Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Uncertainty Aware Deep Learning for Fault Prediction Using Multivariate Time Series Signals

The superconducting radio-frequency cavities are a crucial component of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. When a cavity faults, beam delivery to experimental end users is disrupted. Prediction of cavity faults prior to onset is essential to reduce operation and maintenance costs. In this work, a parallel long short-term memory (LSTM)-convolution neural network (CNN)-based deep learning (DL) model is proposed to predict impending faults using pre-fault signals. Further, we introduce an uncertainty quantification approach using Monte Carlo dropout with the LSTM-CNN model to ascertain confidence in the prediction. The model was tested using multivariate time series signals from stable cavity operations and before faults. Initial results show that on the test dataset, the model can identify impending faults before their onset with an average 10-fold cross validation accuracy of 97.39% and a standard deviation of 0.12% using a 100-ms time window. It is also observed that the model performs better as the prediction time moves closer to the fault onset. For additional context, we compare the performance of the model with three machine-learning-based (ML) fault prediction models. Our proposed parallel LSTM-CNN-based DL method shows better performance than the ML-based methods.

Rahman, Md Monibor↗

Image-Guided Radiotherapy in Near Real Time With Intensity-Modulated Radiotherapy Megavoltage Treatment Beam Imaging

Purpose: To utilize image-guided radiotherapy (IGRT) in near real time by obtaining and evaluating the online positions of implanted fiducials from continuous electronic portal imaging device (EPID) imaging of prostate intensity-modulated radiotherapy (IMRT) delivery. Methods and Materials: Upon initial setup using two orthogonal images, the three-dimensional (3D) positions of all implanted fiducial markers are obtained, and their expected two-dimensional (2D) locations in the beam's-eye-view (BEV) projection are calculated for each treatment field. During IMRT beam delivery, EPID images of the megavoltage treatment beam are acquired in cine mode and subsequently analyzed to locate 2D locations of fiducials in the BEV. Simultaneously, 3D positions are estimated according to the current EPID image, information from the setup portal images, and images acquired at other gantry angles (the completed treatment fields). The measured 2D and 3D positions of each fiducial are compared with their expected 2D and 3D setup positions, respectively. Any displacements larger than a predefined tolerance may cause the treatment system to suspend the beam delivery and direct the therapists to reposition the patient. Results: Phantom studies indicate that the accuracy of 2D BEV and 3D tracking are better than 1 mm and 1.4 mm, respectively. A total of 7330 images from prostate treatments were acquired and analyzed, showing a maximum 2D displacement of 6.7 mm and a maximum 3D displacement of 6.9 mm over 34 fractions. Conclusions: This EPID-based, real-time IGRT method can be implemented on any external beam machine with portal imaging capabilities without purchasing any additional equipment, and there is no extra dose delivered to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Designing Functionality and Stimuli-Responsiveness into Azlactone-Based Polymers

There continues to be considerable interest in stimuli-responsive and reactive polymers for drug delivery vehicles or gene therapy agents, as well as soft interfaces capable of being patterned or chemically modified to serve as a biomaterial coating. One class of materials with particularly interesting potential are polymers based on 2-vinyl-4,4-dimethylazlactone (VDMA), which react rapidly with various nucleophiles without producing a leaving group or requiring a catalyst. In this contribution we describe the synthesis and characterization of polymers and copolymers incorporating VDMA, and their conjugation with biomolecules. By using reversible addition fragmentation chain transfer (RAFT) polymerization we are able to produce well-defined VDMA-containing homopolymers and block copolymers having tailored molecular weights and narrow molecular weight distributions. The conversion of these materials into polyelectrolytes and bioconjugates can be monitored in real time using infrared spectroscopy. Poly(VDMA)-based brushes can be synthesized by RAFT polyermization using surface-tethered chain transfer agents, and these brushes can be modified in situ and structural changes monitored using neutron reflectometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ADVANCED HIGH SPEED PROGRAMMABLE PREFORMING

Polymer-matrix composites offer greater stiffness and strength per unit weight than conventional materials resulting in new opportunities for lightweighting of automotive and heavy vehicles. Other benefits include design flexibility, less corrosion susceptibility, and the ability to tailor properties to specific load requirements. However, widespread implementation of structural composites requires lower-cost manufacturing processes than those that are currently available. Advanced, directed-fiber preforming processes have demonstrated exceptional value for rapid preforming of large, glass-reinforced, automotive composite structures. This is due to process flexibility and inherently low material scrap rate. Hence directed fiber performing processes offer a low cost manufacturing methodology for producing preforms for a variety of structural automotive components. This paper describes work conducted at the Oak Ridge National Laboratory (ORNL), focused on the development and demonstration of a high speed chopper gun to enhance throughput capabilities. ORNL and the Automotive Composites Consortium (ACC) revised the design of a standard chopper gun to expand the operational envelope, enabling delivery of up to 20kg/min. A prototype unit was fabricated and used to demonstrate continuous chopping of multiple roving at high output over extended periods. In addition fiber handling system modifications were completed to sustain the high output the modified chopper affords. These hardware upgrades are documented along with results of process characterization and capabilities assessment.

36 MATERIALS SCIENCE↗

TU-FG-201-03: Automatic Pre-Delivery Verification Using Statistical Analysis of Consistencies in Treatment Plan Parameters by the Treatment Site and Modality

Purpose: A novel computer software system, namely APDV (Automatic Pre-Delivery Verification), has been developed for verifying patient treatment plan parameters right prior to treatment deliveries in order to automatically detect and prevent catastrophic errors. Methods: APDV is designed to continuously monitor new DICOM plan files on the TMS computer at the treatment console. When new plans to be delivered are detected, APDV checks the consistencies of plan parameters and high-level plan statistics using underlying rules and statistical properties based on given treatment site, technique and modality. These rules were quantitatively derived by retrospectively analyzing all the EBRT treatment plans of the past 8 years at authors’ institution. Therapists and physicists will be notified with a warning message displayed on the TMS computer if any critical errors are detected, and check results, confirmation, together with dismissal actions will be saved into database for further review. Results: APDV was implemented as a stand-alone program using C# to ensure required real time performance. Mean values and standard deviations were quantitatively derived for various plan parameters including MLC usage, MU/cGy radio, beam SSD, beam weighting, and the beam gantry angles (only for lateral targets) per treatment site, technique and modality. 2D-based rules of combined MU/cGy ratio and averaged SSD values were also derived using joint probabilities of confidence error ellipses. The statistics of these major treatment plan parameters quantitatively evaluate the consistency of any treatment plans which facilitates automatic APDV checking procedures. Conclusion: APDV could be useful in detecting and preventing catastrophic errors immediately before treatment deliveries. Future plan including automatic patient identify and patient setup checks after patient daily images are acquired by the machine and become available on the TMS computer. This project is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Solid-State Fault Current Limiter Development: Design and Testing Update of a 15kV SSCL Power Stack

The Solid-State Fault Current Limiter (SSCL) is a promising technology that can be applied to utility power delivery systems to address the problem of increasing fault currents associated with load growth. As demand continues to grow, more power is added to utility system either by increasing generator capacity or by adding distributed generators, resulting in higher available fault currents, often beyond the capabilities of the present infrastructure. The SSCL is power-electronics based equipment designed to work with the present utility system to address this problem. The SSCL monitors the line current and dynamically inserts additional impedance into the line in the event of a fault being detected. The SSCL is based on a modular design and can be configured for 5kV through 69kV systems at nominal current ratings of 1000A to 4000A. Results and Findings This report provides the final test results on the development of 15kV class SSCL single phase power stack. The scope of work included the design of the modular standard building block sub-assemblies, the design and manufacture of the power stack and the testing of the power stack for the key functional tests of continuous current capability and fault current limiting action. Challenges and Objectives Solid-State Current Limiter technology impacts a wide spectrum of utility engineering and operating personnel. It addresses the problems associated with load growth both at Transmission and Distribution class networks. The design concept is pioneering in terms of developing the most efficient and compact power electronics equipment for utility use. The initial test results of the standard building blocks are promising. The independent laboratory tests of the power stack are promising. However the complete 3 phase system needs rigorous testing for performance and reliability. Applications, Values, and Use The SSCL is an intelligent power-electronics device which is modular in design and can provide current limiting or current interrupting capabilities. It can be applied to variety of applications from distribution class to transmission class power delivery grids and networks. It can also be applied to single major commercial and industrial loads and distributed generator supplies. The active switching of devices can be further utilized for protection of substation transformers. The stress on the system can be reduced substantially improving the life of the power system. It minimizes the voltage sag by speedy elimination of heavy fault currents and promises to be an important element of the utility power system. DOE Perspective This development effort is now focused on a 15kV system. This project will help mitigate the challenges of increasing available fault current. DOE has made a major contribution in providing a cost effective SSCL designed to integrate seamlessly into the Transmission and Distribution networks of today and the future. Approach SSCL development program for a 69kV SSCL was initiated which included the use of the Super GTO advanced semiconductor device which won the 2007 R&D100 Award. In the beginning, steps were identified to accomplish the economically viable design of a 69kV class Solid State Current Limiter that is extremely reliable, cost effective, and compact enough to be applied in urban transmission. The prime thrust in design and development was to encompass the 1000A and the 3000A ratings and provide a modular design to cover the wide range of applications. The focus of the project was then shifted to a 15kV class SSCL. The specifications for the 15kV power stack are reviewed. The design changes integrated into the 15kV power stack are discussed. In this Technical Update the complete project is summarized followed by a detailed test report. The power stack independent high voltage laboratory test requirements and results are presented. Keywords Solid State Current Limiter, SSCL, Fault Current Limiter, Fault Current Controller, Power electronics controller, Intelligent power-electronics Device, IED

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quality Assessment in Oncology

The movement to improve healthcare quality has led to a need for carefully designed quality indicators that accurately reflect the quality of care. Many different measures have been proposed and continue to be developed by governmental agencies and accrediting bodies. However, given the inherent differences in the delivery of care among medical specialties, the same indicators will not be valid across all of them. Specifically, oncology is a field in which it can be difficult to develop quality indicators, because the effectiveness of an oncologic intervention is often not immediately apparent, and the multidisciplinary nature of the field necessarily involves many different specialties. Existing and emerging comparative effectiveness data are helping to guide evidence-based practice, and the increasing availability of these data provides the opportunity to identify key structure and process measures that predict for quality outcomes. The increasing emphasis on quality and efficiency will continue to compel the medical profession to identify appropriate quality measures to facilitate quality improvement efforts and to guide accreditation, credentialing, and reimbursement. Given the wide-reaching implications of quality metrics, it is essential that they be developed and implemented with scientific rigor. The aims of the present report were to review the current state of quality assessment in oncology, identify existing indicators with the best evidence to support their implementation, and propose a framework for identifying and refining measures most indicative of true quality in oncologic care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lipid nanoparticle topology regulates endosomal escape and delivery of RNA to the cytoplasm

RNA therapeutics have the potential to resolve a myriad of genetic diseases. Lipid nanoparticles (LNPs) are among the most successful RNA delivery systems. Expanding their use for the treatment of more genetic diseases hinges on our ability to continuously evolve the design of LNPs with high potency, cellular-specific targeting, and low side effects. Overcoming the difficulty of releasing cargo from endocytosed LNPs remains a significant hurdle. Here, in this study, we investigate the fundamental properties of nonviral RNA nanoparticles pertaining to the activation of topological transformations of endosomal membranes and RNA translocation into the cytosol. We show that, beyond composition, LNP fusogenicity can be prescribed by designing LNP nanostructures that lower the energetic cost of fusion and fusion–pore formation with a target membrane. The inclusion of structurally active lipids leads to enhanced LNP endosomal fusion, fast evasion of endosomal entrapment, and efficacious RNA delivery. For example, conserving the lipid make-up, RNA–LNPs havingcuboplexnanostructures are significantly more efficacious at endosomal escape than traditionallipoplexconstructs.

59 BASIC BIOLOGICAL SCIENCES↗

Broadly neutralizing humanized SARS-CoV-2 antibody binds to a conserved epitope on Spike and provides antiviral protection through inhalation-based delivery in non-human primates

The COVID-19 pandemic represents a global challenge that has impacted and is expected to continue to impact the lives and health of people across the world for the foreseeable future. The rollout of vaccines has provided highly anticipated relief, but effective therapeutics are required to further reduce the risk and severity of infections. Monoclonal antibodies have been shown to be effective as therapeutics for SARS-CoV-2, but as new variants of concern (VoC) continue to emerge, their utility and use have waned due to limited or no efficacy against these variants. Furthermore, cumbersome systemic administration limits easy and broad access to such drugs. As well, concentrations of systemically administered antibodies in the mucosal epithelium, a primary site of initial infection, are dependent on neonatal Fc receptor mediated transport and require high drug concentrations. To reduce the viral load more effectively in the lung, we developed an inhalable formulation of a SARS-CoV-2 neutralizing antibody binding to a conserved epitope on the Spike protein, ensuring pan-neutralizing properties. Administration of this antibody via a vibrating mesh nebulization device retained antibody integrity and resulted in effective distribution of the antibody in the upper and lower respiratory tract of non-human primates (NHP). In comparison with intravenous administration, significantly higher antibody concentrations can be obtained in the lung, resulting in highly effective reduction in viral load post SARS-CoV-2 challenge. This approach may reduce the barriers of access and uptake of antibody therapeutics in real-world clinical settings and provide a more effective blueprint for targeting existing and potentially emerging respiratory tract viruses.

60 APPLIED LIFE SCIENCES↗

Continued Evaluation of the Pulse-Echo Ultrasonic Instrument for Critical Velocity Determination during Hanford Tank Waste Transfer Operations - 12518

The delivery of Hanford double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be governed by specific Waste Acceptance Criteria that are identified in ICD 19 - Interface Control Document for Waste Feed. Waste must be certified as acceptable before it can be delivered to the WTP. The fluid transfer velocity at which solid particulate deposition occurs in waste slurry transport piping (critical velocity) is a key waste parameter that must be accurately characterized to determine if the waste is acceptable for transfer to the WTP. In 2010 Washington River Protection Solutions and the Pacific Northwest National Laboratory began evaluating the ultrasonic PulseEcho instrument to accurately identify critical velocities in a horizontal slurry transport pipeline for slurries containing particles with a mean particle diameter of >50 micrometers. In 2011 the PulseEcho instrument was further evaluated to identify critical velocities for slurries containing fast-settling, high-density particles with a mean particle diameter of <15 micrometers. This two-year evaluation has demonstrated the ability of the ultrasonic PulseEcho instrument to detect the onset of critical velocity for a broad range of physical and rheological slurry properties that are likely encountered during the waste feed transfer operations between the Hanford tank farms and the WTP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Passive Water Assurance Delivery System

This report provides an analysis and evaluation of proposed design improvements to the internal water delivery system of NASA’s passive vegetable growing system. The VEGGIE system is designed to provide fresh vegetables and psychological benefits for astronauts aboard the International Space Station. Preliminary testing conducted by NASA for the VEGGIE system revealed flaws in the water delivery system. In these tests, the interface between the plants and the water reservoir failed to provide passive water delivery through the system both in microgravity experiments and experiments conducted on Earth. Our team’s goal was to fix this interface such that water can be passively delivered from the water reservoir to the plant rooting pillows to grow vegetative crops from seed to harvest. The system requirements outlined by NASA include: minimal total mass, on-demand passive water delivery, same dimensions as existing fixtures, minimal pressure on system to prevent leaking, zero mold growth, minimal swelling or clogging for non-flammable capillary materials, pressure stabilization between the water reservoir and plant pillow bags, even dispersal of water during initial priming, minimal bubble obstruction of capillary interface, maximum gas availability to plant roots, growth in a mixed artificial media (50:50 Arcillite:Fafard #2), and to avoid overwatering and drought conditions for plants. The major proposed design improvements are to use a single-interface capillary cord design to directly connect the water reservoir to the plant-rooting pillows, and to alter the water reservoir to model a propellant management device (PMD) in order to ensure consistent and long term watering for the VEGGIE system. The plant rooting pillow required minimal changes outside of replacing the capillary mat on the bottom of the pillow with O-ring insertion points the single-interface capillary system. - Research was conducted to determine which materials are able to uptake water through capillary action to grow Outredgeous Lettuce plants from seed to harvest. The primary requirements to be met by the team's design and evaluation of the capillary interface were: continuous passive watering for 90 days using non-flammable capillary materials and a peak water delivery rate of 30 mL/hr./0.15 m 2 . The results of the team's experimentation showed that the capillary material Nomex displayed the highest capillary water delivery potential with a maximum flow rate of 3.6 mL/hr. The Nomex capillary systems were the only capillary material to consistently grow Outredgeous Lettuce plants from seed to harvest, and displayed the highest average flow rate for multiple experiment sets. The Nomex material was previously incorporated into the VEGGIE system using a matted version of the capillary material, though the team recommends using a cord configuration in the single-interface capillary system for greater system stability. Nomex has proven to be a promising material, as it has passed both health and fire standards for use aboard the International Space Station. PMDs are made of materials that utilize surface tension and adhesive forces to overcome adverse accelerations to improve stability and ensure fluid delivery. PMDs are typically used in fuel tanks to ensure fuel delivery. The team recommends using a sponge PMD in order to mitigate bubble obstruction, decrease system weight, and ensure reliable water delivery to the capillary interface. The PMD water reservoir requires a rigid water reservoir and a vent tube for pressure stabilization. Since PMD’s cannot be tested in 1-G (Earth conditions), further theoretical modeling and testing is required for the proposed water reservoir design. The intent of this proposed system is to passively water plants in microgravity, though the technology is not limited to microgravity applications. The testing at The Ohio State University has proven that the design is highly effective on Earth, demonstrating that it could serve as a simple water delivery system in home and office applications. This would make vegetative crops more accessible in all indoor applications, thereby improving indoor air quality and occupant comfort. Additionally, this technology has great potential to be utilized in greenhouse plant production, cutting back on more sophisticated watering system energy and time requirements.

Alexandria Jensen↗

Generalizable Class Solutions for Treatment Planning of Spinal Stereotactic Body Radiation Therapy

Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency. Methods and Materials: We examined 91 patients treated with spinal SBRT at our institution. Treatment plans were categorized by lesion location, clinical target volume (CTV) configuration, and dose fractionation scheme, and then analyzed to determine the technically achievable dose gradient. A radial cord expansion was subtracted from the CTV to yield a planning CTV (pCTV) construct for plan evaluation. We reviewed the treatment plans with respect to target coverage, dose gradient, integral dose, conformality, and maximum cord dose to select the best plans and develop a set of class solutions. Results: The class solution technique generated plans that maintained target coverage and improved conformality (1.2-fold increase in the 95% van't Riet Conformation Number describing the conformality of a reference dose to the target) while reducing normal tissue integral dose (1.3-fold decrease in the volume receiving 4 Gy (V{sub 4Gy}) and machine output (19% monitor unit (MU) reduction). In trials of planning efficiency, the class solution technique reduced treatment planning time by 30% to 60% and MUs required by {approx}20%: an effect independent of prior planning experience. Conclusions: We have developed a set of class solutions for spinal SBRT that incorporate a pCTV metric for plan evaluation while yielding dosimetrically superior treatment plans with increased planning efficiency. Our technique thus allows for efficient, reproducible, and high-quality spinal SBRT treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Freely scalable and reconfigurable optical hardware for deep learning

Abstract As deep neural network (DNN) models grow ever-larger, they can achieve higher accuracy and solve more complex problems. This trend has been enabled by an increase in available compute power; however, efforts to continue to scale electronic processors are impeded by the costs of communication, thermal management, power delivery and clocking. To improve scalability, we propose a digital optical neural network (DONN) with intralayer optical interconnects and reconfigurable input values. The path-length-independence of optical energy consumption enables information locality between a transmitter and a large number of arbitrarily arranged receivers, which allows greater flexibility in architecture design to circumvent scaling limitations. In a proof-of-concept experiment, we demonstrate optical multicast in the classification of 500 MNIST images with a 3-layer, fully-connected network. We also analyze the energy consumption of the DONN and find that digital optical data transfer is beneficial over electronics when the spacing of computational units is on the order of $$>10\,\upmu $$ > 10 μ m.

42 ENGINEERING↗

High density photobiorefineries with optimized light/CO2 delivery and product extraction

In this work we aimed to develop a transformative concept for biofuel producing microalgae photobioreactors. The concept is based on: (1) the delivery of light along low-cost sheet waveguides and (2) CO 2 delivery and product extraction using porous hollow fibers. This new approach to bioenergy production could enable ultra-compact reactors with: very high densities (thereby requiring less land), more efficient solar energy-to-photosynthetic product conversion, and dramatically lower operational energy costs and water usage. Compact reactors built as single, self-contained units could also be deployed to any location where sunlight is available enabling them to be co-located with carbon-sources. Over the course of the project we were able to construct a prototype reactor and demonstrate direct ethylene production from un-harvested organisms at a rate 5x that of a standard bench-top reactor. We also developed several operational technologies including the use of surface scatterers to enhance light delivery and UV light to provide in-situ sterilization. We were able to demonstrate continuous operation of the reactor for as long as 3 weeks.

09 BIOMASS FUELS↗

Evaluation of Roadmap to Achieve Energy Delivery Systems Cybersecurity

The Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) Cybersecurity for Energy Delivery Systems (CEDS) program is currently evaluating the Roadmap to Achieve Energy Delivery Systems Cybersecurity document that sets a vision and outlines a set of milestones. The milestones are divided into five strategic focus areas that include: 1. Build a Culture of Security; 2. Assess and Monitor Risk; 3. Develop and Implement New Protective Measures to Reduce Risk; 4. Manage Incidents; and 5. Sustain Security Improvements. The most current version of the roadmap was last updated in September of 2016. Sandia National Laboratories (SNL) has been tasked with revisiting the roadmap to update the current state of energy delivery systems cybersecurity protections. SNL is currently working with previous and current partners to provide feedback on which of the roadmap milestones have been met and to identify any preexisting or new gaps that are not addressed by the roadmap. The specific focus areas SNL was asked to evaluate are: 1. Develop and Implement New Protective Measures to Reduce Risk and 2. Sustain Security Improvements. SNL has formed an Industry Advisory Board (IAB) to assist in answering these questions. The IAB consists of previous partners on past CEDS funded efforts as well as new collaborators that have unique insights into the current state of cybersecurity within energy delivery systems. The IAB includes asset owners, utilities and vendors of control systems. SNL will continue to maintain regular communications with the IAB to provide various perspectives on potential future updates to further improve the breadth of cybersecurity coverage of the roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

External Sources of Water for Mercury's Putative Ice Deposits

Radar images have revealed the possible presence of ice deposits in Mercury's polar regions. Although thermal models indicate that water ice can be stable in permanently shaded regions near Mercury's poles, the ultimate source of the water remains unclear. We use stochastic models and other theoretical methods to investigate the role of external sources in supplying Mercury with the requisite amount of water. By extrapolating the current terrestrial influx of interplanetary dust particles to that at Mercury, we find that continual micrometeoritic bombardment of Mercury over the last 3.5 byr could have resulted in the delivery of (3-60) x 10(exp 16) grams of water ice to the permanently shaded regions at Mercury's poles (equivalent to an average ice thickness of 0.8-20 m). Erosion by micrometeoritic impact on exposed ice deposits could reduce the above value by about a half. For comparison, the current ice deposits on Mercury are believed to be somewhere between approx. 2 and 20 m thick. Using a Monte Carlo model to simulate the impact history of Mercury, we find that asteroids and comets can also deliver an amount of water consistent with the observations. Impacts from Jupiter-family comets over the last 3.5 billion years can supply (0.1-200) x 10(exp 16) grams of water to Mercury's polar regions (corresponding to ice deposits 0.05-60 m thick), Halley-type comets can supply (0.2-20) x 10(exp 16) grams of water to the poles (0.07-7 m of ice), and asteroids can provide (0.4-20) x 10(exp 16) grams of water to the poles (0.1-8 m of ice). Although all these external sources are nominally sufficient to explain the estimated amount of ice currently at Mercury's poles, impacts by a few large comets and/or asteroids seem to provide the best explanation for both the amount and cleanliness of the ice deposits on Mercury. Despite their low population estimates in the inner solar system, Jupiter-family comets are particularly promising candidates for delivering water to Mercury because they have a larger volatile content than asteroids and more favorable orbital and impact characteristics than Halley-type comets.

Moses, Julianne I.↗

Critical Experiments at Sandia National Laboratories: Technical Meeting on Low-Power Critical Facilities and Small Reactors

Sandia National Laboratories (SNL) has conducted radiation effects testing for the Department of Energy (DOE) and other contractors supporting the DOE since the 1960's. Over this period, the research reactor facilities at Sandia have had a primary mission to provide appropriate nuclear radiation environments for radiation testing and qualification of electronic components and other devices. The current generation of reactors includes the Annular Core Research Reactor (ACRR), a water-moderated pool-type reactor, fueled by elements constructed from UO2-BeO ceramic fuel pellets, and the Sandia Pulse Reactor III (SPR-III), a bare metal fast burst reactor utilizing a uranium-molybdenum alloy fuel. The SPR-III is currently defueled. The SPR Facility (SPRF) has hosted a series of critical experiments. A purpose-built critical experiment was first operated at the SPRF in the late 1980's. This experiment, called the Space Nuclear Thermal Propulsion Critical Experiment (CX), was designed to explore the reactor physics of a nuclear thermal rocket motor. This experiment was fueled with highly-enriched uranium carbide fuel in annular water-moderated fuel elements. The experiment program was completed and the fuel for the experiment was moved off-site. A second critical experiment, the Burnup Credit Critical Experiment (BUCCX) was operated at Sandia in 2002. The critical assembly for this experiment was based on the assembly used in the CX modified to accommodate low-enriched pin-type fuel in water moderator. This experiment was designed as a platform in which the reactivity effects of specific fission product poisons could be measured. Experiments were carried out on rhodium, an important fission product poison. The fuel and assembly hardware for the BUCCX remains at Sandia and is available for future experimentation. The critical experiment currently in operation at the SPRF is the Seven Percent Critical Experiment (7uPCX). This experiment is designed to provide benchmark reactor physics data to support validation of the reactor physics codes used to design commercial reactor fuel elements in an enrichment range above the current 5% enrichment cap. A first set of critical experiments in the 7uPCX has been completed. More experiments are planned in the 7uPCX series. The critical experiments at Sandia National Laboratories are currently funded by the US Department of Energy Nuclear Criticality Safety Program (NCSP). The NCSP has committed to maintain the critical experiment capability at Sandia and to support the development of a critical experiments training course at the facility. The training course is intended to provide hands-on experiment experience for the training of new and re-training of practicing Nuclear Criticality Safety Engineers. The current plans are for the development of the course to continue through the first part of fiscal year 2011 with the development culminating is the delivery of a prototype of the course in the latter part of the fiscal year. The course will be available in fiscal year 2012.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗