Undoped Polyaniline/Surfactant Complex for the Corrosion Prevention

Due to the strict regulations on the usage of heavy metals as the additives in the coating industries, the search for effective organic corrosion inhibitors in replace of those metal additives has become essential. Electrically conducting polymers have been shown to be effective for corrosion prevention but the poor solubility of these intractable polymers has been a problem. We have explored a polyaniline/4-dodecylphenol complex (PANi/DDPh) to improve the dissolution and it has been shown to be an effective organic corrosion inhibitor. With the surfactant, DDPh, PANi could be diluted into the coatings and the properties of the coatings were affected. Emeraldine base (EB) form of PANi was also found to be oxidized by the hardener. The oxidized form of polyaniline provides improved corrosion protection of metals than that of emeraldine base since the value of the standard electrode potential for the oxidized form of PANi is higher than that of EB. Additionally, the surfactant improves the wet adhesion property between the coating and the metal surface.

Liu, Lo-Min↗

Corrosion Studies of 2195 Al-Li Alloy and 2219 Al Alloy with Differing Surface Treatments

Corrosion studies of 2195 Al-Li and 2219 Al alloys have been conducted using the scanning reference electrode technique (SRET) and the polarization resistance (PR) technique. The SRET was used to study corrosion mechanisms, while corrosion rate measurements were studied with the PR technique. Plates of Al203 blasted, soda blasted and conversion coated 2219 Al were coated with Deft primer and the corrosion rates studied with the EIS technique. Results from all of these studies are presented.

Danford, M. D.↗

Halogen-Containing Gases as Boundary Lubricants for Corrosion-Resistant Alloys at 1200 F

The extreme temperatures anticipated for lubricated parts in advanced flight powerplants dictate the consideration of unconventional methods of lubrication such as solid lubricants and the reactive gases described in the present research. These halogen-containing "reactive" gases such as dichlorodifluoromethane, CF2Cl2, are among the most stable of organic molecules. The high "flash" temperatures generated at the contacting asperities as a result of frictional heat are sufficient to cause local decomposition of the halogen-containing gases. The active atoms thus released (e.g., chlorine) then react with the metal to be lubricated to form halides capable of effective lubrication. The presence of small amounts of a sulfur-containing gas (e.g., 1 percent sulfur hexafluoride, SF6) was found to catalyze the formation of metal halides. Friction and wear studies were made with a hemisphere (3/16-in. rad.) rider sliding in a circumferential path on the flat surface of a rotating disk (2 1/2-in. diam.). The specimens of corrosion-resistant 2 alloys were run in an atmosphere of the various gases with a load of 1200 grams, a sliding velocity of 120 feet per minute, and temperature from 75 to 1200 F. An effective lubricant for ferritic materials (M-1 tool steel) was CF2Cl2, but significant corrosion occurred above 600 F. Corrosion evaluation in CF2Cl2 suggested a number of nickel- and cobalt-base alloys for additional lubrication study. Several combinations of gases and these metals were found to lubricate to 1200 F without excessive corrosion. The gases were CF2Cl2 Plus 1 percent SF6, monobromotrifluoromethane CF3Br plus 1 percent SF6, dibromodifluoromethane CF2Br2, iodotrifluoromethane, CF3I, and I2. Careful selection of metals and gas are necessary for successful lubrication over specific temperature ranges. Optimum combinations give friction coefficients as low as 0.05 without

Buckley, Donald H.↗

Burner Rig Hot Corrosion of a Single Crystal Ni-48Al-Ti-Hf-Ga Alloy

The hot corrosion resistance of a single crystal Ni-48Al-1Ti-0.5Hf-0.2Ga alloy was examined in a Mach 0.3 burner rig at 900 C for 300 hours. The combustion chamber was doped with 2 ppmw synthetic sea salt. The hot corrosion attack produced a random mound morphology on the surface. Microstructurally, the hot corrosion attack appeared to initiate with oxide-filled pits which were often broad and shallow. At an intermediate stage, the pits increased in size to incorporate unoxidized Ni islands in the corrosion product. The rampant attack stage, which was observed only at sharp sample corners, was characterized by rapid inward growth of alumina in finger-like protrusions incorporating significant amounts of Al-depleted Ni islands. Aluminum consumption in the oxide fingers resulted in the growth of a gamma' layer ahead of the advancing oxide fingers.

Nesbitt, James A.↗

Assessment of Microbiologically Influenced Corrosion Potential in the International Space Station Internal Active Thermal Control System Heat Exchanger Materials: A 6-Momths Study

The fluid in the Internal Active Thermal Control System (IATCS) of the International Space Station (ISS) is water based. The fluid in the ISS Laboratory Module and Node 1 initially contained a mix of water, phosphate (corrosion control), borate (pH buffer), and silver sulfate (Ag2SO4) (microbial control) at a pH of 9.5+/-0.5. Over time, the chemistry of the fluid changed. Fluid changes included a pH drop from 9.5 to 8.3 due to diffusion of carbon dioxide (CO2) through Teflon(reistered Trademark) (DuPont) hoses, increases in dissolved nickel (Ni) levels, deposition of silver (Ag) to metal surfaces, and precipitation of the phosphate (PO4) as nickel phosphate (NiPO4). The drop in pH and unavailability of a antimicrobial has provided an environment conducive to microbial growth. Microbial levels in the fluid have increased from >10 colony-forming units (CFUs)/100 ml to 10(exp 6) CFUs/100 ml. The heat exchangers in the IATCS loops are considered the weakest point in the loop because of the material thickness (=7 mil). It is made of a Ni-based braze filler/CRES 347. Results of a preliminary test performed at Hamilton Sundstrand indicated the possibility of pitting on this material at locations where Ag deposits were found. Later, tests have confirmed that chemical corrosion of the materials is a concern for this system. Accumulation of micro-organisms on surfaces (biofilm) can also result in material degradation and can amplify the damage caused by the chemical corrosion, known as microbiologically influenced corrosion (MIC). This paper will discuss the results of a 6-mo test performed to characterize and quantify the damage from microbial accumulation on the surface of the ISS/ATCS heat exchanger materials. The test was designed to quantify the damage to the materials under worst-case conditions with and without micro-organisms present at pH 8.3 and 9.5.

Roman, Monsi C.↗

Application of Terahertz Radiation to the Detection of Corrosion under the Shuttle's Thermal Protection System

There is currently no method for detecting corrosion under Shuttle tiles except for the expensive process of tile removal and replacement; hence NASA is investigating new NDE methods for detecting hidden corrosion. Time domain terahertz radiation has been applied to corrosion detection under tiles in samples ranging from small lab samples to a Shuttle with positive results. Terahertz imaging methods have been able to detect corrosion at thicknesses of 5 mils or greater under 1" thick Shuttle tiles and 7-12 mils or greater under 2" thick Shuttle tiles.

Madaras, Eric I.↗

Processing and Probability Analysis of Pulsed Terahertz NDE of Corrosion under Shuttle Tile Data

This paper examines data processing and probability analysis of pulsed terahertz NDE scans of corrosion defects under a Shuttle tile. Pulsed terahertz data collected from an aluminum plate with fabricated corrosion defects and covered with a Shuttle tile is presented. The corrosion defects imaged were fabricated by electrochemically etching areas of various diameter and depth in the plate. In this work, the aluminum plate echo signal is located in the terahertz time-of-flight data and a threshold is applied to produce a binary image of sample features. Feature location and area are examined and identified as corrosion through comparison with the known defect layout. The results are tabulated with hit, miss, or false call information for a probability of detection analysis that is used to identify an optimal processing threshold.

Anastasi, Robert F.↗

Selectable-Tip Corrosion-Testing Electrochemical Cell

The figure depicts aspects of an electrochemical cell for pitting- corrosion tests of material specimens. The cell is designed to generate a region of corrosion having a pit diameter determined by the diameter of a selectable tip. The average depth of corrosion is controlled by controlling the total electric charge passing through the cell in a test. The cell is also designed to produce minimal artifacts associated with crevice corrosion. There are three selectable tips, having diameters of 0.1 in. (0.254 cm), 0.3 in. (0.762 cm), and 0.6 in. (1.524 cm), respectively.

Lomness, Janice↗

The Effects of Hot Corrosion Pits on the Fatigue Resistance of a Disk Superalloy

The effects of hot corrosion pits on low cycle fatigue life and failure modes of the disk superalloy ME3 were investigated. Low cycle fatigue specimens were subjected to hot corrosion exposures producing pits, then tested at low and high temperatures. Fatigue lives and failure initiation points were compared to those of specimens without corrosion pits. Several tests were interrupted to estimate the fraction of fatigue life that fatigue cracks initiated at pits. Corrosion pits significantly reduced fatigue life by 60 to 98 percent. Fatigue cracks initiated at a very small fraction of life for high temperature tests, but initiated at higher fractions in tests at low temperature. Critical pit sizes required to promote fatigue cracking were estimated, based on measurements of pits initiating cracks on fracture surfaces.

Gabb, Timothy P.↗

Environmentally Friendly Corrosion Preventative Compounds for Ground Support Structures

The need to use environmentally friendly technologies throughout future space-related launch programs prompted a study aimed at replacing current petroleum and solvent-based Corrosion Preventive Compounds (CPCs) with environmentally friendly alternatives. The work in this paper focused on the identification and evaluation of environmentally friendly CPCs for use in protecting flight hardware and ground support equipment from atmospheric corrosion. CPCs are used as temporary protective coatings and must survive in the aggressive coastal marine environment that exists throughout the Kennedy Space Center, Florida. The different protection behaviors of fifteen different oily film CPCs, both common petroleum-based and newer environmentally friendly types, were evaluated on various steel and aluminum substrates. CPC and substrate systems were subjected to atmospheric testing at the Kennedy Space Center's Beachside Atmospheric Corrosion Test Site, as well as cyclic accelerated corrosion testing. Each CPC also underwent physical characterization and launch-related compatibility testing. The results for the fifteen CPC systems are presented in this paper.

Montgomery Eliza L.↗

Smart Coatings for Launch Site Corrosion Protection

Smart, environmentally friendly paint system for early corrosion detection, mitigation, and healing that will enable supportability in KSC launch facilities and ground systems through their operational life cycles. KSC's Corrosion Technology Laboratory is developing a smart, self-healing coating that can detect and repair corrosion at an early stage. This coating is being developed using microcapsules specifically designed to deliver the contents of their core when corrosion starts.

TechPort Portfolio System↗

Stress Corrosion Cracking of Metals in Propellants

Stress corrosion cracking (SCC) of a fracture critical metallic material can cause a premature failure if the material is susceptible in the unique service environment. Material fluid compatibility is an area of interest for the current NASA programs leading the human exploration path to Mars. White Sands Test Facility, the agency's lead on hypergolic propellant testing, identifies a lack in stress corrosion cracking susceptibility data for metallic materials in hypergolic propellants. The development of a stress corrosion cracking screening method is necessary to bridge the knowledge gap and enable the community to more confidently select materials for the use in systems containing corrosive fluids.

Alcantara, Ilse↗

Pre-Demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives: (1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer). (2) Provide evidence of resistance to aircraft alkaline cleaners and de-icing fluids. (3) Provide formulation for initial ecological and toxicity screening. (4) Submit an interim report that will provide the basis for a future ESTCP (the Dept. of Defense's (DoD's) Environmental Security Technology Certification Program) demonstration effort.The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kilograms. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow-on ESTCP demonstration effort. Test results provided evidence of resistance to alkaline cleaners and aircraft de-icing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization. Abstract for Appendix A. Toxicology Report: Corrosion controls a significant problem for military equipment. Many surface treatment materials currently in use on items of military or aerospace materiel contain chromium (VI) as a component, a source of significant human health and environmental hazard. The formulation under evaluation contains no chromium. Most of the proposed components are low to moderate toxicity and are not a significant concern. Two of the formulation components are associated with some cancer hazard - 2-mercaptobenzothiazole and formaldehyde, but both find widespread use in industry and additional investigation is not required for this project.

Calle, Luz Marina↗

Stress corrosion

This article recounts briefly some of the more critical stress-corrosion failures that have been experienced at Marshall Space Flight Center and the corrective action taken. Some of the recent stress corrosion studies are described and preliminary results tabulated. Specific problems described are the H-1 Engine LOX dome, the pneumatic line fitting sleeve problems and the more recent problem with wave springs used on MF-flared tube fittings. The use of nitric oxide in preventing stress-corrosion failures in titanium tanks is also discussed.

HIGH STRENGTH ALLOY↗

Pre-Demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives: (1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer). (2) Provide evidence of resistance to aircraft alkaline cleaners and deicing fluids. (3) Provide formulation for initial ecological and toxicity screening. (4) Submit an interim report that will provide the basis for a future ESTCP demonstration effort. The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kg. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow on ESTCP demonstration effort. Test results provided evidence of resistance to alkaline cleaners and aircraft deicing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization.

Alternatives to Hexavalent Chromium, Controlled Re↗

Cyclic Oxidation and Hot Corrosion of NiCrY-Coated Disk Superalloy

Powder metallurgy disk superalloys have been designed for higher engine operating temperatures through improvement of their strength and creep resistance. Yet, increasing disk application temperatures to 704 C and higher could enhance oxidation and activate hot corrosion in harmful environments. Protective coatings could be necessary to mitigate such attack. Cylindrical coated specimens of disk superalloys LSHR and ME3 were subjected to thermal cycling to produce cyclic oxidation in air at a maximum temperature of 760 C. The effects of substrate roughness and coating thickness on coating integrity after cyclic oxidation were considered. Selected coated samples that had cyclic oxidation were then subjected to accelerated hot corrosion tests. The effects of this cyclic oxidation on resistance to subsequent hot corrosion attack were examined.

Hot corrosion↗

Corrosion Failure in Electronic Devices for Aerospace Application

Corrosion of complex electronic systems is a growing and expensive concern. New materials and technology are constantly being introduced to increase performance of devices. There are many factors that can induce a corrosive environment during the various stages of manufacturing, processing, transport, and storage of these devices. The scope of this paper was to identify potential causes for the corrosion failure of optocoupler batches being used in launch applications. Optical microscope with surface profile measurements, scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDS), and X-ray photoelectron spectroscopy (XPS) were used to identify and analyze the source of these failure. These studies revealed that the loss of adhesion between the electrolytic plated gold and nickel layers is the critical area that traps impurity ions into the chip allowing for blisters to form along the pins of the optocoupler.

Corrosion↗

Pre-Demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives: (1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer). (2) Provide evidence of resistance to aircraft alkaline cleaners and deicing fluids. (3) Provide formulation for initial ecological and toxicity screening. (4) Submit an interim report that will provide the basis for a future ESTCP demonstration effort. The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kg. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow on ESTCP demonstration effort. Test results provided evidence of resistance to alkaline cleaners and aircraft deicing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization.

Alternatives to Hexavalent Chromium↗