Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller area network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

NSTAR Smart Grid Pilot

NSTAR Electric & Gas Corporation (“the Company”, or “NSTAR”) developed and implemented a Smart Grid pilot program beginning in 2010 to demonstrate the viability of leveraging existing automated meter reading (“AMR”) deployments to provide much of the Smart Grid functionality of advanced metering infrastructure (“AMI”), but without the large capital investment that AMI rollouts typically entail. In particular, a central objective of the Smart Energy Pilot was to enable residential dynamic pricing (time-of-use “TOU” and critical peak rates and rebates) and two-way direct load control (“DLC”) by continually capturing AMR meter data transmissions and communicating through customer-sited broadband connections in conjunction with a standards-based home area network (“HAN”). The pilot was supported by the U.S. Department of Energy’s (“DOE”) through the Smart Grid Demonstration program. NSTAR was very pleased to not only receive the funding support from DOE, but the guidance and support of the DOE throughout the pilot. NSTAR is also pleased to report to the DOE that it was able to execute and deliver a successful pilot on time and on budget. NSTAR looks for future opportunities to work with the DOE and others in future smart grid projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Invite the Chaos Monkey: Test Effect Payloads for Tuning ICS Incident Response

In 2010, when Netflix moved their operational systems to the cloud, they developed a pseudo-random mechanism to cause deliberate outages and failures of key system elements to ensure that automated systems for detecting and remediating outages were mature and fully functional. This Chaos Monkey spawned an entire Simian Army designed to ensure system resilience and enable failure response before issues became outages. Through the DARPA RADICS program, Provatech, INL, and other researchers have developed a mechanism for creating controllable failures via Test Effect Payloads (TEPs) for Industrial Control Systems in order to enable an asset owner to tune network and process sensor technology, increase the effectiveness of incident response and remediation, and highlight areas where resilient technology could bring benefit to Operational Technology. This talk will explore what a TEP is, how to create a TEP, and suggest what a systematic system resilience plan using TEP’s might look like. We will also discuss how regulated entities might employ TEP’s in a compliant resilience strategy.

42 ENGINEERING↗

Continuous Monitoring and On-line Analysis of Operational Dose Rates: Tools to Further Mitigate Radiation Risks

Along with passive and active engineering and administrative controls usually implemented in radiation protection programs at different facilities, continuous monitoring and on-line analysis of data measured by the radiation detectors at the workplace and in the environment can be considered as an additional tool used to further mitigate radiation risks. Many monitoring systems on the market today allow connecting radiation area monitors into a network, and reading and accumulating data continuously in a database. The point of this presentation is to bring attention to the fact that such accumulated information can be analyzed and used in many respects to improve reliability and functionality of the monitoring and control systems. A simple time history of background readings from a radiation detector can be used to evaluate the stability of the detector performance. Data recorded during normal facility operations may serve to establish a pattern of acceptable dose rates in such detector and allow to better detect off-normal and unstable modes of the facility operation before they reach hardware trip levels. Facility operators and users may utilize such monitoring systems to optimize operations and minimize their radiological impact. Implementation and examples of use of the RADMON radiation monitoring and data analysis system at Jefferson Lab is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3-D Geologic Controls of Hydrothermal Fluid Flow at Brady geothermal field, Nevada, USA

In many hydrothermal systems, fracture permeability along faults provides pathways for groundwater to transport heat from depth. Faulting generates a range of deformation styles that cross-cut heterogeneous geology, resulting in complex patterns of permeability, porosity, and hydraulic conductivity. Vertical connectivity (a throughgoing network of permeable areas that allows advection of heat from depth to the shallow subsurface) is rare and is confined to relatively small volumes that have highly variable spatial distribution. This local compartmentalization of connectivity represents a significant challenge to understanding hydrothermal circulation and for exploring, developing, and managing hydrothermal resources. Here, we present an evaluation of the geologic characteristics that control this compartmentalization in hydrothermal systems through 3-D analysis of the Brady geothermal field in western Nevada. A published 3-D geologic map of the Brady area is used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity. The 3-D distribution of these variables is compared to the distribution of productive and non-productive fluid flow intervals along production wells and non-productive wells via principal component analysis (PCA). This comparison elucidates which geologic and structural variables are most closely associated with productive fluid flow intervals. Results indicate that production intervals at Brady are located: (1) within or near to known and stress-loaded macro-scale faults, and (2) in areas of high fault and fracture density.

58 GEOSCIENCES↗

Adaptive QoS for Data Transfers using Software-Defined Networking

Software-defined networking (SDN) has demonstrated tremendous potential for altering the networking landscape in both academia andindustry. While traffic engineering as network intelligence in classic technologies have received considerable attention from the researchcommunity, traffic engineering in the SDN space, particularly in regards to quality of service (QoS), remains relatively unexplored.While recent efforts have begun to show how SDN might be leverage to meet the complex traffic-shaping needs of modern networks, there is still much that can be done to illustrate its potential, and in particular how it could prevent degradation of service for all QoStraffic. We propose methods to allow other flows to use bandwidth unused by high-priority transfers, while ensuring that bandwidthassigned to those high-priority transfers is available when needed. We present fine-tuned control over bandwidth allocation that achieves an efficient combination of both the differentiated service (DiffServ)-style classification and the integrated service (IntServ)-style perflowconsiderations. We also show how this method may be used over a wide area network (WAN) to optimally adjust bandwidth allocations when high-priority data transfers are not using their allocated bandwidth.

Boley, Josh↗

3-D Geologic Controls of Hydrothermal Fluid Flow at Brady Geothermal Field, Nevada using PCA

In many hydrothermal systems, fracture permeability along faults provides pathways for groundwater to transport heat from depth. Faulting generates a range of deformation styles that cross-cut heterogeneous geology, resulting in complex patterns of permeability, porosity, and hydraulic conductivity. Vertical connectivity (a through going network of permeable areas that allows advection of heat from depth to the shallow subsurface) is rare and is confined to relatively small volumes that have highly variable spatial distribution. This local compartmentalization of connectivity represents a significant challenge to understanding hydrothermal circulation and for exploring, developing, and managing hydrothermal resources. Here, we present an evaluation of the geologic characteristics that control this compartmentalization in hydrothermal systems through 3-D analysis of the Brady geothermal field in western Nevada. A published 3-D geologic map of the Brady area is used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity. The 3-D distribution of these variables is compared to the distribution of productive and non-productive fluid flow intervals along production wells and non-productive wells via principal component analysis (PCA). This comparison elucidates which geologic and structural variables are most closely associated with productive fluid flow intervals. Results indicate that production intervals at Brady are located: (1) within or near to known and stress-loaded macro-scale faults, and (2) in areas of high fault and fracture density. This submission includes the published journal article detailing this work, the published 3-D geologic map of the Brady Geothermal Area used as a basis to develop structural and geological variables that are hypothesized to control or effect permeability or connectivity, 3-D well data, along which geologic data were sampled for PCA analyses, and associated metadata file. This work was done using existing R programs.

15 GEOTHERMAL ENERGY↗

A robust approach to chance constrained optimal power flow with renewable generation

Optimal Power Flow (OPF) dispatches controllable generation at minimum cost subject to operational constraints on generation and transmission assets. The uncertainty and variability of intermittent renewable generation is challenging current deterministic OPF approaches. Recent formulations of OPF use chance constraints to limit the risk from renewable generation uncertainty, however, these new approaches typically assume the probability distributions which characterize the uncertainty and variability are known exactly. We formulate a robust chance constrained (RCC) OPF that accounts for uncertainty in the parameters of these probability distributions by allowing them to be within an uncertainty set. The RCC OPF is solved using a cutting-plane algorithm that scales to large power systems. We demonstrate the RRC OPF on a modified model of the Bonneville Power Administration network, which includes 2209 buses and 176 controllable generators. In conclusion, deterministic, chance constrained (CC), and RCC OPF formulations are compared using several metrics including cost of generation, area control error, ramping of controllable generators, and occurrence of transmission line overloads as well as the respective computational performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mesh-shape-and-size controlled rapid-melting growth for the formation of single-crystalline (100), (110), and (111) Ge networks on insulators

Single-crystalline-Ge (c-Ge) networks with various crystal orientations on insulators formed on Si substrates are essential for integrating high-speed and multifunctional devices onto the Si platform. c-Ge networks are realized by rapid-melting growth of mesh-patterned amorphous-Ge over large areas (500x250 {mu}m{sup 2}) on (110) and (111) as well as (100) Si substrates by optimizing the shape and the size of the mesh. It is revealed that latent-heat generated at the growth front can be controlled by selecting mesh-shape-and-size, which suppresses the spontaneous nucleation. In addition, essential role of the growth-direction on preventing the rotational growth is clarified.

36 MATERIALS SCIENCE↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Topological Control of Triply Periodic Minimal Surfaces for Thermal Design and Advanced Manufacturing: A Gyroid Case Study

Recently, there has been a heightened interest in using triply periodic minimal surfaces (TPMSs) in the design of compact process engineering components. The benefits of high surface area per unit volume, modular form, and inherent periodicity provide a holistic self-supporting network and flow-conducive features. Applications of importance include thermal power management, biomimetic scaffolds and structures, and feasibility of advanced manufacturing. This study presents a novel approach to the manipulation of the characteristic Schwarz-G, or gyroid TPMS, for thermal design in the context of advanced manufacturing. The study presents relationships between design parameters and resulting surface area as a target response using the characteristic equation of a gyroid. Through parametric control, the characteristic equation is manipulated to produce a 20-fold increase in achievable area over a baseline design characteristic of 25.4 mm through controlled combinations of design parameters. A second relationship is presented as a function of the maximum area achieved and manipulated design parameters. Through the analysis, the study presents a framework to identify and maximize the achievable area of TPMSs for advanced manufacturing and thermal management applications.

gyroid↗

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Survey of Cybersecurity Governance, Threats, and Countermeasures for the Power Grid

The convergence of Information Technologies and Operational Technology systems in industrial networks presents many challenges related to availability, integrity, and confidentiality. In this paper, we evaluate the various cybersecurity risks in industrial control systems and how they may affect these areas of concern, with a particular focus on energy-sector Operational Technology systems. There are multiple threats and countermeasures that Operational Technology and Information Technology systems share. Since Information Technology cybersecurity is a relatively mature field, this paper emphasizes on threats with particular applicability to Operational Technology and their respective countermeasures. We identify regulations, standards, frameworks and typical system architectures associated with this domain. We review relevant challenges, threats, and countermeasures, as well as critical differences in priorities between Information and Operational Technology cybersecurity efforts and implications. These results are then examined against the recommended National Institute of Standards and Technology framework for gap analysis to provide a complete approach to energy sector cybersecurity. We provide analysis of countermeasure implementation to align with the continuous functions recommended for a sound cybersecurity framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

“Green” Fabrication of High-performance Transparent Conducting Electrodes by Blade Coating and Photonic Curing on PET for Perovskite Solar Cells

This study presents an innovative material processing approach to fabricate transparent conducting electrodes (TCEs) on polyethylene terephthalate (PET) substrates using blade coating and photonic curing. The hybrid TCEs consist of a multiscale Ag network, combining silver metal bus lines and nanowires, overcoated by an indium zinc oxide layer, and then photonically cured. Blade coating ensures film uniformity and thickness control over large areas. Photonic curing, a non-thermal processing method with significantly lower carbon emissions, enhances the conductivity and transparency of the coated layers. Our hybrid TCEs achieve an average transmittance of (81 ± 0.4)% referenced to air ((90 ± 0.4)% referenced to the PET substrate) in the visible range, an average sheet resistance of (11 ± 0.5) Ω sq−1, and an average surface roughness of (4.3 ± 0.4) nm. We benchmark these values against commercial PET/TCE substrates. Mechanical durability tests demonstrate <3% change in resistance after 2000 bending cycles at a 1 in radius. The scalable potential of the hybrid TCE fabrication method is demonstrated by high uniformity and excellent properties in 7 in × 8 in large-area samples and by performing the photonic curing process at 11 m min−1. Furthermore, halide perovskite solar cells fabricated on these hybrid TCEs achieve average and champion power conversion efficiencies of (10.5 ± 1.0) % and 12.2%, respectively, and significantly outperform devices made on commercial PET/TCEs. This work showcases our approach as a viable pathway for high-speed “green” manufacturing of high-performance TCEs on PET substrates for flexible optoelectronic devices.

Bonner, Justin C↗

Exe-Guard Project

The exe-Guard Project is an alliance between Dominion Virginia Power (DVP), Sandia National Laboratories (SNL), Dartmouth University, and Schweitzer Engineering Laboratories (SEL). SEL is primary recipient on this project. The exe-Guard project was selected for award under DE-FOA-0000359 with CFDA number 81.122 to address Topic Area of Interest 4: Hardened platforms and Systems. The exe-Guard project developed an antivirus solution for control system embedded devices to prevent the execution of unauthorized code and maintain settings and configuration integrity. This project created a white list antivirus solution for control systems capable of running on embedded Linux® operating systems. White list antivirus methods allow only credible programs to run through the use of digital signatures and hash functions. Once a system’s secure state is baselined, white list antivirus software denies deviations from that state because of the installation of malicious code as this changes hash results. Black list antivirus software has been effective in traditional IT environments but has negative implications for control systems. Black list antivirus uses pattern matching and behavioral analysis to identify system threats while relying on regular updates to the signature file and recurrent system scanning. Black list antivirus is vulnerable to zero day exploits which have not yet been incorporated into a signature file update. System scans hamper the performance of high availability applications, as revealed in NIST special publication 1058 which summarizes the impact of blacklist antivirus on control systems: Manual or “on-demand” scanning has a major effect on control processes in that they take CPU time needed by the control process (Sometimes close to 100% of CPU time). Minimizing the antivirus software throttle setting will reduce but not eliminate this effect. Signature updates can also take up to 100% of CPU time, but for a much shorter period than a typical manual scanning process. Control systems are vulnerable to performance losses if off-the-shelf blacklist antivirus solutions aren’t implemented with care. This investment in configuration in addition to constant decommissioning to perform manual signature file updates is unprecedented and impractical. Additionally, control systems are often disconnected or islanded from the network making the delivery of signature updates difficult. Exe-Guard project developed a white list antivirus solution that mitigated the above drawbacks and allows control systems to cost-effectively apply malware protection while maintaining high reliability. The application of security patches can also be minimized since white listing maintains constant defense against unauthorized code execution. Security patches can instead be applied in less frequent intervals where system decommissioning can be scheduled and planned for. Since control systems are less dynamic than IT environments, the feasibility of maintaining a secure baselined state is more practical. Because upgrades are performed in infrequent, calculated intervals, it allows a new security baseline to be established before the system is returned to service. Exe-Guard built on the efforts of SNL under the Code Seal project. SNL demonstrated prototype Trust Anchors on the project which are independent monitoring and control devices that can be integrated into untrustworthy components. The exe-Guard team started with the lessons learned under this project then designed commercial solution for white list malware protection. Malware is a real threat, even on islanded or un-networked installations, since operators can unintentionally install infected files, plug in infected mass storage devices, or infect a piece of equipment on the islanded local area network that can then spread to other connected equipment. Protection at the device level is one of the last layers of defense in a security-in-depth defense model before an asset becomes compromised. This project provided non-destructive intrusion, isolation and automated response solution, achieving a goal of the Department of Energy (DOE) Roadmap to Secure Control Systems. It also addressed CIP-007-R4 which requires asset owners to employ malicious software prevention tools on assets within the electronic security perimeter. In addition, the CIP-007-R3 requirement for security patch management is minimized because white listing narrows the impact of vulnerabilities and patch releases. The exe-Guard Project completed all tasks identified in the statement of project objective and identified additional tasks within scope that were performed and completed within the original budget. The cost share was met and all deliverables were successfully completed and submitted on time. Most importantly the technology developed and commercialized under this project has been adopted by the Energy sector and thousands of devices with exe-Guard technology integrated in them have now been deployed and are protecting our power systems today

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural connectivity in schizophrenia and its impact on the dynamics of spontaneous functional networks

The neuropathology of schizophrenia remains unclear. Some insight has come from modern neuroimaging techniques, which offer an unparalleled opportunity to explore in vivo the structure and function of the brain. Using functional magnetic resonance imaging, it has been found that the large-scale resting-state functional connectivity (rsFC) in schizophrenia — measured as the temporal correlations of the blood-oxygen-level-dependent (BOLD) signal — exhibit altered network topology, with lower small-world index. The origin of these rsFC alterations and link with the underlying structural connectivity remain unclear. In this work, we used a computational model of spontaneous large-scale brain activity to explore the role of the structural connectivity in the large-scale dynamics of the brain in health and schizophrenia. The structural connectomes from 15 adolescent patients with early-onset schizophrenia and 15 age- and gender-matched controls were built from diffusion tensor imaging data to detect the white matter tracts between 90 brain areas. Brain areas, simulated using a reduced dynamic mean-field model, receive excitatory input from other areas in proportion to the number of fibre tracts between them. The simulated mean field activity was transformed into BOLD signal, and the properties of the simulated functional networks were analyzed. Our results suggest that the functional alterations observed in schizophrenia are not directly linked to alterations in the structural topology. Instead, subtly randomized and less small-world functional networks appear when the brain operates with lower global coupling, which shifts the dynamics from the optimal healthy regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Hierarchical Multi-Agent Based Anomaly Detection for Wide-Area Protection in Smart Grid

Future smart grid capabilities provide assurance to expand the advanced information and communication technologies to evolve into densely interconnected cyber physical system. Remedial Action Scheme (RAS), widely used for wide-area protection, relies on the interconnected networks and data sharing devices, which are exposed to the multitude of vulnerabilities. This paper presents our proposed approach to developing multi-agent based RAS scheme against the system-aware stealthy cyber-attacks. Specifically, we propose the two-level hierarchical architecture which consists of distributed local RAS controllers (RAScs) as local agents, operating at different zones/ areas, which are constantly monitored by an overseer, the central agent. The local controllers receive local and randomly changing outside zonal measurements and cyclically forwards to the overseer. The overseer identifies the corrupted controller using the anomaly detection algorithm which processes the measurements coming from the local controllers, compute measurement errors using local and outside zonal measurements, perform validation checks, and finally detect anomalies based on the two-step verification. Next, as a proof of concept, we have implemented and validated the proposed methodology in cyber physical environment at Iowa State’s PowerCyber testbed. We have also implemented the coordinated attack vectors which involve corrupting the local controller and later performing stealthy attacks on the system’s generator. We have evaluated its performance during the online testing in terms of detection rate and Iatency. The experimental results show that it is efficient in detecting different classes of attacks, including ramp and pulse attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural Analysis and Electrochemical Properties of Bimetallic Palladium-Platinum Aerogels Prepared by a Two-Step Gelation Process

Multimetallic aerogels have emerged as promising unsupported and high-surface-area metal materials for different applications in heterogeneous catalysis and electrochemistry, which are fabricated using a gelation process characterized by the controlled aggregation of metallic nanoparticles to form a macroscopic network structure in aqueous solution. However, the achievement of the structural homogeneity of the multimetallic aerogels in terms of the diameter of the nanochains and the chemical composition at the nano- and the macro-scale is still a great challenge. In this paper, we investigated two Pd-Pt aerogels prepared by the two-step gelation method. The structural homogeneity and chemical distribution of both metals inside the aerogels were analyzed by using high-resolution (scanning) transmission microscopy, energy-dispersive X-ray spectroscopy, extended X-ray absorption fine structure spectroscopy and cyclic voltammetry. The Pd-Pt aerogels show the presence of Pd/Pt-rich domains inside the long-range framework. It is evident that the initial monometallic features dominate over alloying during the gelation process. Although the same synthetic approach for Pd-Pt aerogels with different atomic ratios was used, we observed that the sizes of these monometallic domains varied strongly between the Pd-rich and Pt-rich aerogels. The presence of such metal clusters influenced the electrochemical robustness of the Pd-Pt aerogels dramatically. Further, electrochemical durability investigations revealed that the aerogels with a high content of Pd are less stable because of the gradual dissolution of the less noble metal particularly inside the Pd-rich domains. A chemical and structural homogeneity might improve the lifetime of the Pd-Pt aerogels under electrochemical conditions. In this work, we provide a better understanding of the structure and chemical distribution of the bimetallic aerogel framework prepared by the two-step gelation process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗