Search NASA⌕ Search

SEARCH · Search NASA

Results for “control methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods of Controlling the Loop Heat Pipe Operating Temperature

The operating temperature of a loop heat pipe (LHP) is governed by the saturation temperature of its compensation chamber (CC); the latter is in turn determined by the balance among the heat leak from the evaporator to the CC, the amount of subcooling carried by the liquid returning to the CC, and the amount of heat exchanged between the CC and ambient. The LHP operating temperature can be controlled at a desired set point by actively controlling the CC temperature. The most common method is to cold bias the CC and use electric heater power to maintain the CC set point temperature. The required electric heater power can be large when the condenser sink is very cold. Several methods have been developed to reduce the control heater power, including coupling block, heat exchanger and separate subcooler, variable conductance heat pipe, by-pass valve with pressure regulator, secondary evaporator, and thermoelectric converter. The paper discusses the operating principles, advantages and disadvantages of each method.

Ku, Jentung↗

Aggregate Load Controllers and Associated Methods

Aggregate load controllers and associated methods are described. According to one aspect, a method of operating an aggregate load controller includes using an aggregate load controller having an initial state, applying a stimulus to a plurality of thermostatic controllers which are configured to control a plurality of respective thermostatic loads which receive electrical energy from an electrical utility to operate in a plurality of different operational modes, accessing data regarding a response of the thermostatic loads as a result of the applied stimulus, using the data regarding the response, determining a value of at least one design parameter of the aggregate load controller, and using the determined value of the at least one design parameter, configuring the aggregate load controller to control amounts of the electrical energy which are utilized by the thermostatic loads.

47 OTHER INSTRUMENTATION↗

Dynamic Performance Enhancement for Nonlinear Stochastic Systems Using RBF Driven Nonlinear Compensation with Extended Kalman Filter

In this paper, a novel hybrid control method is proposed to enhance the control performance of the PI based control system for a class of nonlinear and non-Gaussian stochastic dynamic processes with unmeasurable states. Firstly, to enhance the tracking performance of the PI controller where the PI parameters are fixed in many actual control systems, the compensative signal is formed using the extended Kalman filter(EKF) based state estimator and driven by the radial basis function (RBF) neural network based compensator. In addition, the weights of RBF is trained to minimize the entropy criterion of tracking error as the process is subjected to non-Gaussian disturbances. Meanwhile, since the precise statistical property of noises is hard to obtain for many industrial processes, the kernel density estimation (KDE) technique is employed in this paper to estimate the entropy. The convergence of RBF network is discussed and the stability of the resulted closed-loop hybrid control system is analyzed in mean square sense. Finally, a numerical example and a practical system testing are given to illustrate the effectiveness of the proposed control method.

stochastic systems, PI Controller, Entropy, Extend↗

Trajectory specification for high capacity air traffic control

Method and system for analyzing and processing information on one or more aircraft flight paths, using a four-dimensional coordinate system including three Cartesian or equivalent coordinates (x, y, z) and a fourth coordinate .delta. that corresponds to a distance estimated along a reference flight path to a nearest reference path location corresponding to a present location of the aircraft. Use of the coordinate .delta., rather than elapsed time t, avoids coupling of along-track error into aircraft altitude and reduces effects of errors on an aircraft landing site. Along-track, cross-track and/or altitude errors are estimated and compared with a permitted error bounding space surrounding the reference flight path.

Paielli, Russell A.↗

Method to Control Crimping Processes Using Ultrasonic Transmission Analysis

A method of crimping wires includes positioning a wire/terminal combination between first and second crimp forming tools. A force is applied to the crimp forming tools to deform the wire/terminal combination. The method further includes measuring ultrasonic energy that is transmitted across the wire/terminal combination as the terminal is being deformed. A rate of change of the magnitude of the ultrasonic energy is also determined as the terminal is being deformed. The crimping process is terminated if the rate of change of the magnitude of the ultrasonic energy falls below a predefined threshold level. Data gathered during the crimping process can also be utilized to determine if a faulty crimp has occurred.

Cramer, Karl Elliott↗

Viability of Cathodic Protection for Preventing Corrosion of Stainless Steel 316H in Molten LiF-NaF-KF

Molten fluoride salts are candidate heat transfer fluids in a number of applications such as generation IV molten salt nuclear reactors and concentrated solar power plants. However, a chief concern in the design of these systems is the corrosion of structural materials that come in contact with these molten salts. Redox control methods such as the purification of salt, the addition of active elements, and applied electrochemical potential can be efficient methods for preventing the corrosion of structural materials in molten fluoride salts. Applied electrochemical potential as a redox control method for application in molten fluoride salts has rarely been explored. This study seeks to understand the viability of impressed current cathodic protection (CP) at various currents as a redox control method to prevent corrosion of stainless steel 316H in molten LiF-NaF-KF (FLiNaK) salt. Results show that application of CP can be an effective method to prevent corrosion of SS316H in molten FLiNaK salt, but the applied current will have to be optimized to prevent undesirable side effects such as reduction of salt constituents, salt deposition on electrodes, etc.

Materials Science↗

Rotating switching strategy for power converters

Systems and methods for operating a power converter with a plurality of inverter blocks with silicon carbide MOSFETs are provided. A DC to AC converter can include a plurality of inverter blocks. Each inverter block can include a plurality of switching devices. A control method can include identifying one of a plurality of switching patterns for operation of the inverter block for each inverter block. Each switching pattern can include a plurality of switching commands. The control method can further include controlling each inverter block based on the identified switching pattern for the inverter block. The control method can further include rotating the switching patterns among the plurality of inverter blocks.

Dong, Dong↗

Controls Algorithms, Models, and Stability Assessments of the RCS and TVC systems on Mars Ascent Vehicle

This paper presents a control systems overview of the Mars Ascent Vehicle (MAV) control design and stability analysis with two separate control methods: Thrust Vector Control (TVC) based control using main engine thrust and Reaction Control System (RCS) via thrusters. A pole-placement TVC controller is proposed to address quickly peaking thrust produced by the MAV solid propulsion engine. The controllerutilizes real-time parameter estimation to calculate control gains using an online pole-placement method. The pole-placement technique allows the controller to maintain constant stability margins throughout the flight under changing parameters and rapidly peaking thrust. A mathematical stability proof via Lyapunov inequality and Nichols method is demonstrated to support the stability of the method. In addition to the TVC control, a phase-plane based RCS control logic is applied to the vehicle for roll control during ascent and all axes during coast phases of flight. The logic implemented is an on-off type logic that applies pre-determined thrusters firings in reference to boundary parameters of pointing and rate error chosen to balance desired pointing with stability. A describing function methodology is applied to the non-linear phase plane loop response to determine linear stability across all flight phases. The controller additionally applies command alteration logic to output signals to account for RCS hardware limitations. The following paper will provide the methodology for controller implementation of the TVC and RCS, and provide a summary of results of the MAV performance applying the aforementioned control design.

Han Woong Bae↗

Advanced Guidance and Control Project for Reusable Launch Vehicles

The goals of this project are to significantly reduce the time and cost associated with guidance and control design for reusable launch vehicles, and to increase their safety and reliability. Success will lead to reduced cycle times during vehicle design and to reduced costs associated with flying to new orbits, with new payloads, and with modified vehicles. Success will also lead to more robustness to unforeseen circumstances in flight thereby enhancing safety and reducing risk. There are many guidance and control methods available that hold some promise for improvement in the desired areas. Investigators are developing a representative set of independent guidance and control methods for this project. These methods are being incorporated into a high-fidelity off is being conducted across a broad range of flight requirements. The guidance and control methods that perform the best will have demonstrated the desired qualities.

Hanson, John M.↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

Development of an Active Flow Control Technique for an Airplane High-Lift Configuration

This study focuses on Active Flow Control methods used in conjunction with airplane high-lift systems. The project is motivated by the simplified high-lift system, which offers enhanced airplane performance compared to conventional high-lift systems. Computational simulations are used to guide the implementation of preferred flow control methods, which require a fluidic supply. It is first demonstrated that flow control applied to a high-lift configuration that consists of simple hinge flaps is capable of attaining the performance of the conventional high-lift counterpart. A set of flow control techniques has been subsequently considered to identify promising candidates, where the central requirement is that the mass flow for actuation has to be within available resources onboard. The flow control methods are based on constant blowing, fluidic oscillators, and traverse actuation. The simulations indicate that the traverse actuation offers a substantial reduction in required mass flow, and it is especially effective when the frequency of actuation is consistent with the characteristic time scale of the flow.

Shmilovich, Arvin↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Indirect learning control for nonlinear dynamical systems

In a previous paper, learning control algorithms were developed based on adaptive control ideas for linear time variant systems. The learning control methods were shown to have certain advantages over their adaptive control counterparts, such as the ability to produce zero tracking error in time varying systems, and the ability to eliminate repetitive disturbances. In recent years, certain adaptive control algorithms have been developed for multi-body dynamic systems such as robots, with global guaranteed convergence to zero tracking error for the nonlinear system euations. In this paper we study the relationship between such adaptive control methods designed for this specific class of nonlinear systems, and the learning control problem for such systems, seeking to converge to zero tracking error in following a specific command repeatedly, starting from the same initial conditions each time. The extension of these methods from the adaptive control problem to the learning control problem is seen to be trivial. The advantages and disadvantages of using learning control based on such adaptive control concepts for nonlinear systems, and the use of other currently available learning control algorithms are discussed.

Ryu, Yeong Soon↗

Systems and methods for controlling an industrial asset in the presence of a cyber-attack

Systems and methods are provided for the control of an industrial asset, such as a power generating asset. Accordingly, a cyber-attack model predicts a plurality of operational impacts on the industrial asset resulting from a plurality of potential cyber-attacks. The cyber-attack model also predicts a corresponding plurality of potential mitigation responses. In operation, a cyber-attack impacting at least one component of the industrial asset is detected via the cyber-attack neutralization module and a protected operational impact of the cyber-attack is identified based on the cyber-attack model. The cyber-attack neutralization module selects at least one mitigation response of the plurality of mitigation responses based on the predicted operational impact and an operating state of the industrial asset is altered based on the selected mitigation response.

D'Amato, Fernando Javier↗

Experimental study on two-dimensional free-flying robot satellite model

The experimental study on a control method for a free flying space robotic arm was treated by means of a two-dimensional laboratory model. The main target is to develop a new control method for trajectory tracking or target capturing, considering dynamical interaction between the manipulator arm and the base vehicle in space micro-gravity environment. In order to simulate the micro-gravity environment mechanically, a laboratory model of a robot satellite supported on air bearings was developed. The model comprises a base equipped with power and air supplies and a two-link manipulator arm. This model has relatively low gravitational and frictional disturbance in planar motion. An on-line resolved motion rate control scheme with vision feedback is developed for experimenting capture operations. The scheme utilizes the Generalized Jacobian Matrix. In experiment, the acceleration environment of the model is evaluated firstly, then target capture operations are examined. The manipulator can properly chase and capture both a standing target and a moving target in spite of complex satellite/manipulator dynamical interactions. The experimental results confirm the validity of the Generalized Jacobian Matrix concept and the proposed control method.

Umetani, Yoji↗