Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Novel Infrared-blocking Aerogel Scattering Filters and Their Applications in Astrophysical and Planetary Science Observations

Infrared-blocking scattering aerogel filters have a broad range of potential applications in astrophysics and planetary science observations in the far-infrared, sub-millimeter, and microwave regimes. Successful dielectric modeling of aerogel filters allowed the fabrication of samples to meet the mechanical and science instrument requirements for several experiments, including the Sub-millimeter Solar Observation Lunar Volatiles Experiment (SSOLVE), the Cosmology Large Angular Scale Surveyor (CLASS), and the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). Thermal multi-physics simulations of the filters predict their performance when integrated into a cryogenic receiver. Prototype filters have survived cryogenic cycling to 4 K with no degradation in mechanical properties.

Kyle R Helson↗

Airborne Visible/Infrared Imaging Spectrometer 3 (AVIRIS-3)

The Airborne Visible/Infrared Imaging Spectrometer 3 (AVIRIS-3) is the third of the NASA AVIRIS spectrometer series and is being developed in parallel with the Compact Wide-swath Imaging Spectrometer II (CWIS-II) for the University of Zurich, Switzerland. The core spectrometer of AVIRIS-3 is a copy of the optically fast, F/1.8 Dyson imaging spectrometer used by the Earth Surface Mineral Dust Source Investigation (EMIT) that is in development and scheduled for launch to the International Space Station (ISS) in 2022. AVIRIS-3 is intended to provide state-of-the-art imaging spectroscopy measurements for NASA science and application through the next decade and beyond. AVIRIS-3 uses the EMIT spectrometer design interfaced with a scaled two mirror telescope enclosed in a portable vacuum vessel to enable measurements from airborne platforms ranging from a Twin Otter to a business jet or a NASA ER-2. AVIRIS-3 is a cryogenic instrument with advanced system control and real-time onboard spectroscopic data processing algorithms evolved from AVIRIS-NG. The spectral range of AVIRIS-3 is 380 to 2500 nm with 7.4 nm sampling. The radiometric range is from 0 to max terrestrial Lambertian radiance with higher signal-to-noise ratio performance than AVIRIS-Classic or AVIRIS-Next Generation. The spatial field-of-view is 39.5 degrees with 0.56 milliradian sampling. This paper describes the design and development of AVIRIS-3 and presents its characteristics in comparison to the previous generation imaging spectrometers.

Helmlinger, Mark↗

User's manual for a 0.3-m TCT wall interference assessment/correction procedure: 8- by 24-inch airfoil test section

A transonic Wall-Interference Assessment/Correction (WIAC) procedure has been developed and verified for the 8- by 24-inch airfoil test section of the Langley 0.3-m Transonic Cryogenic Tunnel. This report is a user's manual for the correction procedure. It includes a listing of the computer procedure file as well as input for and results from a step-by-step sample case.

Gumbert, C. R.↗

Thermal Conductances Of Metal Contacts

Report presents results of measurements of thermal conductances of aluminum and stainless-steel contacts at temperatures from 1.6 to 6.0 K. Measurement apparatus includes gearmotor assembly connected to rocker arm by music wire to load sample pair with forces up to 670 N. Heater placed above upper sample. Germanium resistance thermometers in upper and lower samples measured temperature difference across interface over range of heater powers from 0.1 to 10.0 mW. The thermal conductance calculated from temperature difference. Measurements provide data for prediction of thermal conductances of bolted joints in cryogenic infrared instruments.

Salerno, L. J.↗

An Investigation of Aerosol and Ozone Measurements from the Cryogenic Limb Array Etalon Spectrometer: Validation and Relation to Other Chemical Species

Throughout this study we focused on comparisons of CLAES and in situ measurements of ozone and aerosol extinction. Thus the comparison is between satellite data representative of large spatial regions and in situ data representative of nearly point samples. Both instruments provide vertical profiles, but the region of overlap is limited to between approximately 10 and 100 mb. CLAES Version 7 ozone measurements have been compared to electrochemical cell ozonesonde measurements over McMurdo Station, Antarctica (78 deg S, 167 deg E), Dumont d'Urville, Antarctica (66.7 deg S, 140 deg E), Laramie, Wyoming (41 deg N, 106 deg W), and Bear Island, Norway (74.3 deg N, 19 deg E). Comparisons were made between vertical ozone profiles, and between integrated column ozone over the region of overlap of the measurements. Comparisons using CLAES Version 8 data are underway. CLAES Version 8 aerosol extinction measurements at all wavelengths have also been compared to University of Wyoming aerosol extinctions over McMurdo Station, Antarctica, and over Laramie, Wyoming. Coincidences in all cases were determined by minimizing the distance between the CLAES observations and the surface station, and the time separation between the satellite and in situ measurements.

Deshler, Terry↗

Teflon FEP Analyzed After Retrieval From the Hubble Space Telescope

During the Hubble Space Telescope (HST) Second Servicing Mission, 6.8 years after the telescope was deployed in low Earth orbit, degradation of unsupported Teflon FEP (DuPont; fluorinated ethylene propylene), used as the outer layer of the multilayer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer (see the photograph) was retrieved during the second servicing mission and returned to Earth for ground testing and evaluation. Also retrieved was a Teflon FEP radiator surface from a cryogen vent cover that was exposed to the space environment on the aft bulkhead of the HST. NASA Goddard Space Flight Center directed the efforts of the Hubble Space Telescope MLI Failure Review Board, whose goals included determining the FEP degradation mechanisms. As part of the investigations into the degradation mechanisms, specimens retrieved from the first and second HST servicing missions, 3.6 and 6.8 years after launch, respectively, were characterized through exhaustive mechanical, optical, and chemical testing. Testing led by Goddard included scanning electron microscopy, optical microscopy, tensile testing, solar absorptance measurements, time-of-flight secondary ion mass spectroscopy (TOF-SIMS), Fourier transform infrared microscopy (m-FTIR), attenuated total reflectance infrared microscopy (ATR/FTIR), and x-ray diffraction (XRD). The NASA Lewis Research Center contributed significantly to the analysis of the retrieved HST materials by leading efforts and providing results of bend testing, surface microhardness measurements, x-ray photoelectron spectroscopy, solid-state nuclear magnetic resonance spectroscopy, and density measurements. Other testing was conducted by Nano Instruments, Inc., and the University of Akron.

Dever, Joyce A.↗

Desert Research and Technology Studies 2005 Report

During the first two weeks of September 2005, the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) Advanced Extravehicular Activity (AEVA) team led the field test portion of the 2005 Research and Technology Studies (RATS). The Desert RATS field test activity is the culmination of the various individual science and advanced engineering discipline areas year-long technology and operations development efforts into a coordinated field test demonstration under representative (analog) planetary surface terrain conditions. The purpose of the RATS is to drive out preliminary exploration concept of operations EVA system requirements by providing hands-on experience with simulated planetary surface exploration extravehicular activity (EVA) hardware and procedures. The RATS activities also are of significant importance in helping to develop the necessary levels of technical skills and experience for the next generation of engineers, scientists, technicians, and astronauts who will be responsible for realizing the goals of the Constellation Program. The 2005 Desert RATS was the eighth RATS field test and was the most systems-oriented, integrated field test to date with participants from NASA field centers, the United States Geologic Survey (USGS), industry partners, and research institutes. Each week of the test, the 2005 RATS addressed specific sets of objectives. The first week focused on the performance of surface science astro-biological sampling operations, including planetary protection considerations and procedures. The second week supported evaluation of the Science, Crew, Operations, and Utility Testbed (SCOUT) proto-type rover and its sub-systems. Throughout the duration of the field test, the Communications, Avionics, and Infomatics pack (CAI-pack) was tested. This year the CAI-pack served to provide information on surface navigation, science sample collection procedures, and EVA timeline awareness. Additionally, 2005 was the first year since the Apollo program that two pressurized suited test subjects have worked together simultaneously. Another first was the demonstration of recharge of cryogenic life support systems while in-use by the suited test subjects. The recharge capability allowed the simulated EVA test duration to be doubled, facilitating SCOUT proto-type rover testing. This paper summarizes Desert RATS 2005 test hardware, detailed test objectives, test operations and test results.

Ross, Amy J.↗

Optimal three-dimensional reusable tug trajectories for planetary missions including correction for nodal precession

Equations are derived by using the maximum principle to maximize the payload of a reusable tug for planetary missions. The analysis includes a correction for precession of the space shuttle orbit. The tug returns to this precessed orbit (within a specified time) and makes the required nodal correction. A sample case is analyzed that represents an inner planet mission as specified by a fixed declination and right ascension of the outgoing asymptote and the mission energy. The reusable stage performance corresponds to that of a typical cryogenic tug. Effects of space shuttle orbital inclination, several trajectory parameters, and tug thrust on payload are also investigated.

Borsody, J.↗

Measurements of the global distribution of carbon monoxide in the troposphere

Carbon monoxide and methane grab samples were obtained simultaneously with ozone, aerosol, nitric oxide and DACOM CO measurements. Eighty grab samples were collected at various altitudes up to 19,000 ft. along a north-south flight path from Wallops Flight Center, VA to 11 N. CO and CH were analyzed by flame ionization gas chromatography with cryogenic preconcentration. The relationship between CO and O3 concentrated is examined. A comparative analysis between trends in aerosol and CO concentration is performed.

Hinton, R. R.↗

Trajectory Hunting: A Case Study of Rapid Chlorine Activation in December 1992 as Seen by UARS

Trajectory hunting (i.e., a technique to find air parcels sampled at least twice over the course of a few days) is applied to analyze Upper Atmosphere Research Satellite (UARS) measurements in conjunction with the Atmospheric and Environmental Research, Inc. (AER) photochemical box model. As a case study, we investigate rapid chlorine activation in the Arctic lower stratosphere on December 29, 1992 associated with a polar stratospheric cloud (PSC) event. Eleven air parcels that have been sampled several times along 5-day trajectories at the 465 K (approx. 46 hPa), 520 K (approx. 31 hPa), and 585 K (approx. 22 hPa) levels were investigated. For the first time, the latest versions of the Cryogenic Limb Array Etalon Spectrometer (CLAES, version 9) and Microwave Limb Sounder (MLS, version 5) data sets are analyzed, and their consistency is assessed. A detailed sensitivity study with the AER photochemical box model along these trajectories leads to the conclusion that for the December 24-29, 1992 episode (1) the individual CLAES version 9 ClONO2 and MLS version 5 ClO measurements are self-consistent within their uncertainties; and (2) most of the time, UARS measurements of ClO, ClONO2, HNO3, and aerosol extinction at 780 cm (exp -1) agree within the range of their uncertainties with the model calculations. It appears that the HNO3 and aerosol extinction measurements for four parcels at 520 K look more supportive for the nitric acid trihydrate (NAT) scheme. However, the uncertainties in the individual UARS measurements and U.K. Meteorological Office temperature do not allow a definite discrimination between the NAT and supercooled ternary solution (STS) PSC schemes for this chlorine activation episode in December 1992.

Danilin, M. Y.↗

Comparison of Upper Tropospheric Water Vapor from AIRS and Cryogenic Frostpoint Hygrometers

Upper tropospheric water vapor (UTWV) from the Atmospheric Infrared Sounder (AIRS) experiment on NASA's Aqua spacecraft has the potential of addressing several important climate questions. The specified AIRS system measurement uncertainty for water vapor is 20 percent absolute averaged over 2 km layers. Cryogenic frostpoint hygrometers (CFH) are balloon-borne water vapor sensors responsive from the surface into the lower stratosphere. Several dozen coincident, collocated CFH profiles have been obtained for AlRS validation. The combination of CFH sensitivity and sample size offers a statistically compelling picture of AIRS UTWV measurement capability. We present a comparison between CFH observations and AlRS retrievals. We focus on the altitude range from the middle troposphere up to heights at the limits of AlRS sensitivity to water vapor, believed to be around 100-1 50 hPa.

validation↗

Volatile Analyzer for Lunar Polar Missions

One of the major questions remaining for the future exploration of the Moon by humans concerns the presence of volatiles on our nearest neighbor in space. Observational studies, and investigations involving returned lunar samples and using robotic spacecraft infer the existence of volatile compounds particularly water [1]. It seems very likely that a volatile component will be concentrated at the poles in circumstances where low-temperatures exist to provide cryogenic traps. However, the full inventory of species, their concentration and their origin and sources are unknown. Of particular importance is whether abundances are sufficient to act as a resource of consumables for future lunar expeditions especially if a long-term base involving humans is to be established. To address some of these issues requires a lander designed specifically for operation at a high-lunar latitude. A vital part of the payload needs to be a volatile analyzer such as the Gas Analysis Package specifically designed for identification quantification of volatile substances and collecting information which will allow the origin of these volatiles to be identified [1]. The equipment included, particularly the gas analyzer, must be capable of operation in the extreme environmental conditions to be encountered. No accurate information yet exists regarding volatile concentration even for sites closer to the lunar equator (because of contamination). In this respect it will be important to understand (and thus limit) contamination of the lunar surface by extraneous material contributed from a variety of sources. The only data for the concentrations of volatiles at the poles comes from orbiting spacecraft and whilst the levels at high latitudes may be greater than at the equator, the volatile analyzer package under consideration will be designed to operate at the highest specifications possible and in a way that does not compromise the data.

Gibons, Everett K.↗

Trajectory Hunting: A Case Study of Rapid Chlorine Activation in December 1992 as Seen by UARS

Trajectory hunting (i.e., a technique to find air parcels sampled at least twice over the course of a few days) is applied to analyze Upper Atmosphere Research Satellite (UARS) measurements in conjunction with the Atmospheric and Environmental Research, Inc. (AER) photochemical box model. As a case study, we investigate rapid chlorine activation in the Arctic lower stratosphere on December 29, 1992 associated with a polar stratospheric cloud (PSC) event. Eleven air parcels that have been sampled several times along five-day trajectories at the 465 K (approx. 46 hPa), 520 K (approx. 31 hPa), and 585 K (approx. 22 hPa) levels were investigated. For the first time, the latest versions of the Cryogenic Limb Array Etalon Spectrometer (CLAES, version 9) and Microwave Limb Sounder (MLS, version 5) data sets are analyzed, and their consistency is assessed. A detailed sensitivity study with the AER photochemical box model along these trajectories leads to the conclusion that for the December 24-29, 1992 episode: (1) the individual CLAES ClONO2 and MLS ClO measurements are self-consistent within their uncertainties; and (2) most of the time, UARS measurements of ClO, ClONO2, HNO3, and aerosol extinction at 780 cm(exp -1) agree within the range of their uncertainties with the model calculations. It appears that the HNO3 and aerosol extinction measurements for four parcels at 520 K look more supportive for the nitric acid trihydrate (NAT) scheme, However, the uncertainties in the individual UARS measurements and UK Meteorological Office temperature do not allow a definite discrimination between the NAT and supercooled ternary solution (STS) PSC schemes for this chlorine activation episode in December 1992.

Danilin, M. Y.↗

Argon/UF6 plasma exhaust gas reconstitution experiments using preheated fluorine and on-line diagnostics

The feasibility of employing a flowing, high-temperature, pure fluorine/UF6 regeneration system to efficiently convert a large fraction of the effluent plasma exhaust back to pure UF6 was demonstrated. The custom built T.O.F. mass spectrometer sampling system permitted on-line measurements of the UF6 concentration at different locations in the exhaust system. Negligible amounts ( 100 ppm) of UF6 were detected in the axial bypass exhaust duct and the exhaust ducts downstream of the cryogenic trap system used to collect the UF6, thus verifying the overall system efficiency over a range of operating conditions. Use of a porous Monel duct as part of the exhaust duct system, including provision for injection of pure fluorine, provided a viable technique to eliminate uranium compound residue on the inside surface of the exhaust ducts. Typical uranium compound mass deposition per unit area of duct was 2 micron g/sq cm. This porous duct technique is directly applicable to future uranium compound transfer exhaust systems. Throughout these experiments, additional basic data on the corrosion aspects of hot, pressurized UF6/fluorine were also accumulated.

Roman, W. C.↗

Development of a Submillimeter-Wavelength Immersion Grating Spectrometer

The broad goal of this project was to develop a broadband, moderate-resolution spectrometer for submillimeter wavelengths. Our original approach was to build an immersion grating spectrometer, and as such, the first step was to identify the best material (lowest loss, highest index) for the grating medium, and to characterize its properties at the foreseen optical-bench operating temperature of 1.5 K. To this end, we put our initial efforts into upgrading an existing laboratory submillimeter Fourier transform spectrometer, which allowed us to carry out the requisite materials measurements. The associated cryogenic detector dewar was also redesigned and rebuilt to carry out this work. This dewar houses the 1.5 K detector and the filter wheel used in the materials characterization. Our goal was to have the beam propagate through the samples as uniformly as possible, so the optics were redesigned to allow for the samples to be traversed by a well-defined collimated beam. The optics redesign also placed the samples at an image of the aperture stop located within the FTS. After the rebuild, we moved into the testing phase.

Phillips, T. G.↗

Sensor Web in Antarctica: Developing an Intelligent, Autonomous Platform for Locating Biological Flourishes in Cryogenic Environments

The most rigorous tests of the ability to detect extant life will occur where biotic activity is limited by severe environmental conditions. Cryogenic environments are among the most severe-the energy and nutrients needed for biological activity are in short supply while the climate itself is actively destructive to biological mechanisms. In such settings biological activity is often limited to brief flourishes, occurring only when and where conditions are at their most favorable. The closer that typical regional conditions approach conditions that are actively hostile , the more widely distributed biological blooms will be in both time and space. On a spatial dimension of a few meters or a time dimension of a few days, biological activity becomes much more difficult to detect. One way to overcome this difficulty is to establish a Sensor Web that can monitor microclimates over appropriate scales of time and distance, allowing a continuous virtual presence for instant recognition of favorable conditions. A more sophisticated Sensor Web, incorporating metabolic sensors, can effectively meet the challenge to be in "the right place in the right time". This is particularly of value in planetary surface missions, where limited mobility and mission timelines require extremely efficient sample and data acquisition. Sensor Webs can be an effective way to fill the gap between broad scale orbital data collection and fine-scale surface lander science. We are in the process of developing an intelligent, distributed and autonomous Sensor Web that will allow us to monitor microclimate under severe cryogenic conditions, approaching those extant on the surface of Mars. Ultimately this Sensor Web will include the ability to detect and/or establish limits on extant microbiological activity through incorporation of novel metabolic gas sensors. Here we report the results of our first deployment of a Sensor Web prototype in a previously unexplored high altitude East Antarctic Plateau "micro-oasis" at the MacAlpine Hills, Law Glacier, Antarctica.

Delin, K. A.↗

Use of mercuric iodide X-ray detectors with alpha backscattering spectrometers for space applications

The authors present X-ray fluorescence (XRF) spectra of different extraterrestrial samples taken with a mercuric iodide (HgI2) spectrometer inserted into an alpha backscattering instrument identical to that used in the Soviet Phobos mission. The results obtained with the HgI2 ambient temperature detector are compared with those obtained using an Si(Li) cryogenically cooled detector. Efforts to design an optimized instrument for space application are also described. The results presented indicate that the energy resolution and sensitivity of HgI2 detectors are adequate to meet the performance needs of a number of proposed space applications, particularly those in which cooled silicon X-ray detectors are impractical or even not usable, such as for the target science programs on geoscience opportunities for lunar surface, Mars surface, and other comet and planetary missions being planned by NASA and ESA.

Iwanczyk, J. S.↗

Measurement of heat conduction through stacked screens

This paper describes the experimental apparatus for the measurement of heat conduction through stacked screens as well as some experimental results taken with the apparatus. Screens are stacked in a fiberglass-epoxy cylinder, which is 24.4 mm in diameter and 55 mm in length. The cold end of the stacked screens is cooled by a Gifford-McMahon (GM) cryocooler at cryogenic temperature, and the hot end is maintained at room temperature. Heat conduction through the screens is determined from the temperature gradient in a calibrated heat flow sensor mounted between the cold end of the stacked screens and the GM cryocooler. The samples used for these experiments consisted of 400-mesh stainless steel screens, 400-mesh phosphor bronze screens, and two different porosities of 325-mesh stainless steel screens. The wire diameter of the 400-mesh stainless steel and phosphor bronze screens was 25.4 micrometers and the 325-mesh stainless steel screen wire diameters were 22.9 micrometers and 27.9 micrometers. Standard porosity values were used for the experimental data with additional porosity values used on selected experiments. The experimental results showed that the helium gas between each screen enhanced the heat conduction through the stacked screens by several orders of magnitude compared to that in vacuum. The conduction degradation factor is the ratio of actual heat conduction to the heat conduction where the regenerator material is assumed to be a solid rod of the same cross sectional area as the metal fraction of the screen. This factor was about 0.1 for the stainless steel and 0.022 for the phosphor bronze, and almost constant for the temperature range of 40 to 80 K at the cold end.

NASA Discipline Environmental Health↗