Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic liquids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Modeling of hydrogen liquefaction using magnetocaloric cycles with permanent magnets

Hydrogen (H 2 ) is promising alternative to replace fossil fuels, but its transport and storage has been challenging. As H 2 fuel cell vehicles are gaining traction, the infrastructure for storing large amounts of liquid H 2 is needed. However, liquid H 2 would suffer from boil-off loss, and traditional vapor compression refrigeration systems would not be able to economically recover the lost H 2 due to the low efficiencies at cryogenic temperature. Magnetocaloric (MC) refrigeration systems could possess much higher coefficient of performance (COP) at cryogenic temperature compared to the vapor compression ones. Previous work on cryogenic MC systems, however, have only focused on large scale applications which use superconducting magnets to provide a large magnetic field but are prohibitively expensive to operate for small scale applications, such as that of a H 2 refilling station. In this work, we model the performance of a MC refrigeration cycle using 1-Tesla permanent magnets for H 2 liquefaction, with the objective of cooling H 2 from 80 K (using liquid nitrogen as the heat sink) to 20 K (boiling point of hydrogen). We evaluate main performance metrics including the total work input to the refrigeration system, COP, total MCM mass in the system, and total volume of the permanent magnets, etc. Our modeling results indicate that such a permanent magnet-based MC cooling system is feasible for small-scale H 2 liquefaction, with projected COP values significantly higher than those of vapor compression systems. In conclusion, this work provides design guidelines for future experimental efforts on permanent magnet MC cooling systems for cryogenic cooling.

08 HYDROGEN↗

Characteristic of cryogenic hydrogen flames from high-aspect ratio nozzles

Unintentional leaks at hydrogen fueling stations have the potential to form hydrogen jet flames, which pose a risk to people and infrastructure. The heat flux from these jet flames are often used to develop separation distances between hydrogen components and buildings, lot-lines, etc. The heat flux and visible flame length is well understood for releases from round nozzles, but real unintended leaks would be expected to be from higher aspect-ratio cracks. Here, we measured the visible flame length and heat-flux characteristics of cryogenic hydrogen flames from high-aspect ratio nozzles. Heat flux measurements from 5 radiometers were used to assess the single-point vs the multi-point methods for interpretation of heat flux sensor data, finding the axial distance of the sensor for a single-point heat flux measurement to be important. We compare the flame length and heat flux data to flames of both cryogenic and compressed hydrogen from round nozzles. The aspect ratio of the release does not affect the flame length or heat flux significantly, for a given mass flow under the range of conditions studied. The engineering correlations presented in this work enable the prediction of flame length and heat flux which can be used to assess risk at hydrogen fueling stations with liquid hydrogen and develop science-based separation distances for these stations.

08 HYDROGEN↗

The electric field dependence of single electron emission in the PIXeY two-phase xenon detector

Dual phase xenon detectors are widely used in experimental searches for galactic dark matter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. Here, in this paper, we describe single electron backgrounds in 83m Kr calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.

47 OTHER INSTRUMENTATION↗

Lessons from commissioning of the cryogenic system for the Short-Baseline Neutrino Detector at Fermilab

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector is installed in a 200 m3 membrane cryostat filled with liquid argon, which serves both as target and as active media. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions while the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector is operated in Booster Neutrino Beams (BNB) at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The cryostat and the cryogenic systems also serve as prototypes for the much larger equipment to be used for the LBNF/DUNE experiment. Since its installation in 2018-2023 and cooldown in spring of 2024, the cryostat and the cryogenic system have been commissioned to support the detector operations. The lessons learned through installation, testing, commissioning, cooldown, and initial operations are described.

Geynisman, Michael [Fermilab]↗

Liquid electrolytes for low-temperature lithium batteries: main limitations, current advances, and future perspectives

Lithium-ion batteries (LIBs) can now be used in almost all modern electronic devices and electric vehicles. However, as the range of applications increases, the challenges increase as well, especially at very low temperatures. Many individual processes could result in capacity loss of LIBs at low temperatures; however, most of them are associated with the liquid electrolyte inside the battery. In this review, we first discuss the main limitations in developing liquid electrolytes used in low-temperature LIBs, and then we summarize the current advances in low-temperature electrolytes, including lithium salts, solvents, additives, and new strategies. Finally, we present some perspectives on the current state of low-temperature electrolytes for LIBs, outlining the most promising research areas in this field. In conclusion, this review will provide useful insights into the design of cryogenic electrolytes and the path forward to the widespread use of LIBs in cryogenic environments.

25 ENERGY STORAGE↗

Lessons from commissioning of the cryogenic system for the Short-Baseline Neutrino Detector at Fermilab

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector is installed in a 200 m$^3$ membrane cryostat filled with liquid argon, which serves both as target and as active media. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions while the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector is operated in Booster Neutrino Beams (BNB) at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The cryostat and the cryogenic systems also serve as prototypes for the much larger equipment to be used for the LBNF/DUNE experiment. Since its installation in 2018-2023 and cooldown in spring of 2024, the cryostat and the cryogenic system have been commissioned to support the detector operations. The lessons learned through installation, testing, commissioning, cooldown, and initial operations are described.

43 PARTICLE ACCELERATORS↗

Investigating Cryogenic Pump Lifetime and Exploring Alternative Designs

Cryogenic pumps are necessary for the operation of several neutrino experiments at Fermilab where some of the primary components of the detectors are liquid argon and liquid nitrogen. The pumps currently in use are centrifugal pumps with a small vortex impeller, manufactured by Barber Nichols. This pump has an average lifetime of 8000 hours. Such a short lifetime means that each pump requires maintenance multiple times a year, which is not optimal. The goal of this project was to determine what aspects of the current pump design could be modified to improve the lifetime of the pump such that it would only require maintenance once a year. In this poster I present on the different areas of design improvement that were identified.

Baakkonen, Katie↗

Numerical predictions of cryogenic hydrogen vertical jets

Here, a comparison of Computational Fluid Dynamics (CFD) predictions with measurements is presented for cryo-compressed hydrogen vertical jets. The stagnation conditions of the experiments are characteristic of unintended leaks from pipe systems that connect cryogenic hydrogen storage tanks and could be encountered at a fuel cell refueling station. Jets with pressure up to 5 bar and temperatures just above the saturation liquid temperature were examined. Comparisons are made to the centerline mass fraction and temperature decay rates, the radial profiles of mass fraction and the contours of volume fraction. Two notional nozzle approaches are tested to model the under-expanded jet that was formed in the tests with pressures above 2 bar. In both approaches the mass and momentum balance from the throat to the notional nozzle are solved, while the temperature at the notional nozzle was assumed equal to the nozzle temperature in the first approach and was calculated by an energy balance in the second approach. The two approaches gave identical results. Satisfactory agreement with the measurements was found in terms of centerline mass fraction and temperature. However, for test with 3 and 4 bar release the concentration was overpredicted. Furthermore, a wider radial spread was observed in the predictions possibly revealing higher degree of diffusion using the k-ε turbulence model. An integral model for cryogenic jets was also developed and provided good results. Finally, a test simulation was performed with an ambient temperature jet and compared to the cold jet showing that warm jets decay faster than cold jets.

08 HYDROGEN↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗

Movable Thermometer System in ProtoDUNE

The movable temperature profiler is a 7 m vertical array of 24 sensors that measures cryogenic temperatures with a precision of a few mK. This precision is necessary to monitor the efficiency of re-circulation and purification of liquid-argon inside large liquid-argon based neutrino detectors. Liquid argon temperature impacts electron (signal) drift velocity, flow, purity distribution and thus the overall energy calibration. The temperature profiler is motorized and moves vertically, while in the detector, and cross-calibrates neighboring sensors. The temperature offsets between each sensor cancel the effects of electromagnetic noise. This poster reports on the temperature measurements and such in-situ cross-calibrations at ProtoDUNE (single phase) at CERN.}

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

Difficult Measurements of Materials Systems at Cryogenic Temperatures: Cryo-EELS and Cryo-4D-STEM

Scanning/transmission electron microscopy (S/TEM) in materials science has traditionally been accomplished at room temperature due to their solid state in this temperature range and relative insensitivity to radiolysis damage. Cooling to cryogenic temperatures tended to introduce instabilities such as vibration and drift and can lead to the buildup of carbon contamination or ice reducing contrast. The need to expand TEM experimental techniques into new fields such as quantum and battery materials led to new efforts to reduce these instabilities while achieving temperatures at or well below liquid nitrogen (77 K). Further, developments in detector and spectrometer technology brought new capabilities for high resolution electron energy loss spectroscopy (EELS) and scanning nanodiffraction (4D-STEM). These experimental modalities can require even tighter controls of drift, vibration, and exposure time. Here this presentation will discuss accomplishing difficult experiments at cryogenic temperatures in honor of the late Dr. Lena Kourkoutis who inspired and led many such experiments.

36 MATERIALS SCIENCE↗

Monitoring the Reaction Dynamics of UF6 by Cryogenic Layering and FTIR Spectroscopy

Uranium hexafluoride (UF6) is a commonly used material feedstock for uranium enrichment processes. When introduced to water in the atmosphere, it reacts rapidly to form uranyl fluoride (UO2F2). Here, we investigate the UF6 hydrolysis reaction by cryogenically trapping reaction intermediates and characterizing the trapped species by FTIR. The reactant species are sequentially layered onto a diamond substrate held at 10K by a closed cycle liquid helium cryostat. At this temperature, the hydrolysis reaction is not spontaneous and can be catalyzed by the introduction of heat. Upon heating, the reaction moves through several intermediate compounds before proceeding to the final UO2F2 product. Several previously unobserved bands appear while the reaction progresses which may help to elucidate the mechanism behind UF6 hydrolysis.

McNamara, III, Louis E.↗

Optimization of the light detection system of the ICARUS detector

The Short Baseline Neutrino (SBN) Program at Fermilab is designed to investigate short-baseline neutrino oscillations and test the hypothesis of sterile neutrinos, motivated by several experimental anomalies observed over the past decades. Within this program, the ICARUS experiment plays a key role. It employs the world’s largest Liquid Argon Time Projection Chamber (LArTPC) and serves as the farthest and most sensitive SBN detector for studying muon and electron neutrino oscillations. A crucial subsystem of the ICARUS detector is the Light Detection System (LDS), which captures the prompt scintillation light produced by neutrino interactions in the 600-ton active liquid Argon volume. This system provides precise timing information that is essential for event reconstruction, the trigger system, and cosmic background rejection. The LDS is composed of 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), operating under cryogenic conditions ($\sim 87 \ K$) inside the detector’s cryostats. During the detector’s operation at FNAL, a degradation in PMT gain has been observed, attributed to aging under low-temperature conditions. In collaboration with ICARUS teams from INFN Pavia and Catania, I developed an experimental setup to study the temperature-dependent behavior of the PMTs, performing gain measurements both at room temperature and down to $-70°C$ using a climatic chamber at INFN Catania. The results indicate that while the PMTs maintain stable gain at room temperature, a significant and permanent gain reduction occurs at low temperatures. Although $-70°C$ is still warmer than liquid Argon temperatures, the findings clearly demonstrate a gain-dependent performance degradation. The thesis also discusses mitigation strategies implemented in the ICARUS detector to address this issue and presents a simplified model to describe and simulate the observed behavior.

Saia, Clara [Catania U.] (ORCID:0009000464102417)↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗