Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cosmic Reionization on Computers: Baryonic Effects on Halo Concentrations during the Epoch of Reionization

Baryons both increase halo concentration through adiabatic contraction and expel mass through feedback processes. However, it is not well understood how the radiation fields prevalent during the epoch of reionization affect the evolution of concentration in dark matter halos. We investigate how baryonic physics during the epoch of reionization modify the structure of dark matter halos in the Cosmic Reionization On Computers (CROC) simulations. We use two different measures of halo concentration to quantify the effects. We compare concentrations of halos matched between full-physics simulations and dark-matter-only simulations with identical initial conditions between 5 ≤ z ≤ 9. Baryons in full-physics simulations do pull matter toward the center, increasing the maximum circular velocity compared to dark-matter-only simulations. However, their overall effects are much less than if all the baryons were simply centrally concentrated indicating that heating processes efficiently counteract cooling effects. Finally, we show that the baryonic effects on halo concentrations at z ≈ 5 are relatively insensitive to environmental variations of reionization history. These results are pertinent to models of galaxy–halo connection during the epoch of reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Construction of Cryogen-Free 4.3T Superconducting Wiggler for NSLS-II Ring

With the 3 GeV electron beam energy for the National Synchrotron Light Source II (NSLS-II) ring, only superconducting wigglers (SCW) producing greater than 4T peak field can cover the photon energy range of 20 keV and 200 keV with sufficient number of photons. The High energy Engineering X-ray (HEX) Diffraction beamline, which is primarily funded by the New York State Energy Research and Development Authority (NYSERDA) and NSLS-II, will be equipped with a 1.2m-long SCW with 70 mm period length and 4.3 T on-axis field. This SCW is free from the use of liquid Helium and is cooled only with cryo-coolers. The Electron Beam Chamber (EBC) with vertical aperture of 8 mm is made from 316LN stainless steel and copper plating is applied both surface and +-12.5mm wide from the center in the inner surface. The expected heat load from the electron beam of the NSLS-II ring is estimated to be 10 W/m. Here, we describe the design principles and engineering challenges for the device.

36 MATERIALS SCIENCE↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

XRISM Forecast for the Coma Cluster: Stormy, with a Steep Power Spectrum

The XRISM Resolve microcalorimeter array measured the velocities of hot intracluster gas at two positions in the Coma galaxy cluster: ${3}^{{\prime} }\times {3}^{{\prime} }$ squares at the center and at 6$^{\prime} $ (170 kpc) to the south. We find the line-of-sight velocity dispersions in those regions to be σ z = 208 ± 12 km s −1 and 202 ± 24 km s −1 , respectively. The central value corresponds to a 3D Mach number of M = 0.24 ± 0.015 and a ratio of the kinetic pressure of small-scale motions to thermal pressure in the intracluster plasma of only 3.1% ± 0.4%, at the lower end of predictions from cosmological simulations for merging clusters like Coma, and similar to that observed in the cool core of the relaxed cluster A2029. Meanwhile, the gas in both regions exhibits high line-of-sight velocity differences from the mean velocity of the cluster galaxies, Δv z = 450 ± 15 km s −1 and 730 ± 30 km s −1 , respectively. A small contribution from an additional gas velocity component, consistent with the cluster optical mean, is detected along a sight line near the cluster center. The combination of the observed velocity dispersions and bulk velocities is not described by a Kolmogorov velocity power spectrum of steady-state turbulence; instead, the data imply a much steeper effective slope (i.e., relatively more power at larger linear scales). This may indicate either a very large dissipation scale, resulting in the suppression of small-scale motions, or a transient dynamic state of the cluster, where large-scale gas flows generated by an ongoing merger have not yet cascaded down to small scales.

coma cluster↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Surface Temperature Effect on Convective Heat Transfer Coefficients for Jet Impingement Cooling of Electric Machines with Automatic Transmission Fluid: Preprint

In this study, the results of NREL's continued work on experimental characterization of the thermal performance of free-surface jets of automatic transmission fluid impinged on a heated target surface are presented. The measured heat transfer coefficients are useful for understanding factors influencing performance of driveline fluid-based cooling systems for electric machines and help designers in developing high-performance, power-dense and reliable machines. Experiments were carried out for different fluid and target surface temperatures (50 degrees C, 70 degrees C, and 90 degrees C for the fluid and 90 degrees C, 100 degrees C, 110 degrees C, and 120 degrees C for the target surface). Impinging jet velocities (0.5 m/s to 7.5 m/s) and the jet position on the target surface (center versus edge) were also varied. The impinging angle was kept at 90 degrees relative to the target surface. It was found that higher target surface temperature increased heat transfer coefficients, namely, increasing surface temperature from 90 degrees C to 120 degrees C enhanced heat transfer coefficient values at higher impinged jet velocities (7.5 m/s) by up to 15%.

33 ADVANCED PROPULSION SYSTEMS↗

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Temperature Geothermal Play Fairway Analysis for the Denver Basin: Preprint

This project is part of a national initiative to showcase the benefits of incorporating low-temperature geothermal resource assessment into the deployment of geothermal heating and cooling (GHC), combined heat and power (CHP), and geothermal direct use (GDU) technologies. The initiative was established to accelerate the country's decarbonization efforts by identifying potential for low-temperature geothermal resource utilization (< 150 Degrees Celsius, i.e., GHC, CHP, and GDU) in selected sedimentary basins with numerous population centers. The Play Fairway Analysis (PFA) methodologies in this study were adapted from previous PFA investigations of sedimentary basin geothermal play types (SBGPTs) that evaluated the potential for low-temperature resources (< 150 Degrees Celsius). Workflows, relevant datasets, python code, common and composite geological criteria maps are utilized to develop low-temperature geothermal resource favorability maps for the Denver Basin, a sedimentary basin spanning Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. To facilitate future assessment of low-temperature geothermal resources in SBGPTs, this project provides PFA workflows, data, tools, and favorability maps that will ultimately support the utilization of low-temperature geothermal resources in sedimentary basins.

Denver Basin↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Origin of short- and medium-range order in supercooled liquid Ge 3 Sb 2 Te 6 from ab initio molecular dynamics simulations

Phase-change materials such as Ge–Sb–Te compounds have attracted much attention due to their potential value in electrical data storage. In contrast to the amorphous and crystalline phases, supercooled liquids are far from being deeply understood despite their inevitable role in both amorphization and crystallization processes. To this end, we have studied the dynamics properties and structural characteristics of liquid and supercooled liquid Ge 3 Sb 2 Te 6 during the fast cooling process. As the temperature decreases, chemical bonds become more homogeneous, but coordination numbers of Ge, Sb and Te atoms change very little. Meanwhile, the structural order of short-range configuration is obviously enhanced. Further studies suggest that Ge-centered, Sb-centered and Te-centered configurations change to the more ordered defective octahedrons mainly by adjusting the bond-angle relationship and bond length, rather than just by changing the coordination environment. It is the more ordered octahedrons that promote the formation of medium-range order. Our findings provide a deep insight into the origin of local structural order in supercooled liquid Ge 3 Sb 2 Te 6 , which is of great importance for the comprehensive understanding of amorphization and crystallization processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synergistic Pathways for Water Security in Emerging Sectors: Data Centers and Modern Nuclear Facilities

Stand-alone data centers, nuclear-powered data centers, and novel nuclear facilities such as fusion plant and small modular reactors (SMRs) are rapidly expanding, water-intensive sectors that present a significant challenge to the water-for-energy nexus. Their large-scale consumption of water for cooling systems not only reduces downstream water quantity but also degrades quality, demanding an integrated approach by stakeholders to understand and address these impacts through infrastructure planning and development.

42 ENGINEERING↗

West Virginia University Industrial Assessment Center (Final Progress Report)

The Industrial Assessment Center at West Virginia University has been successful in workforce development, and in generation of energy savings for manufacturing facilities during the period 2016 to 2021. Graduate and undergraduate students have benefited from energy assessment experience and most of them have found good positions as energy engineers and analysts in the industrial sector. Several peer reviewed research papers in archival journals as well as conference papers on the topic of energy engineering and assessment have been published. The implemented energy savings for manufacturing facilities have been significant in the areas of lighting, compressed air, process heating, steam, HVAC, chillers and cooling towers, and motors. In addition, water use reduction, smart manufacturing applications to save energy, cyber security evaluation, energy management, productivity improvements and waste reduction opportunities that lead to energy intensity reductions have been explored. The students have obtained an opportunity to interact with energy efficiency and productivity improvement professionals at various conferences and workshops and their research has generated important results. In summary, the West Virginia University Industrial Assessment Center (WVU-IAC) has fulfilled its mission in regard to workforce development, energy efficiency for manufacturing facilities, and laid a strong platform enhancing sustainability through reductions in carbon emissions achieved through energy efficiency and energy management initiatives and reductions in water usage and waste reduction. During the project period (2016-2021) the WVU-IAC has made numerous energy efficiency, water use reduction, waste reduction, and productivity improvement recommendations, a significant number of them having been implemented by the manufacturing facilities. The research adds significant understanding to the area of energy efficiency, water and waste reduction, and productivity improvement. The technical effectiveness and economic feasibility of the methods and techniques investigated and demonstrated through this project have been exemplary, resulting in significant recommended and implemented resource savings and reductions in carbon emissions. The project has been of significant benefit to the public owing to replication of results within the industrial sector, thus reducing operating costs for businesses that result in increase of growth and employment, as well as community benefits in terms of reductions in carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Structural Analysis of Multilayer Tapered Canted-Cosine-Theta Superconducting Magnet for the Interaction Region of Electron Ion Collider

The electron ion collider (EIC) will collide high energy and highly polarized hadron and electron beams with luminosities up to 10 34 cm -2 s -1 . The magnet designs at the interaction region (IR) are challenging due to the close proximity of the hadron and electron beams. A canted cosine theta (CCT) quadrupole magnet was designed due to the space restrictions at the IR. The CCT magnet has a tapered aperture, which allows higher gradients at the interaction point (IP) side of the magnet. The tapered geometry makes the magnet not symmetrical along the axial direction. In conclusion, to validate the design in terms of the mechanical strength and the allowed deformations, a detailed structural mechanical analysis for the tapered CCT quadrupole magnet has been carried out using the finite element method (FEM) considering both the shrinking due to cool down and the electromagnetic force on the conductors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗

STARTR: An Open-Source MARVEL model for the NRIC Virtual Test Bed [Poster]

The National Reactor Innovation Center (NRIC) seeks to improve the understanding of microreactor physics in industry and academia through the development of a Microreactor Applications Research Validation and Evaluation (MARVEL) reactor-based model, published on the Virtual Test Bed (VTB). To achieve this goal, the Sodium-cooled Thermal-spectrum Advanced Research Test Reactor (STARTR) model was built using publicly available MARVEL specifications where possible and approximations where applicable, and was optimized for fast runtimes for researchers to receive rapid simulation feedback. STARTR will fill a gap between stakeholder interest and available models, as the first Sodium-cooled Thermal Reactor (STR) hosted on the VTB with baseline performance sanctioned by INL. This project involved the definition of all materials used in the reactor, geometry and all reactor subcomponents, and assertion of tallies and simulation settings within OpenMC 0.13.3. This poster details a small subset of the overall reactor physics testing: the two-dimensional power peaking factors and the flux energy spectrum, as well as plots of the created geometry. Future work includes code-to-code verification between the OpenMC-based model and a separately designed MCNP 6.2-based model.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Control of Weld Residual Stress in a Thin Steel Plate through Low Transformation Temperature Welding Consumables

Low transformation temperature welding (LTTW) consumables are characterized by a low martensite start temperature and a large fraction of martensite forming in the weld. It can efficiently reduce the tensile residual stress because the volume expansion associated with the martensitic transformation compensates for the thermal contraction during cooling. In this work, a LTTW wire, designated as EH200B, was created for the arc welding of advanced high-strength steel thin plates. In comparison to conventional ER70S-3 wires, this LTTW wire generated an opposite distortion pattern. Neutron diffraction measurements along the center thickness of the welded plates showed the maximum residual stress along the longitudinal direction (LD) in the weld region, and the heat-affected zone (HAZ) immediately adjacent to the weld region was reduced from ~330 MPa to below 240 MPa by using the LTTW wire. A finite element (FE) model was developed to predict the residual stress distributions of the plates welded under these two wires. The simulation results showed reasonable agreement with the volume-average neutron diffraction data. Compressive residual stress in the weld region using the LTTW wire was predicted by the FE method. Electron backscattered diffraction and x-ray diffraction measurements confirmed ~90% martensite was present in the LTTW weld. The fatigue life of DP980 steel lap joint panels using EH200B wire nearly doubled that of ER70S-3 wire. This improvement was attributed to the high strength and low LD residual stress in the weld and HAZ immediately adjacent to the weld.

36 MATERIALS SCIENCE↗

CFD analysis of a solid pin-fueled small modular fluoride salt-cooled reactor

A computational fluid dynamics (CFD) study is performed for the pre-conceptual solid pin-fueled small modular fluoride salt-cooled reactor developed by the Oak Ridge National Laboratory (ORNL). The solid and fluid regions in a 1/12th section of a fuel assembly are modeled. The solid region includes fuel and non-fuel pins, with heat generation in the active region of the fuel pins. Two different power profiles, uniform and center-peaked, are considered. The FLiBe coolant flows from the bottom to the top of the core, parallel to the bank of fuel and non-fuel pins. The k-ω shear-stress transport (SST) model is chosen as the baseline turbulence model. The effects of grid refinement, inlet turbulence specification, and turbulence models on the temperature and pressure drop predictions are studied. Turbulence model sensitivity is investigated by comparing the results from the k-ω SST model with other two-equation models (k-ω baseline or BSL and k-ε realizable) as well as with anisotropic Reynolds stress transport models (linear pressure-strain and stress-BSL). Here the results show that the choice of turbulence model has a significant impact on the pin temperature and bundle pressure drop predictions. The results from the baseline turbulence model show good agreement between the fuel pin temperatures and bundle pressure drop values predicted using a subchannel model previously developed by the authors of the present study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗