuator technology as a key component of an active load control system for wind turbines. A DBD plasma actuator consists of a thin layer of dielectric material separating a pair of offset electrodes. One of those electrodes is embedded between the dielectric layer and a non-conductive substrate, while the other is exposed to air. When driven by an appropriate high voltage waveform, the device ionizes the air near the surface of the dielectric and adjacent to the exposed electrode. Collisions between the ions in the plasma and neutral air molecules result in a wall-jet – a region of induced air velocity that can be used to modify the flow around a lifting body. Use of the device near the trailing edge of a wind turbine blade, designed in such a way as to amplify the effects of the flow-modifying device, can result in large changes to the global forces experienced by the blade. Because of the fast response time of the device, it can allow the turbine to react in real time to changes in the wind associated with turbulence, wind shear, gusts, and the like, when paired with appropriate sensors and control algorithms. The goal of this project was to increase the capacity of the device to induce velocity on its surface at the levels required by large, utility-scale wind turbines. The first technical goal was to increase the induced velocity from the current industry-best of about 4 m/s to 10 m/s by modifying the electrical waveform used to drive the device and by introducing a semi-conductive surface coating to control electrostatic charge build-up on the surface. The second goal was to use the device to modify the lift on a representative airfoil in a wind tunnel, demonstrating a reduction in lift coefficient of 0.2 or better. The third goal was to produce an actuator-induced velocity of 20 m/s. Alongside our partners at the University of Texas at Dallas, we also applied modern, advanced design methods to optimize the impact of the technology on the design of wind turbines. We also had planned to install a segmented, active load control system on a test turbine to demonstrate the ability to reduce unsteady aerodynamic forces on the turbine associated with changes in the wind. The highest induced velocity achieved during this research was 11 m/s. However, practical design constraints limited the change in lift coefficient to about 0.12 for a representative airfoil in the wind tunnel at a Reynolds number of 400,000. The primary conclusion is that the plasma actuator control authority remains insufficient for practical purposes when extrapolated to Reynolds numbers over 1 million. The potential impact of the active lift control concept was evaluated through detailed simulations for three wind turbine sizes: a 3.4MW onshore turbine, a 10MW offshore turbine, and a 15MW offshore turbine. A feedback control system was designed for each turbine within two scenarios: one where the active lift control is used as a retrofit capability on the baseline design, and the other where the designers were permitted to “upscale” the turbines in order increase annual energy production. The levelized cost of energy was then evaluated for the range of turbine sizes and design configuration. It was found that the LCOE reduction associated with active lift control fell in the range of 0.7% to 7.2%, with the highest reduction associated with upscaling the 3.4MW turbine.

17 WIND ENERGY↗

The kinetics of the PuO 2 to Pu 2 O 3 conversion

Here in an oxidizing environment, the oxide formed on plutonium (Pu) metal is composed of a plutonium dioxide (PuO 2 ) top layer and a thin cubic plutonium sesquioxide (Pu 2 O 3 ) middle layer. In a reducing environment, the PuO 2 layer auto-reduces to cubic Pu 2 O 3 . The speed and extent of this conversion depend on the combination of temperature and time. While PuO 2 provides a strong diffusion barrier against unwanted Pu corrosion by gaseous species (like hydrogen), Pu 2 O 3 does not, since its crystal structure has chains of oxygen vacancies. The kinetics of the PuO 2 reduction are, therefore, of fundamental interest and enable researchers to better protect Pu from corrosion. In this report, the oxygen-diffusion-limited kinetics of the dioxide to sesquioxide conversion were obtained by dynamically heating a PuO 2 -covered Pu sample from 294 to 418 K in a high-vacuum vessel equipped with an in situ spectroscopic ellipsometer. The physical/chemical constraints in the conversion process were combined with the ellipsometry method of multi-sample analysis to track the percentage of PuO 2 and to compute the extent of Pu 2 O 3 formation. The resulting diffusion coefficients were compared against and then combined with complementary literature data to produce a comprehensive set of kinetic parameters for reliably modeling oxide conversion over a larger temperature range than spanned by prior studies. The extracted thermal activation energy barrier (43.7 kJ/mol) and pre-exponential factor (5.0 × 10 -10 cm 2 /s) for the oxygen-diffusion-limited process can be used to accurately model the PuO 2 to Pu 2 O 3 transformation in vacuum and/or inert gas applications.

36 MATERIALS SCIENCE↗

Galaxy clustering in the DESI Legacy Survey and its imprint on the CMB

ABSTRACT We use data from the DESI Legacy Survey imaging to probe the galaxy density field in tomographic slices covering the redshift range 0 < z < 0.8. After careful consideration of completeness corrections and galactic cuts, we obtain a sample of 4.9 × 107 galaxies covering 17 739 deg2. We derive photometric redshifts with precision σz/(1 + z) = 0.012−0.015, and compare with alternative estimates.1 Cross-correlation of the tomographic galaxy maps with Planck maps of cosmic microwave background (CMB) temperature and lensing convergence probe the growth of structure since z = 0.8. The signals are compared with a fiducial Planck ΛCDM model, and require an overall scaling in amplitude of Aκ = 0.901 ± 0.026 for the lensing cross-correlation and AISW = 0.984 ± 0.349 for the temperature cross-correlation, interpreted as the integrated Sachs–Wolfe effect. The ISW amplitude is consistent with the fiducial Λ cold dark matter (ΛCDM) prediction, but lies significantly below the prediction of the AvERA model of Rácz et al., which has been proposed as an alternative explanation for cosmic acceleration. Within ΛCDM, our low amplitude for the lensing cross-correlation requires a reduction either in fluctuation normalization or in matter density compared to the Planck results, so that $\Omega _\mathrm{ m}^{0.78}\sigma _8=0.297\pm 0.009$. In combination with the total amplitude of CMB lensing, this favours a shift mainly in density: Ωm = 0.274 ± 0.024. We discuss the consistency of this figure with alternative evidence. A conservative compromise between lensing and primary CMB constraints would require Ωm = 0.296 ± 0.006, where the 95 per cent confidence regions of both probes overlap.

Hang, Qianjun↗

Microgrid Tiered Circuits Effects for a Planned Housing Community in Puerto Rico

Puerto Rico faced a double strike from hurricanes Irma and Maria in 2017. The resulting damage required a comprehensive rebuild of electric infrastructure. There are plans and pilot projects to rebuild with microgrids to increase resilience. This paper provides a techno-economic analysis technique and case study of a potential future community in Puerto Rico that combines probabilistic microgrid design analysis with tiered circuits in building energy modeling. Tiered circuits in buildings allow electric load reduction via remote disconnection of non-critical circuits during an emergency. When coupled to a microgrid, tiered circuitry can reduce the chances of a microgrid's storage and generation resources being depleted. The analysis technique is applied to show 1) Approximate cost savings due to a tiered circuit structure and 2) Approximate cost savings gained by simultaneously considering resilience and sustainability constraints in the microgrid optimization. The analysis technique uses a resistive capacitive thermal model with load profiles for four tiers (tier 1-3 and non-critical loads). Three analyses were conducted using: 1) open-source software called Tiered Energy in Buildings and 2) the Microgrid Design Toolkit. For a fossil fuel based microgrid 30% of the total microgrid costs of 1.18 million USD were calculated where the non-tiered case keeps all loads 99.9% available and the tiered case keeps tier 1 at 99.9%, tier 2 at 95%, tier 3 at 80% availability, with no requirement on non-critical loads. The same comparison for a sustainable microgrid showed 8% cost savings on a 5.10 million USD microgrid due to tiered circuits. The results also showed 6-7% cost savings when our analysis technique optimizes sustainability and resilience simultaneously in comparison to doing microgrid resilience analysis and renewables net present value analysis independently. Though highly specific to our case study, similar assessments using our analysis technique can elucidate value of tiered circuits and simultaneous consideration of sustainability and resilience in other locations.

building energy modeling↗

Unitarization from geometry

We study the perturbative unitarity of scattering amplitudes in general dimensional reductions of Yang–Mills theories and general relativity on closed internal manifolds. For the tree amplitudes of the dimensionally reduced theory to have the expected high-energy behavior of the higher-dimensional theory, the masses and cubic couplings of the Kaluza–Klein states must satisfy certain sum rules that ensure there are nontrivial cancellations between Feynman diagrams. These sum rules give constraints on the spectra and triple overlap integrals of eigenfunctions of Laplacian operators on the internal manifold and can be proven directly using Hodge and eigenfunction decompositions. One consequence of these constraints is that there is an upper bound on the ratio of consecutive eigenvalues of the scalar Laplacian on closed Ricci-flat manifolds with special holonomy. This gives a sharp bound on the allowed gaps between Kaluza–Klein excitations of the graviton that also applies to Calabi–Yau compactifications of string theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Co-Design of Multijunction Photoelectrochemical Devices for Unassisted CO 2 Reduction to Multicarbon Products

Photoelectrochemical (PEC) CO 2 reduction (PEC CO 2 R) is a prospective approach for utilizing solar energy to synthesize a variety of carbon-containing chemicals and fuels, the most valuable of which are multicarbon (C 2+ ) products, such as ethylene and ethanol. While these products can be produced with high faradaic efficiency using Cu, this occurs over a relatively narrow potential range, which, in turn, imposes constraints on the design of a device for PEC CO 2 R. Herein, we used continuum-scale modeling to simulate the solar-to-C 2+ (STC 2+ ) efficiency of PEC CO 2 R devices fed with CO 2 -saturated, 0.1 M CsHCO 3 . We then explored how cell architecture and the use of single or dual photoelectrode(s) alters the optimal combination of photoelectrode bandgaps for high STC 2+ efficiency. Ultimately, this work provides guidance for the co-design of the device architecture and photoelectrode bandgaps required to achieve high STC 2+ efficiency. The insights gained are then used to identify systems that yield the highest amount of C 2+ products throughout the day and year.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing Power Line Undergrounding Decisions under Varying Wildfire Risk and Weather Scenarios

Abstract—The threat of wildfire ignitions from electric power equipment has led utilities to increasingly turn to preemptive power shutoffs, which, while effective in reducing grid-induced wildfire risk, can cause significant load loss. Undergrounding power lines is an alternative strategy for preventing grid-induced wildfires. However, undergrounding lines is costly, so an efficient undergrounding plan must balance reductions in wildfire risk and load loss with the cost of undergrounding lines. We propose a robust optimization model to identify which power lines to underground to maximize load served while limiting wildfire risk across a range of wildfire risk and weather scenarios. Since solving this problem may be computationally heavy for large power grids and many operating scenarios, we present a delayed constraint generation algorithm to iteratively add scenarios until an optimal solution is found. We evaluate the performance of this framework on the RTS-GMLC with scenarios representing a year of operating conditions and compare it with a stochastic programming formulation. Our results indicate that our undergrounding model is successful in reducing load shed and risk compared to baseline cases in which no mitigation action is taken and only power shutoffs are implemented (no undergrounding). The robust formulation also reduces more load shed than the stochastic formulation in the most extreme scenarios. Index Terms—grid resilience, optimization, transmission systems, underground power lines, wildfire risk.

Taylor, S. [Department of Electrical and Computer ↗

Extending Shared Socioeconomic Pathways to Future Water Supply In-frastructure Scenarios: A Case Study of San Antonio, TX

Datasets supporting findings and visualization behind Okoye and McManamay (2025) Extending Shared Socioeconomic Pathways to Future Water Supply Infrastructure Scenarios: A Case Study of San Antonio, TX. Environmental Research Communications, DOI: 10.57931/2563186 These datasets contains the results of a site selection analysis for municipal water supply planning across multiple Shared Socioeconomic Pathways (SSPs 1–5) and hard scenario classification of water systems in San Antonio, TX. It includes data at the resolution of individual surface water supply sources (COMIDs) and integrates a wide range of hydrologic, socioeconomic, infrastructural, and scenario-based planning variables. Please refer to the README file provided in Files for more details. Descriptions of the datasets are provided below. Dataset(s) Descriptions: Dataset_SSP1_SSP4.xlsx - Contains data used for site selection optimization under SSP1 to SSP4. This dataset was generated based on multi-indicator computations (e.g., WAI, WQI, ERI, WTC, WIC), scenario demand projections, and resource and spatial constraints, excluding new reservoir values. Dataset_SSP5.xlsx - Used for site optimization under SSP5. Unlike Dataset_SSP1_SSP4, this dataset includes new reservoir features with updated calculations of WAI, WTC, and WIC to reflect the added infrastructure and supply potential. hard_classification.xlsx - Provides the scenario classification output for each site. Includes both the initial scenario classification based on Euclidean Distance and adjusted classifications based on 30% change reduction BAU.zip - Zipped folder of .shp files showing spatially optimized water supply sites per SSP under the Business-As-Usual (BAU) water demand strategy LowGW.zip - Zipped folder of .shp files showing optimized site selections under the Low Groundwater strategy

geospatial↗

Optimization of key energy and performance metrics for drug product manufacturing

During the development of pharmaceutical manufacturing processes, detailed systems-based analysis and optimization are required to control and regulate critical quality attributes within specific ranges, to maintain product performance. As discussions on carbon footprint, sustainability, and energy efficiency are gaining prominence, the development and utilization of these concepts in pharmaceutical manufacturing are seldom reported, which limits the potential of pharmaceutical industry in maximizing key energy and performance metrics. Based on an integrated modeling and techno-economic analysis framework previously developed by the authors, this study presents the development of a combined sensitivity analysis and optimization approach to minimize energy consumption while maintaining product quality and meeting operational constraints in a pharmaceutical process. The optimal input process conditions identified were validated against experiments and good agreement resulted between simulated and experimental data. Here, the results also allowed for a comparison of the capital and operational costs for batch and continuous manufacturing schemes under nominal and optimized conditions. Using the nominal batch operations as a basis, the optimized batch operation results in a 71.7% reduction of energy consumption, whereas the optimized continuous case results in an energy saving of 83.3%.

59 BASIC BIOLOGICAL SCIENCES↗

Examining the Net Revenue and Downstream Flow Impact Trade-Offs for a Network of Cascading, Small-Scale Hydropower Facilities: Preprint

In this work, we used a price-taker model to investigate the trade-offs between net revenue and downstream flow impacts for a network of small, cascading hydro facilities. The network consisted of 36 facilities, each with a small amount of local storage (between 2 and 45 minutes). Generator sizes ranged between 0.5 and 1 MW, nominal, and the total capacity of the network was 33.5 MW. We used a multi-integer linear programing model to maximize the net revenue of the combined network subject to operating and environmental constraints. Net revenue optimizations relied on historic price data, and dry, typical, and wet years were studied to help ensure robustness. Energy and ancillary service sales were included in the net revenue calculations, and both unit commitment and dispatch simulations were performed. We found that limiting the downstream flows to ±50% of the river’s natural flows had a negligible impact on net revenues (<1% reduction), irrespective of hydrologic conditions, and even when downstream flows were limited to ±5%, net revenues were only impacted by 4%. These outcomes are significant because they demonstrate how an array of small-scale hydropower facilities can be operated to have minimal impact on natural stream flows—addressing a critical environmental concern.

downstream flow↗

Probing the limits of cosmological information from the Lyman- α forest 2-point correlation functions

The standard cosmological analysis with the Lyα forest relies on a continuum fitting procedure that suppresses information on large scales and distorts the three-dimensional correlation function on all scales. In this work, we present the first cosmological forecasts without continuum fitting distortion in the Lyα forest, focusing on the recovery of large-scale information. Using idealized synthetic data, we compare the constraining power of the full shape of the Lyα forest auto-correlation and its cross-correlation with quasars using the baseline continuum fitting analysis versus the true continuum. We find that knowledge of the true continuum enables a ∼ 10% reduction in uncertainties on the Alcock-Paczyński (AP) parameter and the matter density, Ω m . We also explore the impact of large-scale information by extending the analysis up to separations of 240 h -1 Mpc along and across the line of sight. The combination of these analysis choices can recover significant large-scale information, yielding up to a ∼ 15% improvement in AP constraints. This improvement is analogous to extending the Lyα forest survey area by ∼ 40%.

Lyman alpha forest↗