Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic fluid transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Solid-State Thermodynamic Vent System (STVS) for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellant condition. By exploiting the vacuum-induced cryocooling (VIC) potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger (HX) can expel some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. Testing proved the effectiveness of the concept by reducing the liquid nitrogen (LN 2 ) boiloff rate and tank pressure by roughly 70% and 77%, respectively, during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Cryogenic Fluid↗

Cryogenic Fluid Management Technologies for Advanced Green Propulsion Systems

In support of the Exploration Vision for returning to the Moon and beyond, NASA and its partners are developing and testing critical cryogenic fluid propellant technologies that will meet the need for high performance propellants on long-term missions. Reliable knowledge of low-gravity cryogenic fluid management behavior is lacking and yet is critical in the areas of tank thermal and pressure control, fluid acquisition, mass gauging, and fluid transfer. Such knowledge can significantly reduce or even eliminate tank fluid boil-off losses for long term missions, reduce propellant launch mass and required on-orbit margins, and simplify vehicle operations. The Propulsion and Cryogenic Advanced Development (PCAD) Project is performing experimental and analytical evaluation of several areas within Cryogenic Fluid Management (CFM) to enable NASA's Exploration Vision. This paper discusses the status of the PCAD CFM technology focus areas relative to the anticipated CFM requirements to enable execution of the Vision for Space Exploration.

Motil, Susan M.↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Helium

Understanding two-phase cryogenic propellant behavior is key to enabling technologies for future spaceflight missions. Developing accurate models of two-phase flow phenomena, particularly flow boiling in the heating configuration is relevant to the propellant transfer process both in microgravity and on other planetary surfaces. Currently there is a need for more accurate, direct cryogenic data anchored models for various boiling phenomena. Recently, universal correlations for cryogens flowing in heated tubes have been developed for a wide variety of fluids, thermodynamic conditions, and various regimes across the boiling curve, and have been patched to provide a smooth, continuous predictive curve. This paper demonstrates how these correlations have been ported into Thermal Desktop to improve predictive performance. To test the validity of the new correlations, Thermal Desktop is validated against a historical dataset of flow boiling experiments in the heating configuration using liquid helium. Based on results, the new correlations show a substantial improvement over the original built-in flow boiling correlations in Thermal Desktop in predicting the wall temperature as a function of preponderant parameters for this quantum fluid.

cryogenic propellant transfer↗

Modeling Autogenous Pressurization and Draining of a Cryogenic Storage Tank in Normal Gravity

A two-phase CFD model for autogenous pressurization and draining of a cryogenic storage tank is presented using both the Sharp Interface and Volume-Of-Fluid (VOF) approaches for capturing the front and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. Both models are validated against data provided by the Cryogenic Propellant Storage and Transfer (CPST) Engineering Development Unit (EDU) experiment. The results of the autogenous pressurization are presented first, focusing on the phase change and turbulence effects on the tank pressure and temperature predictions. Both the Sharp Interface (SI-CFD) and VOF (VOF-CFD) multiphase models predict tank pressure during pressurization within 3% of the measured values. The sensitivity of key physical and numerical parameters of the problem are tested using the Sharp Interface model. Effects of the accommodation coefficient (AC), and the computational grid structure are studied. The second part of this paper is devoted to validating the SI-VOF model, with an enhanced capability of moving the liquid-vapor interface, against the draining segment of the EDU experiment. The VOF-CFD model was also used to simulate tank draining and its results were compared with the results of the Sharp Interface model with the moving interface. Both models predict tank pressure during draining within 3.5% of the measured values. Pressure decrease rate is underpredicted by both models during the first 100 seconds of draining but matches the experimental rate for the rest of the simulation.

Computational Fluid Dynamics↗

Modeling Autogenous Pressurization and Draining of a Cryogenic Storage Tank in Normal Gravity

A two-phase CFD model for autogenous pressurization and draining of a cryogenic storage tank is presented using both the Sharp Interface and Volume-Of-Fluid (VOF) approaches for capturing the front and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. Both models are validated against data provided by the Cryogenic Propellant Storage and Transfer (CPST) Engineering Development Unit (EDU) experiment1. The results of the autogenous pressurization are presented first, focusing on the phase change and turbulence effects on the tank pressure and temperature predictions. Both the Sharp Interface (SI-CFD) and VOF (VOF-CFD) multiphase models predict tank pressure during pressurization within 3% of the measured values. The sensitivity of key physical and numerical parameters of the problem are tested using the Sharp Interface model. Effects of the accommodation coefficient (AC), and the computational grid structure are studied. The second part of this paper is devoted to validating the SI-VOF model, with an enhanced capability of moving the liquid-vapor interface, against the draining segment of the EDU experiment. The VOF-CFD model was also used to simulate tank draining and its results were compared with the results of the Sharp Interface model with the moving interface. Both models predict tank pressure during draining within 3.5% of the measured values. Pressure decrease rate is underpredicted by both models during the first 100 seconds of draining but matches the experimental rate for the rest of the simulation.

Computational Fluid Dynamics↗

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting↗

Dust Tolerant Commodity Transfer Interface Mechanisms for Planetary Surfaces

Regolith is present on most planetary surfaces such as Earth's moon, Mars, and Asteroids. If human crews and robotic machinery are to operate on these regolith covered surfaces, they must face the consequences of interacting with regolith fines which consist of particles below 100 microns in diameter down to as small as submicron scale particles. Such fine dust will intrude into mechanisms and interfaces causing a variety of problems such as contamination of clean fluid lines, jamming of mechanisms and damaging connector seals and couplings. Since multiple elements must be assembled in space for system level functionality, it will be inevitable that interfaces will be necessary for structural connections, and to pass commodities such as cryogenic liquid propellants, purge and buffer gases, water, breathing air, pressurizing gases, heat exchange fluids, power and data. When fine regolith dust is present in the environment it can be lofted into interfaces where it can compromise the utility of the interface by preventing the connections from being successfully mated, or by inducing fluid leaks or degradation of power and data transmission. A dust tolerant, hand held "quick-disconnect" cryogenic fluids connector housing has been developed at NASA KSC which can be used by astronaut crews to connect flex lines that will transfer propellants and other useful fluids to the end user. In addition, a dust tolerant, automated, cryogenic fluid, multiple connector, power and data interface mechanism prototype has been developed, fabricated and demonstrated by NASA at Kennedy Space Center (KSC). The design and operation of these prototypes are explained and discussed.

Dust Tolerant↗

CFD and Thermodynamic Model Predictions of No-Vent Tank Filling in Microgravity

Cryogenic Fluid Management (CFM) of propellant fluids under low gravity conditions present an important challenge in the pursuit of NASA’s future long-duration space missions. Success of these missions relies to a large extent on the ability to store and transfer the cryogenic liquid fuels efficiently and safely. To this end, the Zero-Boil-Off Tank Filling and Transfer Experiment (ZBOT-FT) undertaken by University of Bremen in collaboration with Case Western Reserve University aims at studying two phase flow tank-to-tank transfer operations in microgravity using a simulant fluid, Perfluoro-n-pentane (PNP). As part of this effort, in this work, we present a system level homogeneous thermodynamic model and a two-phase Computational Fluid Dynamics (CFD) model of a no-vent cylindrical tank filling in microgravity. Both 2D axisymmetric and 3D parametric simulations case studies are performed to show the detailed physics of the filling process and the evolution of tank pressure for filling flow rates between 1.0 and 1.65 mL/s. A zero-dimensional homogeneous thermodynamic model is also developed to predict the final steady state tank pressure analytically. Comparison of the 2D and 3D CFD predictions of final pressures to the steady state thermodynamic results displays very good agreement. However, it is shown that the 2D axisymmetric model predicts a maxima in tank pressure before reaching steady state. It is indicted that this pressure maxima is caused by the constraints inherent in the axisymmetric model and is absent in the 3D and thermodynamic pressure predictions.

Two Phase Flow↗

Cryogenic Flow Boiling Parabolic Flight Experiment and Universal Correlations for Cryogens

Cryogenic fluids are employed in many industries and play crucial roles in space applications, including nuclear thermal propulsion systems, LOX/LCH4 ascent and descent stage feedlines, LOX/LH2 transfer lines for in-space fuel depots, and LHe transfer lines that cool space experiments. Due to the ultra-low boiling point of cryogens, phase change is inevitable in these systems, which leads to complex boiling behavior in reduced gravity. For cost-effective design and sizing of the aforementioned systems, accurate knowledge of two-phase parameters such as pressure drop, heat transfer coefficient (HTC), and critical heat flux (CHF) is desired. Since 2018, researchers from Purdue University and NASA Glenn Research Center (GRC) have been collaborating to investigate the effects of reduced gravity on cryogenic pool boiling, flow boiling ins tubes, and spray cooling. Using a variety of both terrestrial and parabolic flight experimental rigs, extensive LN2 data have been amassed and combined with cryogenic data from World literature to develop both ‘universal’ empirical correlations and CFD models, which are expected to serve as foundation for design of future space systems involving cryogenic fluids. This presentation will provide an overview of both the experimental work and predictive tools that have resulted from the joined Purdue-Glenn studies.

Flow Boiling↗

Heat conduction errors and time lag in cryogenic thermometer installations

Installation practices are recommended that will increase rate of heat exchange between the thermometric sensing element and the cryogenic fluid, in addition to bringing about a reduction in the rate of undesired heat transfer to higher temperature objects. Formulas and numerical data are given that help to estimate the magnitude of heat conduction errors and of time lag in response.

Warshawsky, I.↗

Updated Human Mars Ascent Vehicle Concept in Support of NASA’s Strategic Analysis Cycle 2021

The NASA Artemis program has brought significant change to the agency’s human exploration strategy over the last several years. The human exploration of Mars remains an ultimate objective of the overall human exploration strategy. However, how the agency intends to execute initial human exploration of Mars has shifted to better align with current policy. These changes find their way into the design of key architecture elements, such as the Mars Ascent Vehicle (MAV). Of the numerous changes in the conceptual human Mars architecture, two in particular have had significant impact on the design of the human MAV: the desire for minimal surface infrastructure for initial human Mars missions, and technology investment timelines in support of initial human missions to Mars. The first leads to a surface mission architecture targeting a 30-day surface duration with two crewmembers. The second drives out in-situ resource utilization (ISRU) from the initial sortie. As a result, the reference MAV design for initial human Mars missions in the Human Exploration and Operations Mission Directorate’s Strategic Analysis Cycle 2021 (SAC21) is based around supporting the return of 2 crew from the surface of Mars, without surface ISRU. This has led to several design changes since 2019, when details of a reference human MAV were last published. The MAV concept for SAC21 consists of a two-stage vehicle capable of supporting two crew for 84 hours. This duration is derived from a baseline ascent trajectory targeting an apoapsis rendezvous with the habitation element in a nominal 5-sol Mars aggregation orbit. With the goal of minimizing technology investments for the initial surface sortie removing ISRU from the trade space, the MAV must now be landed either fully loaded with propellant, or with some portion of the propellant off-loaded. Landing a partially-fueled MAV will require additional surface assets to perform robotic propellant transfer on the surface of Mars from a pre-emplaced propellant depot. Furthermore, cryogenic fluid management and storage for extended duration with no losses represents additional technology investment that would have to be made to support cryogenic-based propellant concepts that have been the baseline in past architectures. As a result, the SAC21 architecture utilizes a storable propellant-based MAV propulsion system to minimize these potential technology investments incurred by cryogenic-based propulsion systems. Recent efforts also focused on evaluating the sensitivity of key design parameters, such as landing site latitude, elevation, and local atmospheric conditions. All play a large role in determining the predicted propellant requirements of the MAV. Understanding their potential impacts is important because of the rippling effects of changes to the MAV design on other architecture elements, such as entry, descent, landing, and transportation systems. Results indicate up to +2% to -4% wet mass variation due to landing site latitude, with higher latitudes greater than 70 degrees North resulting in greater than 6% wet mass increases. The MAV saw reduced impact due to atmospheric design parameters, which only accounting for -0.6% to +0.4% wet mass variation.

Douglas J. Trent↗

Loci/STREAM Sharp Interface Model Validation of Cryogenic Propellant Tank Self-Pressurization

This paper documents a model validation effort for the prediction of cryogenic propellant tank selfpressurization physics using the Loci/STREAM sharp interface CFD model developed at NASA MSFC. Cryogenic fluid management (CFM) applications for long duration spaceflight missions require accurate modeling of heat transfer and thermodynamics. Therefore, detailed validation of those physics is important to ensure simulation accuracy. In the past, the MSFC Propulsion Fluid Dynamics Branch has validated and used the Loci/STREAM Volume of Fluid (VOF) module extensively for propellant slosh applications, which are dominated by fluid motion. For cases where the interface gas/liquid interface is essentially static, the Loci/STREAM sharp interface was developed for more rapid and efficient CFM analysis. In the present study, Loci/STREAM sharp interface simulations were compared with the NASA K-site self-pressurization experiment of a flight weight, partially full, LH2 tank in normal gravity. This study investigated several parametric effects and made a number of important observations on the performance of the Loci/STREAM sharp interface method: - First, a homogeneous model was derived to verify the CFD model. The homogeneous model assumes both gas and liquid phases are uniform and are at saturation temperature. The predicted pressure rise rates at 3.5 W/m2 and 2.0 W/m2 with a 49% fill level are all lower than the experimental measurement. This is expected due to the observed temperature stratification near the gas-liquid interface during testing. - The k-w and k-e turbulence models predict comparable pressurization rates, which are much lower than the experiment measurement. On the other hand, the pressure values and pressurization rates from both models are almost the same as those of the homogeneous model. The current turbulence model is too diffusive and is not capable of capturing the thermal stratification in the liquid and ullage. - When using the laminar flow model, the pressurization rate is found to be very close to the experimental value when a quasi-steady flow field is allowed to develop by continuously venting the tank prior to pressurization as was done during testing. On the other hand, without initial venting, the rate is not constant. Additionally, the development time to reach a quasi-steady flow field differed from the experiment due to the lack of turbulent mixing away from the gas-liquid interface that is expected in reality. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 15% of the experimental value for 49% fill level at 3.5 W/m 2 and is within 18% for 2.0 W/m 2 heat loading. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 18% of the experimental value for a 29% fill level and within 15% for an 83% fill level.

H. Q. Yang↗

CFD Modeling & Validation of Single Bubble Growth During Cavitation in Zero Gravity

Cryogenic Fluid Management (CFM) in zero gravity represents a vital area of research as NASA pursues future long-duration space missions. Success of these missions relies heavily on the ability to store and transfer the cryogenic liquid fuels efficiently and safely. In the Zero Boil-Off Tank (ZBOT-1) Experiment in 2018, unexpected and intense phase change occurred at the screened Liquid Acquisition Device (LAD) during tank pressure control that was later attributed to cavitation. The cavitation ultimately resulted in pump failure. Since cryogen cavitation during storage and transfer of propellants in microgravity has been a source of serious concern for the aerospace community, a series of drop tower experiments with liquid methane were also performed at the University of Bremen to carefully study cavitation from a single bubble nucleus in an engineered micron-sized wall cavity. As the test cell is depressurized during the 10-second drop, cavitation causes bubble growth from the nucleus. Here, in a collaboration between the Case Western Reserve University and University of Bremen, we present a two-phase Computational Fluid Dynamics (CFD) model of bubble growth from a single wall cavity during depressurization in microgravity. Both 2D axisymmetric and 3D parametric simulation case studies are performed to show the evolution of the bubble growth. The model uses a Volume of Fluid (VOF) approach with and without adaptive mesh refinement and adaptive time stepping to capture the growth dynamics using an explicit formulation with algebraic reconstruction of the interface. CFD results show good agreement with corresponding experiment. Based on the velocity, temperature, and volume fraction fields generated by the validation case studies, detailed discussion and analysis of fluid flow and heat transfer during bubble growth process are presented to delineate the intricacies of the cavitation process. Strengths and shortcomings of the present numerical approach in capturing this phenomenon are also highlighted.

Two Phase Flow↗

Experimental Investigation of Flow Orientation Effects on Cryogenic Flow Boiling

Cryogenic flow boiling physics is of paramount importance for future cryogenic space applications employing Cryogenic Fluid Management (CFM) technologies. This experimental study investigates the two-phase flow and heat transfer performance of LN 2 flow boiling across five distinct flow orientations: vertical upflow, vertical downflow, horizontal flow, 45° inclined upflow, and 45° inclined downflow. The study employed the steady- state heating method within a circular heated tube featuring an 8.5-mm inner diameter and a 680-mm heated length. High-speed video recordings were utilized to capture two-phase flow patterns and interfacial behaviors across various flow orientations. The experiments covered a wide range of operating conditions, including mass velocities ranging from 351.80 to 1572.77 kg/m 2 s and inlet pressures from 297.14 to 1032.97 kPa, primarily with near-saturated inlet subcooling. Distinct two-phase flow patterns and regime transitions were identified for each flow orientation. Symmetrical flow patterns were evident in vertical orientations, whereas non-vertical orientations exhibited asymmetric flow stratifications, primarily influenced by the buoyancy force in a terrestrial gravity environment. Bubble dynamic parameters were quantified, and bubble collision and dispersion phenomena were visualized. Analyzing heat transfer performance based on local flow boiling curves and variations in heat transfer coefficients (HTCs), it was observed that vertical upflow demonstrated the most enhanced heat transfer performance, while vertical downflow exhibited the lowest. As mass velocity exceeded 830 kg/ m 2 s, the differences in heat transfer among orientations became less distinct, emphasizing the role of flow inertia in mitigating the influence of flow orientation. A direct comparison of microgravity HTC data from a recent study by the authors against the 1-𝘨 e HTC data indicated enhanced heat transfer performance in microgravity for flow orientation configurations in terrestrial gravity. However, this enhancement progressively diminished as the heat flux increased. Distinct HTC trends were observed as mass velocity increased for different flow orientations and gravity levels.

Cryogens↗

Zero-gravity transient thermal mixing simulation

The experimental program described is an outgrowth of independent investigations into alternate redesign concepts for the Apollo SM cryogenic oxygen storage system. The experiments were continued, after the redesign was established, to provide physical insight into transient thermal mixing in zero-gravity and to aid in the characterization of the system performance in flight. Zero-gravity heat transfer and fluid mixing were simulated experimentally through an analogy between unsteady heat conduction and species diffusion. To further support numerical analyses of the cryogenic oxygen storage system, the experimental investigation was extended to include a cubical tank geometry, representative of existing numerical models. In general, the transient flow patterns in the cubical tank are far more complex than those of the spherical tank and the extent of fluid mixing is significantly greater but less repeatable.

Lands, J. F., Jr.↗

CFD Modeling of Phase Change and Pressure Drop during Violent Sloshing of Cryogenic Fluid in a Small-Scale Tank

This paper presents the development of a two-phase CFD model that is used to study sloshing of a cryogenic fluid (LN2) undergoing phase change generated by lateral acceleration and its effects on the ensuing heat and mass transfer and pressure drop in a small-scale tank. In this model the interface is captured using the volume-of-fluid (VOF) method [1]. Kinetic-theory based Schrage relation [2] is used for calculating phase change mass transfer at the liquid-vapor interface. Computational results are compared to the data provided by a non-isothermal sloshing experiment with phase change conducted by the University of Tokyo and JAXA in 2018 using liquid Nitrogen in a transparent tank. The effect of different thicknesses of a liquid temperature stratification layer created at the interface on the pressure drop during sloshing was studied experimentally. CFD results for interface movement and tank pressure are presented and compared in this paper to experimental data for the cases with the smallest and largest liquid temperature stratification thickness.

phase change↗