Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Ion-chain sympathetic cooling and gate dynamics

Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions.

Cooling & trapping↗

Temperature Mapping of Air Film-Cooled Thermal Barrier Coated Surfaces Using Phosphor Thermometry

While the effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness for jet engine components are usually studied separately, their contributions to combined cooling effectiveness are interdependent and are not simply additive. Therefore, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. Phosphor thermometry offers several advantages for mapping temperatures of air film cooled surfaces. While infrared thermography has been typically applied to study air film cooling effectiveness, temperature accuracy depends on knowing surface emissivity (which may change) and correcting for effects of reflected radiation. Because decay time-based full-field phosphor thermometry is relatively immune to these effects, it can be applied advantageously to temperature mapping of air film-cooled TBC-coated surfaces. In this presentation, an overview will be given of efforts at NASA Glenn Research Center to perform temperature mapping of air film-cooled TBC-coated surfaces in a burner rig test environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and the strengths and limitations of this method for studying air film cooling effectiveness are discussed.

air film cooling↗

Effects of Ambient Inert Gas Properties on Cool-Flame Combustion of Normal-Alkane Droplets in Microgravity

Cool-flame-supported quasi-steady droplet combustion was first observed during droplet combustion experiments conducted onboard the International Space Station (ISS) in the Combustion Integrated Rack (CIR) with n-alkane fuels. These cool flames, not visible to the naked eye, result from the existence of the negative-temperature-coefficient (NTC) region during the combustion n-alkane fuels when the chemical-kinetic pathways experience a transition from the low-temperature chemistry to the normal, high-temperature-controlled chemistry. In this study, we present results for the cool-flame-supported droplet burning rates and extinction diameters for n-alkane fuels (n-heptane, n-octane, n-decane, and n-dodecane) in inert-diluent-substituted ambient environments. In these ISS experiments, some of the nitrogen in the ambient gas mixture is replaced by an inert gas, namely, carbon dioxide, helium, or xenon. Different diluents were observed to exert remarkably different influences on the cool-flame combustion of fuel droplets. The results show that the cool-flame extinction diameter is drastically increased with helium dilution compared to N2, CO2 or Xe, and Xe dilution leads to longer burning with a smaller extinction diameter. Unlike hot flames, the cool-flame burning rates are controlled by the cool-flame temperature established in the NTC region by the chemical kinetics, rather than by equilibrium thermodynamics, and the thermo-physical properties of the ambient gases, which control the heat feed back to the liquid droplet. The cool-flame extinction is triggered by the instability that occurs at the low-temperature end of the NTC region, below which cool diffusion flames become statically unstable. A quasi-steady theoretical model, presented earlier, which involves a six-step reduced-chemistry mechanism, valid around the lower end of the NTC region, is shown to explain the observed experimental trends qualitatively.

microgravity↗

Directly imaging the cooling flow in the Phoenix cluster

In the centres of many galaxy clusters, the hot (approximately 10 7 kelvin) intracluster medium can become dense enough that it should cool on short timescales. However, the low measured star formation rates in massive central galaxies and the absence of soft X-ray lines from the cooling gas suggest that most of this gas never cools. This is known as the cooling flow problem. The latest observations suggest that black hole jets are maintaining the vast majority of gas at high temperatures. A cooling flow has yet to be fully mapped through all the gas phases in any galaxy cluster. Here we present observations of the Phoenix cluster using the James Webb Space Telescope to map the [Ne vi] λ 7.652-μm emission line, enabling us to probe the gas at 10 5.5 kelvin on large scales. These data show extended [Ne vi] emission that is cospatial with the cooling peak in the intracluster medium, the coolest gas phases and the sites of active star formation. Taken together, these imply a recent episode of rapid cooling, causing a short-lived spike in the cooling rate, which we estimate to be 5,000–23,000 solar masses per year. As a result, these data provide a large-scale map of gas at temperatures between 10 5 kelvin and 10 6 kelvin in a cluster core, and highlight the critical role that black hole feedback has in not only regulating cooling but also promoting it.

79 ASTRONOMY AND ASTROPHYSICS↗

A One-dimensional Heat Transfer Model for a Cooled Airfoil in a Direct-fired Supercritical CO 2 Turbine

A one-dimensional (1-D) heat transfer model was developed to predict the performance of a cooled airfoil for a supercritical carbon dioxide (sCO 2 ) turbine. The model included the effects of film cooling effectiveness, thermal barrier coating thickness, and internal Nusselt number augmentation. Trends for overall cooling effectiveness versus heat load parameter were obtained for over twelve unique thermal management schemes. The study found that adding a thermal barrier coating was the most effective scheme for increasing the airfoil overall cooling effectiveness. Internal cooling technologies have diminishing returns as the heat transfer coefficient augmentation increases past a factor of five, however the sensitivity of overall cooling effectiveness to heat transfer augmentation scales by a factor of 1.3 when a thermal barrier coating is introduced. Film cooling is seen as a long-term research area which will be inevitably explored as direct sCO 2 systems develop a market presence. However, the model indicates that realizable film cooling effectiveness levels yield a smaller improvement in overall cooling effectiveness than a thermal barrier coating.

42 ENGINEERING↗

Importance of combining convection with film cooling

The interaction of film and convection cooling and its effect on wall cooling efficiency is investigated analytically for two cooling schemes for advanced gas turbine applications. The two schemes are full coverage- and counterflow-film cooling. In full coverage film cooling, the cooling air issues from a large number of small discrete holes in the surface. Counterflow film cooling is a film-convection scheme with film injection from a slot geometry. The results indicate that it is beneficial to utilize as much of the cooling air heat sink as possible for convection cooling prior to ejecting it as a film.

Colladay, R. S.↗

Importance of combining convection with film cooling.

The interaction of film and convection cooling and its effect on wall cooling efficiency is investigated analytically for two cooling schemes for advanced gas turbine applications. The two schemes are full coverage- and counterflow-film cooling. In full coverage film cooling, the cooling air issues from a large number of small discrete holes in the surface. Counterflow film cooling is a film-convection scheme with film injection from a slot geometry. The results indicate that it is beneficial to utilize as much of the cooling air heat sink as possible for convection cooling prior to ejecting it as a film.

Colladay, R. S.↗

Curved film cooling admission tube

Effective film cooling to protect a wall surface from a hot fluid which impinges on or flows along the surface is provided. A film of cooling fluid having increased area is provided by changing the direction of a stream of cooling fluid through an angle of from 135 deg. to 165 deg. before injecting it through the wall into the hot flowing gas. The 1, cooling fluid is injected from an orifice through a wall into a hot flowing gas at an angle to form a cooling fluid film. Cooling fluid is supplied to the orifice from a cooling fluid source via a turbulence control passageway having a curved portion between two straight portions. The angle through which the direction of the cooling fluid is turned results in less mixing of the cooling fluid with the hot gas, thereby substantially increasing the length of the film in a downstream direction.

Graham, R. W.↗

Self-regulated cooling flows in elliptical galaxies and in cluster cores - Is exclusively low mass star formation really necessary?

A self-consistent treatment of the heating by supernovae associated with star formation in a spherically symmetric cooling flow in a cluster core or elliptical galaxy is presented. An initial stellar mass function similar to that in the solar neighborhood is adopted. Inferred star-formation rates, within the cooling region - typically the inner 100 kpc around dominant galaxies at the centers of cooling flows in XD clusters - are reduced by about a factor of 2, relative to rates inferred when the heat input from star formation is ignored. Truncated initial mass functions (IMFs) are also considered, in which massive star formation is suppressed in accordance with previous treatments, and colors are predicted for star formation in cooling flows associated with central dominant elliptical galaxies and with isolated elliptical galaxies surrounded by gaseous coronae. The low inferred cooling-flow rates around isolated elliptical galaxies are found to be insensitive to the upper mass cutoff in the IMF, provided that the upper mass cutoff exceeds 2 M solar mass. Comparison with observed colors favors a cutoff in the IMF above 1 M solar mass in at least two well-studied cluster cooling flows, but a normal IMF cannot be excluded definitively. Models for NGC 1275 support a young (less than about 3 Gyr) cooling flow. As for the isolated elliptical galaxies, the spread in colors is consistent with a normal IMF. A definitive test of the IMF arising via star formation in cooling flows requires either UV spectral data or supernova searches in the cooling-flow-centered galaxies.

Silk, J.↗

ISM stripping from cluster galaxies and inhomogeneities in cooling flows

Analyses of the x ray surface brightness profiles of cluster cooling flows suggest that the mass flow rate decreases towards the center of the cluster. It is often suggested that this decrease results from thermal instabilities, in which denser blobs of gas cool rapidly and drop below x ray emitting temperatures. If the seeds for the thermal instabilities are entropy perturbations, these perturbations must enter the flow already in the nonlinear regime. Otherwise, the blobs would take too long to cool. Here, researchers suggest that such nonlinear perturbations might start as blobs of interstellar gas which are stripped out of cluster galaxies. Assuming that most of the gas produced by stellar mass loss in cluster galaxies is stripped from the galaxies, the total rate of such stripping is roughly M sub Interstellar Matter (ISM) approx. 100 solar mass yr(-1). It is interesting that the typical rates of cooling in cluster cooling flows are M sub cool approx. 100 solar mass yr(-1). Thus, it is possible that a substantial portion of the cooling gas originates as blobs of interstellar gas stripped from galaxies. The magnetic fields within and outside of the low entropy perturbations can help to maintain their identities, both by suppressing thermal conduction and through the dynamical effects of magnetic tension. One significant question concerning this scenario is: Why are cooling flows seen only in a fraction of clusters, although one would expect gas stripping to be very common. It may be that the density perturbations only survive and cool efficiently in clusters with a very high intracluster gas density and with the focusing effect of a central dominant galaxy. Inhomogeneities in the intracluster medium caused by the stripping of interstellar gas from galaxies can have a number of other effects on clusters. For example, these density fluctuations may disrupt the propagation of radio jets through the intracluster gas, and this may be one mechanism for producing Wide-Angle-Tail radio galaxies.

Soker, Noam↗

Comparison of effectiveness of convection-, transpiration-, and film-cooling methods with air as coolant

Various parts of aircraft propulsion engines that are in contact with hot gases often require cooling. Transpiration and film cooling, new methods that supposedly utilize cooling air more effectively than conventional convection cooling, have already been proposed. This report presents material necessary for a comparison of the cooling requirements of these three methods. Correlations that are regarded by the authors as the most reliable today are employed in evaluating each of the cooling processes. Calculations for the special case in which the gas velocity is constant along the cooled wall (flat plate) are presented. The calculations reveal that a comparison of the three cooling processes can be made on quite a general basis. The superiority of transpiration cooling is clearly shown for both laminar and turbulent flow. This superiority is reduced when the effects of radiation are included; for gas-turbine blades, however, there is evidence indicating that radiation may be neglected.

Eckert, E R G↗

Cooling of solar flares plasmas. 1: Theoretical considerations

Theoretical models of the cooling of flare plasma are reexamined. By assuming that the cooling occurs in two separate phase where conduction and radiation, respectively, dominate, a simple analytic formula for the cooling time of a flare plasma is derived. Unlike earlier order-of-magnitude scalings, this result accounts for the effect of the evolution of the loop plasma parameters on the cooling time. When the conductive cooling leads to an 'evaporation' of chromospheric material, the cooling time scales L(exp 5/6)/p(exp 1/6), where the coronal phase (defined as the time maximum temperature). When the conductive cooling is static, the cooling time scales as L(exp 3/4)n(exp 1/4). In deriving these results, use was made of an important scaling law (T proportional to n(exp 2)) during the radiative cooling phase that was forst noted in one-dimensional hydrodynamic numerical simulations (Serio et al. 1991; Jakimiec et al. 1992). Our own simulations show that this result is restricted to approximately the radiative loss function of Rosner, Tucker, & Vaiana (1978). for different radiative loss functions, other scaling result, with T and n scaling almost linearly when the radiative loss falls off as T(exp -2). It is shown that these scaling laws are part of a class of analytic solutions developed by Antiocos (1980).

Cargill, Peter J.↗

The Stability of Radiatively Cooling Jets I. Linear Analysis

The results of a spatial stability analysis of a two-dimensional slab jet, in which optically thin radiative cooling is dynamically important, are presented. We study both magnetized and unmagnetized jets at external Mach numbers of 5 and 20. We model the cooling rate by using two different cooling curves: one appropriate to interstellar gas, and the other to photoionized gas of reduced metallicity. Thus, our results will be applicable to both protostellar (Herbig-Haro) jets and optical jets from active galactic nuclei. We present analytical solutions to the dispersion relations in useful limits and solve the dispersion relations numerically over a broad range of perturbation frequencies. We find that the growth rates and wavelengths of the unstable Kelvin-Helmholtz (K-H) modes are significantly different from the adiabatic limit, and that the form of the cooling function strongly affects the results. In particular, if the cooling curve is a steep function of temperature in the neighborhood of the equilibrium state, then the growth of K-H modes is reduced relative to the adiabatic jet. On the other hand, if the cooling curve is a shallow function of temperature, then the growth of K-H modes can be enhanced relative to the adiabatic jet by the increase in cooling relative to heating in overdense regions. Inclusion of a dynamically important magnetic field does not strongly modify the important differences between an adiabatic jet and a cooling jet, provided the jet is highly supermagnetosonic and not magnetic pressure-dominated. In the latter case, the unstable modes behave more like the transmagnetosonic magnetic pressure-dominated adiabatic limit. We also plot fluid displacement surfaces associated with the various waves in a cooling jet in order to predict the structures that might arise in the nonlinear regime. This analysis predicts that low-frequency surface waves and the lowest order body modes will be the most effective at producing observable features in the jet.

Hardee, Philip E.↗

On the Lower Limit of Chondrule Cooling Rates: The Significance of Iron Loss in Dynamic Crystallization Experiments

It is unlikely that the presence of chondrules, and thus their formation, within the protoplanetary nebula would be predicted if it were not for their ubiquitous presence in most chondritic meteorites. The study of these enigmatic, igneous objects has a direct influence on how meteoritic and solar system researchers model the processes operating and the materials present within our protoplanetary nebula. Key to understanding chondrule formation is a determination of constraints on their thermal histories. The three important variables in this history are their peak melting temperatures, the duration of their melting at peak temperatures, and the rate at which these object cool. Although these three variables are interdependent, it is cooling rate that provides the most powerful constraint. Cooling rate has a direct affect on the development of both crystal morphology and the elemental distributions within these grains. To date, experiments have indicated that chondrule cooling rates are in the range of 10's to 100's of degrees per hour for porphyritic chondrules (the most abundant type). The cooling rate for radial and barred chondrules is thought to be more rapid. To generate these cooling rates (rapid relative to the cooling of the nebula as a whole, but slow compared to simple black body radiation) the environment of chondrule formation must have been localized, and the abundance of solid materials must have been greatly enhanced above a gas of solar composition. Thus accurate determinations of chondrule cooling rates is critical in understanding both their formation and the nebular environment in which they formed. In a quest to more accurately determine the lower limit on cooling rates and to determine in more detail the effects of Fe loss from a molten sample to Pt wire loops, Weinbruch et al. have explored this issue experimentally and reevaluated the findings of Radomsky and Hewins in light of their new results. The basic conclusions of their paper are an important contribution to our understanding of how experimental techniques can affect established constraints on chondrule formation and are thus of interest to a wide audience. We do believe, however, that their methodology produces results that provide inappropriate impressions of the applicability of their study to chondrule formation and nebular processes. Furthermore, the extensive body of previous experimental work on chondrule bulk compositions cannot be invalidated, as they suggest, by the results of Weinbruch et al. It is for these reasons that within this comment we address to applicability of the results presented by Weinbruch et al. to previous studies, and illustrate how the experimental conditions chosen for their series of experiments introduced a significant bias in their results.

Paque, Julie M.↗

Physiologic Responses Produced by Active and Passive Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

Ku, Yu-Tsuan E.↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

Convective Array Cooling for a Solar Powered Aircraft

A general characteristic of photovoltaics is that they increase in efficiency as their operating temperature decreases. Based on this principal, the ability to increase a solar aircraft's performance by cooling the solar cells was examined. The solar cells were cooled by channeling some air underneath the cells and providing a convective cooling path to the back side of the array. A full energy balance and flow analysis of the air within the cooling passage was performed. The analysis was first performed on a preliminary level to estimate the benefits of the cooling passage. This analysis established a clear benefit to the cooling passage. Based on these results a more detailed analysis was performed. From this cell temperatures were calculated and array output power throughout a day period were determined with and without the cooling passage. The results showed that if the flow through the cooling passage remained laminar then the benefit in increased output power more than offset the drag induced by the cooling passage.

Colozza, Anthony J.↗