Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

QProR: An Efficient Framework for Quantity-of-Interest Based Progressive Retrieval with Guaranteed Error Control

Scientific applications generate an unprecedented volume of data, overwhelming the network and file systems’ bandwidth and posing challenges for efficient and scalable data retrieval and analysis. Progressive data compression offers a promising solution by enabling on-demand retrieval at reduced size. However, existing progressive methods either fail to bound the errors in essential quantities of interest (QoIs) derived from raw data or suffer from suboptimal retrieval efficiency. In this work, we propose QProR, an efficient QoI-based progressive framework that optimizes progressive retrieval for target QoIs. Our key contributions include: (1) a systematic framework that integrates error-controlled lossy compressors with bitplane encoding while decoupling the two processes for high flexibility and adaptability; (2) a novel weighted bitplane encoding method which incorperates QoI knowledge into data refactoring to enhance retrieval efficiency; (3) an optimized retrieval strategy that accounts for the varying impacts of different variables on multivariate QoIs; (4) comprehensive evaluations using six real-world datasets from multiple scientific applications and thorough comparisons against state of the arts. Experimental results demonstrate that QProR achieves up to 80.38% reduction in the retrieval size under the same requested QoI error tolerance, when compared with the best-performing existing methods. When transferring 384 GB of scientific data to remote sites, QProR delivers up to 1.68 × speedup in the end-to-end data transfer performance.

Li, Wenbo [University of Kentucky]↗

WE-G-BRE-09: Targeted Radiotherapy Enhancement During Accelerated Partial Breast Irradiation (ABPI) Using Controlled Release of Gold Nanoparticles (GNPs)

Purpose: Several studies have demonstrated low rates of local recurrence with brachytherapy-based accelerated partial breast irradiation (APBI). However, long-term outcomes on toxicity (e.g. telangiectasia), and cosmesis remain a major concern. The purpose of this study is to investigate the dosimetric feasibility of using targeted non-toxic radiosensitizing gold nanoparticles (GNPs) for localized dose enhancement to the planning target volume (PTV) during APBI while reducing dose to normal tissue. Methods: Two approaches for administering the GNPs were considered. In one approach, GNPs are assumed to be incorporated in a micrometer-thick polymer film on the surface of routinely used mammosite balloon applicators, for sustained controlled in-situ release, and subsequent treatment using 50-kVp Xoft devices. In case two, GNPs are administered directly into the lumpectomy cavity e.g. via injection or using fiducials coated with the GNP-loaded polymer film. Recent studies have validated the use of fiducials for reducing the PTV margin during APBI with 6 MV beams. An experimentally determined diffusion coefficient was used to determine space-time customizable distribution of GNPs for feasible in-vivo concentrations of 43 mg/g. An analytic calculational approach from previously published work was employed to estimate the dose enhancement due to GNPs (2 and 10 nm) as a function of distance up to 1 cm from lumpectomy cavity. Results: Dose enhancement due to GNP was found to be about 130% for 50-kVp x-rays, and 110% for 6-MV external beam radiotherapy, 1 cm away from the lumpectomy cavity wall. Higher customizable dose enhancement could be achieved at other distances as a function of nanoparticle size. Conclusion: Our preliminary results suggest that significant dose enhancement can be achieved to residual tumor cells targeted with GNPs during APBI with electronic brachytherapy or external beam therapy. The findings provide a useful basis for developing nanoparticle-aided APBI, with potential to significantly reduce normal tissue/skin toxicity.

60 APPLIED LIFE SCIENCES↗

Subplane-based Control Rod Decusping Techniques for the 2D/1D Method in MPACT

The MPACT transport code is being jointly developed by Oak Ridge National Laboratory and the University of Michigan to serve as the primary neutron transport code for the Virtual Environment for Reactor Applications Core Simulator. MPACT uses the 2D/1D method to solve the transport equation by decomposing the reactor model into a stack of 2D planes. A fine mesh flux distribution is calculated in each 2D plane using the Method of Characteristics (MOC), then the planes are coupled axially through a 1D NEM-P$_3$ calculation. This iterative calculation is then accelerated using the Coarse Mesh Finite Difference method. One problem that arises frequently when using the 2D/1D method is that of control rod cusping. This occurs when the tip of a control rod falls between the boundaries of an MOC plane, requiring that the rodded and unrodded regions be axially homogenized for the 2D MOC calculations. Performing a volume homogenization does not properly preserve the reaction rates, causing an error known as cusping. The most straightforward way of resolving this problem is by refining the axial mesh, but this can significantly increase the computational expense of the calculation. The other way of resolving the partially inserted rod is through the use of a decusping method. This paper presents new decusping methods implemented in MPACT that can dynamically correct the rod cusping behavior for a variety of problems.

Graham, Aaron M↗

Three-Dimensional Conformal Radiation Therapy for Esophageal Squamous Cell Carcinoma: Is Elective Nodal Irradiation Necessary?

Purpose: To evaluate the local control, survival, and toxicity associated with three-dimensional conformal radiotherapy (3D-CRT) for squamous cell carcinoma (SCC) of the esophagus, to determine the appropriate target volumes, and to determine whether elective nodal irradiation is necessary in these patients. Methods and Materials: A prospective study of 3D-CRT was undertaken in patients with esophageal SCC without distant metastases. Patients received 68.4 Gy in 41 fractions over 44 days using late-course accelerated hyperfractionated 3D-CRT. Only the primary tumor and positive lymph nodes were irradiated. Isolated out-of-field regional nodal recurrence was defined as a recurrence in an initially uninvolved regional lymph node. Results: All 53 patients who made up the study population tolerated the irradiation well. No acute or late Grade 4 or 5 toxicity was observed. The median survival time was 30 months (95% confidence interval, 17.7-41.8). The overall survival rate at 1, 2, and 3 years was 77%, 56%, and 41%, respectively. The local control rate at 1, 2, and 3 years was 83%, 74%, and 62%, respectively. Thirty-nine of the 53 patients (74%) showed treatment failure. Seventeen of the 39 (44%) developed an in-field recurrence, 18 (46%) distant metastasis with or without regional failure, and 3 (8%) an isolated out-of-field nodal recurrence only. One patient died of disease in an unknown location. Conclusions: In patients treated with 3D-CRT for esophageal SCC, the omission of elective nodal irradiation was not associated with a significant amount of failure in lymph node regions not included in the planning target volume. Local failure and distant metastases remained the predominant problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Shrinkage Assessed by Volumetric MRI in Long-Term Follow-Up After Fractionated Stereotactic Radiotherapy of Nonfunctioning Pituitary Adenoma

Purpose: To evaluate tumor control and side effects associated with fractionated stereotactic radiotherapy (FSRT) in the management of residual or recurrent nonfunctioning pituitary adenomas (NFPAs). Methods and Materials: We assessed exact tumor volume shrinkage in 16 patients with NFPA after FSRT. All patients had previously undergone surgery. Gross tumor volume (GTV) was outlined on contrast-enhanced magnetic resonance imaging (MRI) before and median 63 months (range, 28-100 months) after FSRT. MRI was performed as an axial three-dimensional gradient echo T1-weighted sequence at 1.6-mm slice thickness without gap (3D MRI). Results: Mean tumor size of all 16 pituitary adenomas before treatment was 7.4 mL (3.3-18.9 mL). We found shrinkage of the treated pituitary adenoma in all patients. Within a median follow-up of 63 months (28-100 months) an absolute mean volume reduction of 3.8 mL (0.9-12.4 mL) was seen. The mean relative size reduction compared with the volume before radiotherapy was 51% (22%-95%). Shrinkage measured by 3D MRI was greater at longer time intervals after radiotherapy. A strong negative correlation between the initial tumor volume and the absolute volume reduction after FSRT was found. There was no correlation between tumor size reduction and patient age, sex, or number of previous surgeries. Conclusions: By using 3D MRI in all patients undergoing FSRT of an NFPA, tumor shrinkage is detected. Our data demonstrate that volumetric assessment based on 3D MRI adds additional information to routinely used radiological response measurements. After FSRT a mean relative size reduction of 51% can be expected within 5 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conservative fourth-order finite-volume Vlasov–Poisson solver for axisymmetric plasmas in cylindrical (r,v r ,v θ ) phase space coordinates

In this paper, a fourth-order finite-volume Vlasov–Poisson algorithm is developed for simulating axisymmetric plasma configurations in ( r , v r , v θ ) phase space coordinates. The Vlasov equation for cylindrical phase space coordinates is cast into conservation-law form and is discretized on a structured grid. The conservative finite-volume discretization is based on fifth-order upwind reconstructions of the distribution function and a fourth-order quadrature rule that accounts for transverse variations of fluxes along control volume surfaces. High-order specular reflection boundary conditions enable high-fidelity treatment of plasma distribution functions at the axis and at wall boundaries. The numerical method is applied to simulate a confined uniform neutral gas to assess convergence properties for an equilibrium system in which effects of finite-temperature and acceleration due to centrifugal and Coriolis forces are present. The discretization is also applied to a Z-pinch configuration to study electrostatic ion confinement and the dynamics of the associated breathing mode. Simulations show that the ion distribution function exhibits non-Maxwellian features and that a temperature anisotropy develops and is sustained. Finally, the finite-volume implementation is demonstrated to converge at fourth-order for both applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FVCOM-plume – A Three-dimensional Lagrangian Outfall Plume Dilution and Transport Model for Dynamic Tidal Environments: Model Development

Although numerous steady-state effluent plume dilution models are in use, their application in tidal environments remains a challenge. Three-dimensional dynamic circulation models are also inadequate, often due to the lack of required resolution and simplifying assumptions. To overcome these limitations, we present FVCOM-plume—an outfall plume dilution and transport model that operates within the Finite Volume Coastal Ocean Model (FVCOM) framework. It provides simultaneous inclusion of near-field dilution and far-field plume transport processes. The near-field is based on UM3 model using Lagrangian Control Volume approach to compute buoyant plume trajectory and dilution from multiport diffusers. The far-field uses neutrally buoyant particles with point masses and the random walk method to solve unsteady advection-diffusion processes. A density kernel approach is used to compute concentrations at point locations and analyze far-field plume characteristics. The results demonstrate the ability of FVCOM-plume to simultaneously capture near-field and far-field effluent plume dynamics in tidal environments.

Plume Dilution Models↗

Performance of Nitrile-Containing Anions in Task-Specific Ionic Liquids for Improved CO2/N2 Separation

This work explores the performance of a series of ionic liquids that incorporate a nitrile-containing anion paired to 1-alkyl-3-methylimidazolium cations in tailoring the selectivity and permeance of supported ionic liquid membranes for CO2/N2 separations. The permeance and selectivity of three ionic liquids, each with an increasing number of nitrile groups in the anion (i.e., two, three, and four), were measured using a non-steady-state permeation method. By predictably varying the molar volume and viscosity of the ionic liquids, we show that the solubility, selectivity, and permeance can be optimized for CO2/N2 separation through controlled introduction of the nitrile functionality into the anion. Of the three nitrile-based ionic liquids studied, 1-ethyl-3-methylimidazolium tetracyanoborate, [emim][B(CN)4], showed the highest permeance with a value of 2.55 10 9 mol/(m2 Pa s), a magnitude 30% higher than that of the popular ionic liquid [emim][Tf2N]. This same nitrile-bearing ionic liquid also exhibited a high CO2/N2 selectivity of approximately 53. Additionally, the carbon dioxide solubility for each ionic liquid was measured at room temperature with [emim][B(CN)4] again exhibiting the highest CO2 solubility. Results from our study of the nitrile-based ionic liquids can be rationalized in terms of regular solution theory wherein the selectivity and permeance of a given SILM system are largely determined by the molar volume and viscosity of the corresponding ionic liquid phase.

59 BASIC BIOLOGICAL SCIENCES↗

Probing effect of solvent concentration on glass transition and sub-T{sub g} structural relaxation in polymer solvent mixtures: The case of polystyrene-toluene system

A novel experimental method for the analysis of volume relaxation induced by solvents in glassy polymers is presented. A gravimetric technique is used to evaluate the isothermal solvent mass uptake at controlled increasing/decreasing solvent pressure at constant rate. Fundamental properties of the solvent/polymer system can be obtained directly, and models can be applied, combining both nonequilibrium thermodynamics and mechanics of volume relaxation contribution. The fundamental case of polystyrene and toluene mixtures are thus accounted for, and various experimental conditions have been explored, varying the temperature, and spanning over different pressure increase/decrease rates. The results obtained allowed to evaluate the isothermal second order transition induced by solvent sorption, as well as the determination of the effect of the pressure rate. Therefore, this work proposes a new standard for the characterization and the understanding of the relaxational behavior of glassy polymers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-183: Feasibility of Extreme Dose Escalation for Glioblastoma Multiforme Using 4π Radiotherapy

Purpose: GBM recurrence primarily occurs inside or near the high-dose radiation field of original tumor site requiring greater than 100 Gy to significantly improve local control. We utilize 4π non-coplanar radiotherapy to test the feasibility of planning target volume (PTV) margin expansions or extreme dose escalations without incurring additional radiation toxicities. Methods: 11 GBM patients treated with VMAT to a prescription dose of 59.4 Gy or 60 Gy were replanned with 4π. Original VMAT plans were created with 2 to 4 coplanar or non-coplanar arcs using 3 mm hi-res MLC. The 4π optimization, using 5 mm MLC, selected and inverse optimized 30 beams from a candidate pool of 1162 beams evenly distributed through 4π steradians. 4π plans were first compared to clinical plans using the same prescription dose. Two more studies were then performed to respectively escalate the GTV and PTV doses to 100 Gy, followed by a fourth plan expanding the PTV by 5 mm and maintaining the prescription dose. Results: The standard 4π plan significantly reduced (p<0.01) max and mean doses to critical structures by a range of 47.0–98.4% and 61.0–99.2%, respectively. The high dose PTV/high dose GTV/expanded PTV studies showed a reduction (p<0.05) or unchanged* (p>0.05) maximum dose of 72.1%/86.7%/77.1% (chiasm), 7.2%*/27.7%*/30.7% (brainstem), 39.8%*/84.2%/51.9%* (spinal cord), 69.0%/87.0%/66.9% (L eye), 76.2%/88.1%/84.1% (R eye), 95.0%/98.6%/97.5% (L lens), 93.9%/98.8%/97.6% (R lens), 74.3%/88.5%/72.4% (L optical nerve), 80.4%/91.3%/75.7% (R optical nerve), 64.8%/84.2%/44.9%* (L cochlea), and 85.2%/93.0%/78.0% (R cochlea), respectively. V30 and V36 for both brain and (brain - PTV) were reduced for all cases except the high dose PTV plan. PTV dose coverage increased for all 4π plans. Conclusion: Extreme dose escalation or further margin expansion is achievable using 4π, maintaining or reducing OAR doses. This study indicates that clinical trials employing 4π delivery using prescription doses up to 100 Gy are feasible. Funding support partially contributed by Varian.

60 APPLIED LIFE SCIENCES↗

SU-E-T-352: Why Is the Survival Rate Low in Oropharyngeal Squamous Cell Carcinoma?

Purpose: Tumors are composed of a large number of clonogens that have the capability of indefinite reproduction. Even when there is complete clinical or radiographic regression of the gross tumor mass after treatment, tumor recurrence can occur if the clonogens are not completely eradicated by radiotherapy. This study was to investigate the colonogen number and its association with the tumor control probability (TCP) in oropharyngeal squamous cell carcinoma (OSCCA). Methods: A literature search was conducted to collect clinical information of patients with OSCCA, including the prescription dose, tumor volume and survival rate. The linear-quadratic (LQ) model was incorporated into TCP model for clinical data analysis. The total dose ranged from 60 to 70 Gy and tumor volume ranged from 10 to 50 cc. The TCP was calculated for each group according to tumor size and dose. The least χ{sup 2} method was used to fit the TCP calculation to clinical data while other LQ model parameters (α, β) were adopted from the literature, due to the limited patient data. Results: A total of 190 patients with T2–T4 OSCCA were included. The association with HPV was not available for all the patients. The 3-year survival rate was about 82% for T2 squamous cell carcinoma and 40% for advanced tumors. Fitting the TCP model to the survival data, the average clonogen number was 1.56×10{sup 12}. For the prescription dose of 70 Gy, the calculated TCP ranged from 40% to 90% when the tumor volume varied from 10 to 50 cc. Conclusion: Our data suggests variation between the clonogen number and TCP in OSCCA. Tumors with larger colonogen number tend to have lower TCP and therefore dose escalation above 70 Gy may be indicated in order to improve the TCP and survival rate. Our result will require future confirmation with a large number of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-209-06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries

Purpose: To develop advanced dynamic collimator positioning algorithms for optimal beam’s-eye-view (BEV) fitting of targets in VMAT procedures, including multiple metastases stereotactic radiosurgery procedures. Methods: A trajectory algorithm was developed, which can dynamically modify the angle of the collimator as a function of VMAT control point to provide optimized collimation of target volume(s). Central to this algorithm is a concept denoted “whitespace”, defined as area within the jaw-defined BEV field, outside of the PTV, and not shielded by the MLC when fit to the PTV. Calculating whitespace at all collimator angles and every control point, a two-dimensional topographical map depicting the tightness-of-fit of the MLC was generated. A variety of novel searching algorithms identified a number of candidate trajectories of continuous collimator motion. Ranking these candidate trajectories according to their accrued whitespace value produced an optimal solution for navigation of this map. Results: All trajectories were normalized to minimum possible (i.e. calculated without consideration of collimator motion constraints) accrued whitespace. On an acoustic neuroma case, a random walk algorithm generated a trajectory with 151% whitespace; random walk including a mandatory anchor point improved this to 148%; gradient search produced a trajectory with 137%; and bi-directional gradient search generated a trajectory with 130% whitespace. For comparison, a fixed collimator angle of 30° and 330° accumulated 272% and 228% of whitespace, respectively. The algorithm was tested on a clinical case with two metastases (single isocentre) and identified collimator angles that allow for simultaneous irradiation of the PTVs while minimizing normal tissue irradiation. Conclusion: Dynamic collimator trajectories have the potential to improve VMAT deliveries through increased efficiency and reduced normal tissue dose, especially in treatment of multiple cranial metastases, without significant safety concerns that hinder immediate clinical implementation.

60 APPLIED LIFE SCIENCES↗

Low current plasmatron fuel converter having enlarged volume discharges

A novel apparatus and method is disclosed for a plasmatron fuel converter ("plasmatron") that efficiently uses electrical energy to produce hydrogen rich gas. The volume and shape of the plasma discharge is controlled by a fluid flow established in a plasma discharge volume. A plasmatron according to this invention produces a substantially large effective plasma discharge volume allowing for substantially greater volumetric efficiency in the initiation of chemical reactions within a volume of bulk fluid reactant flowing through the plasmatron.

30 DIRECT ENERGY CONVERSION↗

Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

System and method for microwave volumetric additive manufacturing

The present disclosure relates to a volumetric additive manufacturing system for forming a structure from a volume of resin using microwave energy. The system makes use of an electronic controller and at least one beam forming algorithm accessible by the electronic controller for generating information relating to an amplitude and a time delay for forming a microwave signal, where the microwave signal will be used in irradiating a build volume, and where the build volume is formed by the volume of resin. A microwave signal generating subsystem is included which is responsive to the information generated by the beam forming algorithm, and which generates a microwave signal using the amplitude and the time delay determined by the beam forming algorithm. An antenna is used to receive the microwave signal and project the microwave signal as a microwave beam, in accordance with the amplitude and time delay, into the build volume to form the structure.

Mukherjee, Saptarshi↗

Reaction‐induced morphology control in block copolymers

Abstract Controlling the self‐assembly behaviors of block copolymers (BCPs) is a focal point of many research thrusts due to their broad use in various applications. While BCP molecular weight, volume fraction, and chemical identities are key thermodynamic parameters to determine their morphology, an emergent method in this area is through reaction‐induced changes to the characteristics of a BCP in situ , which provides access to multiple morphologies and domain sizes from a single parent polymer, as well as enabling the formation of metastable morphologies which may be difficult to attain otherwise. This work provides a focused review about the current state of reaction‐induced morphology control in BCPs in both solution and solid states. Furthermore, we provide a forward‐looking perspective on the future opportunities of understanding and employing reaction engineering to manipulate and advance BCP self‐assembly. © 2023 Society of Industrial Chemistry.

Robertson, Mark↗

Pseudospectral convex optimization for on-ramp merging control of connected vehicles

It can be a daunting task for human drivers to merge into highways because of the intricate vehicle negotiations and potential risk within limited time and space. Connected vehicle (CV) technologies could be a solution to this problem and offer many benefits to the road safety, traffic mobility, and energy efficiency. However, real-time optimal control of CVs is still an open challenge, due to the nonlinear vehicle dynamics, non-convex fuel consumption model, and highly dynamic uncertain inter-vehicle interactions. To tackle these issues, a novel real-time optimal control approach that balances the computational efficiency and solution optimality is proposed for the purpose of onboard application. To this end, the pseudospectral collocation method is integrated with a sequential convex programming approach to develop two new optimization algorithms, which are implemented within a model predictive control (MPC) framework to allow for real-time generation of optimal merging speed profiles. One algorithm leverages the line search technique to improve convergence, and the other benefits from the trust region method for better computational efficiency. The optimality and convergence process of both proposed algorithms are investigated by comparing their solutions with a popular non-linear solver. Furthermore, simulation results show that the proposed methods outperform the benchmark in terms of computational cost, fuel consumption, and traffic efficiency. In particular, the proposed fuel-economy merging rule can save 57.1% fuel consumption on average on four different traffic volumes. Meanwhile, the proposed optimal control algorithms can reduce 2.2% travel time on average comparing to the “first-in-first-out” merging rule.

33 ADVANCED PROPULSION SYSTEMS↗

Biologically Effective Dose (BED) Correlation With Biochemical Control After Low-Dose Rate Prostate Brachytherapy for Clinically Low-Risk Prostate Cancer

Purpose: To assess the correlation of postimplant dosimetric quantifiers with biochemical control of prostate cancer after low-dose rate brachytherapy. Methods and Materials: The biologically effective dose (BED), dose in Gray (Gy) to 90% of prostate (D{sub 90}), and percent volume of the prostate receiving 100% of the prescription dose (V{sub 100}) were calculated from the postimplant dose-volume histogram for 140 patients undergoing low-dose rate prostate brachytherapy from 1997 to 2003 at Durham Regional Hospital and the Durham VA Medical Center (Durham, NC). Results: The median follow-up was 50 months. There was a 7% biochemical failure rate (10 of 140), and 91% of patients (127 of 140) were alive at last clinical follow-up. The median BED was 148 Gy (range, 46-218 Gy). The median D{sub 90} was 139 Gy (range, 45-203 Gy). The median V{sub 100} was 85% (range, 44-100%). The overall 5-year biochemical relapse-free survival (bRFS) rate was 90.1%. On univariate Cox proportional hazards modeling, no pretreatment characteristic (Gleason score sum, age, baseline prostate-specific antigen, or clinical stage) was predictive of bRFS. The BED, D{sub 90}, and V{sub 100} were all highly correlated (Pearson coefficients >92%), and all were strongly correlated with bRFS. Using the Youden method, we identified the following cut points for predicting freedom from biochemical failure: D{sub 90} >= 110 Gy, V{sub 100} >= 74%, and BED >= 115 Gy. None of the covariates significantly predicted overall survival. Conclusions: We observed significant correlation between BED, D{sub 90}, and V{sub 100} with bRFS. The BED is at least as predictive of bRFS as D{sub 90} or V{sub 100}. Dosimetric quantifiers that account for heterogeneity in tumor location and dose distribution, tumor repopulation, and survival probability of tumor clonogens should be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗