Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Utilizing GEOPHIRES-X Beyond Electricity

The GEOPHIRES tool is a techno-economic simulator for evaluating the thermal performance and cost-competitiveness of geothermal plants for electricity, heating, and/or cooling. The tool combines reservoir, wellbore, and surface plant cost and performance models to estimate overall techno-economic metrics such as net present value or levelized cost of electricity, heating, or cooling. We recently upgraded the tool to an object-oriented Python framework, presented in an accompanying paper. As part of the upgrade, we enhanced the capability to simulate the performance of geothermal plants for heating and cooling, which is the topic of this paper. Specifically, we (1) integrated absorption chillers to investigate the performance of utilizing geothermal heat for cooling, (2) integrated a heat pump module to boost the geothermal temperature and thermal output, (3) integrated a district heating module to estimate heating demand for a district based on local weather data, and simulated heat supply with geothermal energy and peaking boilers, and (4) integrated GEOPHIRES as an engine in the dGeo simulator to perform a geospatial analysis of geothermal district heating feasibility across a large region (e.g., a state or the entire United States) utilizing resource and thermal demand maps. This paper presents background information and case studies for several of these heating and cooling end-use options in GEOPHIRES.

absorption chiller↗

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Reanalysis of Water Withdrawal for Irrigation, Electric Power, and Public Supply Sectors in the Conterminous United States, 1950–2016

Accurately measuring water use by the economy is essential for developing reliable models of water resource availability. Indeed, these models rely on retrospective analyses that provide insights into shifting human population demands and adaptions to water shortages. However, accurate, methodologically consistent, empirically authentic, and spatiotemporally comprehensive historical datasets for water withdrawals are scarce. Herein, we present a reanalysis of annual resolution (1950–2016) historical data set on irrigation, electric power, and public supply water withdrawal within the conterminous United States (US) at the county-level, and, for power plants, at the site-level. To estimate electric power water use, we synthesized a historically comprehensive list of generators and historic patterns in generation across fuels, prime movers, and cooling technologies. Irrigation water use estimation required building a crop-demand model that utilized historical information on irrigated acreage for crops and golf courses, stage-specific crop water demand, and climate information. To estimate public water supply use, we developed a random forest model constructed from information on population, infrastructure, climate, and land cover. These estimates generally agree with total county and state water use information provided by the US Geological Survey (USGS) water use circular and estimates generated from independent studies for specific years. However, we also observed discrepancies between our estimates and USGS data that appear to be caused by inconsistencies in the methods used by the USGS's primary data sources at the state level over decades of data collection, highlighting the importance of reanalysis to yield spatiotemporally consistent and intercomparable estimates of water use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗

A Community Energy Operations and Planning System: Concept, Use cases, Metrics, and Benefits

Community and city leaders are interested in achieving sustainability goals, providing resilient energy infrastructure, and improving economic competitiveness. Community-level data acquisition and analysis can provide energy and associated benefits that are not possible at the single building level. However, there is a lack of organizational structure, common semantic data models, interoperable systems, and methods to support data-driven decision-making for community-scale energy supply and demand systems. We explored the need and opportunity for a Community Energy Operations and Planning System (Community EOPS), a potential data exchange platform. We conducted “customer discovery” interviews, and reviewed literature, public tools, and technology platforms to identify key energy data “users” and use cases in communities. The key users of the Community EOPS could be developers of mixed-use districts, corporate, defense and university campus energy managers, and city managers of cities that own their energy utility. The value could be for community planning and reporting (for energy data-integrated land use planning and community infrastructure investments in microgrids, storage, district heating and cooling), energy efficiency (leveraging optimizations for community scale energy supply and demand), flexible load management (grid-edge load management to offset, shift, and flatten loads for multiple buildings and EV fleets), cost savings and revenue generation (participating in grid services), and social benefits such as energy resilience, equity, and awareness. We developed a conceptual Community EOPS architecture with recommendations for streamlined and prioritized data acquisition, sharing, and integration driven by prioritized use cases, common metrics, and actionable visualizations that can provide value to a community’s users.

Singh, Reshma↗

Gradient Amine Sorbents for Low Vacuum Swing CO 2 Capture at Ambient Temperature

The growing concerns over CO 2 emissions have led to the development of various methods for CO 2 capture. CO 2 capture by amine-based sorbents has been achieved by temperature (thermal) swing adsorption (TSA) process, pressure swing adsorption (PSA) process, and temperature pressure or vacuuming swing adsorption (TPSA or TVSA) process for CO 2 capture. Amine sorbents for energy-efficient TSA, PSA, VSA, TPSA or TVSA CO 2 capture should possess a capability which allow adsorbed CO 2 to desorb and amine sorbent to be regenerated at low temperatures or low vacuums. Development of such amine sorbents would significantly decrease energy consumption and sorbent degradation during the regeneration step. The objective of this project is to develop a low vacuum swing adsorption (VSA) process for the capture of CO 2 from air. The focus is on the development of amine sorbent which allows CO 2 to adsorb in the form of weakly adsorbed CO 2 . The weakly adsorbed CO 2 species can be collected from the sorbent by applying a low vacuum at ambient temperature. Specifically, no heating (i.e., thermal energy) is needed for regeneration of amine sorbents. This novel sorbent allows VSA to be operated at ambient temperature without a significant energy demand. This process eliminates the energy-intensive heating and cooling process in temperature swing adsorption (TSA) process. Ambient temperature operation could prolong the lifetime of sorbent and minimize the maintenance cost. Extensive sorbent studies with in-situ infrared spectroscopy have revealed the modifications of conventional amine sorbents with additives can increase the fraction of weakly adsorbed CO 2 . The amine sorbents with loaded CO 2 can be regenerated in part by the following approaches: (i) mild heating to temperatures below 70 °C, (ii) flowing purging gas over modified amine sorbents at temperatures below 40 °C, (iii) vacuuming at pressure below 0.2 atm and temperatures below 40 °C. The performance of these modified amine sorbents has been tested in a 60 grams VSA unit at ambient temperatures. The results show that weakly adsorbed CO 2 which can be desorbed from modified amine sorbents with purging gas at 100 cc/min can also be evacuated at a vacuum of 1 psia at room temperature. A preliminary techno- economic analysis indicates the major cost of the VSA process with modified amine sorbents stems from the operation of vacuum pumps. Thus, developing an excellent sealing with minimum leakage for the VSA unit is the most critical task for further the development of this VSA technology.

36 MATERIALS SCIENCE↗

A 1 MW, 100 kV, less than 100 kg space based dc-dc power converter

A 1 MW dc-dc power converter has been designed which has an input voltage of 5 kV +/-3 percent, an output voltage of 100 kV +/- 0.25 percent, and a run time of 1000 s at full power. The estimated system mass is 83.8 kg, giving a power density of 11.9 kW/kg. The system exceeded the weight goal of 10 kW/kg through the use of innovative components and system concepts. The system volume is approximately 0.1 cu m, and the overall system efficiency is estimated to be 87 percent. Some of the unique system features include a 50-kHz H-bridge inverter using MOS-controlled thyristors as the switching devices, a resonance transformer to step up the voltage, open-cycle cryogenic hydrogen gas cooling, and a nonrigid, inflatable housing which provides on-demand pressurization of the power converter local environment. This system scales very well to higher output powers. The weight of the 10-MW system with the same input and output voltage requirements and overall system configuration is estimated to be 575.3 kg. This gives a power density of 17.4 kW/kg, significantly higher than the 11.9 kW/kg estimated at 1 MW.

Cooper, J. R.↗

Development of Advanced Multizone Facilities for Microgravity Processing

NASA has been interested in experimental ground based study to investigate the fundamental processes involved in phase transformation processes during growth of metallic, nonmetallic and electronic materials. Solidification, vapor growth and solution growth techniques of growing crystals are of special interest because of the inherent importance of convection in the nutrient solution. Convection enhances the mass transport through the nutrient and results in faster growth rates. Availability of low gravity environment of space has provided scientists a new variable to control the extent of convection and thus isolate the diffusive phenomena for their better understanding. The thermal gradient at the liquid-solid interface is determined by the alloy characteristics, the hot zone temperature, cold zone temperature and the width of the insulating zone. The thermal profiles get established by the existing material and geometrical constraints of the experimental set up. The major effort under this research was devoted to designing a programmable furnace which can be used to obtain thermal profiles along the length of the sample as per the demands of the scientists. The furnace did not have active cooling of the zones. Only active heating and passive cooling were utilized.

Source record↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Design and analysis of optimal pre-cooling in residential buildings

Existing pre-cooling strategies provide a means of shifting or reducing the peak demand and/or energy cost in residential buildings. However, majority of them are rule-based and therefore may not be optimal in terms of cost saving, leaving room for improvement. In this paper, an integer linear programming problem that accounts for the thermal properties of a specific home, HVAC system capacity, utility rate structure, and weather conditions and makes use of a home thermal model is formulated. This problem determines the HVAC on/off control signal that minimizes the 24-h energy cost while maintaining thermal comfort and calculates the corresponding optimal indoor air temperature. The model is constructed using home thermal properties identified via data training in real-time. Through simulation, the energy performance of the proposed optimal pre-cooling strategy is investigated and compared with three rule-based operation strategies from the literature. It is found that the optimal strategy requires the least energy consumption without sacrificing thermal comfort. The superb energy performance of the optimal strategy is attributed to a longer runtime of the HVAC system in cool outdoor air conditions and to the elimination of deadband in HVAC operation, which is required by the rule-based strategies, to allow the indoor air temperature to stay near the thermal comfort upper bound as much as possible. In terms of energy cost, the rule-based operation strategies require 3.52, 1.90, and 2.79, respectively, while the optimal strategy only requires 1.52. These figures represent a saving of 56.82%, 20.00%, and 45.52%, respectively. The results suggest that the optimal strategy is indeed significantly more effective than the existing rule-based operation strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Global and regional hydrological impacts of global forest expansion

Abstract. Large-scale reforestation, afforestation, and forest restoration schemes have gained global support as climate change mitigation strategies due to their significant carbon dioxide removal (CDR) potential. However, there has been limited research into the unintended consequences of forestation from a biophysical perspective. In the Community Earth System Model version 2 (CESM2), we apply a global forestation scenario, within a Paris Agreement-compatible warming scenario, to investigate the land surface and hydroclimate response. Compared to a control scenario where land use is fixed to present-day levels, the forestation scenario is up to 2 °C cooler at low latitudes by 2100, driven by a 10 % increase in evaporative cooling in forested areas. However, afforested areas where grassland or shrubland are replaced lead to a doubling of plant water demand in some tropical regions, causing significant decreases in soil moisture (∼ 5 % globally, 5 %–10 % regionally) and water availability (∼ 10 % globally, 10 %–15 % regionally) in regions with increased forest cover. While there are some increases in low cloud and seasonal precipitation over the expanded tropical forests, with enhanced negative cloud radiative forcing, the impacts on large-scale precipitation and atmospheric circulation are limited. This contrasts with the precipitation response to simulated large-scale deforestation found in previous studies. The forestation scenario demonstrates local cooling benefits without major disruption to global hydrodynamics beyond those already projected to result from climate change, in addition to the cooling associated with CDR. However, the water demands of extensive forestation, especially afforestation, have implications for its viability, given the uncertainty in future precipitation changes.

Environmental Sciences & Ecology↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗

Advances in Desiccant Wheels for Dehumidification, VOC Mitigation, and CO 2 Removal for Energy-Efficient IAQ Management

Humidity control is pivotal to maintain occupant thermal comfort and suppress mold growth in indoor environments. Furthermore, poor indoor air quality (IAQ) due to the presence of volatile organic compounds (VOCs) and high concentrations (>1,000 ppm) of CO 2 can cause health issues and negatively affect cognitive performance. Therefore, providing high-quality indoor air has gained significant attention over the past decade. Conventional cooling coil and filter-based HVAC systems have limited capability to meet the augmented demand for occupant thermal comfort and high indoor air quality. Moreover, modern buildings are increasingly airtight to save energy, and increasing ventilation to mitigate VOC and CO 2 concentration is discouraged. Separate sensible and latent cooling technology using a rotary desiccant wheel presents a promising solution in this respect. Because of the development of desiccant materials with high water vapor, VOC, and CO 2 uptake, desiccant wheels can be used as an integrated technology option for IAQ management. Here, to promote desiccant wheel use for energy-efficient management of IAQ in buildings, this article reviews recent advancements in using desiccant wheels for dehumidification, VOC mitigation, and CO 2 capture from outdoor air. Finally, the article presents the authors’ perspective by summarizing the key research gaps in the field and discussing the future direction of research to address these gaps from two different aspects, namely, suitable adsorbent material development and desiccant wheel design.

CO2 capture↗